Operative treatment of distal femoral fractures above total knee arthroplasty with the indirect reduction technique A long-term follow-up study
The complication rate of conventional plate osteosynthesis (CPO) of periprosthetic femoral fractures above total knee arthroplasties (TKA) is high. Indirect reduction techniques were introduced to reduce surgical dissection at the fracture site. Twenty-one patients (4 men and 17 women) with femoral...
Gespeichert in:
Veröffentlicht in: | Injury 2009-04, Vol.40 (4), p.433-439 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 439 |
---|---|
container_issue | 4 |
container_start_page | 433 |
container_title | Injury |
container_volume | 40 |
creator | KOLB, Klaus KOLLER, Heiko LORENZ, Ingo HOLZ, Ulrich MARX, Frank GRÜTZNER, Paul KOLB, Werner |
description | The complication rate of conventional plate osteosynthesis (CPO) of periprosthetic femoral fractures above total knee arthroplasties (TKA) is high. Indirect reduction techniques were introduced to reduce surgical dissection at the fracture site. Twenty-one patients (4 men and 17 women) with femoral fractures above well-fixed total knee arthroplasties were consecutively treated with the indirect reduction technique. AO/ASIF (Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of the Problems of Internal Fixation) Type 33A fractures were included. The mean age was 78 years (range, 67-94 years). Four fractures were stabilised with bone grafts, three in combination with bone cement. Nineteen of the patients were seen at a 1-year follow-up, 15 were seen after a long-term follow-up of 9 years (range, 7-12 years). There was only one implant failure in a comminuted fracture with severe osteoporosis, no infection, and no non-union. At the 1-year follow-up malalignment of 5 degrees varus occurred in one patient. The mean range of motion of the eighteen patients was 98 degrees (range, 65-110 degrees). The mean knee society score was 74 (range, 62-84), the mean function score was 52 (range, 39-72). At the long-term follow-up, the mean range of motion of the patients was 101 degrees (range, 65-115 degrees). The mean knee society score was 77 (range, 65-88), the mean function score was 55 (range, 40-75). Our results suggest the 95 degrees condylar blade plate in the indirect reduction technique is still a good implant with good long-term results. It works best in proximal fractures when there is minimal comminution of the distal fragment in the hands of an experienced trauma surgeon. Knee function and range of motion increased less over time. |
doi_str_mv | 10.1016/j.injury.2008.10.020 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_733323559</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733323559</sourcerecordid><originalsourceid>FETCH-LOGICAL-p240t-329d9c9ce3e64693847656e536a5bb1423b28368ea9a1c1576a8e553b5f07c693</originalsourceid><addsrcrecordid>eNo9kUFv1DAQhS0EotuWf4CQL6inLLYndpJjVUFBqtQLnFeOM2G9OHawJ1T7K_jLzYqlpye9-WY0eo-x91JspZDm02Hr42HJx60Sol2trVDiFdvItukqoUzzmm3EalUSWrhgl6UchJCNAHjLLmSnQOm23rC_jzNmS_4PcspoacJIPI188IVs4CNOKZ80W0dLxsJtn05sOk1_RURuM-1zmoMtdORPnvac9sh9HHxGRzzjsDjyKXJCt4_-94L8locUf1aEeeJjCiE9VcvMCy3D8Zq9GW0o-O6sV-zHl8_f775WD4_33-5uH6pZ1YIqUN3Quc4hoKlNB23dGG1Qg7G672WtoFctmBZtZ6WTujG2Ra2h16No3LpwxW7-3Z1zWl8qtJt8cRiCjZiWsmsAQIHWJ_LDmVz6CYfdnP1k83H3P8MV-HgGbHE2rFFF58sLpyR0cu0DngGxZYUz</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733323559</pqid></control><display><type>article</type><title>Operative treatment of distal femoral fractures above total knee arthroplasty with the indirect reduction technique A long-term follow-up study</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>KOLB, Klaus ; KOLLER, Heiko ; LORENZ, Ingo ; HOLZ, Ulrich ; MARX, Frank ; GRÜTZNER, Paul ; KOLB, Werner</creator><creatorcontrib>KOLB, Klaus ; KOLLER, Heiko ; LORENZ, Ingo ; HOLZ, Ulrich ; MARX, Frank ; GRÜTZNER, Paul ; KOLB, Werner</creatorcontrib><description>The complication rate of conventional plate osteosynthesis (CPO) of periprosthetic femoral fractures above total knee arthroplasties (TKA) is high. Indirect reduction techniques were introduced to reduce surgical dissection at the fracture site. Twenty-one patients (4 men and 17 women) with