Determination of selenium in water and soil by hydride generation atomic absorption spectrometry using solid reagents

A hydride generation method for the determination of traces of selenium at ng mL −1 concentration ranges has been introduced using a solid mixture of tartaric acid and sodium tetrahydroborate. Atomic absorption spectrometry (AAS) has been used as the detection system. Several parameters such as the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2005-05, Vol.66 (4), p.858-862
Hauptverfasser: Maleki, Norooz, Safavi, Afsaneh, Doroodmand, Mohammad Mahdi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 862
container_issue 4
container_start_page 858
container_title Talanta (Oxford)
container_volume 66
creator Maleki, Norooz
Safavi, Afsaneh
Doroodmand, Mohammad Mahdi
description A hydride generation method for the determination of traces of selenium at ng mL −1 concentration ranges has been introduced using a solid mixture of tartaric acid and sodium tetrahydroborate. Atomic absorption spectrometry (AAS) has been used as the detection system. Several parameters such as the ratio of tartaric acid to sodium tetrahydroborate, type and amount of acid, and the reaction temperature were optimized by using 640 ng mL −1 (16 ng per 25 μL) of Se(IV) standard solution. The calibration curve was linear from 20 to 1200 ng mL −1 (0.5–30 ng Se(IV) per 25 μL). The relative standard deviation (%R.S.D.) of the determination was 1.93% and the detection limit was 10.6 ng mL −1 (265 pg per 25 μL) of Se(IV). The reliability of the method was checked using different types of environmental samples, such as several types of water, a sample of soil and also in a kind of calcium phosphate sample by standard addition method. For conversion of Se(VI) present in real samples to Se(IV), l-cysteine was added to NaBH 4 and tartaric acid mixture. The results showed good agreement between this method and other hydride generation techniques.
doi_str_mv 10.1016/j.talanta.2004.12.053
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733830307</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914004007477</els_id><sourcerecordid>733830307</sourcerecordid><originalsourceid>FETCH-LOGICAL-c394t-ef70b99d582f88d63f71dab2a2878b6363ba0367abf330a9d5d44547596cbd653</originalsourceid><addsrcrecordid>eNqFkE2L1TAUQIMoznP0JyjZiKvWm6ZN2pXI-AkDbnQd8nE75tEmzyRV3r834yvM0lUgOefecAh5yaBlwMTbY1v0okPRbQfQt6xrYeCPyIGNkjd8kPwxOQDwqZlYD1fkWc5HAOg48Kfkio2TBBD8QLYPWDCtPujiY6BxphkXDH5bqQ_0j66PVAdHc_QLNWf68-ySd0jvMGC6OLrE1VuqTY7p9O8mn9CWFFcs6Uy37MNd9RfvaEJdxZKfkyezXjK-2M9r8uPTx-83X5rbb5-_3ry_bSyf-tLgLMFMkxvGbh5HJ_gsmdOm090oRyO44EYDF1KbmXPQFXR9P_RymIQ1Tgz8mry5zD2l-GvDXNTqs8WlhsO4ZSU5H2sRkJUcLqRNMeeEszolv-p0VgzUfXB1VHtwdR9csU7V4NV7tW_YzIruwdoLV-D1Duhs9TInHazPD5wYRd_1U-XeXTisPX57TCpbj8Gi86nWVC76_3zlL19Zo7U</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733830307</pqid></control><display><type>article</type><title>Determination of selenium in water and soil by hydride generation atomic absorption spectrometry using solid reagents</title><source>Elsevier ScienceDirect Journals</source><creator>Maleki, Norooz ; Safavi, Afsaneh ; Doroodmand, Mohammad Mahdi</creator><creatorcontrib>Maleki, Norooz ; Safavi, Afsaneh ; Doroodmand, Mohammad Mahdi</creatorcontrib><description>A hydride generation method for the determination of traces of selenium at ng mL −1 concentration ranges has been introduced using a solid mixture of tartaric acid and sodium tetrahydroborate. Atomic absorption spectrometry (AAS) has been used as the detection system. Several parameters such as the ratio of tartaric acid to sodium tetrahydroborate, type and amount of acid, and the reaction temperature were optimized by using 640 ng mL −1 (16 ng per 25 μL) of Se(IV) standard solution. The calibration curve was linear from 20 to 1200 ng mL −1 (0.5–30 ng Se(IV) per 25 μL). The relative standard deviation (%R.S.D.) of the determination was 1.93% and the detection limit was 10.6 ng mL −1 (265 pg per 25 μL) of Se(IV). The reliability of the method was checked using different types of environmental samples, such as several types of water, a sample of soil and also in a kind of calcium phosphate sample by standard addition method. For conversion of Se(VI) present in real samples to Se(IV), l-cysteine was added to NaBH 4 and tartaric acid mixture. The results showed good agreement between this method and other hydride generation techniques.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2004.12.053</identifier><identifier>PMID: 18970063</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Exact sciences and technology ; Hydride generation ; Selenium determination ; Solid reagents ; Spectrometric and optical methods</subject><ispartof>Talanta (Oxford), 2005-05, Vol.66 (4), p.858-862</ispartof><rights>2004 Elsevier B.V.