The application of coulometry for total antioxidant capacity determination of human blood

New coulometric method for estimation of blood and plasma total antioxidant capacity (TAC) based on using electrogenerated bromine was proposed. TAC of blood from patients with chronic renal disease undergoing long-term hemodialysis was investigated. Statistical significant changes in TAC level of v...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2006-01, Vol.68 (3), p.800-805
Hauptverfasser: Ziyatdinova, Guzel K., Budnikov, Herman C., Pogorel’tzev, Valery I., Ganeev, Talgat S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 805
container_issue 3
container_start_page 800
container_title Talanta (Oxford)
container_volume 68
creator Ziyatdinova, Guzel K.
Budnikov, Herman C.
Pogorel’tzev, Valery I.
Ganeev, Talgat S.
description New coulometric method for estimation of blood and plasma total antioxidant capacity (TAC) based on using electrogenerated bromine was proposed. TAC of blood from patients with chronic renal disease undergoing long-term hemodialysis was investigated. Statistical significant changes in TAC level of venous and arterial blood were found. Catalase activity and low density lipoproteins (LDL) concentrations were determined. Linear correlation between TAC and parameters mentioned was found. Contribution from some individual antioxidants was investigated. The developed method for TAC assay is expressive, simple, stable and reliable, and successfully could be used for TAC determination of some biological fluids. This method could be applied in clinic for estimation of blood TAC from patients.
doi_str_mv 10.1016/j.talanta.2005.06.010
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733831136</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914005003395</els_id><sourcerecordid>733831136</sourcerecordid><originalsourceid>FETCH-LOGICAL-c430t-4afbd2aa39beab0eb784c02404f10326d8d7040a8e6d6f9c5482ffbdd67fe7fd3</originalsourceid><addsrcrecordid>eNqFkLtOxDAQRS0EguXxCSB3VAnjOJtHhRDiJSHRQEFlOfZYeJXEwXYQ-_d4tSsoqaaYe-ZqDiHnDHIGrLpa5VH2cowyLwCWOVQ5MNgjC9bUPOPLmu-TBQBvs5aVcESOQ1gBQMGBH5Ij1rR12vEFeX_9QCqnqbdKRutG6gxVbu7dgNGvqXGeRpeaaKqy7tvqNKmSk1Q2rqnGiH6w4y_6MQ9ypF3vnD4lB0b2Ac9284S83d-93j5mzy8PT7c3z5kqOcSslKbThZS87VB2gF3dlAqKEkrDgBeVbnQNJcgGK12ZVi3LpjAJ0VVtsDaan5DL7d3Ju88ZQxSDDQr7JAfdHETNecMZ41VKLrdJ5V0IHo2YvB2kXwsGYiNVrMROqthIFVCJJDVxF7uGuRtQ_1E7iylwvQ1g-vPLohdBWRwVautRRaGd_afiBxr8jVA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733831136</pqid></control><display><type>article</type><title>The application of coulometry for total antioxidant capacity determination of human blood</title><source>Elsevier ScienceDirect Journals</source><creator>Ziyatdinova, Guzel K. ; Budnikov, Herman C. ; Pogorel’tzev, Valery I. ; Ganeev, Talgat S.</creator><creatorcontrib>Ziyatdinova, Guzel K. ; Budnikov, Herman C. ; Pogorel’tzev, Valery I. ; Ganeev, Talgat S.</creatorcontrib><description>New coulometric method for estimation of blood and plasma total antioxidant capacity (TAC) based on using electrogenerated bromine was proposed. TAC of blood from patients with chronic renal disease undergoing long-term hemodialysis was investigated. Statistical significant changes in TAC level of venous and arterial blood were found. Catalase activity and low density lipoproteins (LDL) concentrations were determined. Linear correlation between TAC and parameters mentioned was found. Contribution from some individual antioxidants was investigated. The developed method for TAC assay is expressive, simple, stable and reliable, and successfully could be used for TAC determination of some biological fluids. This method could be applied in clinic for estimation of blood TAC from patients.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2005.06.010</identifier><identifier>PMID: 18970393</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Blood ; Catalase ; Chronic renal failure ; Coulometric titration ; Low density lipoproteins ; Total antioxidant capacity</subject><ispartof>Talanta (Oxford), 2006-01, Vol.68 (3), p.800-805</ispartof><rights>2005 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c430t-4afbd2aa39beab0eb784c02404f10326d8d7040a8e6d6f9c5482ffbdd67fe7fd3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914005003395$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18970393$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ziyatdinova, Guzel K.</creatorcontrib><creatorcontrib>Budnikov, Herman C.</creatorcontrib><creatorcontrib>Pogorel’tzev, Valery I.</creatorcontrib><creatorcontrib>Ganeev, Talgat S.