Determination of 4-n-nonylphenol in water by enzyme immunoassay

A range of monoclonal antibody-based competitive immunoassays in the format of microtitre plate ELISA and dipstick tests for quantitative and semi-quantitative detection of 4- n -nonylphenol in water was developed. A simple visual dipstick test was based on changing of spot colour from green to brow...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical and bioanalytical chemistry 2003-04, Vol.375 (8), p.1017-1019
Hauptverfasser: Samsonova, Jeanne V, Rubtsova, Maya Yu, Franek, Milan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1019
container_issue 8
container_start_page 1017
container_title Analytical and bioanalytical chemistry
container_volume 375
creator Samsonova, Jeanne V
Rubtsova, Maya Yu
Franek, Milan
description A range of monoclonal antibody-based competitive immunoassays in the format of microtitre plate ELISA and dipstick tests for quantitative and semi-quantitative detection of 4- n -nonylphenol in water was developed. A simple visual dipstick test was based on changing of spot colour from green to brown in the presence of 4- n -nonylphenol at concentrations within the range 10-100 ng mL(-1). Two different detection systems were used for quantitative immunoassay. Application of enhanced chemiluminescence (ECL) resulted in an increase of the sensitivity of ELISA when compared to conventional colorimetric detection. Thus a detection limit of 0.06 ng mL(-1 )of 4- n -nonylphenol was achieved with IC(50) 2.0 ng mL(-1). The tests developed were applied to natural and spiked water samples.
doi_str_mv 10.1007/s00216-003-1815-3
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73248178</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>18937744</sourcerecordid><originalsourceid>FETCH-LOGICAL-c328t-bfb88afba172e1ed936ead380c32d326d64537aedead01e8114bdf1293c86c463</originalsourceid><addsrcrecordid>eNqFkD1PwzAURT2AaCn8ABaUic3gZzu2MyFUPqVKLDBbTvIigmK7xIlQ-PWkaiVGpifdd-4dDiEXwK6BMX2TGOOgKGOCgoGciiOyBAWGciX5gpym9MkY5AbUCVkAV1oLWSzJ7T0O2Ps2uKGNIYtNJmmgIYap235giF3WhuzbzUxWThmGn8lj1no_huhSctMZOW5cl_D8cFfk_fHhbf1MN69PL-u7Da0ENwMtm9IY15QONEfAuhAKXS0Mm9-14KpWMhfaYT2nDNAAyLJugBeiMqqSSqzI1X5328evEdNgfZsq7DoXMI7JasGlAW3-BcEUQmspZxD2YNXHlHps7LZvvesnC8zulNq9UjsrtTulVsydy8P4WHqs_xoHn-IX0y9zxw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>18937744</pqid></control><display><type>article</type><title>Determination of 4-n-nonylphenol in water by enzyme immunoassay</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Samsonova, Jeanne V ; Rubtsova, Maya Yu ; Franek, Milan</creator><creatorcontrib>Samsonova, Jeanne V ; Rubtsova, Maya Yu ; Franek, Milan</creatorcontrib><description>A range of monoclonal antibody-based competitive immunoassays in the format of microtitre plate ELISA and dipstick tests for quantitative and semi-quantitative detection of 4- n -nonylphenol in water was developed. A simple visual dipstick test was based on changing of spot colour from green to brown in the presence of 4- n -nonylphenol at concentrations within the range 10-100 ng mL(-1). Two different detection systems were used for quantitative immunoassay. Application of enhanced chemiluminescence (ECL) resulted in an increase of the sensitivity of ELISA when compared to conventional colorimetric detection. Thus a detection limit of 0.06 ng mL(-1 )of 4- n -nonylphenol was achieved with IC(50) 2.0 ng mL(-1). The tests developed were applied to natural and spiked water samples.</description><identifier>ISSN: 1618-2642</identifier><identifier>DOI: 10.1007/s00216-003-1815-3</identifier><identifier>PMID: 12677349</identifier><language>eng</language><publisher>Germany</publisher><subject>4-n-nonylphenol ; Enzyme-Linked Immunosorbent Assay ; Immunoenzyme Techniques - methods ; Nylons ; Phenols - analysis ; Sensitivity and Specificity ; Water - chemistry</subject><ispartof>Analytical and bioanalytical chemistry, 2003-04, Vol.375 (8), p.1017-1019</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c328t-bfb88afba172e1ed936ead380c32d326d64537aedead01e8114bdf1293c86c463</citedby><cites>FETCH-LOGICAL-c328t-bfb88afba172e1ed936ead380c32d326d64537aedead01e8114bdf1293c86c463</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12677349$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Samsonova, Jeanne V</creatorcontrib><creatorcontrib>Rubtsova, Maya Yu</creatorcontrib><creatorcontrib>Franek, Milan</creatorcontrib><title>Determination of 4-n-nonylphenol in water by enzyme immunoassay</title><title>Analytical and bioanalytical chemistry</title><addtitle>Anal Bioanal Chem</addtitle><description>A range of monoclonal antibody-based competitive immunoassays in the format of microtitre plate ELISA and dipstick tests for quantitative and semi-quantitative detection of 4- n -nonylphenol in water was developed. A simple visual dipstick test was based on changing of spot colour from green to brown in the presence of 4- n -nonylphenol at concentrations within the range 10-100 ng mL(-1). Two different detection systems were used for quantitative immunoassay. Application of enhanced chemiluminescence (ECL) resulted in an increase of the sensitivity of ELISA when compared to conventional colorimetric detection. Thus a detection limit of 0.06 ng mL(-1 )of 4- n -nonylphenol was achieved with IC(50) 2.0 ng mL(-1). The tests developed were applied to natural and spiked water samples.