Buddy balloon to deliver a percutaneous aortic valve device: A percutaneous shoehorn?

Percutaneous aortic valve replacement is performed with increasing frequency in patients with severe aortic stenosis at prohibitive surgical risk. Currently available devices are however in their early development stage, and are thus quite bulky with a large profile, with ensuing difficulties in del...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Catheterization and cardiovascular interventions 2009-11, Vol.74 (5), p.805-807
Hauptverfasser: Sheiban, Imad, Infantino, Vincenzo, Bollati, Mario
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 807
container_issue 5
container_start_page 805
container_title Catheterization and cardiovascular interventions
container_volume 74
creator Sheiban, Imad
Infantino, Vincenzo
Bollati, Mario
description Percutaneous aortic valve replacement is performed with increasing frequency in patients with severe aortic stenosis at prohibitive surgical risk. Currently available devices are however in their early development stage, and are thus quite bulky with a large profile, with ensuing difficulties in delivery of the device through a stenotic aortic valve. We report hereby a case in which we employed a buddy wire and balloon technique as a “shoehorn” to enable accurate delivery of a balloon‐expandable aortic valve prosthesis from the transfemoral route. © 2009 Wiley‐Liss, Inc.
doi_str_mv 10.1002/ccd.22118
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_734117269</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>734117269</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3598-a983cf5f8bdc81a0734ef477a22efa599b6afb5b4a7157e6f4e8ea264ad9d8fa3</originalsourceid><addsrcrecordid>eNp1kE1LAzEQQIMotlYP_gHZm3jYNsl-xovU9RMKXix4C9lkQlfSpia7K_33RrcgHjzNMDwew0PonOApwZjOpFRTSgkpD9CYZJTGBc3fDvc7YWk-Qifev2OMWU7ZMRqFG8tJkozR8rZTahfVwhhrN1FrIwWm6cFFItqCk10rNmA7Hwnr2kZGvTA9BKZvJFxH87-MX1lYWbe5OUVHWhgPZ_s5QcuH-9fqKV68PD5X80Usk4yVsWBlInWmy1rJkghcJCnotCgEpaBFxlidC11ndSoKkhWQ6xRKEDRPhWKq1CKZoMvBu3X2owPf8nXjJRgzPMSDkJAQgwXyaiCls9470HzrmrVwO04w_47IQ0T-EzGwF3trV69B_ZL7agGYDcBnY2D3v4lX1d2g_ALJ63yR</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>734117269</pqid></control><display><type>article</type><title>Buddy balloon to deliver a percutaneous aortic valve device: A percutaneous shoehorn?</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Sheiban, Imad ; Infantino, Vincenzo ; Bollati, Mario</creator><creatorcontrib>Sheiban, Imad ; Infantino, Vincenzo ; Bollati, Mario</creatorcontrib><description>Percutaneous aortic valve replacement is performed with increasing frequency in patients with severe aortic stenosis at prohibitive surgical risk. Currently available devices are however in their early development stage, and are thus quite bulky with a large profile, with ensuing difficulties in delivery of the device through a stenotic aortic valve. We report hereby a case in which we employed a buddy wire and balloon technique as a “shoehorn” to enable accurate delivery of a balloon‐expandable aortic valve prosthesis from the transfemoral route. © 2009 Wiley‐Liss, Inc.</description><identifier>ISSN: 1522-1946</identifier><identifier>EISSN: 1522-726X</identifier><identifier>DOI: 10.1002/ccd.22118</identifier><identifier>PMID: 19496133</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Aged, 80 and over ; aortic stenosis ; aortic valve replacement ; Aortic Valve Stenosis - diagnostic imaging ; Aortic Valve Stenosis - therapy ; buddy balloon ; buddy wire ; Catheterization - instrumentation ; Equipment Design ; Female ; Heart Valve Prosthesis ; Heart Valve Prosthesis Implantation - instrumentation ; Heart Valve Prosthesis Implantation - methods ; Humans ; percutaneous valve ; Prosthesis Design ; Radiography ; Severity of Illness Index ; Treatment Outcome</subject><ispartof>Catheterization and cardiovascular interventions, 2009-11, Vol.74 (5), p.805-807</ispartof><rights>Copyright © 2009 Wiley‐Liss, Inc.</rights><rights>Copyright 2009 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3598-a983cf5f8bdc81a0734ef477a22efa599b6afb5b4a7157e6f4e8ea264ad9d8fa3</citedby><cites>FETCH-LOGICAL-c3598-a983cf5f8bdc81a0734ef477a22efa599b6afb5b4a7157e6f4e8ea264ad9d8fa3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fccd.22118$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fccd.22118$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19496133$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sheiban, Imad</creatorcontrib><creatorcontrib>Infantino, Vincenzo</creatorcontrib><creatorcontrib>Bollati, Mario</creatorcontrib><title>Buddy balloon to deliver a percutaneous aortic valve device: A percutaneous shoehorn?</title><title>Catheterization and cardiovascular interventions</title><addtitle>Catheter Cardiovasc Interv</addtitle><description>Percutaneous aortic valve replacement is performed with increasing frequency in patients with severe aortic stenosis at prohibitive surgical risk. Currently available devices are however in their early development stage, and are thus quite bulky with a large profile, with ensuing difficulties in delivery of the device through a stenotic aortic valve. We report hereby a case in which we employed a buddy wire and balloon technique as a “shoehorn” to enable accurate delivery of a balloon‐expandable aortic valve prosthesis from the transfemoral route. © 2009 Wiley‐Liss, Inc.