Fluorometric determination of uranium and tungsten with o-hydroxyhydroquinonephthalein in the presence of non-ionic surfactant

Complex formation between uranium or tungsten and o-hydroxyhydroquinonephthalein (Qnph) in various micellar surfactant media has been investigated fluorometrically, and determination of uranium and tungsten based on the difference between the relative fluorescence intensities of Qnph and the metal c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 1989-06, Vol.36 (6), p.688-690
Hauptverfasser: Mori, Itsuo, Fujita, Yoshikazu, Ikuta, Kimiko, Nakahashi, Yoshihiro, Kakimi, Etsuko, Kato, Keiji
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 690
container_issue 6
container_start_page 688
container_title Talanta (Oxford)
container_volume 36
creator Mori, Itsuo
Fujita, Yoshikazu
Ikuta, Kimiko
Nakahashi, Yoshihiro
Kakimi, Etsuko
Kato, Keiji
description Complex formation between uranium or tungsten and o-hydroxyhydroquinonephthalein (Qnph) in various micellar surfactant media has been investigated fluorometrically, and determination of uranium and tungsten based on the difference between the relative fluorescence intensities of Qnph and the metal complex at 535 nm, with excitation at 400 nm in the presence of poly(vinyl) alcohol as a non-ionic surfactant. The calibration curves were linear up to 1.0 μ/ml uranium and 0.9, μ/ml tungsten. The relative standard deviations (5 replicates) were 2.6% for tungsten and 3.0% for uranium, and recovery tests gave relatively good results (97–104%).
doi_str_mv 10.1016/0039-9140(89)80267-X
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733826858</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>003991408980267X</els_id><sourcerecordid>733826858</sourcerecordid><originalsourceid>FETCH-LOGICAL-c303t-dcaaf39adcca1145cf214411d8bf7970d72146dd2e11c2524c226763b8064473</originalsourceid><addsrcrecordid>eNp9kM1q3DAUhUVoSSY_bxCKFoUkC7eSpbHkTaGE_BQC3WSRndBI17GKLU0kuc1s8uyVM0OyCwgugu-ee_gQOqXkGyW0-U4Ia6uWcnIu2wtJ6kZUD3toQaVgFVsK9gkt3pADdJjSH0JIzQjbRwdUtg0Xki_Qy_UwhRhGyNEZbCFDHJ3X2QWPQ4enqL2bRqy9xXnyjymDx_9c7nGo-o2N4XnzOp4m54OHdZ97PYDzuLzcA15HSOANzFkFqEpsOZOm2GmTtc_H6HOnhwQnu3mE7q-v7i9vq7vfN78uf95VphTOlTVad6zV1hhNKV-arqacU2rlqhOtIFaUf2NtDZSaellzUxcfDVtJ0nAu2BE628au56qQshpdMjAM2kOYkhKMybqRS1lIviVNDClF6NQ6ulHHjaJEzd7VLFXNUpVs1at39VDWvuwOTKsR7PvSTnQBvu4AnYweuuLVuPTGCUakaGfsxxaDIuOvg6iScbNA6yKYrGxwHxf5D2GgojY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733826858</pqid></control><display><type>article</type><title>Fluorometric determination of uranium and tungsten with o-hydroxyhydroquinonephthalein in the presence of non-ionic surfactant</title><source>Access via ScienceDirect (Elsevier)</source><creator>Mori, Itsuo ; Fujita, Yoshikazu ; Ikuta, Kimiko ; Nakahashi, Yoshihiro ; Kakimi, Etsuko ; Kato, Keiji</creator><creatorcontrib>Mori, Itsuo ; Fujita, Yoshikazu ; Ikuta, Kimiko ; Nakahashi, Yoshihiro ; Kakimi, Etsuko ; Kato, Keiji</creatorcontrib><description>Complex formation between uranium or tungsten and o-hydroxyhydroquinonephthalein (Qnph) in various micellar surfactant media has been investigated fluorometrically, and determination of uranium and tungsten based on the difference between the relative fluorescence intensities of Qnph and the metal complex at 535 nm, with excitation at 400 nm in the presence of poly(vinyl) alcohol as a non-ionic surfactant. The calibration curves were linear up to 1.0 μ/ml uranium and 0.9, μ/ml tungsten. The relative standard deviations (5 replicates) were 2.6% for tungsten and 3.0% for uranium, and recovery tests gave relatively good results (97–104%).