A comparison of a left-sided Broncho-Cath® with the torque control blocker univent and the wire-guided blocker
Lung isolation can be accomplished in two ways: the first, a double-lumen endotracheal tube (DLT) and the second, a bronchial blocker (Univent or Arndt blocker). Previous studies have found that the DLT and the Univent are comparable when providing lung isolation. A new bronchial blocker, the wire-g...
Gespeichert in:
Veröffentlicht in: | Anesthesia and analgesia 2003, Vol.96 (1), p.283-289 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 289 |
---|---|
container_issue | 1 |
container_start_page | 283 |
container_title | Anesthesia and analgesia |
container_volume | 96 |
creator | CAMPOS, Javier H KERNSTINE, Kemp H |
description | Lung isolation can be accomplished in two ways: the first, a double-lumen endotracheal tube (DLT) and the second, a bronchial blocker (Univent or Arndt blocker). Previous studies have found that the DLT and the Univent are comparable when providing lung isolation. A new bronchial blocker, the wire-guided endobronchial blocker (Arndt blocker), has been introduced. However, there is no study to report its effectiveness with lung isolation during elective thoracic surgical cases. Therefore, we designed a prospective, randomized trial to compare the effectiveness of lung isolation among the 3 endotracheal tubes: the left-sided DLT Broncho-Cath Group A (n = 16 patients), the torque control blocker Univent Group B (n = 16 patients), and the wire-guided Arndt blocker Group C (n = 32 patients). The following variables were recorded: 1) time to initially position the assigned tube, 2) frequency of malpositions, 3) frequency of use of fiberoptic bronchoscope, 4) overall surgical exposure, and 5) tube acquisition cost. The Arndt blocker took longer to place (3:34 min/s) compared with the other 2 groups: the DLT group (2:08 min/s) or the Univent group (2:38 min/s) (P < 0.0004). There was no statistical difference in tube malpositions among the three groups: two for the DLT group, four for the Univent group, and nine in the Arndt group. Excluding the time for tube placement, the Arndt group also took longer for the lung to collapse (26:02 min/s), compared with the DLT group (17:54 min/s) or Univent group (19:28 min/s) (P < 0.0060). Furthermore, unlike the other two groups, the majority of the Arndt patients required suction to achieve lung collapse. Once lung isolation was achieved, overall surgical exposure was rated excellent for the three groups. Acquisition cost for the DLT group was $1663.20 (21 tubes opened), $2329.00 for the Univent group (17 tubes opened), and $3567.00 for the Arndt group (33 wire-guided blockers opened). This study demonstrates that the Arndt blocker takes longer to position and longer to deflate the isolated lung. For elective thoracic surgical cases, once the lung was isolated, the management seemed to be similar for all three tube groups.
We compared the latest design of double-lumen tubes Broncho-Cath, Univent, and Arndt blockers during lung isolation. Our results show that the Arndt blocker takes longer to position and longer to deflate the isolated lung. Once the lung was isolated, the management seemed to be similar for all three device |
doi_str_mv | 10.1097/00000539-200301000-00056 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72935758</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72935758</sourcerecordid><originalsourceid>FETCH-LOGICAL-c391t-62467f88f65eca4a4843db6724c781df8198dcb5bea201390547c938dcc684503</originalsourceid><addsrcrecordid>eNpFkMtOwzAQRS0EgvL4BeQN7Ax-xK9lqXhJSGxgHTmOQwNpXGyHip_iI_gy3DbAbEZzde6MfQGABF8QrOUlXhdnGlGMGSZ5QGtB7IAJ4VQgybXaBZOsMUS11gfgMMbXPBKsxD44IJRjroWcAD-F1i-WJrTR99A30MDONQnFtnY1vAq-t3OPZibNv7_gqk1zmOYOJh_eB5edfQq-g1Xn7ZsLcOjbD9cnaPp6g63a4NDLsFk1MsdgrzFddCdjPwLPN9dPszv08Hh7P5s-IMs0SUjQQshGqUZwZ01hClWwuhKSFlYqUjeKaFXbilfOUEyYxryQVrOsWaEKjtkRON_uXQafnxpTuWijdV1neueHWEqqGZdcZVBtQRt8jME15TK0CxM-S4LLddjlb9jlX9jlJuxsPR1vDNXC1f_GMd0MnI2AidZ0TTC9beM_V-RPKkzZD-vih80</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72935758</pqid></control><display><type>article</type><title>A comparison of a left-sided Broncho-Cath® with the torque control blocker univent and the wire-guided blocker</title><source>Journals@OVID</source><source>MEDLINE</source><source>EZB Electronic Journals Library</source><source>Journals@Ovid Complete</source><creator>CAMPOS, Javier H ; KERNSTINE, Kemp H</creator><creatorcontrib>CAMPOS, Javier H ; KERNSTINE, Kemp H</creatorcontrib><description>Lung isolation can be accomplished in two ways: the first, a double-lumen endotracheal tube (DLT) and the second, a bronchial blocker (Univent or Arndt blocker). Previous studies