Imaging with microstructured polymer fibre

The imaging capabilities of a multicore microstructured polymer optical fibre with a square array of 112 air holes are demonstrated. Coherent imaging is achieved either by guiding light in polymer cores between air holes, or by guiding light in the air channels themselves. This potentially provides...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics express 2004-01, Vol.12 (2), p.342-346
1. Verfasser: van Eijkelenborg, Martijn
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 346
container_issue 2
container_start_page 342
container_title Optics express
container_volume 12
creator van Eijkelenborg, Martijn
description The imaging capabilities of a multicore microstructured polymer optical fibre with a square array of 112 air holes are demonstrated. Coherent imaging is achieved either by guiding light in polymer cores between air holes, or by guiding light in the air channels themselves. This potentially provides a miniaturised endoscope for medical applications, or a two-dimensional parallel optical data link for high-bandwidth interconnects.
doi_str_mv 10.1364/OPEX.12.000342
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_733103356</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>733103356</sourcerecordid><originalsourceid>FETCH-LOGICAL-c332t-94d057181f3b6335c53f71664c9c0e66b86ac5f4c0325f2c32167c1eab9e0cb53</originalsourceid><addsrcrecordid>eNpNkE1Lw0AQQBdRbK1ePUpugpA4s7MfzVFK1UKhHhS8Lcl2t0aSpu4mlP57W1rQ08zhzWN4jN0iZEhKPC7epp8Z8gwASPAzNkTIRSpgrM__7QN2FeM3AAqd60s2wFxolIKG7GHWFKtqvUq2VfeVNJUNbexCb7s-uGWyaetd40LiqzK4a3bhizq6m9McsY_n6fvkNZ0vXmaTp3lqiXiX5mIJUuMYPZWKSFpJXqNSwuYWnFLlWBVWemGBuPTcEkelLbqizB3YUtKI3R-9m9D-9C52pqmidXVdrF3bR6OJEPZitSezI3n4OgbnzSZUTRF2BsEc8phDHoPcHPPsD-5O6r5s3PIPP_WgXxBSXtw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>733103356</pqid></control><display><type>article</type><title>Imaging with microstructured polymer fibre</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>van Eijkelenborg, Martijn</creator><creatorcontrib>van Eijkelenborg, Martijn</creatorcontrib><description>The imaging capabilities of a multicore microstructured polymer optical fibre with a square array of 112 air holes are demonstrated. Coherent imaging is achieved either by guiding light in polymer cores between air holes, or by guiding light in the air channels themselves. This potentially provides a miniaturised endoscope for medical applications, or a two-dimensional parallel optical data link for high-bandwidth interconnects.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OPEX.12.000342</identifier><identifier>PMID: 19471543</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2004-01, Vol.12 (2), p.342-346</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c332t-94d057181f3b6335c53f71664c9c0e66b86ac5f4c0325f2c32167c1eab9e0cb53</citedby><cites>FETCH-LOGICAL-c332t-94d057181f3b6335c53f71664c9c0e66b86ac5f4c0325f2c32167c1eab9e0cb53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/19471543$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>van Eijkelenborg, Martijn</creatorcontrib><title>Imaging with microstructured polymer fibre</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>The imaging capabilities of a multicore microstructured polymer optical fibre with a square array of 112 air holes are demonstrated. Coherent imaging is achieved either by guiding light in polymer cores between air holes, or by guiding light in the air channels themselves. This potentially provides a miniaturised endoscope for medical applications, or a two-dimensional parallel optical data link for high-bandwidth interconnects.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNpNkE1Lw0AQQBdRbK1ePUpugpA4s7MfzVFK1UKhHhS8Lcl2t0aSpu4mlP57W1rQ08zhzWN4jN0iZEhKPC7epp8Z8gwASPAzNkTIRSpgrM__7QN2FeM3AAqd60s2wFxolIKG7GHWFKtqvUq2VfeVNJUNbexCb7s-uGWyaetd40LiqzK4a3bhizq6m9McsY_n6fvkNZ0vXmaTp3lqiXiX5mIJUuMYPZWKSFpJXqNSwuYWnFLlWBVWemGBuPTcEkelLbqizB3YUtKI3R-9m9D-9C52pqmidXVdrF3bR6OJEPZitSezI3n4OgbnzSZUTRF2BsEc8phDHoPcHPPsD-5O6r5s3PIPP_WgXxBSXtw</recordid><startdate>20040126</startdate><enddate>20040126</enddate><creator>van Eijkelenborg, Martijn</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20040126</creationdate><title>Imaging with microstructured polymer fibre</title><author>van Eijkelenborg, Martijn</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c332t-94d057181f3b6335c53f71664c9c0e66b86ac5f4c0325f2c32167c1eab9e0cb53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>van Eijkelenborg, Martijn</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>van Eijkelenborg, Martijn</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Imaging with microstructured polymer fibre</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2004-01-26</date><risdate>2004</risdate><volume>12</volume><issue>2</issue><spage>342</spage><epage>346</epage><pages>342-346</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>The imaging capabilities of a multicore microstructured polymer optical fibre with a square array of 112 air holes are demonstrated. Coherent imaging is achieved either by guiding light in polymer cores between air holes, or by guiding light in the air channels themselves. This potentially provides a miniaturised endoscope for medical applications, or a two-dimensional parallel optical data link for high-bandwidth interconnects.</abstract><cop>United States</cop><pmid>19471543</pmid><doi>10.1364/OPEX.12.000342</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1094-4087
ispartof Optics express, 2004-01, Vol.12 (2), p.342-346
issn 1094-4087
1094-4087
language eng
recordid cdi_proquest_miscellaneous_733103356
source DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
title Imaging with microstructured polymer fibre
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T11%3A34%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Imaging%20with%20microstructured%20polymer%20fibre&rft.jtitle=Optics%20express&rft.au=van%20Eijkelenborg,%20Martijn&rft.date=2004-01-26&rft.volume=12&rft.issue=2&rft.spage=342&rft.epage=346&rft.pages=342-346&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OPEX.12.000342&rft_dat=%3Cproquest_cross%3E733103356%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=733103356&rft_id=info:pmid/19471543&rfr_iscdi=true