Determination of hexavalent chromium and accompanying anions in one run using isocratic ion chromatography with column switching

A method for the simultaneous determination of hexavalent chromium and other inorganic anions like chloride, nitrate and sulfate in aqueous solutions was developed using isocratic ion chromatography with suppressed conductometric detection and column switching. Owing to the large differences in dist...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 1994-07, Vol.41 (7), p.1101-1106
Hauptverfasser: Umile, C., Huber, J.F.K.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1106
container_issue 7
container_start_page 1101
container_title Talanta (Oxford)
container_volume 41
creator Umile, C.
Huber, J.F.K.
description A method for the simultaneous determination of hexavalent chromium and other inorganic anions like chloride, nitrate and sulfate in aqueous solutions was developed using isocratic ion chromatography with suppressed conductometric detection and column switching. Owing to the large differences in distribution coefficient between chromate and the other species, the chromate is separated from the other anions in a first short column, whereas the other anions are led to a longer second column via a column-switching valve, and separated there. Using standard anion separation conditions the length of the columns and the switching procedure were optimized. The time of analysis for eight anions is less than 12 min and the method can be easily automated. Detection limit and precision are not effected by the switching procedure.
doi_str_mv 10.1016/0039-9140(94)80078-2
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733825606</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0039914094800782</els_id><sourcerecordid>733825606</sourcerecordid><originalsourceid>FETCH-LOGICAL-c388t-1eda7eaf8808960fcb9aa044ef38f7d4e7310dbd8c515d3907c888154ec818a53</originalsourceid><addsrcrecordid>eNp9kE1v1DAQhi0EotvCP0DIByTgEBivndi5IKFSPqRKXOBseSeTxiixFzsp7I2fjtNdlRsna0bP-3r0MPZMwBsBonkLINuqFQpeteq1AdCm2j5gG2G0rGSt5UO2uUfO2HnOPwBgK0E-ZmfCtE0DSm7Ynw80U5p8cLOPgceeD_Tb3bqRwsxxSHHyy8Rd6LhDjNPehYMPN2VR6Mx9SQTiaQl8yeve54ipVCFf2-7ybo43ye2HA__l54FjHJcp8FwGHErkCXvUuzHT09N7wb5_vPp2-bm6_vrpy-X76wqlMXMlqHOaXG8MlNuhx13rHChFvTS97hRpKaDbdQZrUXeyBY3GGFErQiOMq-UFe3ns3af4c6E828lnpHF0geKSrZbSbOsGmkKqI4kp5pyot_vkJ5cOVoBd1dvVq1292lbZO_V2W2LPTx8su4m6f6GT6wK8OAEuoxv75AL6fM8poVsFumDvjhgVG7eeks3oKSB1PhHOtov-_4f8BY5Iors</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733825606</pqid></control><display><type>article</type><title>Determination of hexavalent chromium and accompanying anions in one run using isocratic ion chromatography with column switching</title><source>Elsevier ScienceDirect Journals</source><creator>Umile, C. ; Huber, J.F.K.</creator><creatorcontrib>Umile, C. ; Huber, J.F.K.</creatorcontrib><description>A method for the simultaneous determination of hexavalent chromium and other inorganic anions like chloride, nitrate and sulfate in aqueous solutions was developed using isocratic ion chromatography with suppressed conductometric detection and column switching. Owing to the large differences in distribution coefficient between chromate and the other species, the chromate is separated from the other anions in a first short column, whereas the other anions are led to a longer second column via a column-switching valve, and separated there. Using standard anion separation conditions the length of the columns and the switching procedure were optimized. The time of analysis for eight anions is less than 12 min and the method can be easily automated. Detection limit and precision are not effected by the switching procedure.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/0039-9140(94)80078-2</identifier><identifier>PMID: 18966043</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Exact sciences and technology ; Other chromatographic methods</subject><ispartof>Talanta (Oxford), 1994-07, Vol.41 (7), p.1101-1106</ispartof><rights>1994</rights><rights>1994 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c388t-1eda7eaf8808960fcb9aa044ef38f7d4e7310dbd8c515d3907c888154ec818a53</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0039914094800782$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4179407$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18966043$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Umile, C.</creatorcontrib><creatorcontrib>Huber, J.F.K.