Arterial mechanical impedance is a sensitive stress response monitor during general anesthesia

Arterial mechanical impedance is a characteristic of arterial dynamics that is determined by photoplethysmographic amplitude and direct arterial pressure, while mechanical impedance is indicated by stiffness, viscosity, and inertia. We compared the parameters of mechanical impedance and photoplethys...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Hiroshima journal of medical sciences 2009-12, Vol.58 (4), p.75-82
Hauptverfasser: Nakamura, Ryuji, Saeki, Noboru, Kutluk, Abdugheni, Shiba, Kenji, Tsuji, Toshio, Hamada, Hiroshi, Kawamoto, Masashi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 82
container_issue 4
container_start_page 75
container_title Hiroshima journal of medical sciences
container_volume 58
creator Nakamura, Ryuji
Saeki, Noboru
Kutluk, Abdugheni
Shiba, Kenji
Tsuji, Toshio
Hamada, Hiroshi
Kawamoto, Masashi
description Arterial mechanical impedance is a characteristic of arterial dynamics that is determined by photoplethysmographic amplitude and direct arterial pressure, while mechanical impedance is indicated by stiffness, viscosity, and inertia. We compared the parameters of mechanical impedance and photoplethysmographic amplitude to estimate the magnitude of stress response in patients undergoing general anesthesia by measuring direct arterial pressure. After sedating each patient with propofol, photoplethysmographic amplitude and mechanical impedance were measured as baseline control values, then 3 min after fentanyl administration (2 microg kg(-1)), the parameters were measured again as post-fentanyl values. Thereafter, a direct laryngoscopy procedure was performed and post-laryngoscopy values for the parameters were determined. The magnitudes of response to each event were compared by using the ratio of the measurements from the preceding event. Then, comparisons of the magnitudes were performed after coordinating each response in the same direction. Our results showed that both stiffness and viscosity of mechanical impedance had greater variations than photoplethysmographic amplitude. In conclusion, we propose stiffness and viscosity derived from arterial mechanical impedance as sensitive parameters to monitor stress responses during general anesthesia.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_733835698</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733835698</sourcerecordid><originalsourceid>FETCH-LOGICAL-j193t-5cf8bbf08e09b46de4612a54fa40d2e1e3ad3aff447e657ac2e62015049c800d3</originalsourceid><addsrcrecordid>eNo1UMlOwzAQ9QFES-EXkG-cIk28ZDlWFZtUiQtciRx70rpKnOBJkPh7LNFeZt7hzVvmiq0B8ioToMWK3RKdAGQtIL9hKwFS1aWGNfvaxhmjNz0f0B5N8DZBP0zoTLDIPXHDCQP52f8gpzkiEU9jGgMhH8bg5zFyt0QfDvyAAWO6NwFpPiJ5c8euO9MT3p_3hn0-P33sXrP9-8vbbrvPTnkt50zbrmrbDiqEulWFQ1XkwmjVGQVOYI7SOGm6TqkSC10aK7BITTSo2lYATm7Y47_uFMfvJbk3gyeLfZ-ijAs1pZSV1EVdJebDmbm0A7pmin4w8be5vET-Ac3YXgg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733835698</pqid></control><display><type>article</type><title>Arterial mechanical impedance is a sensitive stress response monitor during general anesthesia</title><source>MEDLINE</source><source>Open Access Titles of Japan</source><creator>Nakamura, Ryuji ; Saeki, Noboru ; Kutluk, Abdugheni ; Shiba, Kenji ; Tsuji, Toshio ; Hamada, Hiroshi ; Kawamoto, Masashi</creator><creatorcontrib>Nakamura, Ryuji ; Saeki, Noboru ; Kutluk, Abdugheni ; Shiba, Kenji ; Tsuji, Toshio ; Hamada, Hiroshi ; Kawamoto, Masashi</creatorcontrib><description>Arterial mechanical impedance is a characteristic of arterial dynamics that is determined by photoplethysmographic amplitude and direct arterial pressure, while mechanical impedance is indicated by stiffness, viscosity, and inertia. We compared the parameters of mechanical impedance and photoplethysmographic amplitude to estimate the magnitude of stress response in patients undergoing general anesthesia by measuring direct arterial pressure. After sedating each patient with propofol, photoplethysmographic amplitude and mechanical impedance were measured as baseline control values, then 3 min after fentanyl administration (2 microg kg(-1)), the parameters were measured again as post-fentanyl values. Thereafter, a direct laryngoscopy procedure was performed and post-laryngoscopy values for the parameters were determined. The magnitudes of response to each event were compared by using the ratio of the measurements from the preceding event. Then, comparisons of the magnitudes were performed after coordinating each response in the same direction. Our results showed that both stiffness and viscosity of mechanical impedance had greater variations than photoplethysmographic amplitude. In conclusion, we propose stiffness and viscosity derived from arterial mechanical impedance as sensitive parameters to monitor stress responses during general anesthesia.