STATIONARITY OF THE HEART RATE VARIABILITY BY ACCELERATION PLETHYSMOGRAPHY: SHORT-TERM MEASUREMENTS OF HEALTHY YOUNG MALES IN DAILY LIFE

The acceleration plethysmography (APG) is a useful tool to analyze the heart rate variability (HRV) with the merits of being portable and simple in operation. To use it clinically, ‘stationarity' of the HRV measurements in resting state should be justified as a fundamental premise. Therefore, t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Human Ergology 2009, Vol.38(2), pp.41-50
Hauptverfasser: TAKADA, MIKIO, EBARA, TAKESHI, SAKAI, YASUSHI, KUWANO, YASUHIRO
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 50
container_issue 2
container_start_page 41
container_title Journal of Human Ergology
container_volume 38
creator TAKADA, MIKIO
EBARA, TAKESHI
SAKAI, YASUSHI
KUWANO, YASUHIRO
description The acceleration plethysmography (APG) is a useful tool to analyze the heart rate variability (HRV) with the merits of being portable and simple in operation. To use it clinically, ‘stationarity' of the HRV measurements in resting state should be justified as a fundamental premise. Therefore, the purpose of this research was to investigate the stationarity of the short-term HRV derived from APG in resting state in daily life. The sample size was determined on the basis of α=0.05 and β=0.20. The HRV measurements of 44 healthy male subjects were done twice during a one-week period by the APG system. The HRV parameters were examined by the assessments of distribution, equality of the mean and variance and internal consistency reliability. Concerning spectral components represented as proportion, normalized units and the logarithm of the rate of each component, the normal distribution and the homogeneity of variance in two measurements were confirmed. Significant difference was not found between the mean values in two measurements. The internal consistency reliability evaluated by Cronbach's α of 0.6-0.7 was acceptable for every parameter. It is concluded that for healthy young males, the parameters of short-term HRV derived from APG measured in resting state in the same time zone in daily life remain stationary within a certain range regardless of the measurement day.
doi_str_mv 10.11183/jhe.38.41
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_733118470</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733118470</sourcerecordid><originalsourceid>FETCH-LOGICAL-j325t-cbf91553cabab0e5cbfc6a5d037102b130f466c3365d78d23f4f17f6e20b18603</originalsourceid><addsrcrecordid>eNo9kU1OwzAQhS0EglLYcADkHasUO-MkLmJjittEchqUuEhZRU7qQKu2QNIuuAHHJuWnmxnNvG_e4g1CV5QMKKUcbpevdgB8wOgR6lHOmQNDnx2jHgFCHE6BnaHztl0Swobc9U_RmUsYBJy6PfSVaaGjZCrSSOc4GWMdShxKkWqcCi3xcyeIh0jt1Ycci9FIKpn-nOAnJXWYZ3EyScVTmN_hLExS7WiZxjiWIpulMpZTne1tO0vVwThPZtMJjoWSGY6m-FFEKscqGssLdFKbVWsv_3ofzcZSj0JHJZNoJJSzBNfbOlVZD6nnQWVKUxLrdXPlG29OIKDELSmQmvl-BeB784DPXahZTYPaty4pKfcJ9NHNr-978_axs-22WC_ayq5WZmPfdm0RAHSZsmBPXv-Ru3Jt58V7s1ib5rP4D68D7n-BZbs1L_YAmGa7qFa26N5SAC_cfWH0sK5eTVPYDXwD1r97eg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733118470</pqid></control><display><type>article</type><title>STATIONARITY OF THE HEART RATE VARIABILITY BY ACCELERATION PLETHYSMOGRAPHY: SHORT-TERM MEASUREMENTS OF HEALTHY YOUNG MALES IN DAILY LIFE</title><source>J-STAGE Free</source><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>TAKADA, MIKIO ; EBARA, TAKESHI ; SAKAI, YASUSHI ; KUWANO, YASUHIRO</creator><creatorcontrib>TAKADA, MIKIO ; EBARA, TAKESHI ; SAKAI, YASUSHI ; KUWANO, YASUHIRO</creatorcontrib><description>The acceleration plethysmography (APG) is a useful tool to analyze the heart rate variability (HRV) with the merits of being portable and simple in operation. To use it clinically, ‘stationarity' of the HRV measurements in resting state should be justified as a fundamental premise. Therefore, the purpose of this research was to investigate the stationarity of the short-term HRV derived from APG in resting state in daily life. The sample size was determined on the basis of α=0.05 and β=0.20. The HRV measurements of 44 healthy male subjects were done twice during a one-week period by the APG system. The HRV parameters were examined by the assessments of distribution, equality of the mean and variance and internal consistency reliability. Concerning spectral components represented as proportion, normalized units and the logarithm of the rate of each component, the normal distribution and the homogeneity of variance in two measurements were confirmed. Significant difference was not found between the mean values in two measurements. The internal consistency reliability evaluated by Cronbach's α of 0.6-0.7 was acceptable for every parameter. It is concluded that for healthy young males, the parameters of short-term HRV derived from APG measured in resting state in the same time zone in daily life remain stationary within a certain range regardless of the measurement day.