Centroid position measurements and subpixel sensitivity variations with the MAMA detector

Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variation...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Optics 1989-03, Vol.28 (6), p.1178-1192
Hauptverfasser: Morgan, Jeffrey S., Slater, D. C., Timothy, John G., Jenkins, E. B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1192
container_issue 6
container_start_page 1178
container_title Applied Optics
container_volume 28
creator Morgan, Jeffrey S.
Slater, D. C.
Timothy, John G.
Jenkins, E. B.
description Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variations of 10-15 percent are typically found for pixels in the array. Variations as large as 30 percent are possible in the worst conditions. These variations limit the photometric accuracy of the detector when very small scale features are observed. The photometric accuracy and the position sensitivity of the detector appear to be limited by cross-coupling effects within the anode array. Initial measurements with more recent designs of the detector show that most or all of this cross-coupling has been eliminated.
doi_str_mv 10.1364/AO.28.001178
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733338312</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733338312</sourcerecordid><originalsourceid>FETCH-LOGICAL-c414t-afcb1e77c5930cf307fabe524565ca5f5ddb3cf948fe72216353a054fa4834f33</originalsourceid><addsrcrecordid>eNo90D1v2zAQBmCiaNC4SbeORcEtS-WSPFIiR8FI2gIJvDRDJoKijggLS3JIKh__PjKc9JYb7sGLw0vIV87WHGr5s92uhV4zxnmjP5AVV2AqqYT4SFaMMahqA-qUfM7532KErs0nciqYkroGvSJ3GxxLmmJP91OOJU4jHdDlOeGwHDJ1Y0_z3O3jM-5oxvFgHmN5oY8uRXfwmT7Fck_LPdKb9qalPRb0ZUrn5CS4XcYvb_uM3F5d_t38rq63v_5s2uvKSy5L5YLvODaNVwaYD8Ca4DpUQqpaeaeC6vsOfDBSB2yE4DUocMv7wUkNMgCckYtj7j5NDzPmYoeYPe52bsRpzraBZTRwscgfR-nTlHPCYPcpDi69WM7soUvbbq3Q9tjlwr-_Bc_dgP1__F7eAr4dweiys0uN2XKjDWPSABh4BRBgeJs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733338312</pqid></control><display><type>article</type><title>Centroid position measurements and subpixel sensitivity variations with the MAMA detector</title><source>NASA Technical Reports Server</source><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Morgan, Jeffrey S. ; Slater, D. C. ; Timothy, John G. ; Jenkins, E. B.</creator><creatorcontrib>Morgan, Jeffrey S. ; Slater, D. C. ; Timothy, John G. ; Jenkins, E. B.</creatorcontrib><description>Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variations of 10-15 percent are typically found for pixels in the array. Variations as large as 30 percent are possible in the worst conditions. These variations limit the photometric accuracy of the detector when very small scale features are observed. The photometric accuracy and the position sensitivity of the detector appear to be limited by cross-coupling effects within the anode array. Initial measurements with more recent designs of the detector show that most or all of this cross-coupling has been eliminated.</description><identifier>ISSN: 0003-6935</identifier><identifier>ISSN: 1559-128X</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.28.001178</identifier><identifier>PMID: 20548638</identifier><language>eng</language><publisher>Legacy CDMS</publisher><subject>Electronics And Electrical Engineering</subject><ispartof>Applied Optics, 1989-03, Vol.28 (6), p.1178-1192</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c414t-afcb1e77c5930cf307fabe524565ca5f5ddb3cf948fe72216353a054fa4834f33</citedby><cites>FETCH-LOGICAL-c414t-afcb1e77c5930cf307fabe524565ca5f5ddb3cf948fe72216353a054fa4834f33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27928,27929</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20548638$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Morgan, Jeffrey S.</creatorcontrib><creatorcontrib>Slater, D. C.</creatorcontrib><creatorcontrib>Timothy, John G.</creatorcontrib><creatorcontrib>Jenkins, E. B.</creatorcontrib><title>Centroid position measurements and subpixel sensitivity variations with the MAMA detector</title><title>Applied Optics</title><addtitle>Appl Opt</addtitle><description>Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variations of 10-15 percent are typically found for pixels in the array. Variations as large as 30 percent are possible in the worst conditions. These variations limit the photometric accuracy of the detector when very small scale features are observed. The photometric accuracy and the position sensitivity of the detector appear to be limited by cross-coupling effects within the anode array. Initial measurements with more recent designs of the detector show that most or all of this cross-coupling has been eliminated.