Detection of Kinase Activity Using Versatile Fluorescence Quencher Probes
Turn off the light! A kinase assay system employs fluorescent peptides and a phosphate‐selective fluorescence quencher probe, and can be placed on a microfluidic chip (see picture). The system can be used for real‐time kinase monitoring, kinase inhibitor screening, and cancer diagnosis based on abno...
Gespeichert in:
Veröffentlicht in: | Angewandte Chemie (International ed.) 2010-07, Vol.49 (29), p.4919-4923 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4923 |
---|---|
container_issue | 29 |
container_start_page | 4919 |
container_title | Angewandte Chemie (International ed.) |
container_volume | 49 |
creator | Rhee, Hyun-Woo Lee, Seung Hwan Shin, Ik-Soo Choi, So Jung Park, Hun Hee Han, Kyungja Park, Tai Hyun Hong, Jong-In |
description | Turn off the light! A kinase assay system employs fluorescent peptides and a phosphate‐selective fluorescence quencher probe, and can be placed on a microfluidic chip (see picture). The system can be used for real‐time kinase monitoring, kinase inhibitor screening, and cancer diagnosis based on abnormal kinase activity observed in patients' samples. |
doi_str_mv | 10.1002/anie.201000879 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733630313</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733630313</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4729-3619361615b06d424f187a1619c8b455dd1fd2247d7323159881c006e7a039e43</originalsourceid><addsrcrecordid>eNqFkM1P3DAQxa0KBJRy5djmximL7bFj57jic9Vd2opuV-JieZMJdckm1E6A_e_rVeiKG4fRfOj3nkaPkGNGR4xSfmobhyNO40y1yj-QAyY5S0Ep2ImzAEiVlmyffAzhT-S1ptke2edUCsqAHpDJOXZYdK5tkrZKvrrGBkzG8fDkunUyD665T36hD7ZzNSaXdd96DAU2BSY_-th-o0---3aJ4RPZrWwd8Oi1H5L55cXPs-t0-u1qcjaepoVQPE8hY3msjMklzUrBRcW0snHPC70UUpYlq0rOhSoVcGAy15oVlGaoLIUcBRySk8H30bd_ewydWbn4UV3bBts-GAWQAQUGkRwNZOHbEDxW5tG7lfVrw6jZpGc26ZltelHw-dW6X66w3OL_44pAPgDPMY31O3ZmfDO5eGueDloXOnzZaq1_MJkCJc3i5sos1GyWw-LO3Eb-y8BXtjX23rtg5rd88wbTmVSCwT9gBZH0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733630313</pqid></control><display><type>article</type><title>Detection of Kinase Activity Using Versatile Fluorescence Quencher Probes</title><source>Wiley Online Library - AutoHoldings Journals</source><source>MEDLINE</source><creator>Rhee, Hyun-Woo ; Lee, Seung Hwan ; Shin, Ik-Soo ; Choi, So Jung ; Park, Hun Hee ; Han, Kyungja ; Park, Tai Hyun ; Hong, Jong-In</creator><creatorcontrib>Rhee, Hyun-Woo ; Lee, Seung Hwan ; Shin, Ik-Soo ; Choi, So Jung ; Park, Hun Hee ; Han, Kyungja ; Park, Tai Hyun ; Hong, Jong-In</creatorcontrib><description>Turn off the light! A kinase assay system employs fluorescent peptides and a phosphate‐selective fluorescence quencher probe, and can be placed on a microfluidic chip (see picture). The system can be used for real‐time kinase monitoring, kinase inhibitor screening, and cancer diagnosis based on abnormal kinase activity observed in patients' samples.</description><identifier>ISSN: 1433-7851</identifier><identifier>EISSN: 1521-3773</identifier><identifier>DOI: 10.1002/anie.201000879</identifier><identifier>PMID: 20540130</identifier><language>eng</language><publisher>Weinheim: Wiley-VCH Verlag</publisher><subject>Calcium-Calmodulin-Dependent Protein Kinase Type 2 - metabolism ; cancer ; Casein Kinase II - metabolism ; Cyclic AMP-Dependent Protein Kinases - metabolism ; fluorescence ; Fluorescent Dyes - chemistry ; fluorescent probes ; Heterocyclic Compounds, 3-Ring - chemistry ; Humans ; kinases ; Microfluidic Analytical Techniques - methods ; Neoplasms - diagnosis ; Neoplasms - enzymology ; Phosphorylation ; Protein Kinase Inhibitors - chemistry ; Protein Kinase Inhibitors - pharmacology ; Protein Kinases - chemistry ; Protein Kinases - metabolism ; Proto-Oncogene Proteins c-abl - metabolism</subject><ispartof>Angewandte Chemie (International ed.), 2010-07, Vol.49 (29), p.4919-4923</ispartof><rights>Copyright © 2010 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4729-3619361615b06d424f187a1619c8b455dd1fd2247d7323159881c006e7a039e43</citedby><cites>FETCH-LOGICAL-c4729-3619361615b06d424f187a1619c8b455dd1fd2247d7323159881c006e7a039e43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fanie.201000879$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fanie.201000879$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20540130$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rhee, Hyun-Woo</creatorcontrib><creatorcontrib>Lee, Seung Hwan</creatorcontrib><creatorcontrib>Shin, Ik-Soo</creatorcontrib><creatorcontrib>Choi, So Jung</creatorcontrib><creatorcontrib>Park, Hun Hee</creatorcontrib><creatorcontrib>Han, Kyungja</creatorcontrib><creatorcontrib>Park, Tai Hyun</creatorcontrib><creatorcontrib>Hong, Jong-In</creatorcontrib><title>Detection of Kinase Activity Using Versatile Fluorescence Quencher Probes</title><title>Angewandte Chemie (International ed.)</title><addtitle>Angewandte Chemie International Edition</addtitle><description>Turn off the light! A kinase assay system employs fluorescent peptides and a phosphate‐selective fluorescence quencher probe, and can be placed on a microfluidic chip (see picture). The system can be used for real‐time kinase monitoring, kinase inhibitor screening, and cancer diagnosis based on abnormal kinase activity observed in patients' samples.</description><subject>Calcium-Calmodulin-Dependent Protein Kinase Type 2 - metabolism</subject><subject>cancer</subject><subject>Casein Kinase II - metabolism</subject><subject>Cyclic AMP-Dependent Protein Kinases - metabolism</subject><subject>fluorescence</subject><subject>Fluorescent Dyes - chemistry</subject><subject>fluorescent probes</subject><subject>Heterocyclic Compounds, 3-Ring - chemistry</subject><subject>Humans</subject><subject>kinases</subject><subject>Microfluidic Analytical Techniques - methods</subject><subject>Neoplasms - diagnosis</subject><subject>Neoplasms - enzymology</subject><subject>Phosphorylation</subject><subject>Protein Kinase Inhibitors - chemistry</subject><subject>Protein Kinase Inhibitors - pharmacology</subject><subject>Protein Kinases - chemistry</subject><subject>Protein Kinases - metabolism</subject><subject>Proto-Oncogene Proteins c-abl - metabolism</subject><issn>1433-7851</issn><issn>1521-3773</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkM1P3DAQxa0KBJRy5djmximL7bFj57jic9Vd2opuV-JieZMJdckm1E6A_e_rVeiKG4fRfOj3nkaPkGNGR4xSfmobhyNO40y1yj-QAyY5S0Ep2ImzAEiVlmyffAzhT-S1ptke2edUCsqAHpDJOXZYdK5tkrZKvrrGBkzG8fDkunUyD665T36hD7ZzNSaXdd96DAU2BSY_-th-o0---3aJ4RPZrWwd8Oi1H5L55cXPs-t0-u1qcjaepoVQPE8hY3msjMklzUrBRcW0snHPC70UUpYlq0rOhSoVcGAy15oVlGaoLIUcBRySk8H30bd_ewydWbn4UV3bBts-GAWQAQUGkRwNZOHbEDxW5tG7lfVrw6jZpGc26ZltelHw-dW6X66w3OL_44pAPgDPMY31O3ZmfDO5eGueDloXOnzZaq1_MJkCJc3i5sos1GyWw-LO3Eb-y8BXtjX23rtg5rd88wbTmVSCwT9gBZH0</recordid><startdate>20100705</startdate><enddate>20100705</enddate><creator>Rhee, Hyun-Woo</creator><creator>Lee, Seung Hwan</creator><creator>Shin, Ik-Soo</creator><creator>Choi, So Jung</creator><creator>Park, Hun Hee</creator><creator>Han, Kyungja</creator><creator>Park, Tai Hyun</creator><creator>Hong, Jong-In</creator><general>Wiley-VCH Verlag</general><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>FBQ</scope><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20100705</creationdate><title>Detection of Kinase Activity Using Versatile Fluorescence Quencher Probes</title><author>Rhee, Hyun-Woo ; Lee, Seung Hwan ; Shin, Ik-Soo ; Choi, So Jung ; Park, Hun Hee ; Han, Kyungja ; Park, Tai Hyun ; Hong, Jong-In</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4729-3619361615b06d424f187a1619c8b455dd1fd2247d7323159881c006e7a039e43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Calcium-Calmodulin-Dependent Protein Kinase Type 2 - metabolism</topic><topic>cancer</topic><topic>Casein Kinase