</description><subject>4-n-nonylphenol</subject><subject>Enzyme-Linked Immunosorbent Assay</subject><subject>Immunoenzyme Techniques - methods</subject><subject>Nylons</subject><subject>Phenols - analysis</subject><subject>Sensitivity and Specificity</subject><subject>Water - chemistry</subject><issn>1618-2642</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkD1PwzAURT2AaCn8ABaUic3gZzu2MyFUPqVKLDBbTvIigmK7xIlQ-PWkaiVGpifdd-4dDiEXwK6BMX2TGOOgKGOCgoGciiOyBAWGciX5gpym9MkY5AbUCVkAV1oLWSzJ7T0O2Ps2uKGNIYtNJmmgIYap235giF3WhuzbzUxWThmGn8lj1no_huhSctMZOW5cl_D8cFfk_fHhbf1MN69PL-u7Da0ENwMtm9IY15QONEfAuhAKXS0Mm9-14KpWMhfaYT2nDNAAyLJugBeiMqqSSqzI1X5328evEdNgfZsq7DoXMI7JasGlAW3-BcEUQmspZxD2YNXHlHps7LZvvesnC8zulNq9UjsrtTulVsydy8P4WHqs_xoHn-IX0y9zxw</recordid><startdate>200304</startdate><enddate>200304</enddate><creator>Samsonova, Jeanne V</creator><creator>Rubtsova, Maya Yu</creator><creator>Franek, Milan</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>200304</creationdate><title>Determination of 4-n-nonylphenol in water by enzyme immunoassay</title><author>Samsonova, Jeanne V ; Rubtsova, Maya Yu ; Franek, Milan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c328t-bfb88afba172e1ed936ead380c32d326d64537aedead01e8114bdf1293c86c463</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>4-n-nonylphenol</topic><topic>Enzyme-Linked Immunosorbent Assay</topic><topic>Immunoenzyme Techniques - methods</topic><topic>Nylons</topic><topic>Phenols - analysis</topic><topic>Sensitivity and Specificity</topic><topic>Water - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Samsonova, Jeanne V</creatorcontrib><creatorcontrib>Rubtsova, Maya Yu</creatorcontrib><creatorcontrib>Franek, Milan</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical and bioanalytical chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Samsonova, Jeanne V</au><au>Rubtsova, Maya Yu</au><au>Franek, Milan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of 4-n-nonylphenol in water by enzyme immunoassay</atitle><jtitle>Analytical and bioanalytical chemistry</jtitle><addtitle>Anal Bioanal Chem</addtitle><date>2003-04</date><risdate>2003</risdate><volume>375</volume><issue>8</issue><spage>1017</spage><epage>1019</epage><pages>1017-1019</pages><issn>1618-2642</issn><abstract>A range of monoclonal antibody-based competitive immunoassays in the format of microtitre plate ELISA and dipstick tests for quantitative and semi-quantitative detection of 4- n -nonylphenol in water was developed. A simple visual dipstick test was based on changing of spot colour from green to brown in the presence of 4- n -nonylphenol at concentrations within the range 10-100 ng mL(-1). Two different detection systems were used for quantitative immunoassay. Application of enhanced chemiluminescence (ECL) resulted in an increase of the sensitivity of ELISA when compared to conventional colorimetric detection. Thus a detection limit of 0.06 ng mL(-1 )of 4- n -nonylphenol was achieved with IC(50) 2.0 ng mL(-1). The tests developed were applied to natural and spiked water samples.</abstract><cop>Germany</cop><pmid>12677349</pmid><doi>10.1007/s00216-003-1815-3</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1618-2642
ispartof Analytical and bioanalytical chemistry, 2003-04, Vol.375 (8), p.1017-1019
issn 1618-2642
language eng
recordid cdi_proquest_miscellaneous_73248178
source MEDLINE; SpringerLink Journals - AutoHoldings
subjects 4-n-nonylphenol
Enzyme-Linked Immunosorbent Assay
Immunoenzyme Techniques - methods
Nylons
Phenols - analysis
Sensitivity and Specificity
Water - chemistry
title Determination of 4-n-nonylphenol in water by enzyme immunoassay
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T16%3A55%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%204-n-nonylphenol%20in%20water%20by%20enzyme%20immunoassay&rft.jtitle=Analytical%20and%20bioanalytical%20chemistry&rft.au=Samsonova,%20Jeanne%20V&rft.date=2003-04&rft.volume=375&rft.issue=8&rft.spage=1017&rft.epage=1019&rft.pages=1017-1019&rft.issn=1618-2642&rft_id=info:doi/10.1007/s00216-003-1815-3&rft_dat=%3Cproquest_cross%3E18937744%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=18937744&rft_id=info:pmid/12677349&rfr_iscdi=true