White light reconstruction setup for shearograms
A reconstruction setup for the shearographic camera is discussed that is simpler than a Fourier processor and gives bright reconstructions with white light.
Gespeichert in:
Veröffentlicht in: | Applied Optics 1989-08, Vol.28 (16), p.3270-3271 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 3271 |
---|---|
container_issue | 16 |
container_start_page | 3270 |
container_title | Applied Optics |
container_volume | 28 |
creator | KLUMPP, P. A SCHNACK, E |
description | A reconstruction setup for the shearographic camera is discussed that is simpler than a Fourier processor and gives bright reconstructions with white light. |
doi_str_mv | 10.1364/AO.28.003270 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733351993</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733351993</sourcerecordid><originalsourceid>FETCH-LOGICAL-c319t-72f210fa4b26621b241c74acf9d851f7a6d8fdc64e31673420607bc07ee41a0b3</originalsourceid><addsrcrecordid>eNo90EtLAzEUBeAgiq3VnWuZheDGqTfvybIUX1DoRnEZMpmkHZlHTTIL_31HWru6cPk4HA5CtxjmmAr2tFjPSTEHoETCGZpiTlXOOCHnaArjNxeK8gm6ivEbAJNCqEs0IcA5FwVMEXxt6-Sypt5sUxac7buYwmBT3XdZdGnYZb4PWdw6E_pNMG28RhfeNNHdHO8Mfb48fyzf8tX69X25WOWWYpVySTzB4A0riRAEl4RhK5mxXlUFx14aURW-soI5ioWkjIAAWVqQzjFsoKQz9HDI3YX-Z3Ax6baO1jWN6Vw_RC0ppRwrRUf5eJA29DEG5_Uu1K0JvxqD_ptIL9aaFPow0cjvjsFD2brqhP83GcH9EZhoTeOD6WwdT04ITNVYeQ_17Wyc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733351993</pqid></control><display><type>article</type><title>White light reconstruction setup for shearograms</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>KLUMPP, P. A ; SCHNACK, E</creator><creatorcontrib>KLUMPP, P. A ; SCHNACK, E</creatorcontrib><description>A reconstruction setup for the shearographic camera is discussed that is simpler than a Fourier processor and gives bright reconstructions with white light.</description><identifier>ISSN: 0003-6935</identifier><identifier>ISSN: 1559-128X</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.28.003270</identifier><identifier>PMID: 20555680</identifier><identifier>CODEN: APOPAI</identifier><language>eng</language><publisher>Washington, DC: Optical Society of America</publisher><subject>Exact sciences and technology ; Instruments, apparatus, components and techniques common to several branches of physics and astronomy ; Interferometers ; Optical instruments, equipment and techniques ; Physics</subject><ispartof>Applied Optics, 1989-08, Vol.28 (16), p.3270-3271</ispartof><rights>1990 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c319t-72f210fa4b26621b241c74acf9d851f7a6d8fdc64e31673420607bc07ee41a0b3</citedby><cites>FETCH-LOGICAL-c319t-72f210fa4b26621b241c74acf9d851f7a6d8fdc64e31673420607bc07ee41a0b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=6613967$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20555680$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KLUMPP, P. A</creatorcontrib><creatorcontrib>SCHNACK, E</creatorcontrib><title>White light reconstruction setup for shearograms</title><title>Applied Optics</title><addtitle>Appl Opt</addtitle><description>A reconstruction setup for the shearographic camera is discussed that is simpler than a Fourier processor and gives bright reconstructions with white light.</description><subject>Exact sciences and technology</subject><subject>Instruments, apparatus, components and techniques common to several branches of physics and astronomy</subject><subject>Interferometers</subject><subject>Optical instruments, equipment and techniques</subject><subject>Physics</subject><issn>0003-6935</issn><issn>1559-128X</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><recordid>eNo90EtLAzEUBeAgiq3VnWuZheDGqTfvybIUX1DoRnEZMpmkHZlHTTIL_31HWru6cPk4HA5CtxjmmAr2tFjPSTEHoETCGZpiTlXOOCHnaArjNxeK8gm6ivEbAJNCqEs0IcA5FwVMEXxt6-Sypt5sUxac7buYwmBT3XdZdGnYZb4PWdw6E_pNMG28RhfeNNHdHO8Mfb48fyzf8tX69X25WOWWYpVySTzB4A0riRAEl4RhK5mxXlUFx14aURW-soI5ioWkjIAAWVqQzjFsoKQz9HDI3YX-Z3Ax6baO1jWN6Vw_RC0ppRwrRUf5eJA29DEG5_Uu1K0JvxqD_ptIL9aaFPow0cjvjsFD2brqhP83GcH9EZhoTeOD6WwdT04ITNVYeQ_17Wyc</recordid><startdate>19890815</startdate><enddate>19890815</enddate><creator>KLUMPP, P. A</creator><creator>SCHNACK, E</creator><general>Optical Society of America</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19890815</creationdate><title>White light reconstruction setup for shearograms</title><author>KLUMPP, P. A ; SCHNACK, E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c319t-72f210fa4b26621b241c74acf9d851f7a6d8fdc64e31673420607bc07ee41a0b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Exact sciences and technology</topic><topic>Instruments, apparatus, components and techniques common to several branches of physics and astronomy</topic><topic>Interferometers</topic><topic>Optical instruments, equipment and techniques</topic><topic>Physics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KLUMPP, P. A</creatorcontrib><creatorcontrib>SCHNACK, E</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied Optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KLUMPP, P. A</au><au>SCHNACK, E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>White light reconstruction setup for shearograms</atitle><jtitle>Applied Optics</jtitle><addtitle>Appl Opt</addtitle><date>1989-08-15</date><risdate>1989</risdate><volume>28</volume><issue>16</issue><spage>3270</spage><epage>3271</epage><pages>3270-3271</pages><issn>0003-6935</issn><issn>1559-128X</issn><eissn>1539-4522</eissn><coden>APOPAI</coden><abstract>A reconstruction setup for the shearographic camera is discussed that is simpler than a Fourier processor and gives bright reconstructions with white light.</abstract><cop>Washington, DC</cop><pub>Optical Society of America</pub><pmid>20555680</pmid><doi>10.1364/AO.28.003270</doi><tpages>2</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-6935 |
ispartof | Applied Optics, 1989-08, Vol.28 (16), p.3270-3271 |
issn | 0003-6935 1559-128X 1539-4522 |
language | eng |
recordid | cdi_proquest_miscellaneous_733351993 |
source | Alma/SFX Local Collection; Optica Publishing Group Journals |
subjects | Exact sciences and technology Instruments, apparatus, components and techniques common to several branches of physics and astronomy Interferometers Optical instruments, equipment and techniques Physics |
title | White light reconstruction setup for shearograms |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T02%3A29%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=White%20light%20reconstruction%20setup%20for%20shearograms&rft.jtitle=Applied%20Optics&rft.au=KLUMPP,%20P.%20A&rft.date=1989-08-15&rft.volume=28&rft.issue=16&rft.spage=3270&rft.epage=3271&rft.pages=3270-3271&rft.issn=0003-6935&rft.eissn=1539-4522&rft.coden=APOPAI&rft_id=info:doi/10.1364/AO.28.003270&rft_dat=%3Cproquest_cross%3E733351993%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733351993&rft_id=info:pmid/20555680&rfr_iscdi=true |