Circular compartmentalized microfluidic platform: Study of axon-glia interactions

We describe a compartmentalized circular microfluidic platform that enables directed cell placement within defined microenvironments for the study of axon-glia interactions. The multi-compartment platform consists of independent units of radial microchannel arrays that fluidically isolate somal from...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Lab on a chip 2010-01, Vol.10 (6), p.741-747
Hauptverfasser: Hosmane, Suneil, Yang, In Hong, Ruffin, April, Thakor, Nitish, Venkatesan, Arun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 747
container_issue 6
container_start_page 741
container_title Lab on a chip
container_volume 10
creator Hosmane, Suneil
Yang, In Hong
Ruffin, April
Thakor, Nitish
Venkatesan, Arun
description We describe a compartmentalized circular microfluidic platform that enables directed cell placement within defined microenvironments for the study of axon-glia interactions. The multi-compartment platform consists of independent units of radial microchannel arrays that fluidically isolate somal from axonal compartments. Fluidic access ports punched near the microchannels allow for direct pipetting of cells into the device. Adjacent somal or axonal compartments can be readily merged so that independent groups of neurons or axons can be maintained in either separate or uniform microenvironments. We demonstrate three distinct modes of directed cell placement in this device, to suit varying experimental needs for the study of axon-glia interactions: (1) centrifugation of the circular platform can result in a two-fold increase in axonal throughput in microchannels and provides a new technique to establish axon-glia interactions; (2) microstencils can be utilized to directly place glial cells within areas of interest; and (3) intimate axon-glia co-culture can be attained via standard pipetting techniques. We take advantage of this microfluidic platform to demonstrate a two-fold preferential accumulation of microglia specifically near injured CNS axons, an event implicated in the maintenance and progression of a number of chronic neuroinflammatory and neurodegenerative diseases.
doi_str_mv 10.1039/b918640a
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733698197</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733698197</sourcerecordid><originalsourceid>FETCH-LOGICAL-c348t-83e2ca2fced5a38d70f18861a152151ab479606ef9472e76a0b645f309f0f7353</originalsourceid><addsrcrecordid>eNo9kEtLxDAUhYMozjgK_gLpTjfVpGnzcCeDLxgQUdflNk0kkjY1ScHx11uZx-rexcfhnA-hc4KvCabyppFEsBLDAZqTktMcEyEP97_kM3QS4xfGpCqZOEazAhcFqVgxR69LG9ToIGTKdwOE1Ok-gbO_us06q4I3brStVdngIBkfutvsLY3tOvMmgx_f55_OQmb7pAOoZH0fT9GRARf12fYu0MfD_fvyKV-9PD4v71a5oqVIuaC6UFAYpdsKqGg5NkQIRoBUUzUCTcklw0wbWfJCcwa4YWVlKJYGG04rukCXm9wh-O9Rx1R3NirtHPTaj7HmlDIppvETebUhpzkxBm3qIdgOwromuP73V-_8TejFNnRsOt3uwZ0w-gfm32r7</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733698197</pqid></control><display><type>article</type><title>Circular compartmentalized microfluidic platform: Study of axon-glia interactions</title><source>MEDLINE</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Hosmane, Suneil ; Yang, In Hong ; Ruffin, April ; Thakor, Nitish ; Venkatesan, Arun</creator><creatorcontrib>Hosmane, Suneil ; Yang, In Hong ; Ruffin, April ; Thakor, Nitish ; Venkatesan, Arun</creatorcontrib><description>We describe a compartmentalized circular microfluidic platform that enables directed cell placement within defined microenvironments for the study of axon-glia interactions. The multi-compartment platform consists of independent units of radial microchannel arrays that fluidically isolate somal from axonal compartments. Fluidic access ports punched near the microchannels allow for direct pipetting of cells into the device. Adjacent somal or axonal compartments can be readily merged so that independent groups of neurons or axons can be maintained in either separate or uniform microenvironments. We demonstrate three distinct modes of directed cell placement in this device, to suit varying experimental needs for the study of axon-glia interactions: (1) centrifugation of the circular platform can result in a two-fold increase in axonal throughput in microchannels and provides a new technique to establish axon-glia interactions; (2) microstencils can be utilized to directly place glial cells within areas of interest; and (3) intimate axon-glia co-culture can be attained via standard pipetting techniques. We take advantage of this microfluidic platform to demonstrate a two-fold preferential accumulation of microglia specifically near injured CNS axons, an event implicated in the maintenance and progression of a number of chronic neuroinflammatory and neurodegenerative diseases.