femoral fractures above well-fixed total knee arthroplasties were consecutively treated with the indirect reduction technique. AO/ASIF (Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of the Problems of Internal Fixation) Type 33A fractures were included. The mean age was 78 years (range, 67-94 years). Four fractures were stabilised with bone grafts, three in combination with bone cement. Nineteen of the patients were seen at a 1-year follow-up, 15 were seen after a long-term follow-up of 9 years (range, 7-12 years). There was only one implant failure in a comminuted fracture with severe osteoporosis, no infection, and no non-union. At the 1-year follow-up malalignment of 5 degrees varus occurred in one patient. The mean range of motion of the eighteen patients was 98 degrees (range, 65-110 degrees). The mean knee society score was 74 (range, 62-84), the mean function score was 52 (range, 39-72). At the long-term follow-up, the mean range of motion of the patients was 101 degrees (range, 65-115 degrees). The mean knee society score was 77 (range, 65-88), the mean function score was 55 (range, 40-75). Our results suggest the 95 degrees condylar blade plate in the indirect reduction technique is still a good implant with good long-term results. It works best in proximal fractures when there is minimal comminution of the distal fragment in the hands of an experienced trauma surgeon. Knee function and range of motion increased less over time.</description><identifier>ISSN: 0020-1383</identifier><identifier>EISSN: 1879-0267</identifier><identifier>DOI: 10.1016/j.injury.2008.10.020</identifier><identifier>PMID: 19232584</identifier><identifier>CODEN: INJUBF</identifier><language>eng</language><publisher>Kidlington: Elsevier</publisher><subject>Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Knee ; Biological and medical sciences ; Bone Plates ; Diseases of the osteoarticular system ; Female ; Femoral Fractures - diagnostic imaging ; Femoral Fractures - surgery ; Follow-Up Studies ; Fracture Fixation, Internal - methods ; Fracture Healing ; Humans ; Injuries of the limb. Injuries of the spine ; Knee Joint - diagnostic imaging ; Knee Joint - physiopathology ; Male ; Medical sciences ; Orthopedic surgery ; Radiography ; Range of Motion, Articular ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Traumas. Diseases due to physical agents ; Treatment Outcome</subject><ispartof>Injury, 2009-04, Vol.40 (4), p.433-439</ispartof><rights>2009 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=21391267$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19232584$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>KOLB, Klaus</creatorcontrib><creatorcontrib>KOLLER, Heiko</creatorcontrib><creatorcontrib>LORENZ, Ingo</creatorcontrib><creatorcontrib>HOLZ, Ulrich</creatorcontrib><creatorcontrib>MARX, Frank</creatorcontrib><creatorcontrib>GRÜTZNER, Paul</creatorcontrib><creatorcontrib>KOLB, Werner</creatorcontrib><title>Operative treatment of distal femoral fractures above total knee arthroplasty with the indirect reduction technique A long-term follow-up study</title><title>Injury</title><addtitle>Injury</addtitle><description>The complication rate of conventional plate osteosynthesis (CPO) of periprosthetic femoral fractures above total knee arthroplasties (TKA) is high. Indirect reduction techniques were introduced to reduce surgical dissection at the fracture site. Twenty-one patients (4 men and 17 women) with femoral fractures above well-fixed total knee arthroplasties were consecutively treated with the indirect reduction technique. AO/ASIF (Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of the Problems of Internal Fixation) Type 33A fractures were included. The mean age was 78 years (range, 67-94 years). Four fractures were stabilised with bone grafts, three in combination with bone cement. Nineteen of the patients were seen at a 1-year follow-up, 15 were seen after a long-term follow-up of 9 years (range, 7-12 years). There was only one implant failure in a comminuted fracture with severe osteoporosis, no infection, and no non-union. At the 1-year follow-up malalignment of 5 degrees varus occurred in one patient. The mean range of motion