</description><subject>Electronics And Electrical Engineering</subject><issn>0003-6935</issn><issn>1559-128X</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><sourceid>CYI</sourceid><recordid>eNo90D1v2zAQBmCiaNC4SbeORcEtS-WSPFIiR8FI2gIJvDRDJoKijggLS3JIKh__PjKc9JYb7sGLw0vIV87WHGr5s92uhV4zxnmjP5AVV2AqqYT4SFaMMahqA-qUfM7532KErs0nciqYkroGvSJ3GxxLmmJP91OOJU4jHdDlOeGwHDJ1Y0_z3O3jM-5oxvFgHmN5oY8uRXfwmT7Fck_LPdKb9qalPRb0ZUrn5CS4XcYvb_uM3F5d_t38rq63v_5s2uvKSy5L5YLvODaNVwaYD8Ca4DpUQqpaeaeC6vsOfDBSB2yE4DUocMv7wUkNMgCckYtj7j5NDzPmYoeYPe52bsRpzraBZTRwscgfR-nTlHPCYPcpDi69WM7soUvbbq3Q9tjlwr-_Bc_dgP1__F7eAr4dweiys0uN2XKjDWPSABh4BRBgeJs</recordid><startdate>19890315</startdate><enddate>19890315</enddate><creator>Morgan, Jeffrey S.</creator><creator>Slater, D. C.</creator><creator>Timothy, John G.</creator><creator>Jenkins, E. B.</creator><scope>CYE</scope><scope>CYI</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19890315</creationdate><title>Centroid position measurements and subpixel sensitivity variations with the MAMA detector</title><author>Morgan, Jeffrey S. ; Slater, D. C. ; Timothy, John G. ; Jenkins, E. B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c414t-afcb1e77c5930cf307fabe524565ca5f5ddb3cf948fe72216353a054fa4834f33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Electronics And Electrical Engineering</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Morgan, Jeffrey S.</creatorcontrib><creatorcontrib>Slater, D. C.</creatorcontrib><creatorcontrib>Timothy, John G.</creatorcontrib><creatorcontrib>Jenkins, E. B.</creatorcontrib><collection>NASA Scientific and Technical Information</collection><collection>NASA Technical Reports Server</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Applied Optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Morgan, Jeffrey S.</au><au>Slater, D. C.</au><au>Timothy, John G.</au><au>Jenkins, E. B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Centroid position measurements and subpixel sensitivity variations with the MAMA detector</atitle><jtitle>Applied Optics</jtitle><addtitle>Appl Opt</addtitle><date>1989-03-15</date><risdate>1989</risdate><volume>28</volume><issue>6</issue><spage>1178</spage><epage>1192</epage><pages>1178-1192</pages><issn>0003-6935</issn><issn>1559-128X</issn><eissn>1539-4522</eissn><abstract>Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variations of 10-15 percent are typically found for pixels in the array. Variations as large as 30 percent are possible in the worst conditions. These variations limit the photometric accuracy of the detector when very small scale features are observed. The photometric accuracy and the position sensitivity of the detector appear to be limited by cross-coupling effects within the anode array. Initial measurements with more recent designs of the detector show that most or all of this cross-coupling has been eliminated.</abstract><cop>Legacy CDMS</cop><pmid>20548638</pmid><doi>10.1364/AO.28.001178</doi><tpages>15</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-6935
ispartof Applied Optics, 1989-03, Vol.28 (6), p.1178-1192
issn 0003-6935
1559-128X
1539-4522
language eng
recordid cdi_proquest_miscellaneous_733338312
source NASA Technical Reports Server; Alma/SFX Local Collection; Optica Publishing Group Journals
subjects Electronics And Electrical Engineering
title Centroid position measurements and subpixel sensitivity variations with the MAMA detector
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-17T03%3A57%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Centroid%20position%20measurements%20and%20subpixel%20sensitivity%20variations%20with%20the%20MAMA%20detector&rft.jtitle=Applied%20Optics&rft.au=Morgan,%20Jeffrey%20S.&rft.date=1989-03-15&rft.volume=28&rft.issue=6&rft.spage=1178&rft.epage=1192&rft.pages=1178-1192&rft.issn=0003-6935&rft.eissn=1539-4522&rft_id=info:doi/10.1364/AO.28.001178&rft_dat=%3Cproquest_cross%3E733338312%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733338312&rft_id=info:pmid/20548638&rfr_iscdi=true