Diurnal Variation of Corneal Sensitivity and Thickness

PURPOSE.To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours. METHODS.A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cornea 2003-04, Vol.22 (3), p.205-209
Hauptverfasser: du Toit, Rènée, Vega, José A, Fonn, Desmond, Simpson, Trefford
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 209
container_issue 3
container_start_page 205
container_title Cornea
container_volume 22
creator du Toit, Rènée
Vega, José A
Fonn, Desmond
Simpson, Trefford
description PURPOSE.To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours. METHODS.A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measurements were performed at 22:00 before 8 hours of sleep and on the following day on eye opening and at hourly intervals between 7:00 and 22:00. RESULTS.Central corneal sensitivity varied by 35% over the 24 hours. Sensitivity was significantly lower by 17.1 ± 2.1% on eye opening and recovered to the level of the previous night after 4 hours. Corneal sensitivity continued to increase throughout the day but was not significantly higher. Central corneal thickness varied by 3.9% over the 24 hours. The mean overnight corneal swelling was 2.9 ± 0.31%, and 2 hours after eye opening, the cornea had deswelled to the same thickness as the previous night. The cornea thinned further throughout the day, but there were no statistically significant differences between the values after 14:00. There was a high correlation between corneal sensitivity and thickness over time (r = 0.8;p < 0.05). DISCUSSION.Corneal sensitivity correlated with corneal thicknessboth were higher on awakening and then decreased and remained below the levels measured the previous night. This may be due to physiological and/or environmental factors. The lack of significant differences between the values after 14:00 suggests that baseline may be measured at any time from 7 hours after eye opening.
doi_str_mv 10.1097/00003226-200304000-00004
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73137033</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73137033</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4224-4291b0db5aa84a686a5e3b64db208fb4e5cd2349ed0b3c584b85e659aa4114e13</originalsourceid><addsrcrecordid>eNp1kctOwzAQRS0EoqXwCygrdgG_7SxReUpILChsLTuZqKZpUuyEqn-PSwus8GbkqzMz0hmEMoIvCS7UFU6PUSpzmirm6ZdvI36AxkQwmXNV6EM0xlSpnCmOR-gkxvdEKCXpMRoRKoXGmo2RvPFDaG2Tvdngbe-7NuvqbNqFFlL4Am30vf_0_SazbZXN5r5ctBDjKTqqbRPhbF8n6PXudjZ9yJ-e7x-n1095ySnlOacFcbhywlrNrdTSCmBO8spRrGvHQZQVZbyACjtWCs2dFiBFYS0nhANhE3Sxm7sK3ccAsTdLH0toGttCN0SjGGEKM5ZAvQPL0MUYoDar4Jc2bAzBZuvM_Dgzv86-I55az_c7BreE6q9xLykBfAesu6aHEBfNsIZg5slQPzf_3YJ9AX0cdVg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73137033</pqid></control><display><type>article</type><title>Diurnal Variation of Corneal Sensitivity and Thickness</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>du Toit, Rènée ; Vega, José A ; Fonn, Desmond ; Simpson, Trefford</creator><creatorcontrib>du Toit, Rènée ; Vega, José A ; Fonn, Desmond ; Simpson, Trefford</creatorcontrib><description>PURPOSE.To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours. METHODS.A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measurements were performed at 22:00 before 8 hours of sleep and on the following day on eye opening and at hourly intervals between 7:00 and 22:00. RESULTS.Central corneal sensitivity varied by 35% over the 24 hours. Sensitivity was significantly lower by 17.1 ± 2.1% on eye opening and recovered to the level of the previous night after 4 hours. Corneal sensitivity continued to increase throughout the day but was not significantly higher. Central corneal thickness varied by 3.9% over the 24 hours. The mean overnight corneal swelling was 2.9 ± 0.31%, and 2 hours after eye opening, the cornea had deswelled to the same thickness as the previous night. The cornea thinned further throughout the day, but there were no statistically significant differences between the values after 14:00. There was a high correlation between corneal sensitivity and thickness over time (r = 0.8;p &lt; 0.05). DISCUSSION.Corneal sensitivity correlated with corneal thicknessboth were higher on awakening and then decreased and remained below the levels measured the previous night. This may be due to physiological and/or environmental factors. The lack of significant differences between the values after 14:00 suggests that baseline may be measured at any time from 7 hours after eye opening.