have found that the DLT and the Univent are comparable when providing lung isolation. A new bronchial blocker, the wire-guided endobronchial blocker (Arndt blocker), has been introduced. However, there is no study to report its effectiveness with lung isolation during elective thoracic surgical cases. Therefore, we designed a prospective, randomized trial to compare the effectiveness of lung isolation among the 3 endotracheal tubes: the left-sided DLT Broncho-Cath Group A (n = 16 patients), the torque control blocker Univent Group B (n = 16 patients), and the wire-guided Arndt blocker Group C (n = 32 patients). The following variables were recorded: 1) time to initially position the assigned tube, 2) frequency of malpositions, 3) frequency of use of fiberoptic bronchoscope, 4) overall surgical exposure, and 5) tube acquisition cost. The Arndt blocker took longer to place (3:34 min/s) compared with the other 2 groups: the DLT group (2:08 min/s) or the Univent group (2:38 min/s) (P < 0.0004). There was no statistical difference in tube malpositions among the three groups: two for the DLT group, four for the Univent group, and nine in the Arndt group. Excluding the time for tube placement, the Arndt group also took longer for the lung to collapse (26:02 min/s), compared with the DLT group (17:54 min/s) or Univent group (19:28 min/s) (P < 0.0060). Furthermore, unlike the other two groups, the majority of the Arndt patients required suction to achieve lung collapse. Once lung isolation was achieved, overall surgical exposure was rated excellent for the three groups. Acquisition cost for the DLT group was $1663.20 (21 tubes opened), $2329.00 for the Univent group (17 tubes opened), and $3567.00 for the Arndt group (33 wire-guided blockers opened). This study demonstrates that the Arndt blocker takes longer to position and longer to deflate the isolated lung. For elective thoracic surgical cases, once the lung was isolated, the management seemed to be similar for all three tube groups.
We compared the latest design of double-lumen tubes Broncho-Cath, Univent, and Arndt blockers during lung isolation. Our results show that the Arndt blocker takes longer to position and longer to deflate the isolated lung. Once the lung was isolated, the management seemed to be similar for all three devices.</description><identifier>ISSN: 0003-2999</identifier><identifier>EISSN: 1526-7598</identifier><identifier>DOI: 10.1097/00000539-200301000-00056</identifier><identifier>PMID: 12505967</identifier><identifier>CODEN: AACRAT</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott</publisher><subject>Adult ; Aged ; Aged, 80 and over ; Anesthesia ; Anesthesia depending on type of surgery ; Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Biological and medical sciences ; Bronchoscopy ; Costs and Cost Analysis ; Elective Surgical Procedures ; Female ; Fiber Optic Technology ; Humans ; Intubation, Intratracheal - economics ; Intubation, Intratracheal - instrumentation ; Laryngoscopy ; Male ; Medical sciences ; Middle Aged ; Respiration, Artificial - methods ; Thoracic and cardiovascular surgery. Cardiopulmonary bypass ; Thoracic Surgical Procedures - methods</subject><ispartof>Anesthesia and analgesia, 2003, Vol.96 (1), p.283-289</ispartof><rights>2003 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c391t-62467f88f65eca4a4843db6724c781df8198dcb5bea201390547c938dcc684503</citedby><cites>FETCH-LOGICAL-c391t-62467f88f65eca4a4843db6724c781df8198dcb5bea201390547c938dcc684503</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27900,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=14467802$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12505967$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>CAMPOS, Javier H</creatorcontrib><creatorcontrib>KERNSTINE, Kemp H</creatorcontrib><title>A comparison of a left-sided Broncho-Cath® with the torque control blocker univent and the wire-guided blocker</title><title>Anesthesia and analgesia</title><addtitle>Anesth Analg</addtitle><description>Lung isolation can be accomplished in two ways: the first, a double-lumen endotracheal tube (DLT) and the second, a bronchial blocker (Univent or Arndt blocker). Previous studies have found that the DLT and the Univent are comparable when providing lung isolation. A new bronchial blocker, the wire-guided endobronchial blocker (Arndt blocker), has been introduced. However, there is no study to report its effectiveness with lung isolation during elective thoracic surgical cases. Therefore, we designed a prospective, randomized trial to compare the effectiveness of lung isolation among the 3 endotracheal tubes: the left-sided DLT Broncho-Cath Group A (n = 16 patients), the