MRI After Technically Successful Renal Cryoablation: Early Contrast Enhancement as a Common Finding

The purpose of this study was to assess the MRI appearance and enhancement of renal masses within 36 hours after cryoablation. From March 2003 through January 2008, 129 patients underwent imaging-guided cryoablation for renal masses. Twenty-three of these patients underwent MRI within 36 hours after...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2010-03, Vol.194 (3), p.790-793
Hauptverfasser: Porter, Christopher A., IV, Woodrum, David A, Callstrom, Matthew R, Schmit, Grant D, Misra, Sanjay, Charboneau, J. William, Atwell, Thomas D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 793
container_issue 3
container_start_page 790
container_title American journal of roentgenology (1976)
container_volume 194
creator Porter, Christopher A., IV
Woodrum, David A
Callstrom, Matthew R
Schmit, Grant D
Misra, Sanjay
Charboneau, J. William
Atwell, Thomas D
description The purpose of this study was to assess the MRI appearance and enhancement of renal masses within 36 hours after cryoablation. From March 2003 through January 2008, 129 patients underwent imaging-guided cryoablation for renal masses. Twenty-three of these patients underwent MRI within 36 hours after ablation. During MRI, acquisition of axial T1- and T2-weighted images was followed by administration of a gadolinium contrast agent. Standard follow-up included MRI 3-6 months after ablation. Eight of the 23 renal masses imaged within 6-36 hours after ablation were enhanced on MR images. Five of the eight lesions exhibited homogeneous enhancement, and the other three had heterogeneous or rim enhancement. Seven of the eight lesions exhibited no enhancement at the 6-month follow-up examination. One patient underwent follow-up imaging 10 months rather than 3-6 months after the procedure, but no enhancement was seen. T2-weighted signal intensity was mixed among the 23 renal masses. T1-weighted signal intensity was mixed among the 23 renal masses and the eight lesions that became enhanced, but there was a trend for higher T1 signal intensity at the 3- to 6-month follow-up examination. The high proportion of enhancing lesions 3 months after treatment and the resolution of enhancement 6 months afterward suggest that it may be reasonable to wait 6 months after technically successful renal cryoablation before performing contrast-enhanced MRI.
doi_str_mv 10.2214/AJR.09.2518
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733585229</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733585229</sourcerecordid><originalsourceid>FETCH-LOGICAL-c415t-857c8c1d4d2f28c22a6ea0098b61b3c3100076a73a62ce1c7803d0ea8952116b3</originalsourceid><addsrcrecordid>eNpF0M9r2zAYxnFRNta022n3ocvaQ3GmV7JlubcQ0h-jY5B10Jt4LcuNhi23kk3If1-FZNtJB314kL6EfAY25xzyb4vv6zmr5rwAdUJmUOQyE5DDOzJjQkKmmHg6JWcx_mGMlaoqP5BTzqAUIGFGzI_1PV20ow300ZqNdwa7bkd_TcbYGNupo2vrsaPLsBuw7nB0g7-mKwwJLQc_BowjXfkNemN760eKkWK66fvB0xvnG-efP5L3LXbRfjqe5-T3zepxeZc9_Ly9Xy4eMpNDMWaqKI0y0OQNb7kynKO0yFilagm1MAL275dYCpTcWDBl-lnDLKqq4ACyFufk8rD7EobXycZR9y4a23Xo7TBFXQpRqILzKsmrgzRhiDHYVr8E12PYaWB6H1WnqJpVeh816S_H3anubfPP_q2YwNcjwJj6tSHVcPG_4zkHKVhyFwe3cc-brQtWxz7lTrOgt9stVLkWuqyYeAPFrIrY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733585229</pqid></control><display><type>article</type><title>MRI After Technically Successful Renal Cryoablation: Early Contrast Enhancement as a Common Finding</title><source>American Roentgen Ray Society</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Porter, Christopher A., IV ; Woodrum, David A ; Callstrom, Matthew R ; Schmit, Grant D ; Misra, Sanjay ; Charboneau, J. William ; Atwell, Thomas D</creator><creatorcontrib>Porter, Christopher A., IV ; Woodrum, David A ; Callstrom, Matthew R ; Schmit, Grant D ; Misra, Sanjay ; Charboneau, J. William ; Atwell, Thomas D</creatorcontrib><description>The purpose of this study was to assess the MRI appearance and enhancement of renal masses within 36 hours after cryoablation. From March 2003 through January 2008, 129 patients underwent imaging-guided cryoablation for renal masses. Twenty-three of these patients underwent MRI within 36 hours after ablation. During MRI, acquisition of axial T1- and T2-weighted images was followed by administration of a gadolinium contrast agent. Standard follow-up included MRI 3-6 months after ablation. Eight of the 23 renal masses imaged within 6-36 hours after ablation were enhanced on MR images. Five of the eight lesions exhibited homogeneous enhancement, and the other three had heterogeneous or rim enhancement. Seven of the eight lesions exhibited no enhancement at the 6-month follow-up examination. One patient underwent follow-up imaging 10 months rather than 3-6 months after the procedure, but no enhancement was seen. T2-weighted signal intensity was mixed among the 23 renal masses. T1-weighted signal intensity was mixed among the 23 renal masses and the eight lesions that became enhanced, but there was a trend for higher T1 signal intensity at the 3- to 6-month follow-up examination. The high proportion of enhancing lesions 3 months after treatment and the resolution of enhancement 6 months afterward suggest that it may be reasonable to wait 6 months after technically successful renal cryoablation before performing contrast-enhanced MRI.</description><identifier>ISSN: 0361-803X</identifier><identifier>EISSN: 1546-3141</identifier><identifier>DOI: 10.2214/AJR.09.2518</identifier><identifier>PMID: 20173161</identifier><identifier>CODEN: AAJRDX</identifier><language>eng</language><publisher>Reston, VA: Am Roentgen Ray Soc</publisher><subject>Aged ; Biological and medical sciences ; Contrast Media ; Cryosurgery - methods ; Female ; Gadolinium DTPA ; Humans ; Image Processing, Computer-Assisted ; Investigative techniques, diagnostic techniques (general aspects) ; Kidney Neoplasms - pathology ; Kidney Neoplasms - surgery ; Magnetic Resonance Imaging - methods ; Male ; Medical sciences ; Middle Aged ; Radiography, Interventional ; Retrospective Studies ; Ultrasonography, Interventional</subject><ispartof>American journal of roentgenology (1976), 2010-03, Vol.194 (3), p.790-793</ispartof><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c415t-857c8c1d4d2f28c22a6ea0098b61b3c3100076a73a62ce1c7803d0ea8952116b3</citedby><cites>FETCH-LOGICAL-c415t-857c8c1d4d2f28c22a6ea0098b61b3c3100076a73a62ce1c7803d0ea8952116b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4120,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=22421630$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20173161$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Porter, Christopher A., IV</creatorcontrib><creatorcontrib>Woodrum, David A</creatorcontrib><creatorcontrib>Callstrom, Matthew R</creatorcontrib><creatorcontrib>Schmit, Grant D</creatorcontrib><creatorcontrib>Misra, Sanjay</creatorcontrib><creatorcontrib>Charboneau, J. William</creatorcontrib><creatorcontrib>Atwell, Thomas D</creatorcontrib><title>MRI After Technically Successful Renal Cryoablation: Early Contrast Enhancement as a Common Finding</title><title>American journal of roentgenology (1976)</title><addtitle>AJR Am J Roentgenol</addtitle><description>The purpose of this study was to assess the MRI appearance and enhancement of renal masses within 36 hours after cryoablation. From March 2003 through January 2008, 129 patients underwent imaging-guided cryoablation for renal masses. Twenty-three of these patients underwent MRI within 36 hours after ablation. During MRI, acquisition of axial T1- and T2-weighted images was followed by administration of a gadolinium