</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/0039-9140(89)80267-X</identifier><identifier>PMID: 18964784</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analysing. Testing. Standards ; Analytical chemistry ; Applied sciences ; Chemistry ; Cross-disciplinary physics: materials science; rheology ; Exact sciences and technology ; Materials science ; Materials testing ; Metals. Metallurgy ; Physics ; Spectrometric and optical methods</subject><ispartof>Talanta (Oxford), 1989-06, Vol.36 (6), p.688-690</ispartof><rights>1989</rights><rights>1989 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c303t-dcaaf39adcca1145cf214411d8bf7970d72146dd2e11c2524c226763b8064473</citedby><cites>FETCH-LOGICAL-c303t-dcaaf39adcca1145cf214411d8bf7970d72146dd2e11c2524c226763b8064473</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0039-9140(89)80267-X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=7308794$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18964784$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mori, Itsuo</creatorcontrib><creatorcontrib>Fujita, Yoshikazu</creatorcontrib><creatorcontrib>Ikuta, Kimiko</creatorcontrib><creatorcontrib>Nakahashi, Yoshihiro</creatorcontrib><creatorcontrib>Kakimi, Etsuko</creatorcontrib><creatorcontrib>Kato, Keiji</creatorcontrib><title>Fluorometric determination of uranium and tungsten with o-hydroxyhydroquinonephthalein in the presence of non-ionic surfactant</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Complex formation between uranium or tungsten and o-hydroxyhydroquinonephthalein (Qnph) in various micellar surfactant media has been investigated fluorometrically, and determination of uranium and tungsten based on the difference between the relative fluorescence intensities of Qnph and the metal complex at 535 nm, with excitation at 400 nm in the presence of poly(vinyl) alcohol as a non-ionic surfactant. The calibration curves were linear up to 1.0 μ/ml uranium and 0.9, μ/ml tungsten. The relative standard deviations (5 replicates) were 2.6% for tungsten and 3.0% for uranium, and recovery tests gave relatively good results (97–104%).</description><subject>Analysing. Testing. Standards</subject><subject>Analytical chemistry</subject><subject>Applied sciences</subject><subject>Chemistry</subject><subject>Cross-disciplinary physics: materials science; rheology</subject><subject>Exact sciences and technology</subject><subject>Materials science</subject><subject>Materials testing</subject><subject>Metals. Metallurgy</subject><subject>Physics</subject><subject>Spectrometric and optical methods</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><recordid>eNp9kM1q3DAUhUVoSSY_bxCKFoUkC7eSpbHkTaGE_BQC3WSRndBI17GKLU0kuc1s8uyVM0OyCwgugu-ee_gQOqXkGyW0-U4Ia6uWcnIu2wtJ6kZUD3toQaVgFVsK9gkt3pADdJjSH0JIzQjbRwdUtg0Xki_Qy_UwhRhGyNEZbCFDHJ3X2QWPQ4enqL2bRqy9xXnyjymDx_9c7nGo-o2N4XnzOp4m54OHdZ97PYDzuLzcA15HSOANzFkFqEpsOZOm2GmTtc_H6HOnhwQnu3mE7q-v7i9vq7vfN78uf95VphTOlTVad6zV1hhNKV-arqacU2rlqhOtIFaUf2NtDZSaellzUxcfDVtJ0nAu2BE628au56qQshpdMjAM2kOYkhKMybqRS1lIviVNDClF6NQ6ulHHjaJEzd7VLFXNUpVs1at39VDWvuwOTKsR7PvSTnQBvu4AnYweuuLVuPTGCUakaGfsxxaDIuOvg6iScbNA6yKYrGxwHxf5D2GgojY</recordid><startdate>198906</startdate><enddate>198906</enddate><creator>Mori, Itsuo</creator><creator>Fujita, Yoshikazu</creator><creator>Ikuta, Kimiko</creator><creator>Nakahashi, Yoshihiro</creator><creator>Kakimi, Etsuko</creator><creator>Kato, Keiji</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198906</creationdate><title>Fluorometric determination of uranium and tungsten with o-hydroxyhydroquinonephthalein in the presence of non-ionic