Ion chromatographic determination of organic acids in food samples using a permanent coating graphite carbon column

From the viewpoint of a graphite carbon column with excellent durability, it was applied to the ion chromatography (IC) of several organic acids. The carbon column was permanently coated with the cetyltrimethylammonium (CTMA) ion, and the elution behaviors of several organic acids (acetic acid, lact...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2007-04, Vol.72 (1), p.305-309
Hauptverfasser: Yoshikawa, Kenji, Okamura, Miho, Inokuchi, Miki, Sakuragawa, Akio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 309
container_issue 1
container_start_page 305
container_title Talanta (Oxford)
container_volume 72
creator Yoshikawa, Kenji
Okamura, Miho
Inokuchi, Miki
Sakuragawa, Akio
description From the viewpoint of a graphite carbon column with excellent durability, it was applied to the ion chromatography (IC) of several organic acids. The carbon column was permanently coated with the cetyltrimethylammonium (CTMA) ion, and the elution behaviors of several organic acids (acetic acid, lactic acid, succinic acid, malic acid, tartaric acid, citric acid) and inorganic anions (Cl −, NO 2 −, NO 3 −, SO 4 2−) were examined according to a non-suppressed IC coupled with conductivity detector, when an ion-exchange ability was given to the graphite carbon column. When salicylic acid and sodium salicylate were used as a mobile phase, each organic acid are analyzed approximately 10 min. But the separation of malic acid, chloride and nitrite was difficult. When benzoic acid and 2-amino-2-hydroxymethyl-1,3-puropanediol (tris aminomethane) were used as a mobile phase, tartaric acid and citric acid, etc. with large valency showed tendency to which the width of each peaks extended and retention time increased. However, it was possible to separate excellently for the analytes detected within 10 min. The developed method was then applied to the determination of organic acids in several food samples.
doi_str_mv 10.1016/j.talanta.2006.10.020
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733877668</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914006006874</els_id><sourcerecordid>733877668</sourcerecordid><originalsourceid>FETCH-LOGICAL-c460t-35e22df622dc10ba811486b2aad56def349783711992a9da36f7a34ddaff8ef23</originalsourceid><addsrcrecordid>eNqFkE2PFCEQhonRuOPqT9BwMZ5mhKYbmpMxGz822cSLnkkNFLNMuqEF2sR_L5PpZI9eIKl63ip4CHnL2YEzLj-eDxUmiBUOHWOy1Q6sY8_Ijo9K7MWgxHOyY0zoveY9uyGvSjkzxjrBxEtywzVTXHK9I-U-RWofc5qhplOG5TFY6rBinkOEGlo3eZryCWJrgA2u0BCpT8nRAvMyYaFrCfFEgS4tBBFjpTa1aKtdB1akFvLxsihN6xxfkxcepoJvtvuW_Pr65efd9_3Dj2_3d58f9raXrLZPYNc5L9thOTvCyHk_ymMH4Abp0Iteq1EozrXuQDsQ0isQvXPg_Yi-E7fkw3XuktPvFUs1cygWp6YN01qMEmJUSsqxkcOVtDmVktGbJYcZ8l_DmbnoNmez6TYX3Zdy091y77YN63FG95Ta_Dbg_QZAsTD5DNGG8sSNcuh1PzTu05XD5uNPwGyKDRgtupDRVuNS-M9T_gF9XKLY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733877668</pqid></control><display><type>article</type><title>Ion chromatographic determination of organic acids in food samples using a permanent coating graphite carbon column</title><source>Elsevier ScienceDirect Journals</source><creator>Yoshikawa, Kenji ; Okamura, Miho ; Inokuchi, Miki ; Sakuragawa, Akio</creator><creatorcontrib>Yoshikawa, Kenji ; Okamura, Miho ; Inokuchi, Miki ; Sakuragawa, Akio</creatorcontrib><description>From the viewpoint of a graphite carbon column with excellent durability, it was applied to the ion chromatography (IC) of several organic acids. The carbon column was permanently coated with the cetyltrimethylammonium (CTMA) ion, and the elution behaviors of several organic acids (acetic acid, lactic acid, succinic acid, malic acid, tartaric acid, citric acid) and inorganic anions (Cl −, NO 2 −, NO 3 −, SO 4 2−) were examined according to a non-suppressed IC coupled with conductivity detector, when an ion-exchange ability was given to the graphite carbon column. When salicylic acid and sodium salicylate were used as a mobile phase, each organic acid are analyzed approximately 10 min. But the separation of malic acid, chloride and nitrite was difficult. When benzoic acid and 2-amino-2-hydroxymethyl-1,3-puropanediol (tris aminomethane) were used as a mobile phase, tartaric acid and citric acid, etc. with large valency showed tendency to which the width of each peaks extended and retention time increased. However, it was possible to separate excellently for the analytes detected within 10 min. The developed method was then applied to the determination of organic acids in several food samples.