contrast agent. Standard follow-up included MRI 3-6 months after ablation. Eight of the 23 renal masses imaged within 6-36 hours after ablation were enhanced on MR images. Five of the eight lesions exhibited homogeneous enhancement, and the other three had heterogeneous or rim enhancement. Seven of the eight lesions exhibited no enhancement at the 6-month follow-up examination. One patient underwent follow-up imaging 10 months rather than 3-6 months after the procedure, but no enhancement was seen. T2-weighted signal intensity was mixed among the 23 renal masses. T1-weighted signal intensity was mixed among the 23 renal masses and the eight lesions that became enhanced, but there was a trend for higher T1 signal intensity at the 3- to 6-month follow-up examination. The high proportion of enhancing lesions 3 months after treatment and the resolution of enhancement 6 months afterward suggest that it may be reasonable to wait 6 months after technically successful renal cryoablation before performing contrast-enhanced MRI.</description><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Contrast Media</subject><subject>Cryosurgery - methods</subject><subject>Female</subject><subject>Gadolinium DTPA</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Kidney Neoplasms - pathology</subject><subject>Kidney Neoplasms - surgery</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Radiography, Interventional</subject><subject>Retrospective Studies</subject><subject>Ultrasonography, Interventional</subject><issn>0361-803X</issn><issn>1546-3141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpF0M9r2zAYxnFRNta022n3ocvaQ3GmV7JlubcQ0h-jY5B10Jt4LcuNhi23kk3If1-FZNtJB314kL6EfAY25xzyb4vv6zmr5rwAdUJmUOQyE5DDOzJjQkKmmHg6JWcx_mGMlaoqP5BTzqAUIGFGzI_1PV20ow300ZqNdwa7bkd_TcbYGNupo2vrsaPLsBuw7nB0g7-mKwwJLQc_BowjXfkNemN760eKkWK66fvB0xvnG-efP5L3LXbRfjqe5-T3zepxeZc9_Ly9Xy4eMpNDMWaqKI0y0OQNb7kynKO0yFilagm1MAL275dYCpTcWDBl-lnDLKqq4ACyFufk8rD7EobXycZR9y4a23Xo7TBFXQpRqILzKsmrgzRhiDHYVr8E12PYaWB6H1WnqJpVeh816S_H3anubfPP_q2YwNcjwJj6tSHVcPG_4zkHKVhyFwe3cc-brQtWxz7lTrOgt9stVLkWuqyYeAPFrIrY</recordid><startdate>20100301</startdate><enddate>20100301</enddate><creator>Porter, Christopher A., IV</creator><creator>Woodrum, David A</creator><creator>Callstrom, Matthew R</creator><creator>Schmit, Grant D</creator><creator>Misra, Sanjay</creator><creator>Charboneau, J. William</creator><creator>Atwell, Thomas D</creator><general>Am Roentgen Ray Soc</general><general>American Roentgen Ray Society</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20100301</creationdate><title>MRI After Technically Successful Renal Cryoablation: Early Contrast Enhancement as a Common Finding</title><author>Porter, Christopher A., IV ; Woodrum, David A ; Callstrom, Matthew R ; Schmit, Grant D ; Misra, Sanjay ; Charboneau, J. William ; Atwell, Thomas D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c415t-857c8c1d4d2f28c22a6ea0098b61b3c3100076a73a62ce1c7803d0ea8952116b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Contrast Media</topic><topic>Cryosurgery - methods</topic><topic>Female</topic><topic>Gadolinium DTPA</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Kidney Neoplasms - pathology</topic><topic>Kidney Neoplasms - surgery</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Radiography, Interventional</topic><topic>Retrospective Studies</topic><topic>Ultrasonography, Interventional</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Porter, Christopher A., IV</creatorcontrib><creatorcontrib>Woodrum, David A</creatorcontrib><creatorcontrib>Callstrom, Matthew R</creatorcontrib><creatorcontrib>Schmit, Grant D</creatorcontrib><creatorcontrib>Misra, Sanjay</creatorcontrib><creatorcontrib>Charboneau, J. William</creatorcontrib><creatorcontrib>Atwell, Thomas