Three-dimensional reconstruction of the carpus and its vasculature: An anatomic study
Three-dimensional reconstructions of the carpus have been assembled from tomographic data of anatomic specimens after vascular injection with resin polymer of a density similar to that of bone. We have been able to produce three-dimensional reconstruction of the relationship between carpal bones and...
Gespeichert in:
Veröffentlicht in: | The Journal of hand surgery (American ed.) 1992-07, Vol.17 (4), p.767-772 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 772 |
---|---|
container_issue | 4 |
container_start_page | 767 |
container_title | The Journal of hand surgery (American ed.) |
container_volume | 17 |
creator | Oberlin, C. Salon, A. Pigeau, I. Sarcy, J.J. Guidici, P. Treil, N. |
description | Three-dimensional reconstructions of the carpus have been assembled from tomographic data of anatomic specimens after vascular injection with resin polymer of a density similar to that of bone. We have been able to produce three-dimensional reconstruction of the relationship between carpal bones and their vasculature. Fine tomographic slicing, on the order of 1 mm, has yielded sharp definition of bone structure, particularly of the entry points of nutrient vessels. The use of a very fluid synthetic resin has made possible the definition of vessels of fine caliber. A computerized program of three-dimensional reconstruction was used to obtain a series of views spaced at 10 to 20 degrees at predetermined right-angled axes. This has provided a precise matching of vessels with their corresponding points of bony penetration. This new method of imaging has enabled us to describe the entire vasculature of the bones of the carpus. The technique enjoys a number of advantages over conventional methods of study of carpal vasculature. In practice, the various known methods of arteriographic and digital angiographic examination do not have the same high definition and are unable to eliminate the effect of superimposition of views. In addition, the dissections are difficult and are likely to produce significant artifact. Corrosion techniques are elegant, but they are time-consuming, delicate procedures if selective isolation of bone and vasculature is required. |
doi_str_mv | 10.1016/0363-5023(92)90330-R |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73075722</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>036350239290330R</els_id><sourcerecordid>73075722</sourcerecordid><originalsourceid>FETCH-LOGICAL-c301t-8f198dc0717af7e7c1f6ff1dc020bfd0cfd4030d045e6e2b5506efffc111704f3</originalsourceid><addsrcrecordid>eNp9kF1LXDEQhoNU7Gr9By3kohR7cewkOUk8XhRE_IIFQfQ6ZJMJppyPbZIj7L9vtrvYu14NvPO8w_AQ8pnBOQOmfoBQopHAxVnHv3cgBDRPB2TBpGCNkqr9QBbvyEdynPMvgNoT8ogcMcU7qfiCvDy_JsTGxwHHHKfR9jShm8Zc0uxKDegUaHlF6mxaz5na0dNYMn2z2c29LXPCS3o11tyWaYiO5jL7zSdyGGyf8XQ_T8jL7c3z9X2zfLx7uL5aNk4AK81FYN2Fd6CZtkGjdiyoEFhNOKyCBxd8CwI8tBIV8pWUoDCE4BhjGtogTsi33d11mn7PmIsZYnbY93bEac5GC9BSc17Bdge6NOWcMJh1ioNNG8PAbG2arSqzVWU6bv7aNE-19mV_f14N6P-Vdvrq_ut-X3XYPiQ7upjfsfpvxzVU7OcOw-riLWIy2UUcHfpYZRfjp_j_P_4A1-aRpw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73075722</pqid></control><display><type>article</type><title>Three-dimensional reconstruction of the carpus and its vasculature: An anatomic study</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Oberlin, C. ; Salon, A. ; Pigeau, I. ; Sarcy, J.J. ; Guidici, P. ; Treil, N.</creator><creatorcontrib>Oberlin, C. ; Salon, A. ; Pigeau, I. ; Sarcy, J.J. ; Guidici, P. ; Treil, N.</creatorcontrib><description>Three-dimensional reconstructions of the carpus have been assembled from tomographic data of anatomic specimens after vascular injection with resin polymer of a density similar to that of bone. We have been able to produce three-dimensional reconstruction of the relationship between carpal bones and their vasculature. Fine tomographic slicing, on the order of 1 mm, has yielded sharp definition of bone structure, particularly of the entry points of nutrient vessels. The use of a very fluid synthetic resin has made possible the definition of vessels of fine caliber. A computerized program of three-dimensional reconstruction was used to obtain a series of views spaced at 10 to 20 degrees at predetermined right-angled axes. This has provided a precise matching of vessels with their corresponding points of bony penetration. This new method of imaging has enabled us to describe the entire vasculature of the bones of the carpus. The technique enjoys a number of advantages over conventional methods of study of carpal vasculature. In practice, the various known methods of arteriographic and digital angiographic examination do not have the same high definition and are unable to eliminate the effect of superimposition of views. In addition, the dissections are difficult and are likely to produce significant artifact. Corrosion techniques are elegant, but they are time-consuming, delicate procedures if selective isolation of bone and vasculature is required.