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2006.10.020</identifier><identifier>PMID: 19071619</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Benzoic acid ; Cetyltrimethylammonium ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Electrochemical methods ; Exact sciences and technology ; Graphite carbon column ; Ion chromatography ; Organic acid ; Other chromatographic methods</subject><ispartof>Talanta (Oxford), 2007-04, Vol.72 (1), p.305-309</ispartof><rights>2006 Elsevier B.V.</rights><rights>2007 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c460t-35e22df622dc10ba811486b2aad56def349783711992a9da36f7a34ddaff8ef23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914006006874$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=18654945$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19071619$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yoshikawa, Kenji</creatorcontrib><creatorcontrib>Okamura, Miho</creatorcontrib><creatorcontrib>Inokuchi, Miki</creatorcontrib><creatorcontrib>Sakuragawa, Akio</creatorcontrib><title>Ion chromatographic determination of organic acids in food samples using a permanent coating graphite carbon column</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>From the viewpoint of a graphite carbon column with excellent durability, it was applied to the ion chromatography (IC) of several organic acids. The carbon column was permanently coated with the cetyltrimethylammonium (CTMA) ion, and the elution behaviors of several organic acids (acetic acid, lactic acid, succinic acid, malic acid, tartaric acid, citric acid) and inorganic anions (Cl −, NO 2 −, NO 3 −, SO 4 2−) were examined according to a non-suppressed IC coupled with conductivity detector, when an ion-exchange ability was given to the graphite carbon column. When salicylic acid and sodium salicylate were used as a mobile phase, each organic acid are analyzed approximately 10 min. But the separation of malic acid, chloride and nitrite was difficult. When benzoic acid and 2-amino-2-hydroxymethyl-1,3-puropanediol (tris aminomethane) were used as a mobile phase, tartaric acid and citric acid, etc. with large valency showed tendency to which the width of each peaks extended and retention time increased. However, it was possible to separate excellently for the analytes detected within 10 min. The developed method was then applied to the determination of organic acids in several food samples.</description><subject>Analytical chemistry</subject><subject>Benzoic acid</subject><subject>Cetyltrimethylammonium</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Electrochemical methods</subject><subject>Exact sciences and technology</subject><subject>Graphite carbon column</subject><subject>Ion chromatography</subject><subject>Organic acid</subject><subject>Other chromatographic methods</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqFkE2PFCEQhonRuOPqT9BwMZ5mhKYbmpMxGz822cSLnkkNFLNMuqEF2sR_L5PpZI9eIKl63ip4CHnL2YEzLj-eDxUmiBUOHWOy1Q6sY8_Ijo9K7MWgxHOyY0zoveY9uyGvSjkzxjrBxEtywzVTXHK9I-U-RWofc5qhplOG5TFY6rBinkOEGlo3eZryCWJrgA2u0BCpT8nRAvMyYaFrCfFEgS4tBBFjpTa1aKtdB1akFvLxsihN6xxfkxcepoJvtvuW_Pr65efd9_3Dj2_3d58f9raXrLZPYNc5L9thOTvCyHk_ymMH4Abp0Iteq1EozrXuQDsQ0isQvXPg_Yi-E7fkw3XuktPvFUs1cygWp6YN01qMEmJUSsqxkcOVtDmVktGbJYcZ8l_DmbnoNmez6TYX3Zdy091y77YN63FG95Ta_Dbg_QZAsTD5DNGG8sSNcuh1PzTu05XD5uNPwGyKDRgtupDRVuNS-M9T_gF9XKLY</recordid><startdate>20070415</startdate><enddate>20070415</enddate><creator>Yoshikawa, Kenji</creator><creator>Okamura, Miho</creator><creator>Inokuchi, Miki</creator><creator>Sakuragawa, Akio</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20070415</creationdate><title>Ion