</description><identifier>ISSN: 1473-0197</identifier><identifier>EISSN: 1473-0189</identifier><identifier>DOI: 10.1039/b918640a</identifier><identifier>PMID: 20221562</identifier><language>eng</language><publisher>England</publisher><subject>Animals ; Axons - physiology ; Cell Communication - physiology ; Cell Separation - instrumentation ; Cells, Cultured ; Coculture Techniques - instrumentation ; Equipment Design ; Equipment Failure Analysis ; Microfluidic Analytical Techniques - instrumentation ; Neuroglia - physiology ; Rats</subject><ispartof>Lab on a chip, 2010-01, Vol.10 (6), p.741-747</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c348t-83e2ca2fced5a38d70f18861a152151ab479606ef9472e76a0b645f309f0f7353</citedby><cites>FETCH-LOGICAL-c348t-83e2ca2fced5a38d70f18861a152151ab479606ef9472e76a0b645f309f0f7353</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20221562$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hosmane, Suneil</creatorcontrib><creatorcontrib>Yang, In Hong</creatorcontrib><creatorcontrib>Ruffin, April</creatorcontrib><creatorcontrib>Thakor, Nitish</creatorcontrib><creatorcontrib>Venkatesan, Arun</creatorcontrib><title>Circular compartmentalized microfluidic platform: Study of axon-glia interactions</title><title>Lab on a chip</title><addtitle>Lab Chip</addtitle><description>We describe a compartmentalized circular microfluidic platform that enables directed cell placement within defined microenvironments for the study of axon-glia interactions. The multi-compartment platform consists of independent units of radial microchannel arrays that fluidically isolate somal from axonal compartments. Fluidic access ports punched near the microchannels allow for direct pipetting of cells into the device. Adjacent somal or axonal compartments can be readily merged so that independent groups of neurons or axons can be maintained in either separate or uniform microenvironments. We demonstrate three distinct modes of directed cell placement in this device, to suit varying experimental needs for the study of axon-glia interactions: (1) centrifugation of the circular platform can result in a two-fold increase in axonal throughput in microchannels and provides a new technique to establish axon-glia interactions; (2) microstencils can be utilized to directly place glial cells within areas of interest; and (3) intimate axon-glia co-culture can be attained via standard pipetting techniques. We take advantage of this microfluidic platform to demonstrate a two-fold preferential accumulation of microglia specifically near injured CNS axons, an event implicated in the maintenance and progression of a number of chronic neuroinflammatory and neurodegenerative diseases.</description><subject>Animals</subject><subject>Axons - physiology</subject><subject>Cell Communication - physiology</subject><subject>Cell Separation - instrumentation</subject><subject>Cells, Cultured</subject><subject>Coculture Techniques - instrumentation</subject><subject>Equipment Design</subject><subject>Equipment Failure Analysis</subject><subject>Microfluidic Analytical Techniques - instrumentation</subject><subject>Neuroglia - physiology</subject><subject>Rats</subject><issn>1473-0197</issn><issn>1473-0189</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kEtLxDAUhYMozjgK_gLpTjfVpGnzcCeDLxgQUdflNk0kkjY1ScHx11uZx-rexcfhnA-hc4KvCabyppFEsBLDAZqTktMcEyEP97_kM3QS4xfGpCqZOEazAhcFqVgxR69LG9ToIGTKdwOE1Ok-gbO_us06q4I3brStVdngIBkfutvsLY3tOvMmgx_f55_OQmb7pAOoZH0fT9GRARf12fYu0MfD_fvyKV-9PD4v71a5oqVIuaC6UFAYpdsKqGg5NkQIRoBUUzUCTcklw0wbWfJCcwa4YWVlKJYGG04rukCXm9wh-O9Rx1R3NirtHPTaj7HmlDIppvETebUhpzkxBm3qIdgOwromuP73V-_8TejFNnRsOt3uwZ0w-gfm32r7</recordid><startdate>20100101</startdate><enddate>20100101</enddate><creator>Hosmane, Suneil</creator><creator>Yang, In Hong</creator><creator>Ruffin, April</creator><creator>Thakor, Nitish</creator><creator>Venkatesan, Arun</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20100101</creationdate><title>Circular