</description><identifier>ISSN: 0363-5023</identifier><identifier>EISSN: 1531-6564</identifier><identifier>DOI: 10.1016/0363-5023(92)90330-R</identifier><identifier>PMID: 1629562</identifier><identifier>CODEN: JHSUDV</identifier><language>eng</language><publisher>New york, NY: Elsevier Inc</publisher><subject>Arteries - anatomy & histology ; Biological and medical sciences ; Carpal Bones - blood supply ; Carpal Bones - diagnostic imaging ; Fundamental and applied biological sciences. Psychology ; Humans ; Radiography ; Tomography ; Vertebrates: osteoarticular system, musculoskeletal system</subject><ispartof>The Journal of hand surgery (American ed.), 1992-07, Vol.17 (4), p.767-772</ispartof><rights>1992 American Society for Surgery of the Hand. All rights reserved</rights><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c301t-8f198dc0717af7e7c1f6ff1dc020bfd0cfd4030d045e6e2b5506efffc111704f3</citedby><cites>FETCH-LOGICAL-c301t-8f198dc0717af7e7c1f6ff1dc020bfd0cfd4030d045e6e2b5506efffc111704f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/0363-5023(92)90330-R$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,782,786,3552,27931,27932,46002</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=5509270$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1629562$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Oberlin, C.</creatorcontrib><creatorcontrib>Salon, A.</creatorcontrib><creatorcontrib>Pigeau, I.</creatorcontrib><creatorcontrib>Sarcy, J.J.</creatorcontrib><creatorcontrib>Guidici, P.</creatorcontrib><creatorcontrib>Treil, N.</creatorcontrib><title>Three-dimensional reconstruction of the carpus and its vasculature: An anatomic study</title><title>The Journal of hand surgery (American ed.)</title><addtitle>J Hand Surg Am</addtitle><description>Three-dimensional reconstructions of the carpus have been assembled from tomographic data of anatomic specimens after vascular injection with resin polymer of a density similar to that of bone. We have been able to produce three-dimensional reconstruction of the relationship between carpal bones and their vasculature. Fine tomographic slicing, on the order of 1 mm, has yielded sharp definition of bone structure, particularly of the entry points of nutrient vessels. The use of a very fluid synthetic resin has made possible the definition of vessels of fine caliber. A computerized program of three-dimensional reconstruction was used to obtain a series of views spaced at 10 to 20 degrees at predetermined right-angled axes. This has provided a precise matching of vessels with their corresponding points of bony penetration. This new method of imaging has enabled us to describe the entire vasculature of the bones of the carpus. The technique enjoys a number of advantages over conventional methods of study of carpal vasculature. In practice, the various known methods of arteriographic and digital angiographic examination do not have the same high definition and are unable to eliminate the effect of superimposition of views. In addition, the dissections are difficult and are likely to produce significant artifact. Corrosion techniques are elegant, but they are time-consuming, delicate procedures if selective isolation of bone and vasculature is required.</description><subject>Arteries - anatomy & histology</subject><subject>Biological and medical sciences</subject><subject>Carpal Bones - blood supply</subject><subject>Carpal Bones - diagnostic imaging</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Humans</subject><subject>Radiography</subject><subject>Tomography</subject><subject>Vertebrates: osteoarticular system, musculoskeletal system</subject><issn>0363-5023</issn><issn>1531-6564</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kF1LXDEQhoNU7Gr9By3kohR7cewkOUk8XhRE_IIFQfQ6ZJMJppyPbZIj7L9vtrvYu14NvPO8w_AQ8pnBOQOmfoBQopHAxVnHv3cgBDRPB2TBpGCNkqr9QBbvyEdynPMvgNoT8ogcMcU7qfiCvDy_JsTGxwHHHKfR9jShm8Zc0uxKDegUaHlF6mxaz5na0dNYMn2z2c29LXPCS3o11tyWaYiO5jL7zSdyGGyf8XQ_T8jL7c3z9X2zfLx7uL5aNk4AK81FYN2Fd6CZtkGjdiyoEFhNOKyCBxd8CwI8tBIV8pWUoDCE4BhjGtogTsi33d11mn7PmIsZYnbY93bEac5GC9BSc17Bdge6NOWcMJh1ioNNG8PAbG2arSqzVWU6bv7aNE-19mV_f14N6P-Vdvrq_ut-X3XYPiQ7upjfsfpvxzVU7OcOw-riLWIy2UUcHfpYZRfjp_j_P_4A1-aRpw</recordid><startdate>199207</startdate><enddate>199207</enddate><creator>Oberlin, C.</creator><creator>Salon, A.</creator><creator>Pigeau, I.</creator><creator>Sarcy, J.J.</creator><creator>Guidici, P.