</creatorcontrib><title>Determination of hexavalent chromium and accompanying anions in one run using isocratic ion chromatography with column switching</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>A method for the simultaneous determination of hexavalent chromium and other inorganic anions like chloride, nitrate and sulfate in aqueous solutions was developed using isocratic ion chromatography with suppressed conductometric detection and column switching. Owing to the large differences in distribution coefficient between chromate and the other species, the chromate is separated from the other anions in a first short column, whereas the other anions are led to a longer second column via a column-switching valve, and separated there. Using standard anion separation conditions the length of the columns and the switching procedure were optimized. The time of analysis for eight anions is less than 12 min and the method can be easily automated. Detection limit and precision are not effected by the switching procedure.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Exact sciences and technology</subject><subject>Other chromatographic methods</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNp9kE1v1DAQhi0EotvCP0DIByTgEBivndi5IKFSPqRKXOBseSeTxiixFzsp7I2fjtNdlRsna0bP-3r0MPZMwBsBonkLINuqFQpeteq1AdCm2j5gG2G0rGSt5UO2uUfO2HnOPwBgK0E-ZmfCtE0DSm7Ynw80U5p8cLOPgceeD_Tb3bqRwsxxSHHyy8Rd6LhDjNPehYMPN2VR6Mx9SQTiaQl8yeve54ipVCFf2-7ybo43ye2HA__l54FjHJcp8FwGHErkCXvUuzHT09N7wb5_vPp2-bm6_vrpy-X76wqlMXMlqHOaXG8MlNuhx13rHChFvTS97hRpKaDbdQZrUXeyBY3GGFErQiOMq-UFe3ns3af4c6E828lnpHF0geKSrZbSbOsGmkKqI4kp5pyot_vkJ5cOVoBd1dvVq1292lbZO_V2W2LPTx8su4m6f6GT6wK8OAEuoxv75AL6fM8poVsFumDvjhgVG7eeks3oKSB1PhHOtov-_4f8BY5Iors</recordid><startdate>19940701</startdate><enddate>19940701</enddate><creator>Umile, C.</creator><creator>Huber, J.F.K.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19940701</creationdate><title>Determination of hexavalent chromium and accompanying anions in one run using isocratic ion chromatography with column switching</title><author>Umile, C. ; Huber, J.F.K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c388t-1eda7eaf8808960fcb9aa044ef38f7d4e7310dbd8c515d3907c888154ec818a53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Exact sciences and technology</topic><topic>Other chromatographic methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Umile, C.</creatorcontrib><creatorcontrib>Huber, J.F.K.</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Umile, C.</au><au>Huber, J.F.K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of hexavalent chromium and accompanying anions in one run using isocratic ion chromatography with column switching</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>1994-07-01</date><risdate>1994</risdate><volume>41</volume><issue>7</issue><spage>1101</spage><epage>1106</epage><pages>1101-1106</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>A method for the simultaneous determination of hexavalent chromium and other inorganic anions like chloride, nitrate and sulfate in aqueous solutions was developed using isocratic ion chromatography with suppressed conductometric detection and column switching. Owing to the large differences in distribution coefficient between chromate and the other species, the chromate is separated from the other anions in a first short column, whereas the other anions are led to a longer second column via a column-switching valve, and separated there. Using standard anion separation conditions the length of the columns and the switching procedure were optimized. The time of analysis for eight anions is less than 12 min and the method can be easily automated. Detection limit and precision are not effected by the switching procedure.</abstract><cop>Amsterdam</cop><cop>Oxford</cop><pub>Elsevier B.V</pub><pmid>18966043</pmid><doi>10.1016/0039-9140(94)80078-2</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 1994-07, Vol.41 (7), p.1101-1106
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733825606
source Elsevier ScienceDirect Journals
subjects Analytical chemistry
Chemistry
Chromatographic methods and physical methods associated with chromatography
Exact sciences and technology
Other chromatographic methods
title Determination of hexavalent chromium and accompanying anions in one run using isocratic ion chromatography with column switching
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T16%3A45%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20hexavalent%20chromium%20and%20accompanying%20anions%20in%20one%20run%20using%20isocratic%20ion%20chromatography%20with%20column%20switching&rft.jtitle=Talanta%20(Oxford)&rft.au=Umile,%20C.&rft.date=1994-07-01&rft.volume=41&rft.issue=7&rft.spage=1101&rft.epage=1106&rft.pages=1101-1106&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/0039-9140(94)80078-2&rft_dat=%3Cproquest_cross%3E733825606%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733825606&rft_id=info:pmid/18966043&rft_els_id=0039914094800782&rfr_iscdi=true