</creatorcontrib><title>The application of coulometry for total antioxidant capacity determination of human blood</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>New coulometric method for estimation of blood and plasma total antioxidant capacity (TAC) based on using electrogenerated bromine was proposed. TAC of blood from patients with chronic renal disease undergoing long-term hemodialysis was investigated. Statistical significant changes in TAC level of venous and arterial blood were found. Catalase activity and low density lipoproteins (LDL) concentrations were determined. Linear correlation between TAC and parameters mentioned was found. Contribution from some individual antioxidants was investigated. The developed method for TAC assay is expressive, simple, stable and reliable, and successfully could be used for TAC determination of some biological fluids. This method could be applied in clinic for estimation of blood TAC from patients.</description><subject>Blood</subject><subject>Catalase</subject><subject>Chronic renal failure</subject><subject>Coulometric titration</subject><subject>Low density lipoproteins</subject><subject>Total antioxidant capacity</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2006</creationdate><recordtype>article</recordtype><recordid>eNqFkLtOxDAQRS0EguXxCSB3VAnjOJtHhRDiJSHRQEFlOfZYeJXEwXYQ-_d4tSsoqaaYe-ZqDiHnDHIGrLpa5VH2cowyLwCWOVQ5MNgjC9bUPOPLmu-TBQBvs5aVcESOQ1gBQMGBH5Ij1rR12vEFeX_9QCqnqbdKRutG6gxVbu7dgNGvqXGeRpeaaKqy7tvqNKmSk1Q2rqnGiH6w4y_6MQ9ypF3vnD4lB0b2Ac9284S83d-93j5mzy8PT7c3z5kqOcSslKbThZS87VB2gF3dlAqKEkrDgBeVbnQNJcgGK12ZVi3LpjAJ0VVtsDaan5DL7d3Ju88ZQxSDDQr7JAfdHETNecMZ41VKLrdJ5V0IHo2YvB2kXwsGYiNVrMROqthIFVCJJDVxF7uGuRtQ_1E7iylwvQ1g-vPLohdBWRwVautRRaGd_afiBxr8jVA</recordid><startdate>20060115</startdate><enddate>20060115</enddate><creator>Ziyatdinova, Guzel K.</creator><creator>Budnikov, Herman C.</creator><creator>Pogorel’tzev, Valery I.</creator><creator>Ganeev, Talgat S.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20060115</creationdate><title>The application of coulometry for total antioxidant capacity determination of human blood</title><author>Ziyatdinova, Guzel K. ; Budnikov, Herman C. ; Pogorel’tzev, Valery I. ; Ganeev, Talgat S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c430t-4afbd2aa39beab0eb784c02404f10326d8d7040a8e6d6f9c5482ffbdd67fe7fd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2006</creationdate><topic>Blood</topic><topic>Catalase</topic><topic>Chronic renal failure</topic><topic>Coulometric titration</topic><topic>Low density lipoproteins</topic><topic>Total antioxidant capacity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ziyatdinova, Guzel K.</creatorcontrib><creatorcontrib>Budnikov, Herman C.</creatorcontrib><creatorcontrib>Pogorel’tzev, Valery I.</creatorcontrib><creatorcontrib>Ganeev, Talgat S.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ziyatdinova, Guzel K.</au><au>Budnikov, Herman C.</au><au>Pogorel’tzev, Valery I.</au><au>Ganeev, Talgat S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The application of coulometry for total antioxidant capacity determination of human blood</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2006-01-15</date><risdate>2006</risdate><volume>68</volume><issue>3</issue><spage>800</spage><epage>805</epage><pages>800-805</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>New coulometric method for estimation of blood and plasma total antioxidant capacity (TAC) based on using electrogenerated bromine was proposed. TAC of blood from patients with chronic renal disease undergoing long-term hemodialysis was investigated. Statistical significant changes in TAC level of venous and arterial blood were found. Catalase activity and low density lipoproteins (LDL) concentrations were determined. Linear correlation between TAC and parameters mentioned was found. Contribution from some individual antioxidants was investigated. The developed method for TAC assay is expressive, simple, stable and reliable, and successfully could be used for TAC determination of some biological fluids. This method could be applied in clinic for estimation of blood TAC from patients.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>18970393</pmid><doi>10.1016/j.talanta.2005.06.010</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2006-01, Vol.68 (3), p.800-805
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733831136
source Elsevier ScienceDirect Journals
subjects Blood
Catalase
Chronic renal failure
Coulometric titration
Low density lipoproteins
Total antioxidant capacity
title The application of coulometry for total antioxidant capacity determination of human blood
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T04%3A13%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20application%20of%20coulometry%20for%20total%20antioxidant%20capacity%20determination%20of%20human%20blood&rft.jtitle=Talanta%20(Oxford)&rft.au=Ziyatdinova,%20Guzel%20K.&rft.date=2006-01-15&rft.volume=68&rft.issue=3&rft.spage=800&rft.epage=805&rft.pages=800-805&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2005.06.010&rft_dat=%3Cproquest_cross%3E733831136%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733831136&rft_id=info:pmid/18970393&rft_els_id=S0039914005003395&rfr_iscdi=true