</creator><creator>Treil, N.</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199207</creationdate><title>Three-dimensional reconstruction of the carpus and its vasculature: An anatomic study</title><author>Oberlin, C. ; Salon, A. ; Pigeau, I. ; Sarcy, J.J. ; Guidici, P. ; Treil, N.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c301t-8f198dc0717af7e7c1f6ff1dc020bfd0cfd4030d045e6e2b5506efffc111704f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Arteries - anatomy & histology</topic><topic>Biological and medical sciences</topic><topic>Carpal Bones - blood supply</topic><topic>Carpal Bones - diagnostic imaging</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Humans</topic><topic>Radiography</topic><topic>Tomography</topic><topic>Vertebrates: osteoarticular system, musculoskeletal system</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Oberlin, C.</creatorcontrib><creatorcontrib>Salon, A.</creatorcontrib><creatorcontrib>Pigeau, I.</creatorcontrib><creatorcontrib>Sarcy, J.J.</creatorcontrib><creatorcontrib>Guidici, P.</creatorcontrib><creatorcontrib>Treil, N.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of hand surgery (American ed.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Oberlin, C.</au><au>Salon, A.</au><au>Pigeau, I.</au><au>Sarcy, J.J.</au><au>Guidici, P.</au><au>Treil, N.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Three-dimensional reconstruction of the carpus and its vasculature: An anatomic study</atitle><jtitle>The Journal of hand surgery (American ed.)</jtitle><addtitle>J Hand Surg Am</addtitle><date>1992-07</date><risdate>1992</risdate><volume>17</volume><issue>4</issue><spage>767</spage><epage>772</epage><pages>767-772</pages><issn>0363-5023</issn><eissn>1531-6564</eissn><coden>JHSUDV</coden><abstract>Three-dimensional reconstructions of the carpus have been assembled from tomographic data of anatomic specimens after vascular injection with resin polymer of a density similar to that of bone. We have been able to produce three-dimensional reconstruction of the relationship between carpal bones and their vasculature. Fine tomographic slicing, on the order of 1 mm, has yielded sharp definition of bone structure, particularly of the entry points of nutrient vessels. The use of a very fluid synthetic resin has made possible the definition of vessels of fine caliber. A computerized program of three-dimensional reconstruction was used to obtain a series of views spaced at 10 to 20 degrees at predetermined right-angled axes. This has provided a precise matching of vessels with their corresponding points of bony penetration. This new method of imaging has enabled us to describe the entire vasculature of the bones of the carpus. The technique enjoys a number of advantages over conventional methods of study of carpal vasculature. In practice, the various known methods of arteriographic and digital angiographic examination do not have the same high definition and are unable to eliminate the effect of superimposition of views. In addition, the dissections are difficult and are likely to produce significant artifact. Corrosion techniques are elegant, but they are time-consuming, delicate procedures if selective isolation of bone and vasculature is required.</abstract><cop>New york, NY</cop><pub>Elsevier Inc</pub><pmid>1629562</pmid><doi>10.1016/0363-5023(92)90330-R</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0363-5023 |
ispartof | The Journal of hand surgery (American ed.), 1992-07, Vol.17 (4), p.767-772 |
issn | 0363-5023 1531-6564 |
language | eng |
recordid | cdi_proquest_miscellaneous_73075722 |
source | MEDLINE; Elsevier ScienceDirect Journals Complete |
subjects | Arteries - anatomy & histology Biological and medical sciences Carpal Bones - blood supply Carpal Bones - diagnostic imaging Fundamental and applied biological sciences. Psychology Humans Radiography Tomography Vertebrates: osteoarticular system, musculoskeletal system |
title | Three-dimensional reconstruction of the carpus and its vasculature: An anatomic study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-05T07%3A28%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Three-dimensional%20reconstruction%20of%20the%20carpus%20and%20its%20vasculature:%20An%20anatomic%20study&rft.jtitle=The%20Journal%20of%20hand%20surgery%20(American%20ed.)&rft.au=Oberlin,%20C.&rft.date=1992-07&rft.volume=17&rft.issue=4&rft.spage=767&rft.epage=772&rft.pages=767-772&rft.issn=0363-5023&rft.eissn=1531-6564&rft.coden=JHSUDV&rft_id=info:doi/10.1016/0363-5023(92)90330-R&rft_dat=%3Cproquest_cross%3E73075722%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73075722&rft_id=info:pmid/1629562&rft_els_id=036350239290330R&rfr_iscdi=true |