</description><identifier>ISSN: 0300-8134</identifier><identifier>EISSN: 1884-3964</identifier><identifier>DOI: 10.11183/jhe.38.41</identifier><identifier>PMID: 20437812</identifier><language>eng</language><publisher>Japan: Human Ergology Society</publisher><subject>Acceleration ; acceleration plethysmography ; Activities of Daily Living ; Adult ; autonomic nerve ; Autonomic Pathways ; frequency analysis ; Heart Rate - physiology ; heart rate variability ; Humans ; Male ; Middle Aged ; Plethysmography - methods</subject><ispartof>Journal of Human Ergology, 2009, Vol.38(2), pp.41-50</ispartof><rights>2009 Human Ergology Society</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,4010,27900,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20437812$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>TAKADA, MIKIO</creatorcontrib><creatorcontrib>EBARA, TAKESHI</creatorcontrib><creatorcontrib>SAKAI, YASUSHI</creatorcontrib><creatorcontrib>KUWANO, YASUHIRO</creatorcontrib><title>STATIONARITY OF THE HEART RATE VARIABILITY BY ACCELERATION PLETHYSMOGRAPHY: SHORT-TERM MEASUREMENTS OF HEALTHY YOUNG MALES IN DAILY LIFE</title><title>Journal of Human Ergology</title><addtitle>J. Hum. Ergol.</addtitle><description>The acceleration plethysmography (APG) is a useful tool to analyze the heart rate variability (HRV) with the merits of being portable and simple in operation. To use it clinically, ‘stationarity' of the HRV measurements in resting state should be justified as a fundamental premise. Therefore, the purpose of this research was to investigate the stationarity of the short-term HRV derived from APG in resting state in daily life. The sample size was determined on the basis of α=0.05 and β=0.20. The HRV measurements of 44 healthy male subjects were done twice during a one-week period by the APG system. The HRV parameters were examined by the assessments of distribution, equality of the mean and variance and internal consistency reliability. Concerning spectral components represented as proportion, normalized units and the logarithm of the rate of each component, the normal distribution and the homogeneity of variance in two measurements were confirmed. Significant difference was not found between the mean values in two measurements. The internal consistency reliability evaluated by Cronbach's α of 0.6-0.7 was acceptable for every parameter. It is concluded that for healthy young males, the parameters of short-term HRV derived from APG measured in resting state in the same time zone in daily life remain stationary within a certain range regardless of the measurement day.</description><subject>Acceleration</subject><subject>acceleration plethysmography</subject><subject>Activities of Daily Living</subject><subject>Adult</subject><subject>autonomic nerve</subject><subject>Autonomic Pathways</subject><subject>frequency analysis</subject><subject>Heart Rate - physiology</subject><subject>heart rate variability</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Plethysmography - methods</subject><issn>0300-8134</issn><issn>1884-3964</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kU1OwzAQhS0EglLYcADkHasUO-MkLmJjittEchqUuEhZRU7qQKu2QNIuuAHHJuWnmxnNvG_e4g1CV5QMKKUcbpevdgB8wOgR6lHOmQNDnx2jHgFCHE6BnaHztl0Swobc9U_RmUsYBJy6PfSVaaGjZCrSSOc4GWMdShxKkWqcCi3xcyeIh0jt1Ycci9FIKpn-nOAnJXWYZ3EyScVTmN_hLExS7WiZxjiWIpulMpZTne1tO0vVwThPZtMJjoWSGY6m-FFEKscqGssLdFKbVWsv_3ofzcZSj0JHJZNoJJSzBNfbOlVZD6nnQWVKUxLrdXPlG29OIKDELSmQmvl-BeB784DPXahZTYPaty4pKfcJ9NHNr-978_axs-22WC_ayq5WZmPfdm0RAHSZsmBPXv-Ru3Jt58V7s1ib5rP4D68D7n-BZbs1L_YAmGa7qFa26N5SAC_cfWH0sK5eTVPYDXwD1r97eg</recordid><startdate>2009</startdate><enddate>2009</enddate><creator>TAKADA, MIKIO</creator><creator>EBARA, TAKESHI</creator><creator>SAKAI, YASUSHI</creator><creator>KUWANO, YASUHIRO</creator><general>Human Ergology Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>2009</creationdate><title>STATIONARITY