4-Amino-3-methyl-5-mercapto-1,2,4-triazole as a gravimetric reagent for determination of silver in silver compounds, alloys and complexes

A simple, convenient and accurate gravimetric method for the determination of silver is presented. 4-Amino-3-methyl-5-mercapto-1,2,4-triazole precipitates silver quantitatively from ammoniacal tartrate medium. The complex is weighed as AgC 3H 5N 4S after drying at 120–30°. Separation of silver from...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 1978-07, Vol.25 (7), p.418-420
Hauptverfasser: Gadag, R.V., Gajendragad®, M.R.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 420
container_issue 7
container_start_page 418
container_title Talanta (Oxford)
container_volume 25
creator Gadag, R.V.
Gajendragad®, M.R.
description A simple, convenient and accurate gravimetric method for the determination of silver is presented. 4-Amino-3-methyl-5-mercapto-1,2,4-triazole precipitates silver quantitatively from ammoniacal tartrate medium. The complex is weighed as AgC 3H 5N 4S after drying at 120–30°. Separation of silver from a large number of cations is described. Application of the method for quantitative analysis of alloys and complexes of silver is reported. The average relative error for the range 20–70 mg of silver is ± 0.25% and the relative standard deviation at the 40-mg level is 0.2%.
doi_str_mv 10.1016/0039-9140(78)80129-5
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733821768</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0039914078801295</els_id><sourcerecordid>733821768</sourcerecordid><originalsourceid>FETCH-LOGICAL-c390t-6ba5d963a81dfe6eade23aa6d133731e49084f935f31fddb279de85635f18a353</originalsourceid><addsrcrecordid>eNp9kV1vVCEQhonR2G31HxjDldZkUThzPuDGpGn8aNKkN3pNWJhTMZzDCuzG7T_wX5ftrnrXC8Jk8vAOmYeQV4K_F1z0HzgHxZRo-fkg30kuGsW6J2Qh5AAMugGeksU_5ISc5vyTc94Ah-fkREjVN40SC_KnZReTnyMDNmH5sQusq0WyZl0iE8tm2bKSvLmLAanJ1NDbZLa-oslbmtDc4lzoGBN1WDDVJFN8nGkcafZhi4n6-W9l47SOm9nlJTUhxF1Nm91DN-BvzC_Is9GEjC-P9xn5_vnTt8uv7Prmy9XlxTWzoHhh_cp0TvVgpHAj9mgcNmBM7wTAAAJbxWU7KuhGEKNzq2ZQDmXX14aQBjo4I28PuesUf20wFz35bDEEM2PcZD0AyEYMvazkm0fJukw-1FPB9gDaFHNOOOp18pNJOy243svSexN6b0IPUj_I0vufvD7mb1YTuv-PjnYq8PEAYN3H1mPS2XqcLTqf0Bbton98wj1jaaQl</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>23007300</pqid></control><display><type>article</type><title>4-Amino-3-methyl-5-mercapto-1,2,4-triazole as a gravimetric reagent for determination of silver in silver compounds, alloys and complexes</title><source>Elsevier ScienceDirect Journals Complete</source><creator>Gadag, R.V. ; Gajendragad®, M.R.</creator><creatorcontrib>Gadag, R.V. ; Gajendragad®, M.R.</creatorcontrib><description>A simple, convenient and accurate gravimetric method for the determination of silver is presented. 4-Amino-3-methyl-5-mercapto-1,2,4-triazole precipitates silver quantitatively from ammoniacal tartrate medium. The complex is weighed as AgC 3H 5N 4S after drying at 120–30°. Separation of silver from a large number of cations is described. Application of the method for quantitative analysis of alloys and complexes of silver is reported. The average relative error for the range 20–70 mg of silver is ± 0.25% and the relative standard deviation at the 40-mg level is 0.2%.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/0039-9140(78)80129-5</identifier><identifier>PMID: 18962291</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><ispartof>Talanta (Oxford), 1978-07, Vol.25 (7), p.418-420</ispartof><rights>1978</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c390t-6ba5d963a81dfe6eade23aa6d133731e49084f935f31fddb279de85635f18a353</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0039-9140(78)80129-5$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18962291$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gadag, R.V.</creatorcontrib><creatorcontrib>Gajendragad®, M.R.</creatorcontrib><title>4-Amino-3-methyl-5-mercapto-1,2,4-triazole as a gravimetric reagent for determination of silver in silver compounds, alloys and complexes</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>A simple, convenient and accurate gravimetric method for the determination of silver is presented. 