Radiotracer studies on calcium ion-selective electrode membranes based on poly(vinyl chloride) matrices

Radiotracer studies with 45Ca and 36Cl demonstrate that PVC matrix membranes containing Orion 92-20-02 liquid calcium ion-exchanger are permselective to counter-cations. Diffusion coefficients are quoted for the migration of 45Ca between pairs of calcium solutions and are discussed in terms of solut...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 1976-11, Vol.23 (11), p.799-804
Hauptverfasser: Craggs, A., Moody, G.J., Thomas, J.D.R., Willcox, Anne
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 804
container_issue 11
container_start_page 799
container_title Talanta (Oxford)
container_volume 23
creator Craggs, A.
Moody, G.J.
Thomas, J.D.R.
Willcox, Anne
description Radiotracer studies with 45Ca and 36Cl demonstrate that PVC matrix membranes containing Orion 92-20-02 liquid calcium ion-exchanger are permselective to counter-cations. Diffusion coefficients are quoted for the migration of 45Ca between pairs of calcium solutions and are discussed in terms of solution concentration, membrane thickness and concentration level of sensor in the membrane. Migration of calcium ions from calcium chloride solution to a Group (II) metal chloride solution through a PVC membrane containing calcium liquid ion-exchanger is discussed in terms of solvent extraction and electrode selectivity coefficient parameters. Thus, magnesium, strontium and barium ions appear to inhibit migration through the membrane by their low affinity for the membrane liquid ion-exchanger sites, while the inhibition by beryllium ions is attributed to site blockage by the strong affinity of dialkylphosphate sites for beryllium.
doi_str_mv 10.1016/0039-9140(76)80089-6
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733823414</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0039914076800896</els_id><sourcerecordid>733823414</sourcerecordid><originalsourceid>FETCH-LOGICAL-c274t-39be5f8decb8b42c85791e881dd1fe197d8c3ada6c39b028545398348826f0d43</originalsourceid><addsrcrecordid>eNp9kMtKxDAUhoMoOo6-gUh3ziyqSdPmshFk8AYDgug6pMmpRtpmTNqBeXvbmUF3rs5ZfP-5fAhdEHxNMGE3GFOZSpLjGWdzgbGQKTtAEyI4TWnB6SGa_CIn6DTGL4xxRjE9RidESEakKCbo41Vb57ugDYQkdr11EBPfJkbXxvVN4nybRqjBdG4NybYJ3kLSQFMG3Q5wqSPYMbLy9Wa2du2mTsxn7YOzME8a3QVnIJ6ho0rXEc73dYreH-7fFk_p8uXxeXG3TE3G8y6lsoSiEhZMKco8M6LgkoAQxFpSAZHcCkO11cwMJM5EkRdUCpoLkbEK25xO0dVu7ir47x5ipxoXDdT1cKvvo-KUiozmZCTzHWmCjzFApVbBNTpsFMFqNKxGfWrUpzhTW8OKDbHL_YK-bMD-hfZKB-B2B8Dw5tpBUNE4aA1YFwZ7ynr3_4YfsVWL0w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733823414</pqid></control><display><type>article</type><title>Radiotracer studies on calcium ion-selective electrode membranes based on poly(vinyl chloride) matrices</title><source>Elsevier ScienceDirect Journals</source><creator>Craggs, A. ; Moody, G.J. ; Thomas, J.D.R. ; Willcox, Anne</creator><creatorcontrib>Craggs, A. ; Moody, G.J. ; Thomas, J.D.R. ; Willcox, Anne</creatorcontrib><description>Radiotracer studies with 45Ca and 36Cl demonstrate that PVC matrix membranes containing Orion 92-20-02 liquid calcium ion-exchanger are permselective to counter-cations. Diffusion coefficients are quoted for the migration of 45Ca between pairs of calcium solutions and are discussed in terms of solution concentration, membrane thickness and concentration level of sensor in the membrane. Migration of calcium ions from calcium chloride solution to a Group (II) metal chloride solution through a PVC membrane containing calcium liquid ion-exchanger is discussed in terms of solvent extraction and electrode selectivity coefficient parameters. Thus, magnesium, strontium and barium ions appear to inhibit migration through the membrane by their low affinity for the membrane liquid ion-exchanger sites, while the inhibition by beryllium ions is attributed to site blockage by the strong affinity of dialkylphosphate sites for beryllium.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/0039-9140(76)80089-6</identifier><identifier>PMID: 18961985</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><ispartof>Talanta (Oxford), 1976-11, Vol.23 (11), p.799-804</ispartof><rights>1976</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c274t-39be5f8decb8b42c85791e881dd1fe197d8c3ada6c39b028545398348826f0d43</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0039914076800896$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18961985$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Craggs, A.</creatorcontrib><creatorcontrib>Moody, G.J.</creatorcontrib><creatorcontrib>Thomas, J.D.R.