Contrast injection around mandril wire of an accustick system using an extension tubing : technical note

We describe a technique for injecting contrast material around a mandril wire of an Accustick access system through the outer 6 French sheath of this system, thus identifying the position of the wire. This is accomplished by using an extension tubing.

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiovascular and interventional radiology 1992-07, Vol.15 (4), p.254-255
Hauptverfasser: MCKAY, R. H, TEITELBAUM, G. P, DAVIS, S, PENTECOST, M. J, GARNIC, D. J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 255
container_issue 4
container_start_page 254
container_title Cardiovascular and interventional radiology
container_volume 15
creator MCKAY, R. H
TEITELBAUM, G. P
DAVIS, S
PENTECOST, M. J
GARNIC, D. J
description We describe a technique for injecting contrast material around a mandril wire of an Accustick access system through the outer 6 French sheath of this system, thus identifying the position of the wire. This is accomplished by using an extension tubing.
doi_str_mv 10.1007/BF02733934
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_73215120</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73215120</sourcerecordid><originalsourceid>FETCH-LOGICAL-p235t-b15346e614fa8df42543ac2bc74d55973d576b50004dd3281ab5623fc90a02a03</originalsourceid><addsrcrecordid>eNo9kE1LxDAQhoMo67p68S7kIN6qk69-eNPFVWHBi4K3kiapm7VN1yRF99_bYvE0MM_zDsyL0DmBawKQ3dyvgGaMFYwfoDnhjCaQp--HaA4k4wkRghyjkxC2AETkVMzQjLCCs1TM0WbZuehliNi6rVHRdg5L3_VO41Y67W2Dv603uKuxHIhSfYhWfeKwD9G0uA_WfYzE_ETjwpiOfTXubnE0auOskg12XTSn6KiWTTBn01ygt9XD6_IpWb88Pi_v1smOMhGTigjGU5MSXstc15wKzqSilcq4FqLImBZZWgkA4FozmhNZiZSyWhUggUpgC3T1d3fnu6_ehFi2NijTNNKZrg9lxigRhI7ixST2VWt0ufO2lX5fTtUM_HLiMgxP1F46ZcO_NpQqaA7sFyz1ccE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73215120</pqid></control><display><type>article</type><title>Contrast injection around mandril wire of an accustick system using an extension tubing : technical note</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>MCKAY, R. H ; TEITELBAUM, G. P ; DAVIS, S ; PENTECOST, M. J ; GARNIC, D. J</creator><creatorcontrib>MCKAY, R. H ; TEITELBAUM, G. P ; DAVIS, S ; PENTECOST, M. J ; GARNIC, D. J</creatorcontrib><description>We describe a technique for injecting contrast material around a mandril wire of an Accustick access system through the outer 6 French sheath of this system, thus identifying the position of the wire. This is accomplished by using an extension tubing.</description><identifier>ISSN: 0174-1551</identifier><identifier>EISSN: 1432-086X</identifier><identifier>DOI: 10.1007/BF02733934</identifier><identifier>PMID: 1394365</identifier><identifier>CODEN: CAIRDG</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Biological and medical sciences ; Catheters, Indwelling ; Cholangiography - methods ; Contrast Media - administration &amp; dosage ; Drainage - instrumentation ; Humans ; Intubation - instrumentation ; Investigative techniques, diagnostic techniques (general aspects) ; Medical sciences ; Miscellaneous. Technology ; Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques ; Radiography, Interventional - methods ; Urography - methods</subject><ispartof>Cardiovascular and interventional radiology, 1992-07, Vol.15 (4), p.254-255</ispartof><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=5515280$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1394365$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>MCKAY, R. H</creatorcontrib><creatorcontrib>TEITELBAUM, G. P</creatorcontrib><creatorcontrib>DAVIS, S</creatorcontrib><creatorcontrib>PENTECOST, M. J</creatorcontrib><creatorcontrib>GARNIC, D. J</creatorcontrib><title>Contrast injection around mandril wire of an accustick system using an extension tubing : technical note</title><title>Cardiovascular and interventional radiology</title><addtitle>Cardiovasc Intervent Radiol</addtitle><description>We describe a technique for injecting contrast material around a mandril wire of an Accustick access system through the outer 6 French sheath of this system, thus identifying the position of the wire. This is accomplished by using an extension tubing.