MR Imaging-Guided Adrenal Biopsy Using an Open Low-Field-Strength Scanner and MR Fluoroscopy

The aim of our study was to test the feasibility and specific properties of MR imaging-guided adrenal biopsy using an open 0.2-T scanner and MR fluoroscopic fast imaging with steady-state free precession sequences. MR imaging-guided biopsy of the adrenal gland is feasible and safe. In all patients,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2003-06, Vol.180 (6), p.1567-1570
Hauptverfasser: Konig, Claudius W, Pereira, Philippe L, Trubenbach, Jochen, Fritz, Jan, Duda, Stephan H, Schick, Fritz, Claussen, Claus D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1570
container_issue 6
container_start_page 1567
container_title American journal of roentgenology (1976)
container_volume 180
creator Konig, Claudius W
Pereira, Philippe L
Trubenbach, Jochen
Fritz, Jan
Duda, Stephan H
Schick, Fritz
Claussen, Claus D
description The aim of our study was to test the feasibility and specific properties of MR imaging-guided adrenal biopsy using an open 0.2-T scanner and MR fluoroscopic fast imaging with steady-state free precession sequences. MR imaging-guided biopsy of the adrenal gland is feasible and safe. In all patients, appropriate specimens were obtained with full diagnostic yield and accuracy. MR fluoroscopy is particularly useful to establish an oblique paravertebral access without pleural transgression. For final needle placement, supplementary breath-hold multislice sequences are required in most cases.
doi_str_mv 10.2214/ajr.180.6.1801567
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73291496</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73291496</sourcerecordid><originalsourceid>FETCH-LOGICAL-c359t-b4dbcbd61f13d91ac7789e6e412f57823c2a1592fb980a3e19927a896c36330c3</originalsourceid><addsrcrecordid>eNpFkE1r3DAQhkVISTZJf0AuQZc0J281ki1bxzR008CWQNJADwUhS_KugvwRaY3Zf18ta8hl5jDPvDM8CF0DWVIK-Xf1HpZQkSU_VCh4eYIWUOQ8Y5DDKVoQxiGrCPt7ji5ifCeElJUoz9A50JITQWGB_v1-wU-t2rhukz2OzliD702wnfL4h-uHuMdvMc2w6vDzYDu87qds5aw32esuYZvdFr9q1XU2JMTglLbyYx_6qPthf4W-NMpH-3Xul-ht9fPPw69s_fz49HC_zjQrxC6rc1Pr2nBogBkBSpfpTcttDrQpyooyTRUUgja1qIhiFoSgpaoE14wzRjS7RN-OuUPoP0Ybd7J1UVvvVWf7McqSUQG54AmEI6jThzHYRg7BtSrsJRB5UCqTUplkSi5npWnnZg4f69aaz43ZYQJuZ0BFrXwTVKdd_OTyKmeC0cTdHbmt22wnF6yMrfI-xYKcpmm-ejj5Hw2ai2s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73291496</pqid></control><display><type>article</type><title>MR Imaging-Guided Adrenal Biopsy Using an Open Low-Field-Strength Scanner and MR Fluoroscopy</title><source>American Roentgen Ray Society</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Konig, Claudius W ; Pereira, Philippe L ; Trubenbach, Jochen ; Fritz, Jan ; Duda, Stephan H ; Schick, Fritz ; Claussen, Claus D</creator><creatorcontrib>Konig, Claudius W ; Pereira, Philippe L ; Trubenbach, Jochen ; Fritz, Jan ; Duda, Stephan H ; Schick, Fritz ; Claussen, Claus D</creatorcontrib><description>The aim of our study was to test the feasibility and specific properties of MR imaging-guided adrenal biopsy using an open 0.2-T scanner and MR fluoroscopic fast imaging with steady-state free precession sequences. MR imaging-guided biopsy of the adrenal gland is feasible and safe. In all patients, appropriate specimens were obtained with full diagnostic yield and accuracy. MR fluoroscopy is particularly useful to establish an oblique paravertebral access without pleural transgression. For final needle placement, supplementary breath-hold multislice sequences are required in most cases.</description><identifier>ISSN: 0361-803X</identifier><identifier>EISSN: 1546-3141</identifier><identifier>DOI: 10.2214/ajr.180.6.1801567</identifier><identifier>PMID: 12760921</identifier><identifier>CODEN: AAJRDX</identifier><language>eng</language><publisher>Leesburg, VA: Am Roentgen Ray Soc</publisher><subject>Adrenal Gland Neoplasms - diagnostic imaging ; Adrenal Gland Neoplasms - pathology ; Adrenals. Adrenal axis. Renin-angiotensin system (diseases) ; Aged ; Biological and medical sciences ; Biopsy - adverse effects ; Biopsy - methods ; Computer Systems ; Endocrinopathies ; Female ; Fluoroscopy - adverse effects ; Fluoroscopy - methods ; Humans ; Magnetic Resonance Imaging - adverse effects ; Magnetic