of the eighteen patients was 98 degrees (range, 65-110 degrees). The mean knee society score was 74 (range, 62-84), the mean function score was 52 (range, 39-72). At the long-term follow-up, the mean range of motion of the patients was 101 degrees (range, 65-115 degrees). The mean knee society score was 77 (range, 65-88), the mean function score was 55 (range, 40-75). Our results suggest the 95 degrees condylar blade plate in the indirect reduction technique is still a good implant with good long-term results. It works best in proximal fractures when there is minimal comminution of the distal fragment in the hands of an experienced trauma surgeon. Knee function and range of motion increased less over time.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Arthroplasty, Replacement, Knee</subject><subject>Biological and medical sciences</subject><subject>Bone Plates</subject><subject>Diseases of the osteoarticular system</subject><subject>Female</subject><subject>Femoral Fractures - diagnostic imaging</subject><subject>Femoral Fractures - surgery</subject><subject>Follow-Up Studies</subject><subject>Fracture Fixation, Internal - methods</subject><subject>Fracture Healing</subject><subject>Humans</subject><subject>Injuries of the limb. Injuries of the spine</subject><subject>Knee Joint - diagnostic imaging</subject><subject>Knee Joint - physiopathology</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Orthopedic surgery</subject><subject>Radiography</subject><subject>Range of Motion, Articular</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Traumas. Diseases due to physical agents</subject><subject>Treatment Outcome</subject><issn>0020-1383</issn><issn>1879-0267</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kUFv1DAQhS0EotuWf4CQL6inLLYndpJjVUFBqtQLnFeOM2G9OHawJ1T7K_jLzYqlpye9-WY0eo-x91JspZDm02Hr42HJx60Sol2trVDiFdvItukqoUzzmm3EalUSWrhgl6UchJCNAHjLLmSnQOm23rC_jzNmS_4PcspoacJIPI188IVs4CNOKZ80W0dLxsJtn05sOk1_RURuM-1zmoMtdORPnvac9sh9HHxGRzzjsDjyKXJCt4_-94L8locUf1aEeeJjCiE9VcvMCy3D8Zq9GW0o-O6sV-zHl8_f775WD4_33-5uH6pZ1YIqUN3Quc4hoKlNB23dGG1Qg7G672WtoFctmBZtZ6WTujG2Ra2h16No3LpwxW7-3Z1zWl8qtJt8cRiCjZiWsmsAQIHWJ_LDmVz6CYfdnP1k83H3P8MV-HgGbHE2rFFF58sLpyR0cu0DngGxZYUz</recordid><startdate>20090401</startdate><enddate>20090401</enddate><creator>KOLB, Klaus</creator><creator>KOLLER, Heiko</creator><creator>LORENZ, Ingo</creator><creator>HOLZ, Ulrich</creator><creator>MARX, Frank</creator><creator>GRÜTZNER, Paul</creator><creator>KOLB, Werner</creator><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20090401</creationdate><title>Operative treatment of distal femoral fractures above total knee arthroplasty with the indirect reduction technique A long-term follow-up study</title><author>KOLB, Klaus ; KOLLER, Heiko ; LORENZ, Ingo ; HOLZ, Ulrich ; MARX, Frank ; GRÜTZNER, Paul ; KOLB, Werner</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p240t-329d9c9ce3e64693847656e536a5bb1423b28368ea9a1c1576a8e553b5f07c693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Arthroplasty, Replacement, Knee</topic><topic>Biological and medical sciences</topic><topic>Bone Plates</topic><topic>Diseases of the osteoarticular system</topic><topic>Female</topic><topic>Femoral Fractures - diagnostic imaging</topic><topic>Femoral Fractures - surgery</topic><topic>Follow-Up Studies</topic><topic>Fracture Fixation, Internal - methods</topic><topic>Fracture Healing</topic><topic>Humans</topic><topic>Injuries of the limb. Injuries of the spine</topic><topic>Knee Joint - diagnostic imaging</topic><topic>Knee Joint - physiopathology</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Orthopedic surgery</topic><topic>Radiography</topic><topic>Range of Motion, Articular</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Traumas. Diseases due to physical agents</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>KOLB, Klaus</creatorcontrib><creatorcontrib>KOLLER, Heiko</creatorcontrib><creatorcontrib>LORENZ, Ingo</creatorcontrib><creatorcontrib>HOLZ, Ulrich</creatorcontrib><creatorcontrib>MARX, Frank</creatorcontrib><creatorcontrib>GRÜTZNER, Paul</creatorcontrib><creatorcontrib>KOLB, Werner</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Injury</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>KOLB, Klaus</au><au>KOLLER, Heiko</au><au>LORENZ, Ingo</au><au>HOLZ, Ulrich</au><au>MARX, Frank</au><au>GRÜTZNER, Paul</au><au>KOLB, Werner</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Operative