chromatographic determination of organic acids in food samples using a permanent coating graphite carbon column</title><author>Yoshikawa, Kenji ; Okamura, Miho ; Inokuchi, Miki ; Sakuragawa, Akio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c460t-35e22df622dc10ba811486b2aad56def349783711992a9da36f7a34ddaff8ef23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Analytical chemistry</topic><topic>Benzoic acid</topic><topic>Cetyltrimethylammonium</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Electrochemical methods</topic><topic>Exact sciences and technology</topic><topic>Graphite carbon column</topic><topic>Ion chromatography</topic><topic>Organic acid</topic><topic>Other chromatographic methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yoshikawa, Kenji</creatorcontrib><creatorcontrib>Okamura, Miho</creatorcontrib><creatorcontrib>Inokuchi, Miki</creatorcontrib><creatorcontrib>Sakuragawa, Akio</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yoshikawa, Kenji</au><au>Okamura, Miho</au><au>Inokuchi, Miki</au><au>Sakuragawa, Akio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ion chromatographic determination of organic acids in food samples using a permanent coating graphite carbon column</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2007-04-15</date><risdate>2007</risdate><volume>72</volume><issue>1</issue><spage>305</spage><epage>309</epage><pages>305-309</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>From the viewpoint of a graphite carbon column with excellent durability, it was applied to the ion chromatography (IC) of several organic acids. The carbon column was permanently coated with the cetyltrimethylammonium (CTMA) ion, and the elution behaviors of several organic acids (acetic acid, lactic acid, succinic acid, malic acid, tartaric acid, citric acid) and inorganic anions (Cl −, NO 2 −, NO 3 −, SO 4 2−) were examined according to a non-suppressed IC coupled with conductivity detector, when an ion-exchange ability was given to the graphite carbon column. When salicylic acid and sodium salicylate were used as a mobile phase, each organic acid are analyzed approximately 10 min. But the separation of malic acid, chloride and nitrite was difficult. When benzoic acid and 2-amino-2-hydroxymethyl-1,3-puropanediol (tris aminomethane) were used as a mobile phase, tartaric acid and citric acid, etc. with large valency showed tendency to which the width of each peaks extended and retention time increased. However, it was possible to separate excellently for the analytes detected within 10 min. The developed method was then applied to the determination of organic acids in several food samples.</abstract><cop>Amsterdam</cop><cop>Oxford</cop><pub>Elsevier B.V</pub><pmid>19071619</pmid><doi>10.1016/j.talanta.2006.10.020</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2007-04, Vol.72 (1), p.305-309
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733877668
source Elsevier ScienceDirect Journals
subjects Analytical chemistry
Benzoic acid
Cetyltrimethylammonium
Chemistry
Chromatographic methods and physical methods associated with chromatography
Electrochemical methods
Exact sciences and technology
Graphite carbon column
Ion chromatography
Organic acid
Other chromatographic methods
title Ion chromatographic determination of organic acids in food samples using a permanent coating graphite carbon column
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T09%3A37%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ion%20chromatographic%20determination%20of%20organic%20acids%20in%20food%20samples%20using%20a%20permanent%20coating%20graphite%20carbon%20column&rft.jtitle=Talanta%20(Oxford)&rft.au=Yoshikawa,%20Kenji&rft.date=2007-04-15&rft.volume=72&rft.issue=1&rft.spage=305&rft.epage=309&rft.pages=305-309&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/j.talanta.2006.10.020&rft_dat=%3Cproquest_cross%3E733877668%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733877668&rft_id=info:pmid/19071619&rft_els_id=S0039914006006874&rfr_iscdi=true