Fiber coupling using graded-index rod lenses

The graded-index rod lens (GRIN lens) is useful in coupling between multimode optical fibers. Applications include connectors, switches, multiplexers, and branch couplers. In these devices, one GRIN lens collimates light from an input fiber, and a second lens collects the light and focuses it on an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Optics 1980-06, Vol.19 (12), p.2011-2018
1. Verfasser: Palais, J C
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2018
container_issue 12
container_start_page 2011
container_title Applied Optics
container_volume 19
creator Palais, J C
description The graded-index rod lens (GRIN lens) is useful in coupling between multimode optical fibers. Applications include connectors, switches, multiplexers, and branch couplers. In these devices, one GRIN lens collimates light from an input fiber, and a second lens collects the light and focuses it on an output fiber. This paper presents analyses of power losses in these devices resulting from lateral and angular misalignments and from the spacing between the lenses. It is found that the GRIN lens coupling system is very sensitive to angular alignment but is more tolerant of lateral errors and lens spacing.
doi_str_mv 10.1364/AO.19.002011
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733702865</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733702865</sourcerecordid><originalsourceid>FETCH-LOGICAL-c362t-8ddb7c534c9042ea14e2f4f881859d053bcf2d78235e6055b082af83ed52cd403</originalsourceid><addsrcrecordid>eNp90D1PwzAQBmALgWgpbMwoEyxN8Z3txB6rigJSpS4gsVmJfamC0qTYjQT_nlQFRob7GB69w8vYNfAZiEzez9czMDPOkQOcsDEoYVKpEE8PvzIpoH4bsYsY3zkXSpr8nI2QIwLkYsymy7qkkLiu3zV1u0n6eNibUHjyad16-kxC55OG2kjxkp1VRRPp6udO2Ovy4WXxlK7Wj8-L-Sp1IsN9qr0vc6eEdIZLpAIkYSUrrUEr47kSpavQ5xqFoowrVXKNRaUFeYXOSy4m7O6YuwvdR09xb7d1dNQ0RUtdH20uRM5RZ2qQt_9KFDnAMAOcHqELXYyBKrsL9bYIXxa4PfRo52sLxh57HPjNT25fbsn_4d_ixDd-pWss</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>23711371</pqid></control><display><type>article</type><title>Fiber coupling using graded-index rod lenses</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Palais, J C</creator><creatorcontrib>Palais, J C</creatorcontrib><description>The graded-index rod lens (GRIN lens) is useful in coupling between multimode optical fibers. Applications include connectors, switches, multiplexers, and branch couplers. In these devices, one GRIN lens collimates light from an input fiber, and a second lens collects the light and focuses it on an output fiber. This paper presents analyses of power losses in these devices resulting from lateral and angular misalignments and from the spacing between the lenses. It is found that the GRIN lens coupling system is very sensitive to angular alignment but is more tolerant of lateral errors and lens spacing.</description><identifier>ISSN: 1559-128X</identifier><identifier>ISSN: 0003-6935</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.19.002011</identifier><identifier>PMID: 20221173</identifier><language>eng</language><publisher>United States</publisher><ispartof>Applied Optics, 1980-06, Vol.19 (12), p.2011-2018</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c362t-8ddb7c534c9042ea14e2f4f881859d053bcf2d78235e6055b082af83ed52cd403</citedby><cites>FETCH-LOGICAL-c362t-8ddb7c534c9042ea14e2f4f881859d053bcf2d78235e6055b082af83ed52cd403</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20221173$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Palais, J C</creatorcontrib><title>Fiber coupling using graded-index rod lenses</title><title>Applied Optics</title><addtitle>Appl Opt</addtitle><description>The graded-index rod lens (GRIN lens) is useful in coupling between multimode optical fibers. Applications include connectors, switches, multiplexers, and branch couplers. In these devices, one GRIN lens collimates light from an input fiber, and a second lens collects the light and focuses it on an output fiber. This paper presents analyses of power losses in these devices resulting from lateral and angular misalignments and from the spacing between the lenses. It is found that the GRIN lens coupling system is very sensitive to angular alignment but is more tolerant of lateral errors and lens spacing.</description><issn>1559-128X</issn><issn>0003-6935</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1980</creationdate><recordtype>article</recordtype><recordid>eNp90D1PwzAQBmALgWgpbMwoEyxN8Z3txB6rigJSpS4gsVmJfamC0qTYjQT_nlQFRob7GB69w8vYNfAZiEzez9czMDPOkQOcsDEoYVKpEE8PvzIpoH4bsYsY3zkXSpr8nI2QIwLkYsymy7qkkLiu3zV1u0n6eNibUHjyad16-kxC55OG2kjxkp1VRRPp6udO2Ovy4WXxlK7Wj8-L-Sp1IsN9qr0vc6eEdIZLpAIkYSUrrUEr47kSpavQ5xqFoowrVXKNRaUFeYXOSy4m7O6YuwvdR09xb7d1dNQ0RUtdH20uRM5RZ2qQt_9KFDnAMAOcHqELXYyBKrsL9bYIXxa4PfRo52sLxh57HPjNT25fbsn_4d_ixDd-pWss</recordid><startdate>19800615</startdate><enddate>19800615</enddate><creator>Palais, J C</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QQ</scope><scope>8FD</scope><scope>JG9</scope><scope>7X8</scope></search><sort><creationdate>19800615</creationdate><title>Fiber coupling using graded-index rod lenses</title><author>Palais, J C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c362t-8ddb7c534c9042ea14e2f4f881859d053bcf2d78235e6055b082af83ed52cd403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1980</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Palais, J C</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Ceramic Abstracts</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>MEDLINE - Academic</collection><jtitle>Applied Optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Palais, J C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fiber coupling using graded-index rod lenses</atitle><jtitle>Applied Optics</jtitle><addtitle>Appl Opt</addtitle><date>1980-06-15</date><risdate>1980</risdate><volume>19</volume><issue>12</issue><spage>2011</spage><epage>2018</epage><pages>2011-2018</pages><issn>1559-128X</issn><issn>0003-6935</issn><eissn>1539-4522</eissn><abstract>The graded-index rod lens (GRIN lens) is useful in coupling between multimode optical fibers. Applications include connectors, switches, multiplexers, and branch couplers. In these devices, one GRIN lens collimates light from an input fiber, and a second lens collects the light and focuses it on an output fiber. This paper presents analyses of power losses in these devices resulting from lateral and angular misalignments and from the spacing between the lenses. It is found that the GRIN lens coupling system is very sensitive to angular alignment but is more tolerant of lateral errors and lens spacing.</abstract><cop>United States</cop><pmid>20221173</pmid><doi>10.1364/AO.19.002011</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1559-128X
ispartof Applied Optics, 1980-06, Vol.19 (12), p.2011-2018
issn 1559-128X
0003-6935
1539-4522
language eng
recordid cdi_proquest_miscellaneous_733702865
source Alma/SFX Local Collection; Optica Publishing Group Journals
title Fiber coupling using graded-index rod lenses
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T04%3A57%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fiber%20coupling%20using%20graded-index%20rod%20lenses&rft.jtitle=Applied%20Optics&rft.au=Palais,%20J%20C&rft.date=1980-06-15&rft.volume=19&rft.issue=12&rft.spage=2011&rft.epage=2018&rft.pages=2011-2018&rft.issn=1559-128X&rft.eissn=1539-4522&rft_id=info:doi/10.1364/AO.19.002011&rft_dat=%3Cproquest_cross%3E733702865%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=23711371&rft_id=info:pmid/20221173&rfr_iscdi=true