</creatorcontrib><creatorcontrib>Willcox, Anne</creatorcontrib><title>Radiotracer studies on calcium ion-selective electrode membranes based on poly(vinyl chloride) matrices</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Radiotracer studies with 45Ca and 36Cl demonstrate that PVC matrix membranes containing Orion 92-20-02 liquid calcium ion-exchanger are permselective to counter-cations. Diffusion coefficients are quoted for the migration of 45Ca between pairs of calcium solutions and are discussed in terms of solution concentration, membrane thickness and concentration level of sensor in the membrane. Migration of calcium ions from calcium chloride solution to a Group (II) metal chloride solution through a PVC membrane containing calcium liquid ion-exchanger is discussed in terms of solvent extraction and electrode selectivity coefficient parameters. Thus, magnesium, strontium and barium ions appear to inhibit migration through the membrane by their low affinity for the membrane liquid ion-exchanger sites, while the inhibition by beryllium ions is attributed to site blockage by the strong affinity of dialkylphosphate sites for beryllium.</description><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1976</creationdate><recordtype>article</recordtype><recordid>eNp9kMtKxDAUhoMoOo6-gUh3ziyqSdPmshFk8AYDgug6pMmpRtpmTNqBeXvbmUF3rs5ZfP-5fAhdEHxNMGE3GFOZSpLjGWdzgbGQKTtAEyI4TWnB6SGa_CIn6DTGL4xxRjE9RidESEakKCbo41Vb57ugDYQkdr11EBPfJkbXxvVN4nybRqjBdG4NybYJ3kLSQFMG3Q5wqSPYMbLy9Wa2du2mTsxn7YOzME8a3QVnIJ6ho0rXEc73dYreH-7fFk_p8uXxeXG3TE3G8y6lsoSiEhZMKco8M6LgkoAQxFpSAZHcCkO11cwMJM5EkRdUCpoLkbEK25xO0dVu7ir47x5ipxoXDdT1cKvvo-KUiozmZCTzHWmCjzFApVbBNTpsFMFqNKxGfWrUpzhTW8OKDbHL_YK-bMD-hfZKB-B2B8Dw5tpBUNE4aA1YFwZ7ynr3_4YfsVWL0w</recordid><startdate>197611</startdate><enddate>197611</enddate><creator>Craggs, A.</creator><creator>Moody, G.J.</creator><creator>Thomas, J.D.R.</creator><creator>Willcox, Anne</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>197611</creationdate><title>Radiotracer studies on calcium ion-selective electrode membranes based on poly(vinyl chloride) matrices</title><author>Craggs, A. ; Moody, G.J. ; Thomas, J.D.R. ; Willcox, Anne</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c274t-39be5f8decb8b42c85791e881dd1fe197d8c3ada6c39b028545398348826f0d43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1976</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Craggs, A.</creatorcontrib><creatorcontrib>Moody, G.J.</creatorcontrib><creatorcontrib>Thomas, J.D.R.</creatorcontrib><creatorcontrib>Willcox, Anne</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Craggs, A.</au><au>Moody, G.J.</au><au>Thomas, J.D.R.</au><au>Willcox, Anne</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radiotracer studies on calcium ion-selective electrode membranes based on poly(vinyl chloride) matrices</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>1976-11</date><risdate>1976</risdate><volume>23</volume><issue>11</issue><spage>799</spage><epage>804</epage><pages>799-804</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>Radiotracer studies with 45Ca and 36Cl demonstrate that PVC matrix membranes containing Orion 92-20-02 liquid calcium ion-exchanger are permselective to counter-cations. Diffusion coefficients are quoted for the migration of 45Ca between pairs of calcium solutions and are discussed in terms of solution concentration, membrane thickness and concentration level of sensor in the membrane. Migration of calcium ions from calcium chloride solution to a Group (II) metal chloride solution through a PVC membrane containing calcium liquid ion-exchanger is discussed in terms of solvent extraction and electrode selectivity coefficient parameters. Thus, magnesium, strontium and barium ions appear to inhibit migration through the membrane by their low affinity for the membrane liquid ion-exchanger sites, while the inhibition by beryllium ions is attributed to site blockage by the strong affinity of dialkylphosphate sites for beryllium.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>18961985</pmid><doi>10.1016/0039-9140(76)80089-6</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 1976-11, Vol.23 (11), p.799-804
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733823414
source Elsevier ScienceDirect Journals
title Radiotracer studies on calcium ion-selective electrode membranes based on poly(vinyl chloride) matrices
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T15%3A13%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radiotracer%20studies%20on%20calcium%20ion-selective%20electrode%20membranes%20based%20on%20poly(vinyl%20chloride)%20matrices&rft.jtitle=Talanta%20(Oxford)&rft.au=Craggs,%20A.&rft.date=1976-11&rft.volume=23&rft.issue=11&rft.spage=799&rft.epage=804&rft.pages=799-804&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/0039-9140(76)80089-6&rft_dat=%3Cproquest_cross%3E733823414%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733823414&rft_id=info:pmid/18961985&rft_els_id=0039914076800896&rfr_iscdi=true