Clostridium infection in a knee extensor mechanism allograft: case report and review

An unusual case of Clostridium perfringens infection after an allograft reconstruction of an extensor mechanism in a multiply revised total knee arthroplasty is reported. The case occurred in an elderly patient with an underlying bleeding dyscrasia who had previously undergone two revision total kne...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The knee 2003-06, Vol.10 (2), p.149-153
Hauptverfasser: Pearle, Andrew D., Bates, James E., Tolo, Eric T., Windsor, Russell E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An unusual case of Clostridium perfringens infection after an allograft reconstruction of an extensor mechanism in a multiply revised total knee arthroplasty is reported. The case occurred in an elderly patient with an underlying bleeding dyscrasia who had previously undergone two revision total knee arthroplasties. The patient was treated by open irrigation, debridement, removal of allograft and prosthesis, intravenous antibiotics, and implantation of an antibiotic impregnated cement spacer utilizing an intramedullary rod.
ISSN:0968-0160
1873-5800
DOI:10.1016/S0968-0160(02)00091-1