Crossed four-bar mechanism for improved prosthetic grasp
Passive linkages were developed to improve grasp functionality and minimize a prosthetic terminal device's number of user-controlled inputs. The linkages act to stabilize grasped objects and substitute for the palp of normal anatomical fingers. The Southampton Hand Assessment Procedure was used...
Gespeichert in:
Veröffentlicht in: | Journal of rehabilitation research and development 2009-01, Vol.46 (8), p.1011-1020 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1020 |
---|---|
container_issue | 8 |
container_start_page | 1011 |
container_title | Journal of rehabilitation research and development |
container_volume | 46 |
creator | Ramirez, Issa A Lusk, Craig P Dubey, Rajiv Highsmith, M Jason Maitland, Murray E |
description | Passive linkages were developed to improve grasp functionality and minimize a prosthetic terminal device's number of user-controlled inputs. The linkages act to stabilize grasped objects and substitute for the palp of normal anatomical fingers. The Southampton Hand Assessment Procedure was used to compare the normal anatomical hand, this prototype, and a commercially available (Hosmer) hook. In testing, prosthetic terminal devices took three times as long as the normal anatomical hand to perform tasks. Nevertheless, heavyweight power and spherical grasps were improved with the use of the new mechanism compared with the commercial hook. Conversely, precision grasps were worsened because of the lack of a high-friction surface on the distal end of the prototype. |
doi_str_mv | 10.1682/jrrd.2009.01.0004 |
format | Article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_733347761</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A227198716</galeid><sourcerecordid>A227198716</sourcerecordid><originalsourceid>FETCH-LOGICAL-c506t-2150164370459627f625c3b268ace22ec991db4ad76e3667511684f3e211a3c73</originalsourceid><addsrcrecordid>eNp9kctOwzAQRS0EouXxAWxQxQJWCZ5x_MiyKm9VQqpgbbmO06ZqkmKnSPw9jlpYsEBejDQ-1zPXl5ALoCkIhbcr74sUKc1TCimlNDsgQ8iZSoBxPCRDKjOVSAkwICchrCKBDOGYDJACl4qrIVET34bgilHZbn0yN35UO7s0TRXq2PKjqt749jPexxK6pesqO1p4EzZn5Kg06-DO9_WUvD_cv02ekunr4_NkPE0sp6JLEDgFkTFJM54LlKVAbtkchTLWITqb51DMM1NI4ZgQkkN0lpXMIYBhVrJTcrN7Ny7wsXWh03UVrFuvTePabdCSMZZJKSCS1_-SCAyoyvIIXv0BV9F8E11EhqNiAP3cdActzNrpqinbzhsbT-HqyraNK6vYHyNKyJUEEQWwE9j-R70r9cZXtfFfGqju49Ivs9md7uPSFHQfV9Rc7jfZzmtX_Cp-8mHfbrGNWw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>215283117</pqid></control><display><type>article</type><title>Crossed four-bar mechanism for improved prosthetic grasp</title><source>U.S. Government Documents</source><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Ramirez, Issa A ; Lusk, Craig P ; Dubey, Rajiv ; Highsmith, M Jason ; Maitland, Murray E</creator><creatorcontrib>Ramirez, Issa A ; Lusk, Craig P ; Dubey, Rajiv ; Highsmith, M Jason ; Maitland, Murray E</creatorcontrib><description>Passive linkages were developed to improve grasp functionality and minimize a prosthetic terminal device's number of user-controlled inputs. The linkages act to stabilize grasped objects and substitute for the palp of normal anatomical fingers. The Southampton Hand Assessment Procedure was used to compare the normal anatomical hand, this prototype, and a commercially available (Hosmer) hook. In testing, prosthetic terminal devices took three times as long as the normal anatomical hand to perform tasks. Nevertheless, heavyweight power and spherical grasps were improved with the use of the new mechanism compared with the commercial hook. Conversely, precision grasps were worsened because of the lack of a high-friction surface on the distal end of the prototype.</description><identifier>ISSN: 0748-7711</identifier><identifier>EISSN: 1938-1352</identifier><identifier>DOI: 10.1682/jrrd.2009.01.0004</identifier><identifier>PMID: 20157858</identifier><identifier>CODEN: JRRDDB</identifier><language>eng</language><publisher>United States: Department of Veterans Affairs</publisher><subject>Activities of Daily Living ; Artificial arms ; Artificial Limbs ; Colleges & universities ; Design and construction ; Hand ; Hands ; Health aspects ; Humans ; Motor Skills ; Product development ; Prosthesis Design ; Rehabilitation technology ; Studies ; Task Performance and Analysis ; Veterans</subject><ispartof>Journal of