</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c394t-ef70b99d582f88d63f71dab2a2878b6363ba0367abf330a9d5d44547596cbd653</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914004007477$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=16864249$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18970063$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Maleki, Norooz</creatorcontrib><creatorcontrib>Safavi, Afsaneh</creatorcontrib><creatorcontrib>Doroodmand, Mohammad Mahdi</creatorcontrib><title>Determination of selenium in water and soil by hydride generation atomic absorption spectrometry using solid reagents</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>A hydride generation method for the determination of traces of selenium at ng mL −1 concentration ranges has been introduced using a solid mixture of tartaric acid and sodium tetrahydroborate. Atomic absorption spectrometry (AAS) has been used as the detection system. Several parameters such as the ratio of tartaric acid to sodium tetrahydroborate, type and amount of acid, and the reaction temperature were optimized by using 640 ng mL −1 (16 ng per 25 μL) of Se(IV) standard solution. The calibration curve was linear from 20 to 1200 ng mL −1 (0.5–30 ng Se(IV) per 25 μL). The relative standard deviation (%R.S.D.) of the determination was 1.93% and the detection limit was 10.6 ng mL −1 (265 pg per 25 μL) of Se(IV). The reliability of the method was checked using different types of environmental samples, such as several types of water, a sample of soil and also in a kind of calcium phosphate sample by standard addition method. For conversion of Se(VI) present in real samples to Se(IV), l-cysteine was added to NaBH 4 and tartaric acid mixture. The results showed good agreement between this method and other hydride generation techniques.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>Hydride generation</subject><subject>Selenium determination</subject><subject>Solid reagents</subject><subject>Spectrometric and optical methods</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqFkE2L1TAUQIMoznP0JyjZiKvWm6ZN2pXI-AkDbnQd8nE75tEmzyRV3r834yvM0lUgOefecAh5yaBlwMTbY1v0okPRbQfQt6xrYeCPyIGNkjd8kPwxOQDwqZlYD1fkWc5HAOg48Kfkio2TBBD8QLYPWDCtPujiY6BxphkXDH5bqQ_0j66PVAdHc_QLNWf68-ySd0jvMGC6OLrE1VuqTY7p9O8mn9CWFFcs6Uy37MNd9RfvaEJdxZKfkyezXjK-2M9r8uPTx-83X5rbb5-_3ry_bSyf-tLgLMFMkxvGbh5HJ_gsmdOm090oRyO44EYDF1KbmXPQFXR9P_RymIQ1Tgz8mry5zD2l-GvDXNTqs8WlhsO4ZSU5H2sRkJUcLqRNMeeEszolv-p0VgzUfXB1VHtwdR9csU7V4NV7tW_YzIruwdoLV-D1Duhs9TInHazPD5wYRd_1U-XeXTisPX57TCpbj8Gi86nWVC76_3zlL19Zo7U</recordid><startdate>20050515</startdate><enddate>20050515</enddate><creator>Maleki, Norooz</creator><creator>Safavi, Afsaneh</creator><creator>Doroodmand, Mohammad Mahdi</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050515</creationdate><title>Determination of selenium in water and soil by hydride generation atomic absorption spectrometry using solid reagents</title><author>Maleki, Norooz ; Safavi, Afsaneh ; Doroodmand, Mohammad Mahdi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c394t-ef70b99d582f88d63f71dab2a2878b6363ba0367abf330a9d5d44547596cbd653</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>Hydride generation</topic><topic>Selenium determination</topic><topic>Solid reagents</topic><topic>Spectrometric and optical methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Maleki, Norooz</creatorcontrib><creatorcontrib>Safavi, Afsaneh</creatorcontrib><creatorcontrib>Doroodmand, Mohammad Mahdi</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Maleki, Norooz</au><au>Safavi, Afsaneh</au><au>Doroodmand, Mohammad Mahdi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of selenium in water and soil by hydride generation atomic absorption spectrometry using solid reagents</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2005-05-15</date><risdate>2005</risdate><volume>66</volume><issue>4</issue><spage>858</spage><epage>862</epage><pages>858-862</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>A hydride generation method for the determination of traces of selenium at ng mL −1 concentration ranges has been introduced using a solid mixture of tartaric acid and sodium tetrahydroborate. Atomic absorption spectrometry (AAS) has been used as the detection system. Several parameters such as the ratio of tartaric acid to sodium tetrahydroborate, type and amount of acid, and the reaction temperature were optimized by using 640 ng mL −1 (16 ng per 25 μL) of Se(IV) standard solution. The calibration curve was linear from 20 to 1200 ng mL −1 (0.5–30 ng Se(IV) per 25 μL). The relative standard deviation (%R.S.D.) of the determination was 1.93% and the detection limit was 10.6 ng mL −1 (265 pg per 25 μL) of Se(IV). The reliability of the method was checked using different types of environmental samples, such as several types of water, a sample of soil and also in a kind of calcium phosphate sample by standard addition method. For conversion of Se(VI) present in real samples to Se(IV), l-cysteine was added to NaBH 4 and tartaric acid mixture. The results showed good agreement between this method and other hydride generation techniques.</abstract><cop>Amsterdam</cop><cop>Oxford</cop><pub>Elsevier B.V</pub><pmid>18970063</pmid><doi>10.1016/j.talanta.2004.12.053</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 2005-05, Vol.66 (4), p.858-862
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733830307
source Elsevier ScienceDirect Journals
subjects Analytical chemistry
Chemistry
Exact sciences and technology
Hydride generation
Selenium determination
Solid reagents
Spectrometric and optical methods
title Determination of selenium in water and soil by hydride generation atomic absorption spectrometry using solid reagents
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T02%3A54%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20selenium%20in%20water%20and%20soil%20by%20hydride%20generation%20atomic%20absorption%20spectrometry%20using%20solid%20reagents&rft.jtitle=Talanta%20(Oxford)&rft.au=Maleki,%20Norooz&rft.date=2005-05-15&rft.volume=66&rft.issue=4&rft.spage=858&rft.epage=862&rft.pages=858-862&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/j.talanta.2004.12.053&rft_dat=%3Cproquest_cross%3E733830307%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733830307&rft_id=info:pmid/18970063&rft_els_id=S0039914004007477&rfr_iscdi=true