</description><subject>Aged, 80 and over</subject><subject>aortic stenosis</subject><subject>aortic valve replacement</subject><subject>Aortic Valve Stenosis - diagnostic imaging</subject><subject>Aortic Valve Stenosis - therapy</subject><subject>buddy balloon</subject><subject>buddy wire</subject><subject>Catheterization - instrumentation</subject><subject>Equipment Design</subject><subject>Female</subject><subject>Heart Valve Prosthesis</subject><subject>Heart Valve Prosthesis Implantation - instrumentation</subject><subject>Heart Valve Prosthesis Implantation - methods</subject><subject>Humans</subject><subject>percutaneous valve</subject><subject>Prosthesis Design</subject><subject>Radiography</subject><subject>Severity of Illness Index</subject><subject>Treatment Outcome</subject><issn>1522-1946</issn><issn>1522-726X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kE1LAzEQQIMotlYP_gHZm3jYNsl-xovU9RMKXix4C9lkQlfSpia7K_33RrcgHjzNMDwew0PonOApwZjOpFRTSgkpD9CYZJTGBc3fDvc7YWk-Qifev2OMWU7ZMRqFG8tJkozR8rZTahfVwhhrN1FrIwWm6cFFItqCk10rNmA7Hwnr2kZGvTA9BKZvJFxH87-MX1lYWbe5OUVHWhgPZ_s5QcuH-9fqKV68PD5X80Usk4yVsWBlInWmy1rJkghcJCnotCgEpaBFxlidC11ndSoKkhWQ6xRKEDRPhWKq1CKZoMvBu3X2owPf8nXjJRgzPMSDkJAQgwXyaiCls9470HzrmrVwO04w_47IQ0T-EzGwF3trV69B_ZL7agGYDcBnY2D3v4lX1d2g_ALJ63yR</recordid><startdate>20091101</startdate><enddate>20091101</enddate><creator>Sheiban, Imad</creator><creator>Infantino, Vincenzo</creator><creator>Bollati, Mario</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20091101</creationdate><title>Buddy balloon to deliver a percutaneous aortic valve device: A percutaneous shoehorn?</title><author>Sheiban, Imad ; Infantino, Vincenzo ; Bollati, Mario</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3598-a983cf5f8bdc81a0734ef477a22efa599b6afb5b4a7157e6f4e8ea264ad9d8fa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Aged, 80 and over</topic><topic>aortic stenosis</topic><topic>aortic valve replacement</topic><topic>Aortic Valve Stenosis - diagnostic imaging</topic><topic>Aortic Valve Stenosis - therapy</topic><topic>buddy balloon</topic><topic>buddy wire</topic><topic>Catheterization - instrumentation</topic><topic>Equipment Design</topic><topic>Female</topic><topic>Heart Valve Prosthesis</topic><topic>Heart Valve Prosthesis Implantation - instrumentation</topic><topic>Heart Valve Prosthesis Implantation - methods</topic><topic>Humans</topic><topic>percutaneous valve</topic><topic>Prosthesis Design</topic><topic>Radiography</topic><topic>Severity of Illness Index</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sheiban, Imad</creatorcontrib><creatorcontrib>Infantino, Vincenzo</creatorcontrib><creatorcontrib>Bollati, Mario</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Catheterization and cardiovascular interventions</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sheiban, Imad</au><au>Infantino, Vincenzo</au><au>Bollati, Mario</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Buddy balloon to deliver a percutaneous aortic valve device: A percutaneous shoehorn?</atitle><jtitle>Catheterization and cardiovascular interventions</jtitle><addtitle>Catheter Cardiovasc Interv</addtitle><date>2009-11-01</date><risdate>2009</risdate><volume>74</volume><issue>5</issue><spage>805</spage><epage>807</epage><pages>805-807</pages><issn>1522-1946</issn><eissn>1522-726X</eissn><abstract>Percutaneous aortic valve replacement is performed with increasing frequency in patients with severe aortic stenosis at prohibitive surgical risk. Currently available devices are however in their early development stage, and are thus quite bulky with a large profile, with ensuing difficulties in delivery of the device through a stenotic aortic valve. We report hereby a case in which we employed a buddy wire and balloon technique as a “shoehorn” to enable accurate delivery of a balloon‐expandable aortic valve prosthesis from the transfemoral route. © 2009 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>19496133</pmid><doi>10.1002/ccd.22118</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1522-1946
ispartof Catheterization and cardiovascular interventions, 2009-11, Vol.74 (5), p.805-807
issn 1522-1946
1522-726X
language eng
recordid cdi_proquest_miscellaneous_734117269
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Aged, 80 and over
aortic stenosis
aortic valve replacement
Aortic Valve Stenosis - diagnostic imaging
Aortic Valve Stenosis - therapy
buddy balloon
buddy wire
Catheterization - instrumentation
Equipment Design
Female
Heart Valve Prosthesis
Heart Valve Prosthesis Implantation - instrumentation
Heart Valve Prosthesis Implantation - methods
Humans
percutaneous valve
Prosthesis Design
Radiography
Severity of Illness Index
Treatment Outcome
title Buddy balloon to deliver a percutaneous aortic valve device: A percutaneous shoehorn?
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T10%3A46%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Buddy%20balloon%20to%20deliver%20a%20percutaneous%20aortic%20valve%20device:%20A%20percutaneous%20shoehorn?&rft.jtitle=Catheterization%20and%20cardiovascular%20interventions&rft.au=Sheiban,%20Imad&rft.date=2009-11-01&rft.volume=74&rft.issue=5&rft.spage=805&rft.epage=807&rft.pages=805-807&rft.issn=1522-1946&rft.eissn=1522-726X&rft_id=info:doi/10.1002/ccd.22118&rft_dat=%3Cproquest_cross%3E734117269%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=734117269&rft_id=info:pmid/19496133&rfr_iscdi=true