rehabilitation research and development, 2009-01, Vol.46 (8), p.1011-1020</ispartof><rights>COPYRIGHT 2009 Department of Veterans Affairs</rights><rights>Copyright Superintendent of Documents 2009</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c506t-2150164370459627f625c3b268ace22ec991db4ad76e3667511684f3e211a3c73</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20157858$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ramirez, Issa A</creatorcontrib><creatorcontrib>Lusk, Craig P</creatorcontrib><creatorcontrib>Dubey, Rajiv</creatorcontrib><creatorcontrib>Highsmith, M Jason</creatorcontrib><creatorcontrib>Maitland, Murray E</creatorcontrib><title>Crossed four-bar mechanism for improved prosthetic grasp</title><title>Journal of rehabilitation research and development</title><addtitle>J Rehabil Res Dev</addtitle><description>Passive linkages were developed to improve grasp functionality and minimize a prosthetic terminal device's number of user-controlled inputs. The linkages act to stabilize grasped objects and substitute for the palp of normal anatomical fingers. The Southampton Hand Assessment Procedure was used to compare the normal anatomical hand, this prototype, and a commercially available (Hosmer) hook. In testing, prosthetic terminal devices took three times as long as the normal anatomical hand to perform tasks. Nevertheless, heavyweight power and spherical grasps were improved with the use of the new mechanism compared with the commercial hook. Conversely, precision grasps were worsened because of the lack of a high-friction surface on the distal end of the prototype.</description><subject>Activities of Daily Living</subject><subject>Artificial arms</subject><subject>Artificial Limbs</subject><subject>Colleges & universities</subject><subject>Design and construction</subject><subject>Hand</subject><subject>Hands</subject><subject>Health aspects</subject><subject>Humans</subject><subject>Motor Skills</subject><subject>Product development</subject><subject>Prosthesis Design</subject><subject>Rehabilitation technology</subject><subject>Studies</subject><subject>Task Performance and Analysis</subject><subject>Veterans</subject><issn>0748-7711</issn><issn>1938-1352</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>8G5</sourceid><sourceid>BEC</sourceid><sourceid>BENPR</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNp9kctOwzAQRS0EouXxAWxQxQJWCZ5x_MiyKm9VQqpgbbmO06ZqkmKnSPw9jlpYsEBejDQ-1zPXl5ALoCkIhbcr74sUKc1TCimlNDsgQ8iZSoBxPCRDKjOVSAkwICchrCKBDOGYDJACl4qrIVET34bgilHZbn0yN35UO7s0TRXq2PKjqt749jPexxK6pesqO1p4EzZn5Kg06-DO9_WUvD_cv02ekunr4_NkPE0sp6JLEDgFkTFJM54LlKVAbtkchTLWITqb51DMM1NI4ZgQkkN0lpXMIYBhVrJTcrN7Ny7wsXWh03UVrFuvTePabdCSMZZJKSCS1_-SCAyoyvIIXv0BV9F8E11EhqNiAP3cdActzNrpqinbzhsbT-HqyraNK6vYHyNKyJUEEQWwE9j-R70r9cZXtfFfGqju49Ivs9md7uPSFHQfV9Rc7jfZzmtX_Cp-8mHfbrGNWw</recordid><startdate>20090101</startdate><enddate>20090101</enddate><creator>Ramirez, Issa A</creator><creator>Lusk, Craig P</creator><creator>Dubey, Rajiv</creator><creator>Highsmith, M Jason</creator><creator>Maitland, Murray E</creator><general>Department of Veterans Affairs</general><general>Superintendent of Documents</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>4T-</scope><scope>7QO</scope><scope>7RV</scope><scope>7TK</scope><scope>7TS</scope><scope>7X7</scope><scope>7XB</scope><scope>88C</scope><scope>88E</scope><scope>88I</scope><scope>8AF</scope><scope>8AO</scope><scope>8FD</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M0T</scope><scope>M1P</scope><scope>M2O</scope><scope>M2P</scope><scope>MBDVC</scope><scope>NAPCQ</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>Q9U</scope><scope>S0X</scope><scope>7X8</scope></search><sort><creationdate>20090101</creationdate><title>Crossed four-bar mechanism for improved prosthetic grasp</title><author>Ramirez, Issa A ; Lusk, Craig P ; Dubey, Rajiv ; Highsmith, M Jason ; Maitland, Murray E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c506t-2150164370459627f625c3b268ace22ec991db4ad76e3667511684f3e211a3c73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Activities of Daily Living</topic><topic>Artificial arms</topic><topic>Artificial Limbs</topic><topic>Colleges & universities</topic><topic>Design and construction</topic><topic>Hand</topic><topic>Hands</topic><topic>Health