4-Amino-3-methyl-5-mercapto-1,2,4-triazole precipitates silver quantitatively from ammoniacal tartrate medium. The complex is weighed as AgC 3H 5N 4S after drying at 120–30°. Separation of silver from a large number of cations is described. Application of the method for quantitative analysis of alloys and complexes of silver is reported. The average relative error for the range 20–70 mg of silver is ± 0.25% and the relative standard deviation at the 40-mg level is 0.2%.</description><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1978</creationdate><recordtype>article</recordtype><recordid>eNp9kV1vVCEQhonR2G31HxjDldZkUThzPuDGpGn8aNKkN3pNWJhTMZzDCuzG7T_wX5ftrnrXC8Jk8vAOmYeQV4K_F1z0HzgHxZRo-fkg30kuGsW6J2Qh5AAMugGeksU_5ISc5vyTc94Ah-fkREjVN40SC_KnZReTnyMDNmH5sQusq0WyZl0iE8tm2bKSvLmLAanJ1NDbZLa-oslbmtDc4lzoGBN1WDDVJFN8nGkcafZhi4n6-W9l47SOm9nlJTUhxF1Nm91DN-BvzC_Is9GEjC-P9xn5_vnTt8uv7Prmy9XlxTWzoHhh_cp0TvVgpHAj9mgcNmBM7wTAAAJbxWU7KuhGEKNzq2ZQDmXX14aQBjo4I28PuesUf20wFz35bDEEM2PcZD0AyEYMvazkm0fJukw-1FPB9gDaFHNOOOp18pNJOy243svSexN6b0IPUj_I0vufvD7mb1YTuv-PjnYq8PEAYN3H1mPS2XqcLTqf0Bbton98wj1jaaQl</recordid><startdate>197807</startdate><enddate>197807</enddate><creator>Gadag, R.V.</creator><creator>Gajendragad®, M.R.</creator><general>Elsevier B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>7X8</scope></search><sort><creationdate>197807</creationdate><title>4-Amino-3-methyl-5-mercapto-1,2,4-triazole as a gravimetric reagent for determination of silver in silver compounds, alloys and complexes</title><author>Gadag, R.V. ; Gajendragad®, M.R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c390t-6ba5d963a81dfe6eade23aa6d133731e49084f935f31fddb279de85635f18a353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1978</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gadag, R.V.</creatorcontrib><creatorcontrib>Gajendragad®, M.R.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gadag, R.V.</au><au>Gajendragad®, M.R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>4-Amino-3-methyl-5-mercapto-1,2,4-triazole as a gravimetric reagent for determination of silver in silver compounds, alloys and complexes</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>1978-07</date><risdate>1978</risdate><volume>25</volume><issue>7</issue><spage>418</spage><epage>420</epage><pages>418-420</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><abstract>A simple, convenient and accurate gravimetric method for the determination of silver is presented. 4-Amino-3-methyl-5-mercapto-1,2,4-triazole precipitates silver quantitatively from ammoniacal tartrate medium. The complex is weighed as AgC 3H 5N 4S after drying at 120–30°. Separation of silver from a large number of cations is described. Application of the method for quantitative analysis of alloys and complexes of silver is reported. The average relative error for the range 20–70 mg of silver is ± 0.25% and the relative standard deviation at the 40-mg level is 0.2%.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>18962291</pmid><doi>10.1016/0039-9140(78)80129-5</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0039-9140
ispartof Talanta (Oxford), 1978-07, Vol.25 (7), p.418-420
issn 0039-9140
1873-3573
language eng
recordid cdi_proquest_miscellaneous_733821768
source Elsevier ScienceDirect Journals Complete
title 4-Amino-3-methyl-5-mercapto-1,2,4-triazole as a gravimetric reagent for determination of silver in silver compounds, alloys and complexes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T15%3A59%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=4-Amino-3-methyl-5-mercapto-1,2,4-triazole%20as%20a%20gravimetric%20reagent%20for%20determination%20of%20silver%20in%20silver%20compounds,%20alloys%20and%20complexes&rft.jtitle=Talanta%20(Oxford)&rft.au=Gadag,%20R.V.&rft.date=1978-07&rft.volume=25&rft.issue=7&rft.spage=418&rft.epage=420&rft.pages=418-420&rft.issn=0039-9140&rft.eissn=1873-3573&rft_id=info:doi/10.1016/0039-9140(78)80129-5&rft_dat=%3Cproquest_cross%3E733821768%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=23007300&rft_id=info:pmid/18962291&rft_els_id=0039914078801295&rfr_iscdi=true