compartmentalized microfluidic platform: Study of axon-glia interactions</title><author>Hosmane, Suneil ; Yang, In Hong ; Ruffin, April ; Thakor, Nitish ; Venkatesan, Arun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c348t-83e2ca2fced5a38d70f18861a152151ab479606ef9472e76a0b645f309f0f7353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Animals</topic><topic>Axons - physiology</topic><topic>Cell Communication - physiology</topic><topic>Cell Separation - instrumentation</topic><topic>Cells, Cultured</topic><topic>Coculture Techniques - instrumentation</topic><topic>Equipment Design</topic><topic>Equipment Failure Analysis</topic><topic>Microfluidic Analytical Techniques - instrumentation</topic><topic>Neuroglia - physiology</topic><topic>Rats</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hosmane, Suneil</creatorcontrib><creatorcontrib>Yang, In Hong</creatorcontrib><creatorcontrib>Ruffin, April</creatorcontrib><creatorcontrib>Thakor, Nitish</creatorcontrib><creatorcontrib>Venkatesan, Arun</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Lab on a chip</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hosmane, Suneil</au><au>Yang, In Hong</au><au>Ruffin, April</au><au>Thakor, Nitish</au><au>Venkatesan, Arun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Circular compartmentalized microfluidic platform: Study of axon-glia interactions</atitle><jtitle>Lab on a chip</jtitle><addtitle>Lab Chip</addtitle><date>2010-01-01</date><risdate>2010</risdate><volume>10</volume><issue>6</issue><spage>741</spage><epage>747</epage><pages>741-747</pages><issn>1473-0197</issn><eissn>1473-0189</eissn><abstract>We describe a compartmentalized circular microfluidic platform that enables directed cell placement within defined microenvironments for the study of axon-glia interactions. The multi-compartment platform consists of independent units of radial microchannel arrays that fluidically isolate somal from axonal compartments. Fluidic access ports punched near the microchannels allow for direct pipetting of cells into the device. Adjacent somal or axonal compartments can be readily merged so that independent groups of neurons or axons can be maintained in either separate or uniform microenvironments. We demonstrate three distinct modes of directed cell placement in this device, to suit varying experimental needs for the study of axon-glia interactions: (1) centrifugation of the circular platform can result in a two-fold increase in axonal throughput in microchannels and provides a new technique to establish axon-glia interactions; (2) microstencils can be utilized to directly place glial cells within areas of interest; and (3) intimate axon-glia co-culture can be attained via standard pipetting techniques. We take advantage of this microfluidic platform to demonstrate a two-fold preferential accumulation of microglia specifically near injured CNS axons, an event implicated in the maintenance and progression of a number of chronic neuroinflammatory and neurodegenerative diseases.</abstract><cop>England</cop><pmid>20221562</pmid><doi>10.1039/b918640a</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1473-0197
ispartof Lab on a chip, 2010-01, Vol.10 (6), p.741-747
issn 1473-0197
1473-0189
language eng
recordid cdi_proquest_miscellaneous_733698197
source MEDLINE; Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Animals
Axons - physiology
Cell Communication - physiology
Cell Separation - instrumentation
Cells, Cultured
Coculture Techniques - instrumentation
Equipment Design
Equipment Failure Analysis
Microfluidic Analytical Techniques - instrumentation
Neuroglia - physiology
Rats
title Circular compartmentalized microfluidic platform: Study of axon-glia interactions
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T03%3A29%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Circular%20compartmentalized%20microfluidic%20platform:%20Study%20of%20axon-glia%20interactions&rft.jtitle=Lab%20on%20a%20chip&rft.au=Hosmane,%20Suneil&rft.date=2010-01-01&rft.volume=10&rft.issue=6&rft.spage=741&rft.epage=747&rft.pages=741-747&rft.issn=1473-0197&rft.eissn=1473-0189&rft_id=info:doi/10.1039/b918640a&rft_dat=%3Cproquest_cross%3E733698197%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733698197&rft_id=info:pmid/20221562&rfr_iscdi=true