</description><identifier>ISSN: 0277-3740</identifier><identifier>EISSN: 1536-4798</identifier><identifier>DOI: 10.1097/00003226-200304000-00004</identifier><identifier>PMID: 12658083</identifier><language>eng</language><publisher>United States: Lippincott Williams &amp; Wilkins, Inc</publisher><subject>Adult ; Body Weights and Measures ; Circadian Rhythm - physiology ; Cornea - anatomy &amp; histology ; Cornea - physiology ; Female ; Humans ; Male ; Sensation - physiology</subject><ispartof>Cornea, 2003-04, Vol.22 (3), p.205-209</ispartof><rights>2003 Lippincott Williams &amp; Wilkins, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4224-4291b0db5aa84a686a5e3b64db208fb4e5cd2349ed0b3c584b85e659aa4114e13</citedby><cites>FETCH-LOGICAL-c4224-4291b0db5aa84a686a5e3b64db208fb4e5cd2349ed0b3c584b85e659aa4114e13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12658083$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>du Toit, Rènée</creatorcontrib><creatorcontrib>Vega, José A</creatorcontrib><creatorcontrib>Fonn, Desmond</creatorcontrib><creatorcontrib>Simpson, Trefford</creatorcontrib><title>Diurnal Variation of Corneal Sensitivity and Thickness</title><title>Cornea</title><addtitle>Cornea</addtitle><description>PURPOSE.To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours. METHODS.A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measurements were performed at 22:00 before 8 hours of sleep and on the following day on eye opening and at hourly intervals between 7:00 and 22:00. RESULTS.Central corneal sensitivity varied by 35% over the 24 hours. Sensitivity was significantly lower by 17.1 ± 2.1% on eye opening and recovered to the level of the previous night after 4 hours. Corneal sensitivity continued to increase throughout the day but was not significantly higher. Central corneal thickness varied by 3.9% over the 24 hours. The mean overnight corneal swelling was 2.9 ± 0.31%, and 2 hours after eye opening, the cornea had deswelled to the same thickness as the previous night. The cornea thinned further throughout the day, but there were no statistically significant differences between the values after 14:00. There was a high correlation between corneal sensitivity and thickness over time (r = 0.8;p &lt; 0.05). DISCUSSION.Corneal sensitivity correlated with corneal thicknessboth were higher on awakening and then decreased and remained below the levels measured the previous night. This may be due to physiological and/or environmental factors. The lack of significant differences between the values after 14:00 suggests that baseline may be measured at any time from 7 hours after eye opening.</description><subject>Adult</subject><subject>Body Weights and Measures</subject><subject>Circadian Rhythm - physiology</subject><subject>Cornea - anatomy &amp; histology</subject><subject>Cornea - physiology</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Sensation - physiology</subject><issn>0277-3740</issn><issn>1536-4798</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kctOwzAQRS0EoqXwCygrdgG_7SxReUpILChsLTuZqKZpUuyEqn-PSwus8GbkqzMz0hmEMoIvCS7UFU6PUSpzmirm6ZdvI36AxkQwmXNV6EM0xlSpnCmOR-gkxvdEKCXpMRoRKoXGmo2RvPFDaG2Tvdngbe-7NuvqbNqFFlL4Am30vf_0_SazbZXN5r5ctBDjKTqqbRPhbF8n6PXudjZ9yJ-e7x-n1095ySnlOacFcbhywlrNrdTSCmBO8spRrGvHQZQVZbyACjtWCs2dFiBFYS0nhANhE3Sxm7sK3ccAsTdLH0toGttCN0SjGGEKM5ZAvQPL0MUYoDar4Jc2bAzBZuvM_Dgzv86-I55az_c7BreE6q9xLykBfAesu6aHEBfNsIZg5slQPzf_3YJ9AX0cdVg</recordid><startdate>200304</startdate><enddate>200304</enddate><creator>du Toit, Rènée</creator><creator>Vega, José