</description><subject>Biological and medical sciences</subject><subject>Catheters, Indwelling</subject><subject>Cholangiography - methods</subject><subject>Contrast Media - administration &amp; dosage</subject><subject>Drainage - instrumentation</subject><subject>Humans</subject><subject>Intubation - instrumentation</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Medical sciences</subject><subject>Miscellaneous. Technology</subject><subject>Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques</subject><subject>Radiography, Interventional - methods</subject><subject>Urography - methods</subject><issn>0174-1551</issn><issn>1432-086X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kE1LxDAQhoMo67p68S7kIN6qk69-eNPFVWHBi4K3kiapm7VN1yRF99_bYvE0MM_zDsyL0DmBawKQ3dyvgGaMFYwfoDnhjCaQp--HaA4k4wkRghyjkxC2AETkVMzQjLCCs1TM0WbZuehliNi6rVHRdg5L3_VO41Y67W2Dv603uKuxHIhSfYhWfeKwD9G0uA_WfYzE_ETjwpiOfTXubnE0auOskg12XTSn6KiWTTBn01ygt9XD6_IpWb88Pi_v1smOMhGTigjGU5MSXstc15wKzqSilcq4FqLImBZZWgkA4FozmhNZiZSyWhUggUpgC3T1d3fnu6_ehFi2NijTNNKZrg9lxigRhI7ixST2VWt0ufO2lX5fTtUM_HLiMgxP1F46ZcO_NpQqaA7sFyz1ccE</recordid><startdate>19920701</startdate><enddate>19920701</enddate><creator>MCKAY, R. H</creator><creator>TEITELBAUM, G. P</creator><creator>DAVIS, S</creator><creator>PENTECOST, M. J</creator><creator>GARNIC, D. J</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19920701</creationdate><title>Contrast injection around mandril wire of an accustick system using an extension tubing : technical note</title><author>MCKAY, R. H ; TEITELBAUM, G. P ; DAVIS, S ; PENTECOST, M. J ; GARNIC, D. J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p235t-b15346e614fa8df42543ac2bc74d55973d576b50004dd3281ab5623fc90a02a03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Biological and medical sciences</topic><topic>Catheters, Indwelling</topic><topic>Cholangiography - methods</topic><topic>Contrast Media - administration &amp; dosage</topic><topic>Drainage - instrumentation</topic><topic>Humans</topic><topic>Intubation - instrumentation</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Medical sciences</topic><topic>Miscellaneous. Technology</topic><topic>Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques</topic><topic>Radiography, Interventional - methods</topic><topic>Urography - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>MCKAY, R. H</creatorcontrib><creatorcontrib>TEITELBAUM, G. P</creatorcontrib><creatorcontrib>DAVIS, S</creatorcontrib><creatorcontrib>PENTECOST, M. J</creatorcontrib><creatorcontrib>GARNIC, D. J</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Cardiovascular and interventional radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MCKAY, R. H</au><au>TEITELBAUM, G. P</au><au>DAVIS, S</au><au>PENTECOST, M. J</au><au>GARNIC, D. J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Contrast injection around mandril wire of an accustick system using an extension tubing : technical note</atitle><jtitle>Cardiovascular and interventional radiology</jtitle><addtitle>Cardiovasc Intervent Radiol</addtitle><date>1992-07-01</date><risdate>1992</risdate><volume>15</volume><issue>4</issue><spage>254</spage><epage>255</epage><pages>254-255</pages><issn>0174-1551</issn><eissn>1432-086X</eissn><coden>CAIRDG</coden><abstract>We describe a technique for injecting contrast material around a mandril wire of an Accustick access system through the outer 6 French sheath of this system, thus identifying the position of the wire. This is accomplished by using an extension tubing.</abstract><cop>Heidelberg</cop><cop>Berlin</cop><pub>Springer</pub><pmid>1394365</pmid><doi>10.1007/BF02733934</doi><tpages>2</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0174-1551
ispartof Cardiovascular and interventional radiology, 1992-07, Vol.15 (4), p.254-255
issn 0174-1551
1432-086X
language eng
recordid cdi_proquest_miscellaneous_73215120
source MEDLINE; SpringerLink Journals - AutoHoldings
subjects Biological and medical sciences
Catheters, Indwelling
Cholangiography - methods
Contrast Media - administration & dosage
Drainage - instrumentation
Humans
Intubation - instrumentation
Investigative techniques, diagnostic techniques (general aspects)
Medical sciences
Miscellaneous. Technology
Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques
Radiography, Interventional - methods
Urography - methods
title Contrast injection around mandril wire of an accustick system using an extension tubing : technical note
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T03%3A19%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Contrast%20injection%20around%20mandril%20wire%20of%20an%20accustick%20system%20using%20an%20extension%20tubing%20:%20technical%20note&rft.jtitle=Cardiovascular%20and%20interventional%20radiology&rft.au=MCKAY,%20R.%20H&rft.date=1992-07-01&rft.volume=15&rft.issue=4&rft.spage=254&rft.epage=255&rft.pages=254-255&rft.issn=0174-1551&rft.eissn=1432-086X&rft.coden=CAIRDG&rft_id=info:doi/10.1007/BF02733934&rft_dat=%3Cproquest_pubme%3E73215120%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73215120&rft_id=info:pmid/1394365&rfr_iscdi=true