OF THE HEART RATE VARIABILITY BY ACCELERATION PLETHYSMOGRAPHY: SHORT-TERM MEASUREMENTS OF HEALTHY YOUNG MALES IN DAILY LIFE</title><author>TAKADA, MIKIO ; EBARA, TAKESHI ; SAKAI, YASUSHI ; KUWANO, YASUHIRO</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j325t-cbf91553cabab0e5cbfc6a5d037102b130f466c3365d78d23f4f17f6e20b18603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Acceleration</topic><topic>acceleration plethysmography</topic><topic>Activities of Daily Living</topic><topic>Adult</topic><topic>autonomic nerve</topic><topic>Autonomic Pathways</topic><topic>frequency analysis</topic><topic>Heart Rate - physiology</topic><topic>heart rate variability</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Plethysmography - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>TAKADA, MIKIO</creatorcontrib><creatorcontrib>EBARA, TAKESHI</creatorcontrib><creatorcontrib>SAKAI, YASUSHI</creatorcontrib><creatorcontrib>KUWANO, YASUHIRO</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of Human Ergology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>TAKADA, MIKIO</au><au>EBARA, TAKESHI</au><au>SAKAI, YASUSHI</au><au>KUWANO, YASUHIRO</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>STATIONARITY OF THE HEART RATE VARIABILITY BY ACCELERATION PLETHYSMOGRAPHY: SHORT-TERM MEASUREMENTS OF HEALTHY YOUNG MALES IN DAILY LIFE</atitle><jtitle>Journal of Human Ergology</jtitle><addtitle>J. Hum. Ergol.</addtitle><date>2009</date><risdate>2009</risdate><volume>38</volume><issue>2</issue><spage>41</spage><epage>50</epage><pages>41-50</pages><issn>0300-8134</issn><eissn>1884-3964</eissn><abstract>The acceleration plethysmography (APG) is a useful tool to analyze the heart rate variability (HRV) with the merits of being portable and simple in operation. To use it clinically, ‘stationarity' of the HRV measurements in resting state should be justified as a fundamental premise. Therefore, the purpose of this research was to investigate the stationarity of the short-term HRV derived from APG in resting state in daily life. The sample size was determined on the basis of α=0.05 and β=0.20. The HRV measurements of 44 healthy male subjects were done twice during a one-week period by the APG system. The HRV parameters were examined by the assessments of distribution, equality of the mean and variance and internal consistency reliability. Concerning spectral components represented as proportion, normalized units and the logarithm of the rate of each component, the normal distribution and the homogeneity of variance in two measurements were confirmed. Significant difference was not found between the mean values in two measurements. The internal consistency reliability evaluated by Cronbach's α of 0.6-0.7 was acceptable for every parameter. It is concluded that for healthy young males, the parameters of short-term HRV derived from APG measured in resting state in the same time zone in daily life remain stationary within a certain range regardless of the measurement day.</abstract><cop>Japan</cop><pub>Human Ergology Society</pub><pmid>20437812</pmid><doi>10.11183/jhe.38.41</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0300-8134
ispartof Journal of Human Ergology, 2009, Vol.38(2), pp.41-50
issn 0300-8134
1884-3964
language eng
recordid cdi_proquest_miscellaneous_733118470
source J-STAGE Free; MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Acceleration
acceleration plethysmography
Activities of Daily Living
Adult
autonomic nerve
Autonomic Pathways
frequency analysis
Heart Rate - physiology
heart rate variability
Humans
Male
Middle Aged
Plethysmography - methods
title STATIONARITY OF THE HEART RATE VARIABILITY BY ACCELERATION PLETHYSMOGRAPHY: SHORT-TERM MEASUREMENTS OF HEALTHY YOUNG MALES IN DAILY LIFE
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T06%3A01%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=STATIONARITY%20OF%20THE%20HEART%20RATE%20VARIABILITY%20BY%20ACCELERATION%20PLETHYSMOGRAPHY:%20SHORT-TERM%20MEASUREMENTS%20OF%20HEALTHY%20YOUNG%20MALES%20IN%20DAILY%20LIFE&rft.jtitle=Journal%20of%20Human%20Ergology&rft.au=TAKADA,%20MIKIO&rft.date=2009&rft.volume=38&rft.issue=2&rft.spage=41&rft.epage=50&rft.pages=41-50&rft.issn=0300-8134&rft.eissn=1884-3964&rft_id=info:doi/10.11183/jhe.38.41&rft_dat=%3Cproquest_pubme%3E733118470%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733118470&rft_id=info:pmid/20437812&rfr_iscdi=true