II - metabolism</topic><topic>Cyclic AMP-Dependent Protein Kinases - metabolism</topic><topic>fluorescence</topic><topic>Fluorescent Dyes - chemistry</topic><topic>fluorescent probes</topic><topic>Heterocyclic Compounds, 3-Ring - chemistry</topic><topic>Humans</topic><topic>kinases</topic><topic>Microfluidic Analytical Techniques - methods</topic><topic>Neoplasms - diagnosis</topic><topic>Neoplasms - enzymology</topic><topic>Phosphorylation</topic><topic>Protein Kinase Inhibitors - chemistry</topic><topic>Protein Kinase Inhibitors - pharmacology</topic><topic>Protein Kinases - chemistry</topic><topic>Protein Kinases - metabolism</topic><topic>Proto-Oncogene Proteins c-abl - metabolism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rhee, Hyun-Woo</creatorcontrib><creatorcontrib>Lee, Seung Hwan</creatorcontrib><creatorcontrib>Shin, Ik-Soo</creatorcontrib><creatorcontrib>Choi, So Jung</creatorcontrib><creatorcontrib>Park, Hun Hee</creatorcontrib><creatorcontrib>Han, Kyungja</creatorcontrib><creatorcontrib>Park, Tai Hyun</creatorcontrib><creatorcontrib>Hong, Jong-In</creatorcontrib><collection>AGRIS</collection><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Angewandte Chemie (International ed.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rhee, Hyun-Woo</au><au>Lee, Seung Hwan</au><au>Shin, Ik-Soo</au><au>Choi, So Jung</au><au>Park, Hun Hee</au><au>Han, Kyungja</au><au>Park, Tai Hyun</au><au>Hong, Jong-In</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Detection of Kinase Activity Using Versatile Fluorescence Quencher Probes</atitle><jtitle>Angewandte Chemie (International ed.)</jtitle><addtitle>Angewandte Chemie International Edition</addtitle><date>2010-07-05</date><risdate>2010</risdate><volume>49</volume><issue>29</issue><spage>4919</spage><epage>4923</epage><pages>4919-4923</pages><issn>1433-7851</issn><eissn>1521-3773</eissn><abstract>Turn off the light! A kinase assay system employs fluorescent peptides and a phosphate‐selective fluorescence quencher probe, and can be placed on a microfluidic chip (see picture). The system can be used for real‐time kinase monitoring, kinase inhibitor screening, and cancer diagnosis based on abnormal kinase activity observed in patients' samples.</abstract><cop>Weinheim</cop><pub>Wiley-VCH Verlag</pub><pmid>20540130</pmid><doi>10.1002/anie.201000879</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1433-7851 |
ispartof | Angewandte Chemie (International ed.), 2010-07, Vol.49 (29), p.4919-4923 |
issn | 1433-7851 1521-3773 |
language | eng |
recordid | cdi_proquest_miscellaneous_733630313 |
source | Wiley Online Library - AutoHoldings Journals; MEDLINE |
subjects | Calcium-Calmodulin-Dependent Protein Kinase Type 2 - metabolism cancer Casein Kinase II - metabolism Cyclic AMP-Dependent Protein Kinases - metabolism fluorescence Fluorescent Dyes - chemistry fluorescent probes Heterocyclic Compounds, 3-Ring - chemistry Humans kinases Microfluidic Analytical Techniques - methods Neoplasms - diagnosis Neoplasms - enzymology Phosphorylation Protein Kinase Inhibitors - chemistry Protein Kinase Inhibitors - pharmacology Protein Kinases - chemistry Protein Kinases - metabolism Proto-Oncogene Proteins c-abl - metabolism |
title | Detection of Kinase Activity Using Versatile Fluorescence Quencher Probes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T09%3A09%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Detection%20of%20Kinase%20Activity%20Using%20Versatile%20Fluorescence%20Quencher%20Probes&rft.jtitle=Angewandte%20Chemie%20(International%20ed.)&rft.au=Rhee,%20Hyun-Woo&rft.date=2010-07-05&rft.volume=49&rft.issue=29&rft.spage=4919&rft.epage=4923&rft.pages=4919-4923&rft.issn=1433-7851&rft.eissn=1521-3773&rft_id=info:doi/10.1002/anie.201000879&rft_dat=%3Cproquest_cross%3E733630313%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733630313&rft_id=info:pmid/20540130&rfr_iscdi=true |