A</creator><creator>Fonn, Desmond</creator><creator>Simpson, Trefford</creator><general>Lippincott Williams &amp; Wilkins, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200304</creationdate><title>Diurnal Variation of Corneal Sensitivity and Thickness</title><author>du Toit, Rènée ; Vega, José A ; Fonn, Desmond ; Simpson, Trefford</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4224-4291b0db5aa84a686a5e3b64db208fb4e5cd2349ed0b3c584b85e659aa4114e13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Adult</topic><topic>Body Weights and Measures</topic><topic>Circadian Rhythm - physiology</topic><topic>Cornea - anatomy &amp; histology</topic><topic>Cornea - physiology</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Sensation - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>du Toit, Rènée</creatorcontrib><creatorcontrib>Vega, José A</creatorcontrib><creatorcontrib>Fonn, Desmond</creatorcontrib><creatorcontrib>Simpson, Trefford</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Cornea</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>du Toit, Rènée</au><au>Vega, José A</au><au>Fonn, Desmond</au><au>Simpson, Trefford</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diurnal Variation of Corneal Sensitivity and Thickness</atitle><jtitle>Cornea</jtitle><addtitle>Cornea</addtitle><date>2003-04</date><risdate>2003</risdate><volume>22</volume><issue>3</issue><spage>205</spage><epage>209</epage><pages>205-209</pages><issn>0277-3740</issn><eissn>1536-4798</eissn><abstract>PURPOSE.To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours. METHODS.A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measurements were performed at 22:00 before 8 hours of sleep and on the following day on eye opening and at hourly intervals between 7:00 and 22:00. RESULTS.Central corneal sensitivity varied by 35% over the 24 hours. Sensitivity was significantly lower by 17.1 ± 2.1% on eye opening and recovered to the level of the previous night after 4 hours. Corneal sensitivity continued to increase throughout the day but was not significantly higher. Central corneal thickness varied by 3.9% over the 24 hours. The mean overnight corneal swelling was 2.9 ± 0.31%, and 2 hours after eye opening, the cornea had deswelled to the same thickness as the previous night. The cornea thinned further throughout the day, but there were no statistically significant differences between the values after 14:00. There was a high correlation between corneal sensitivity and thickness over time (r = 0.8;p &lt; 0.05). DISCUSSION.Corneal sensitivity correlated with corneal thicknessboth were higher on awakening and then decreased and remained below the levels measured the previous night. This may be due to physiological and/or environmental factors. The lack of significant differences between the values after 14:00 suggests that baseline may be measured at any time from 7 hours after eye opening.</abstract><cop>United States</cop><pub>Lippincott Williams &amp; Wilkins, Inc</pub><pmid>12658083</pmid><doi>10.1097/00003226-200304000-00004</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0277-3740
ispartof Cornea, 2003-04, Vol.22 (3), p.205-209
issn 0277-3740
1536-4798
language eng
recordid cdi_proquest_miscellaneous_73137033
source MEDLINE; Journals@Ovid Complete
subjects Adult
Body Weights and Measures
Circadian Rhythm - physiology
Cornea - anatomy & histology
Cornea - physiology
Female
Humans
Male
Sensation - physiology
title Diurnal Variation of Corneal Sensitivity and Thickness
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T23%3A27%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diurnal%20Variation%20of%20Corneal%20Sensitivity%20and%20Thickness&rft.jtitle=Cornea&rft.au=du%20Toit,%20R%C3%A8n%C3%A9e&rft.date=2003-04&rft.volume=22&rft.issue=3&rft.spage=205&rft.epage=209&rft.pages=205-209&rft.issn=0277-3740&rft.eissn=1536-4798&rft_id=info:doi/10.1097/00003226-200304000-00004&rft_dat=%3Cproquest_cross%3E73137033%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73137033&rft_id=info:pmid/12658083&rfr_iscdi=true