Resonance Imaging - methods ; Male ; Malignant tumors ; Medical sciences ; Middle Aged ; Postoperative Complications ; Reproducibility of Results ; Surgery, Computer-Assisted - methods ; Time Factors</subject><ispartof>American journal of roentgenology (1976), 2003-06, Vol.180 (6), p.1567-1570</ispartof><rights>2003 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c359t-b4dbcbd61f13d91ac7789e6e412f57823c2a1592fb980a3e19927a896c36330c3</citedby><cites>FETCH-LOGICAL-c359t-b4dbcbd61f13d91ac7789e6e412f57823c2a1592fb980a3e19927a896c36330c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,4106,27905,27906</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=14843932$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12760921$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Konig, Claudius W</creatorcontrib><creatorcontrib>Pereira, Philippe L</creatorcontrib><creatorcontrib>Trubenbach, Jochen</creatorcontrib><creatorcontrib>Fritz, Jan</creatorcontrib><creatorcontrib>Duda, Stephan H</creatorcontrib><creatorcontrib>Schick, Fritz</creatorcontrib><creatorcontrib>Claussen, Claus D</creatorcontrib><title>MR Imaging-Guided Adrenal Biopsy Using an Open Low-Field-Strength Scanner and MR Fluoroscopy</title><title>American journal of roentgenology (1976)</title><addtitle>AJR Am J Roentgenol</addtitle><description>The aim of our study was to test the feasibility and specific properties of MR imaging-guided adrenal biopsy using an open 0.2-T scanner and MR fluoroscopic fast imaging with steady-state free precession sequences. MR imaging-guided biopsy of the adrenal gland is feasible and safe. In all patients, appropriate specimens were obtained with full diagnostic yield and accuracy. MR fluoroscopy is particularly useful to establish an oblique paravertebral access without pleural transgression. For final needle placement, supplementary breath-hold multislice sequences are required in most cases.</description><subject>Adrenal Gland Neoplasms - diagnostic imaging</subject><subject>Adrenal Gland Neoplasms - pathology</subject><subject>Adrenals. Adrenal axis. Renin-angiotensin system (diseases)</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Biopsy - adverse effects</subject><subject>Biopsy - methods</subject><subject>Computer Systems</subject><subject>Endocrinopathies</subject><subject>Female</subject><subject>Fluoroscopy - adverse effects</subject><subject>Fluoroscopy - methods</subject><subject>Humans</subject><subject>Magnetic Resonance Imaging - adverse effects</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Male</subject><subject>Malignant tumors</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Postoperative Complications</subject><subject>Reproducibility of Results</subject><subject>Surgery, Computer-Assisted - methods</subject><subject>Time Factors</subject><issn>0361-803X</issn><issn>1546-3141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkE1r3DAQhkVISTZJf0AuQZc0J281ki1bxzR008CWQNJADwUhS_KugvwRaY3Zf18ta8hl5jDPvDM8CF0DWVIK-Xf1HpZQkSU_VCh4eYIWUOQ8Y5DDKVoQxiGrCPt7ji5ifCeElJUoz9A50JITQWGB_v1-wU-t2rhukz2OzliD702wnfL4h-uHuMdvMc2w6vDzYDu87qds5aw32esuYZvdFr9q1XU2JMTglLbyYx_6qPthf4W-NMpH-3Xul-ht9fPPw69s_fz49HC_zjQrxC6rc1Pr2nBogBkBSpfpTcttDrQpyooyTRUUgja1qIhiFoSgpaoE14wzRjS7RN-OuUPoP0Ybd7J1UVvvVWf7McqSUQG54AmEI6jThzHYRg7BtSrsJRB5UCqTUplkSi5npWnnZg4f69aaz43ZYQJuZ0BFrXwTVKdd_OTyKmeC0cTdHbmt22wnF6yMrfI-xYKcpmm-ejj5Hw2ai2s</recordid><startdate>20030601</startdate><enddate>20030601</enddate><creator>Konig, Claudius W</creator><creator>Pereira, Philippe L</creator><creator>Trubenbach, Jochen</creator><creator>Fritz, Jan</creator><creator>Duda, Stephan H</creator><creator>Schick, Fritz</creator><creator>Claussen, Claus D</creator><general>Am Roentgen Ray Soc</general><general>American Roentgen Ray Society</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20030601</creationdate><title>MR Imaging-Guided Adrenal Biopsy Using an Open Low-Field-Strength Scanner and MR Fluoroscopy</title><author>Konig, Claudius W ; Pereira, Philippe L ; Trubenbach, Jochen ; Fritz, Jan ; Duda, Stephan H ; Schick, Fritz ; Claussen, Claus D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c359t-b4dbcbd61f13d91ac7789e6e412f57823c2a1592fb980a3e19927a896c36330c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Adrenal