</description><identifier>ISSN: 0018-2052</identifier><identifier>PMID: 20349750</identifier><language>eng</language><publisher>Japan</publisher><subject>Aged ; Anesthesia, General ; Anesthetics, Intravenous - pharmacology ; Arteries - anatomy &amp; histology ; Arteries - drug effects ; Arteries - metabolism ; Elasticity ; Female ; Fentanyl - pharmacology ; Hemodynamics - drug effects ; Humans ; Laryngoscopy ; Male ; Middle Aged ; Models, Cardiovascular ; Photoplethysmography ; Propofol - pharmacology ; Stress, Mechanical</subject><ispartof>Hiroshima journal of medical sciences, 2009-12, Vol.58 (4), p.75-82</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20349750$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nakamura, Ryuji</creatorcontrib><creatorcontrib>Saeki, Noboru</creatorcontrib><creatorcontrib>Kutluk, Abdugheni</creatorcontrib><creatorcontrib>Shiba, Kenji</creatorcontrib><creatorcontrib>Tsuji, Toshio</creatorcontrib><creatorcontrib>Hamada, Hiroshi</creatorcontrib><creatorcontrib>Kawamoto, Masashi</creatorcontrib><title>Arterial mechanical impedance is a sensitive stress response monitor during general anesthesia</title><title>Hiroshima journal of medical sciences</title><addtitle>Hiroshima J Med Sci</addtitle><description>Arterial mechanical impedance is a characteristic of arterial dynamics that is determined by photoplethysmographic amplitude and direct arterial pressure, while mechanical impedance is indicated by stiffness, viscosity, and inertia. We compared the parameters of mechanical impedance and photoplethysmographic amplitude to estimate the magnitude of stress response in patients undergoing general anesthesia by measuring direct arterial pressure. After sedating each patient with propofol, photoplethysmographic amplitude and mechanical impedance were measured as baseline control values, then 3 min after fentanyl administration (2 microg kg(-1)), the parameters were measured again as post-fentanyl values. Thereafter, a direct laryngoscopy procedure was performed and post-laryngoscopy values for the parameters were determined. The magnitudes of response to each event were compared by using the ratio of the measurements from the preceding event. Then, comparisons of the magnitudes were performed after coordinating each response in the same direction. Our results showed that both stiffness and viscosity of mechanical impedance had greater variations than photoplethysmographic amplitude. In conclusion, we propose stiffness and viscosity derived from arterial mechanical impedance as sensitive parameters to monitor stress responses during general anesthesia.</description><subject>Aged</subject><subject>Anesthesia, General</subject><subject>Anesthetics, Intravenous - pharmacology</subject><subject>Arteries - anatomy &amp; histology</subject><subject>Arteries - drug effects</subject><subject>Arteries - metabolism</subject><subject>Elasticity</subject><subject>Female</subject><subject>Fentanyl - pharmacology</subject><subject>Hemodynamics - drug effects</subject><subject>Humans</subject><subject>Laryngoscopy</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Models, Cardiovascular</subject><subject>Photoplethysmography</subject><subject>Propofol - pharmacology</subject><subject>Stress, Mechanical</subject><issn>0018-2052</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1UMlOwzAQ9QFES-EXkG-cIk28ZDlWFZtUiQtciRx70rpKnOBJkPh7LNFeZt7hzVvmiq0B8ioToMWK3RKdAGQtIL9hKwFS1aWGNfvaxhmjNz0f0B5N8DZBP0zoTLDIPXHDCQP52f8gpzkiEU9jGgMhH8bg5zFyt0QfDvyAAWO6NwFpPiJ5c8euO9MT3p_3hn0-P33sXrP9-8vbbrvPTnkt50zbrmrbDiqEulWFQ1XkwmjVGQVOYI7SOGm6TqkSC10aK7BITTSo2lYATm7Y47_uFMfvJbk3gyeLfZ-ijAs1pZSV1EVdJebDmbm0A7pmin4w8be5vET-Ac3YXgg</recordid><startdate>200912</startdate><enddate>200912</enddate><creator>Nakamura, Ryuji</creator><creator>Saeki, Noboru</creator><creator>Kutluk, Abdugheni</creator><creator>Shiba, Kenji</creator><creator>Tsuji, Toshio</creator><creator>Hamada, Hiroshi</creator><creator>Kawamoto, Masashi</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>200912</creationdate><title>Arterial mechanical impedance is a sensitive stress response monitor during general anesthesia</title><author>Nakamura, Ryuji ; Saeki, Noboru ; Kutluk, Abdugheni ; Shiba, Kenji ; Tsuji, Toshio ; Hamada, Hiroshi ; Kawamoto, Masashi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j193t-5cf8bbf08e09b46de4612a54fa40d2e1e3ad3aff447e657ac2e62015049c800d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Aged</topic><topic>Anesthesia, General</topic><topic>Anesthetics, Intravenous - pharmacology</topic><topic>Arteries - anatomy &amp; histology</topic><topic>Arteries - drug effects</topic><topic>Arteries - metabolism</topic><topic>Elasticity</topic><topic>Female</topic><topic>Fentanyl - pharmacology</topic><topic>Hemodynamics - drug effects</topic><topic>Humans</topic><topic>Laryngoscopy</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Models, Cardiovascular</topic><topic>Photoplethysmography</topic><topic>Propofol - pharmacology</topic><topic>Stress, Mechanical</topic><toplevel>online_resources</toplevel><creatorcontrib>Nakamura, Ryuji</creatorcontrib><creatorcontrib>Saeki, Noboru</creatorcontrib><creatorcontrib>Kutluk, Abdugheni</creatorcontrib><creatorcontrib>Shiba, Kenji</creatorcontrib><creatorcontrib>Tsuji, Toshio</creatorcontrib><creatorcontrib>Hamada, Hiroshi</creatorcontrib><creatorcontrib>Kawamoto, Masashi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Hiroshima journal of medical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nakamura, Ryuji</au><au>Saeki, Noboru</au><au>Kutluk, Abdugheni</au><au>Shiba, Kenji</au><au>Tsuji, Toshio</au><au>Hamada, Hiroshi</au><au>Kawamoto, Masashi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Arterial mechanical impedance is a sensitive stress response monitor during general anesthesia</atitle><jtitle>Hiroshima journal of medical sciences</jtitle><addtitle>Hiroshima J Med Sci</addtitle><date>2009-12</date><risdate>2009</risdate><volume>58</volume><issue>4</issue><spage>75</spage><epage>82</epage><pages>75-82</pages><issn>0018-2052</issn><abstract>Arterial mechanical impedance is a characteristic of arterial dynamics that is determined by photoplethysmographic amplitude and direct arterial pressure, while mechanical impedance is indicated by stiffness, viscosity, and inertia. We compared the parameters of mechanical impedance and photoplethysmographic amplitude to estimate the magnitude of stress response in patients undergoing general anesthesia by measuring direct arterial pressure. After sedating each patient with propofol, photoplethysmographic amplitude and mechanical impedance were measured as baseline control values, then 3 min after fentanyl administration (2 microg kg(-1)), the parameters were measured again as post-fentanyl values. Thereafter, a direct laryngoscopy procedure was performed and post-laryngoscopy values for the parameters were determined. The magnitudes of response to each event were compared by using the ratio of the measurements from the preceding event. Then, comparisons of the magnitudes were performed after coordinating each response in the same direction. Our results showed that both stiffness and viscosity of mechanical impedance had greater variations than photoplethysmographic amplitude. In conclusion, we propose stiffness and viscosity derived from arterial mechanical impedance as sensitive parameters to monitor stress responses during general anesthesia.</abstract><cop>Japan</cop><pmid>20349750</pmid><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0018-2052
ispartof Hiroshima journal of medical sciences, 2009-12, Vol.58 (4), p.75-82
issn 0018-2052
language eng
recordid cdi_proquest_miscellaneous_733835698
source MEDLINE; Open Access Titles of Japan
subjects Aged
Anesthesia, General
Anesthetics, Intravenous - pharmacology
Arteries - anatomy & histology
Arteries - drug effects
Arteries - metabolism
Elasticity
Female
Fentanyl - pharmacology
Hemodynamics - drug effects
Humans
Laryngoscopy
Male
Middle Aged
Models, Cardiovascular
Photoplethysmography
Propofol - pharmacology
Stress, Mechanical
title Arterial mechanical impedance is a sensitive stress response monitor during general anesthesia
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T06%3A30%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Arterial%20mechanical%20impedance%20is%20a%20sensitive%20stress%20response%20monitor%20during%20general%20anesthesia&rft.jtitle=Hiroshima%20journal%20of%20medical%20sciences&rft.au=Nakamura,%20Ryuji&rft.date=2009-12&rft.volume=58&rft.issue=4&rft.spage=75&rft.epage=82&rft.pages=75-82&rft.issn=0018-2052&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E733835698%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733835698&rft_id=info:pmid/20349750&rfr_iscdi=true