aspects</topic><topic>Humans</topic><topic>Motor Skills</topic><topic>Product development</topic><topic>Prosthesis Design</topic><topic>Rehabilitation technology</topic><topic>Studies</topic><topic>Task Performance and Analysis</topic><topic>Veterans</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ramirez, Issa A</creatorcontrib><creatorcontrib>Lusk, Craig P</creatorcontrib><creatorcontrib>Dubey, Rajiv</creatorcontrib><creatorcontrib>Highsmith, M Jason</creatorcontrib><creatorcontrib>Maitland, Murray E</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Docstoc</collection><collection>Biotechnology Research Abstracts</collection><collection>Nursing & Allied Health Database</collection><collection>Neurosciences Abstracts</collection><collection>Physical Education Index</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Healthcare Administration Database (Alumni)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>STEM Database</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>eLibrary</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Healthcare Administration Database</collection><collection>Medical Database</collection><collection>Research Library</collection><collection>Science Database</collection><collection>Research Library (Corporate)</collection><collection>Nursing & Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central Basic</collection><collection>SIRS Editorial</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of rehabilitation research and development</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ramirez, Issa A</au><au>Lusk, Craig P</au><au>Dubey, Rajiv</au><au>Highsmith, M Jason</au><au>Maitland, Murray E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Crossed four-bar mechanism for improved prosthetic grasp</atitle><jtitle>Journal of rehabilitation research and development</jtitle><addtitle>J Rehabil Res Dev</addtitle><date>2009-01-01</date><risdate>2009</risdate><volume>46</volume><issue>8</issue><spage>1011</spage><epage>1020</epage><pages>1011-1020</pages><issn>0748-7711</issn><eissn>1938-1352</eissn><coden>JRRDDB</coden><abstract>Passive linkages were developed to improve grasp functionality and minimize a prosthetic terminal device's number of user-controlled inputs. The linkages act to stabilize grasped objects and substitute for the palp of normal anatomical fingers. The Southampton Hand Assessment Procedure was used to compare the normal anatomical hand, this prototype, and a commercially available (Hosmer) hook. In testing, prosthetic terminal devices took three times as long as the normal anatomical hand to perform tasks. Nevertheless, heavyweight power and spherical grasps were improved with the use of the new mechanism compared with the commercial hook. Conversely, precision grasps were worsened because of the lack of a high-friction surface on the distal end of the prototype.</abstract><cop>United States</cop><pub>Department of Veterans Affairs</pub><pmid>20157858</pmid><doi>10.1682/jrrd.2009.01.0004</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0748-7711 |
ispartof | Journal of rehabilitation research and development, 2009-01, Vol.46 (8), p.1011-1020 |
issn | 0748-7711 1938-1352 |
language | eng |
recordid | cdi_proquest_miscellaneous_733347761 |
source | U.S. Government Documents; MEDLINE; EZB-FREE-00999 freely available EZB journals |
subjects | Activities of Daily Living Artificial arms Artificial Limbs Colleges & universities Design and construction Hand Hands Health aspects Humans Motor Skills Product development Prosthesis Design Rehabilitation technology Studies Task Performance and Analysis Veterans |
title | Crossed four-bar mechanism for improved prosthetic grasp |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T11%3A59%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Crossed%20four-bar%20mechanism%20for%20improved%20prosthetic%20grasp&rft.jtitle=Journal%20of%20rehabilitation%20research%20and%20development&rft.au=Ramirez,%20Issa%20A&rft.date=2009-01-01&rft.volume=46&rft.issue=8&rft.spage=1011&rft.epage=1020&rft.pages=1011-1020&rft.issn=0748-7711&rft.eissn=1938-1352&rft.coden=JRRDDB&rft_id=info:doi/10.1682/jrrd.2009.01.0004&rft_dat=%3Cgale_proqu%3EA227198716%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=215283117&rft_id=info:pmid/20157858&rft_galeid=A227198716&rfr_iscdi=true |