New techniques to extract impacted partially covered metallic biliary stents

One of the problems affecting metallic biliary stents is the difficulty of removing them, especially after a period of months or if they have migrated. Several approaches have been used to remove both covered and uncovered stents, although with different degrees of effectiveness. We report two new a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastroenterología y hepatología 2009-08, Vol.32 (7), p.489-494
Hauptverfasser: Pérez Roldán, Francisco, González Carro, Pedro Santiago, Legaz Huidobro, María Luisa, Roncero García-Escribano, Oscar, Sánchez-Manjavacas Muñoz, Natividad, Ynfante Ferrús, Marina, Ruíz Carrillo, Francisco, Villafáñez García, María Concepción
Format: Artikel
Sprache:spa
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:One of the problems affecting metallic biliary stents is the difficulty of removing them, especially after a period of months or if they have migrated. Several approaches have been used to remove both covered and uncovered stents, although with different degrees of effectiveness. We report two new approaches to removing partially covered stents that migrated proximally and that impacted in the papillary area and distal common bile duct. One stent was removed by papillectomy and the other by using duodenoscopy-guided controlled radial expansion balloon dilation. In both cases, the stents were removed without severe complications for the patient, leaving a good caliber in the stenosis.
ISSN:0210-5705
DOI:10.1016/j.gastrohep.2009.03.010