Gland Neoplasms - diagnostic imaging</topic><topic>Adrenal Gland Neoplasms - pathology</topic><topic>Adrenals. Adrenal axis. Renin-angiotensin system (diseases)</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Biopsy - adverse effects</topic><topic>Biopsy - methods</topic><topic>Computer Systems</topic><topic>Endocrinopathies</topic><topic>Female</topic><topic>Fluoroscopy - adverse effects</topic><topic>Fluoroscopy - methods</topic><topic>Humans</topic><topic>Magnetic Resonance Imaging - adverse effects</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Male</topic><topic>Malignant tumors</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Postoperative Complications</topic><topic>Reproducibility of Results</topic><topic>Surgery, Computer-Assisted - methods</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Konig, Claudius W</creatorcontrib><creatorcontrib>Pereira, Philippe L</creatorcontrib><creatorcontrib>Trubenbach, Jochen</creatorcontrib><creatorcontrib>Fritz, Jan</creatorcontrib><creatorcontrib>Duda, Stephan H</creatorcontrib><creatorcontrib>Schick, Fritz</creatorcontrib><creatorcontrib>Claussen, Claus D</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of roentgenology (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Konig, Claudius W</au><au>Pereira, Philippe L</au><au>Trubenbach, Jochen</au><au>Fritz, Jan</au><au>Duda, Stephan H</au><au>Schick, Fritz</au><au>Claussen, Claus D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>MR Imaging-Guided Adrenal Biopsy Using an Open Low-Field-Strength Scanner and MR Fluoroscopy</atitle><jtitle>American journal of roentgenology (1976)</jtitle><addtitle>AJR Am J Roentgenol</addtitle><date>2003-06-01</date><risdate>2003</risdate><volume>180</volume><issue>6</issue><spage>1567</spage><epage>1570</epage><pages>1567-1570</pages><issn>0361-803X</issn><eissn>1546-3141</eissn><coden>AAJRDX</coden><abstract>The aim of our study was to test the feasibility and specific properties of MR imaging-guided adrenal biopsy using an open 0.2-T scanner and MR fluoroscopic fast imaging with steady-state free precession sequences. MR imaging-guided biopsy of the adrenal gland is feasible and safe. In all patients, appropriate specimens were obtained with full diagnostic yield and accuracy. MR fluoroscopy is particularly useful to establish an oblique paravertebral access without pleural transgression. For final needle placement, supplementary breath-hold multislice sequences are required in most cases.</abstract><cop>Leesburg, VA</cop><pub>Am Roentgen Ray Soc</pub><pmid>12760921</pmid><doi>10.2214/ajr.180.6.1801567</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0361-803X
ispartof American journal of roentgenology (1976), 2003-06, Vol.180 (6), p.1567-1570
issn 0361-803X
1546-3141
language eng
recordid cdi_proquest_miscellaneous_73291496
source American Roentgen Ray Society; MEDLINE; Alma/SFX Local Collection
subjects Adrenal Gland Neoplasms - diagnostic imaging
Adrenal Gland Neoplasms - pathology
Adrenals. Adrenal axis. Renin-angiotensin system (diseases)
Aged
Biological and medical sciences
Biopsy - adverse effects
Biopsy - methods
Computer Systems
Endocrinopathies
Female
Fluoroscopy - adverse effects
Fluoroscopy - methods
Humans
Magnetic Resonance Imaging - adverse effects
Magnetic Resonance Imaging - methods
Male
Malignant tumors
Medical sciences
Middle Aged
Postoperative Complications
Reproducibility of Results
Surgery, Computer-Assisted - methods
Time Factors
title MR Imaging-Guided Adrenal Biopsy Using an Open Low-Field-Strength Scanner and MR Fluoroscopy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T03%3A54%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=MR%20Imaging-Guided%20Adrenal%20Biopsy%20Using%20an%20Open%20Low-Field-Strength%20Scanner%20and%20MR%20Fluoroscopy&rft.jtitle=American%20journal%20of%20roentgenology%20(1976)&rft.au=Konig,%20Claudius%20W&rft.date=2003-06-01&rft.volume=180&rft.issue=6&rft.spage=1567&rft.epage=1570&rft.pages=1567-1570&rft.issn=0361-803X&rft.eissn=1546-3141&rft.coden=AAJRDX&rft_id=info:doi/10.2214/ajr.180.6.1801567&rft_dat=%3Cproquest_cross%3E73291496%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73291496&rft_id=info:pmid/12760921&rfr_iscdi=true