surfactant</title><author>Mori, Itsuo ; Fujita, Yoshikazu ; Ikuta, Kimiko ; Nakahashi, Yoshihiro ; Kakimi, Etsuko ; Kato, Keiji</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c303t-dcaaf39adcca1145cf214411d8bf7970d72146dd2e11c2524c226763b8064473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Analysing. Testing. Standards</topic><topic>Analytical chemistry</topic><topic>Applied sciences</topic><topic>Chemistry</topic><topic>Cross-disciplinary physics: materials science; rheology</topic><topic>Exact sciences and technology</topic><topic>Materials science</topic><topic>Materials testing</topic><topic>Metals. Metallurgy</topic><topic>Physics</topic><topic>Spectrometric and optical methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mori, Itsuo</creatorcontrib><creatorcontrib>Fujita, Yoshikazu</creatorcontrib><creatorcontrib>Ikuta, Kimiko</creatorcontrib><creatorcontrib>Nakahashi, Yoshihiro</creatorcontrib><creatorcontrib>Kakimi, Etsuko</creatorcontrib><creatorcontrib>Kato, Keiji</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mori, Itsuo</au><au>Fujita, Yoshikazu</au><au>Ikuta, Kimiko</au><au>Nakahashi, Yoshihiro</au><au>Kakimi, Etsuko</au><au>Kato, Keiji</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fluorometric determination of uranium and tungsten with o-hydroxyhydroquinonephthalein in the presence of non-ionic surfactant</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>1989-06</date><risdate>1989</risdate><volume>36</volume><issue>6</issue><spage>688</spage><epage>690</epage><pages>688-690</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>Complex formation between uranium or tungsten and o-hydroxyhydroquinonephthalein (Qnph) in various micellar surfactant media has been investigated fluorometrically, and determination of uranium and tungsten based on the difference between the relative fluorescence intensities of Qnph and the metal complex at 535 nm, with excitation at 400 nm in the presence of poly(vinyl) alcohol as a non-ionic surfactant. The calibration curves were linear up to 1.0 μ/ml uranium and 0.9, μ/ml tungsten. The relative standard deviations (5 replicates) were 2.6% for tungsten and 3.0% for uranium, and recovery tests gave relatively good results (97–104%).</abstract><cop>Amsterdam</cop><cop>Oxford</cop><pub>Elsevier B.V</pub><pmid>18964784</pmid><doi>10.1016/0039-9140(89)80267-X</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 1989-06, Vol.36 (6), p.688-690
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733826858
source Access via ScienceDirect (Elsevier)
subjects Analysing. Testing. Standards
Analytical chemistry
Applied sciences
Chemistry
Cross-disciplinary physics: materials science
rheology
Exact sciences and technology
Materials science
Materials testing
Metals. Metallurgy
Physics
Spectrometric and optical methods
title Fluorometric determination of uranium and tungsten with o-hydroxyhydroquinonephthalein in the presence of non-ionic surfactant
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T03%3A29%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fluorometric%20determination%20of%20uranium%20and%20tungsten%20with%20o-hydroxyhydroquinonephthalein%20in%20the%20presence%20of%20non-ionic%20surfactant&rft.jtitle=Talanta%20(Oxford)&rft.au=Mori,%20Itsuo&rft.date=1989-06&rft.volume=36&rft.issue=6&rft.spage=688&rft.epage=690&rft.pages=688-690&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/0039-9140(89)80267-X&rft_dat=%3Cproquest_cross%3E733826858%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733826858&rft_id=info:pmid/18964784&rft_els_id=003991408980267X&rfr_iscdi=true