torque control blocker Univent Group B (n = 16 patients), and the wire-guided Arndt blocker Group C (n = 32 patients). The following variables were recorded: 1) time to initially position the assigned tube, 2) frequency of malpositions, 3) frequency of use of fiberoptic bronchoscope, 4) overall surgical exposure, and 5) tube acquisition cost. The Arndt blocker took longer to place (3:34 min/s) compared with the other 2 groups: the DLT group (2:08 min/s) or the Univent group (2:38 min/s) (P < 0.0004). There was no statistical difference in tube malpositions among the three groups: two for the DLT group, four for the Univent group, and nine in the Arndt group. Excluding the time for tube placement, the Arndt group also took longer for the lung to collapse (26:02 min/s), compared with the DLT group (17:54 min/s) or Univent group (19:28 min/s) (P < 0.0060). Furthermore, unlike the other two groups, the majority of the Arndt patients required suction to achieve lung collapse. Once lung isolation was achieved, overall surgical exposure was rated excellent for the three groups. Acquisition cost for the DLT group was $1663.20 (21 tubes opened), $2329.00 for the Univent group (17 tubes opened), and $3567.00 for the Arndt group (33 wire-guided blockers opened). This study demonstrates that the Arndt blocker takes longer to position and longer to deflate the isolated lung. For elective thoracic surgical cases, once the lung was isolated, the management seemed to be similar for all three tube groups.
We compared the latest design of double-lumen tubes Broncho-Cath, Univent, and Arndt blockers during lung isolation. Our results show that the Arndt blocker takes longer to position and longer to deflate the isolated lung. Once the lung was isolated, the management seemed to be similar for all three devices.</description><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Anesthesia</subject><subject>Anesthesia depending on type of surgery</subject><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Biological and medical sciences</subject><subject>Bronchoscopy</subject><subject>Costs and Cost Analysis</subject><subject>Elective Surgical Procedures</subject><subject>Female</subject><subject>Fiber Optic Technology</subject><subject>Humans</subject><subject>Intubation, Intratracheal - economics</subject><subject>Intubation, Intratracheal - instrumentation</subject><subject>Laryngoscopy</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Respiration, Artificial - methods</subject><subject>Thoracic and cardiovascular surgery. Cardiopulmonary bypass</subject><subject>Thoracic Surgical Procedures - methods</subject><issn>0003-2999</issn><issn>1526-7598</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkMtOwzAQRS0EgvL4BeQN7Ax-xK9lqXhJSGxgHTmOQwNpXGyHip_iI_gy3DbAbEZzde6MfQGABF8QrOUlXhdnGlGMGSZ5QGtB7IAJ4VQgybXaBZOsMUS11gfgMMbXPBKsxD44IJRjroWcAD-F1i-WJrTR99A30MDONQnFtnY1vAq-t3OPZibNv7_gqk1zmOYOJh_eB5edfQq-g1Xn7ZsLcOjbD9cnaPp6g63a4NDLsFk1MsdgrzFddCdjPwLPN9dPszv08Hh7P5s-IMs0SUjQQshGqUZwZ01hClWwuhKSFlYqUjeKaFXbilfOUEyYxryQVrOsWaEKjtkRON_uXQafnxpTuWijdV1neueHWEqqGZdcZVBtQRt8jME15TK0CxM-S4LLddjlb9jlX9jlJuxsPR1vDNXC1f_GMd0MnI2AidZ0TTC9beM_V-RPKkzZD-vih80</recordid><startdate>2003</startdate><enddate>2003</enddate><creator>CAMPOS, Javier H</creator><creator>KERNSTINE, Kemp H</creator><general>Lippincott</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>2003</creationdate><title>A comparison of a left-sided Broncho-Cath® with the torque control blocker univent and the wire-guided blocker</title><author>CAMPOS, Javier H ; KERNSTINE, Kemp H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c391t-62467f88f65eca4a4843db6724c781df8198dcb5bea201390547c938dcc684503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Anesthesia</topic><topic>Anesthesia depending on type of surgery</topic><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Biological and medical sciences</topic><topic>Bronchoscopy</topic><topic>Costs and Cost Analysis</topic><topic>Elective Surgical Procedures</topic><topic>Female</topic><topic>Fiber Optic Technology</topic><topic>Humans</topic><topic>Intubation, Intratracheal - economics</topic><topic>Intubation, Intratracheal - instrumentation</topic><topic>Laryngoscopy</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Respiration, Artificial - methods</topic><topic>Thoracic and cardiovascular surgery. Cardiopulmonary bypass</topic><topic>Thoracic Surgical Procedures - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>CAMPOS, Javier H</creatorcontrib><creatorcontrib>KERNSTINE, Kemp H</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Anesthesia and analgesia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>CAMPOS, Javier H</au><au>KERNSTINE, Kemp