D</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of roentgenology (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Porter, Christopher A., IV</au><au>Woodrum, David A</au><au>Callstrom, Matthew R</au><au>Schmit, Grant D</au><au>Misra, Sanjay</au><au>Charboneau, J. William</au><au>Atwell, Thomas D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>MRI After Technically Successful Renal Cryoablation: Early Contrast Enhancement as a Common Finding</atitle><jtitle>American journal of roentgenology (1976)</jtitle><addtitle>AJR Am J Roentgenol</addtitle><date>2010-03-01</date><risdate>2010</risdate><volume>194</volume><issue>3</issue><spage>790</spage><epage>793</epage><pages>790-793</pages><issn>0361-803X</issn><eissn>1546-3141</eissn><coden>AAJRDX</coden><abstract>The purpose of this study was to assess the MRI appearance and enhancement of renal masses within 36 hours after cryoablation. From March 2003 through January 2008, 129 patients underwent imaging-guided cryoablation for renal masses. Twenty-three of these patients underwent MRI within 36 hours after ablation. During MRI, acquisition of axial T1- and T2-weighted images was followed by administration of a gadolinium contrast agent. Standard follow-up included MRI 3-6 months after ablation. Eight of the 23 renal masses imaged within 6-36 hours after ablation were enhanced on MR images. Five of the eight lesions exhibited homogeneous enhancement, and the other three had heterogeneous or rim enhancement. Seven of the eight lesions exhibited no enhancement at the 6-month follow-up examination. One patient underwent follow-up imaging 10 months rather than 3-6 months after the procedure, but no enhancement was seen. T2-weighted signal intensity was mixed among the 23 renal masses. T1-weighted signal intensity was mixed among the 23 renal masses and the eight lesions that became enhanced, but there was a trend for higher T1 signal intensity at the 3- to 6-month follow-up examination. The high proportion of enhancing lesions 3 months after treatment and the resolution of enhancement 6 months afterward suggest that it may be reasonable to wait 6 months after technically successful renal cryoablation before performing contrast-enhanced MRI.</abstract><cop>Reston, VA</cop><pub>Am Roentgen Ray Soc</pub><pmid>20173161</pmid><doi>10.2214/AJR.09.2518</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0361-803X
ispartof American journal of roentgenology (1976), 2010-03, Vol.194 (3), p.790-793
issn 0361-803X
1546-3141
language eng
recordid cdi_proquest_miscellaneous_733585229
source American Roentgen Ray Society; MEDLINE; Alma/SFX Local Collection
subjects Aged
Biological and medical sciences
Contrast Media
Cryosurgery - methods
Female
Gadolinium DTPA
Humans
Image Processing, Computer-Assisted
Investigative techniques, diagnostic techniques (general aspects)
Kidney Neoplasms - pathology
Kidney Neoplasms - surgery
Magnetic Resonance Imaging - methods
Male
Medical sciences
Middle Aged
Radiography, Interventional
Retrospective Studies
Ultrasonography, Interventional
title MRI After Technically Successful Renal Cryoablation: Early Contrast Enhancement as a Common Finding
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T07%3A01%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=MRI%20After%20Technically%20Successful%20Renal%20Cryoablation:%20Early%20Contrast%20Enhancement%20as%20a%20Common%20Finding&rft.jtitle=American%20journal%20of%20roentgenology%20(1976)&rft.au=Porter,%20Christopher%20A.,%20IV&rft.date=2010-03-01&rft.volume=194&rft.issue=3&rft.spage=790&rft.epage=793&rft.pages=790-793&rft.issn=0361-803X&rft.eissn=1546-3141&rft.coden=AAJRDX&rft_id=info:doi/10.2214/AJR.09.2518&rft_dat=%3Cproquest_cross%3E733585229%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733585229&rft_id=info:pmid/20173161&rfr_iscdi=true