Sterile Mediastinal Gas Mimicking Abscess in Aortic Aneurysm Repair
Six weeks after aortic aneurysm repair, computed tomography (CT) showed mediastinal gas where absorbable gelatin sponge (Gelfoam) was used. A leukocyte scan labeled with indium 111, however, was normal and surgical exploration showed no infection. Sterile gas collections may be seen following absorb...
Gespeichert in:
Veröffentlicht in: | Chest 1992-12, Vol.102 (6), p.1911-1913 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Six weeks after aortic aneurysm repair, computed tomography (CT) showed mediastinal gas where absorbable gelatin sponge (Gelfoam) was used. A leukocyte scan labeled with indium 111, however, was normal and surgical exploration showed no infection. Sterile gas collections may be seen following absorbable gelatin sponge use many weeks after surgery and 111In-labeled leukocyte scanning may be a useful differential test. |
---|---|