treatment of distal femoral fractures above total knee arthroplasty with the indirect reduction technique A long-term follow-up study</atitle><jtitle>Injury</jtitle><addtitle>Injury</addtitle><date>2009-04-01</date><risdate>2009</risdate><volume>40</volume><issue>4</issue><spage>433</spage><epage>439</epage><pages>433-439</pages><issn>0020-1383</issn><eissn>1879-0267</eissn><coden>INJUBF</coden><abstract>The complication rate of conventional plate osteosynthesis (CPO) of periprosthetic femoral fractures above total knee arthroplasties (TKA) is high. Indirect reduction techniques were introduced to reduce surgical dissection at the fracture site. Twenty-one patients (4 men and 17 women) with femoral fractures above well-fixed total knee arthroplasties were consecutively treated with the indirect reduction technique. AO/ASIF (Arbeitsgemeinschaft für Osteosynthesefragen/Association for the Study of the Problems of Internal Fixation) Type 33A fractures were included. The mean age was 78 years (range, 67-94 years). Four fractures were stabilised with bone grafts, three in combination with bone cement. Nineteen of the patients were seen at a 1-year follow-up, 15 were seen after a long-term follow-up of 9 years (range, 7-12 years). There was only one implant failure in a comminuted fracture with severe osteoporosis, no infection, and no non-union. At the 1-year follow-up malalignment of 5 degrees varus occurred in one patient. The mean range of motion of the eighteen patients was 98 degrees (range, 65-110 degrees). The mean knee society score was 74 (range, 62-84), the mean function score was 52 (range, 39-72). At the long-term follow-up, the mean range of motion of the patients was 101 degrees (range, 65-115 degrees). The mean knee society score was 77 (range, 65-88), the mean function score was 55 (range, 40-75). Our results suggest the 95 degrees condylar blade plate in the indirect reduction technique is still a good implant with good long-term results. It works best in proximal fractures when there is minimal comminution of the distal fragment in the hands of an experienced trauma surgeon. Knee function and range of motion increased less over time.</abstract><cop>Kidlington</cop><pub>Elsevier</pub><pmid>19232584</pmid><doi>10.1016/j.injury.2008.10.020</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0020-1383 |
ispartof | Injury, 2009-04, Vol.40 (4), p.433-439 |
issn | 0020-1383 1879-0267 |
language | eng |
recordid | cdi_proquest_miscellaneous_733323559 |
source | MEDLINE; Access via ScienceDirect (Elsevier) |
subjects | Aged Aged, 80 and over Arthroplasty, Replacement, Knee Biological and medical sciences Bone Plates Diseases of the osteoarticular system Female Femoral Fractures - diagnostic imaging Femoral Fractures - surgery Follow-Up Studies Fracture Fixation, Internal - methods Fracture Healing Humans Injuries of the limb. Injuries of the spine Knee Joint - diagnostic imaging Knee Joint - physiopathology Male Medical sciences Orthopedic surgery Radiography Range of Motion, Articular Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Traumas. Diseases due to physical agents Treatment Outcome |
title | Operative treatment of distal femoral fractures above total knee arthroplasty with the indirect reduction technique A long-term follow-up study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T15%3A16%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Operative%20treatment%20of%20distal%20femoral%20fractures%20above%20total%20knee%20arthroplasty%20with%20the%20indirect%20reduction%20technique%20A%20long-term%20follow-up%20study&rft.jtitle=Injury&rft.au=KOLB,%20Klaus&rft.date=2009-04-01&rft.volume=40&rft.issue=4&rft.spage=433&rft.epage=439&rft.pages=433-439&rft.issn=0020-1383&rft.eissn=1879-0267&rft.coden=INJUBF&rft_id=info:doi/10.1016/j.injury.2008.10.020&rft_dat=%3Cproquest_pubme%3E733323559%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733323559&rft_id=info:pmid/19232584&rfr_iscdi=true |