H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A comparison of a left-sided Broncho-Cath® with the torque control blocker univent and the wire-guided blocker</atitle><jtitle>Anesthesia and analgesia</jtitle><addtitle>Anesth Analg</addtitle><date>2003</date><risdate>2003</risdate><volume>96</volume><issue>1</issue><spage>283</spage><epage>289</epage><pages>283-289</pages><issn>0003-2999</issn><eissn>1526-7598</eissn><coden>AACRAT</coden><abstract>Lung isolation can be accomplished in two ways: the first, a double-lumen endotracheal tube (DLT) and the second, a bronchial blocker (Univent or Arndt blocker). Previous studies have found that the DLT and the Univent are comparable when providing lung isolation. A new bronchial blocker, the wire-guided endobronchial blocker (Arndt blocker), has been introduced. However, there is no study to report its effectiveness with lung isolation during elective thoracic surgical cases. Therefore, we designed a prospective, randomized trial to compare the effectiveness of lung isolation among the 3 endotracheal tubes: the left-sided DLT Broncho-Cath Group A (n = 16 patients), the torque control blocker Univent Group B (n = 16 patients), and the wire-guided Arndt blocker Group C (n = 32 patients). The following variables were recorded: 1) time to initially position the assigned tube, 2) frequency of malpositions, 3) frequency of use of fiberoptic bronchoscope, 4) overall surgical exposure, and 5) tube acquisition cost. The Arndt blocker took longer to place (3:34 min/s) compared with the other 2 groups: the DLT group (2:08 min/s) or the Univent group (2:38 min/s) (P < 0.0004). There was no statistical difference in tube malpositions among the three groups: two for the DLT group, four for the Univent group, and nine in the Arndt group. Excluding the time for tube placement, the Arndt group also took longer for the lung to collapse (26:02 min/s), compared with the DLT group (17:54 min/s) or Univent group (19:28 min/s) (P < 0.0060). Furthermore, unlike the other two groups, the majority of the Arndt patients required suction to achieve lung collapse. Once lung isolation was achieved, overall surgical exposure was rated excellent for the three groups. Acquisition cost for the DLT group was $1663.20 (21 tubes opened), $2329.00 for the Univent group (17 tubes opened), and $3567.00 for the Arndt group (33 wire-guided blockers opened). This study demonstrates that the Arndt blocker takes longer to position and longer to deflate the isolated lung. For elective thoracic surgical cases, once the lung was isolated, the management seemed to be similar for all three tube groups.
We compared the latest design of double-lumen tubes Broncho-Cath, Univent, and Arndt blockers during lung isolation. Our results show that the Arndt blocker takes longer to position and longer to deflate the isolated lung. Once the lung was isolated, the management seemed to be similar for all three devices.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott</pub><pmid>12505967</pmid><doi>10.1097/00000539-200301000-00056</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2999 |
ispartof | Anesthesia and analgesia, 2003, Vol.96 (1), p.283-289 |
issn | 0003-2999 1526-7598 |
language | eng |
recordid | cdi_proquest_miscellaneous_72935758 |
source | Journals@OVID; MEDLINE; EZB Electronic Journals Library; Journals@Ovid Complete |
subjects | Adult Aged Aged, 80 and over Anesthesia Anesthesia depending on type of surgery Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy Biological and medical sciences Bronchoscopy Costs and Cost Analysis Elective Surgical Procedures Female Fiber Optic Technology Humans Intubation, Intratracheal - economics Intubation, Intratracheal - instrumentation Laryngoscopy Male Medical sciences Middle Aged Respiration, Artificial - methods Thoracic and cardiovascular surgery. Cardiopulmonary bypass Thoracic Surgical Procedures - methods |
title | A comparison of a left-sided Broncho-Cath® with the torque control blocker univent and the wire-guided blocker |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T21%3A44%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20comparison%20of%20a%20left-sided%20Broncho-Cath%C2%AE%20with%20the%20torque%20control%20blocker%20univent%20and%20the%20wire-guided%20blocker&rft.jtitle=Anesthesia%20and%20analgesia&rft.au=CAMPOS,%20Javier%20H&rft.date=2003&rft.volume=96&rft.issue=1&rft.spage=283&rft.epage=289&rft.pages=283-289&rft.issn=0003-2999&rft.eissn=1526-7598&rft.coden=AACRAT&rft_id=info:doi/10.1097/00000539-200301000-00056&rft_dat=%3Cproquest_cross%3E72935758%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72935758&rft_id=info:pmid/12505967&rfr_iscdi=true |