Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series

A variety of techniques may be used to achieve fixation of the upper cervical spine. Transarticular atlantoaxial screws, posterior interspinous cable and graft constructs, and interlaminar clamps have been used effectively to achieve atlantoaxial fixation. Various anatomical factors, however, may pr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Neurosurgical focus 2002-01, Vol.12 (1), p.E5-E5
Hauptverfasser: Fiore, Amory J, Haid, Regis W, Rodts, Gerald E, Subach, Brian R, Mummaneni, Praveen V, Riedel, Charles J, Birch, Barry D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page E5
container_issue 1
container_start_page E5
container_title Neurosurgical focus
container_volume 12
creator Fiore, Amory J
Haid, Regis W
Rodts, Gerald E
Subach, Brian R
Mummaneni, Praveen V
Riedel, Charles J
Birch, Barry D
description A variety of techniques may be used to achieve fixation of the upper cervical spine. Transarticular atlantoaxial screws, posterior interspinous cable and graft constructs, and interlaminar clamps have been used effectively to achieve atlantoaxial fixation. Various anatomical factors, however, may preclude the successful application of these techniques. These factors include aberrant vertebral artery anatomy, irreducible atlantoaxial subluxation, exaggerated cervicothoracic kyphosis, and the absence of the osseous substrate for fixation. In these cases, an alternative method of fixation must be performed. The authors present an alternative method to achieve fixation of the atlas in which lateral mass screws can be applied to atlantoaxial and occipitocervical fixation. Between February 1998 and November 2001, eight patients who ranged in age from 16 to 74 years underwent posterior fixation for upper cervical instability. Diagnoses included C-2 metastastic disease in two patients, irreducible odontoid fractures in two patients, atlantoaxial subluxation in two patients, and transverse ligament synovial cyst in two patients. Various anatomical factors precluded transarticular atlantoaxial screw fixation in seven patients. One patient with a highly unstable spine due to a C-2 metastasis and pathological fracture underwent occipitocervical fusion. Atlantocervical fixation was achieved in seven patients by using varying constructs incorporating C-1 lateral mass screws. Occipitocervical fixation was achieved in one patient by incorporating C-1 lateral mass screws as an additional fixation point. A total of 14 C-1 lateral mass screws were placed in eight patients. There were no intraoperative complications. In all patients rigid fixation was achieved as demonstrated on postoperative radiographs. One patient died on postoperative Day 9 of aspiration pneumonia. At a mean follow-up time of 7.4 months, rigid fixation was maintained in all patients. Atlantal lateral mass screws can be used to provide a safe and efficacious means of achieving atlantoaxial fixation when anatomical constraints preclude the use of a more traditional procedure. Atlantal lateral mass screws may also be incorporated in occipitocervical constructs to provide additional fixation points which may prevent construct failure.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_72928046</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72928046</sourcerecordid><originalsourceid>FETCH-LOGICAL-p124t-c21f60887307bfa83db4c7945cc6406947b6bd88af52cdfcfa24f5be6fa798d33</originalsourceid><addsrcrecordid>eNo1kE9LxDAUxIMg7rr6FSQnb4U0SZPU27L4Dxa86LmmrwlW2qTmpYjf3oDraQbmNw_enJFtzVpeMWXkhlwifjImeKObC7KpFa-5EHxL3vd5siHbiU42u1R0togUIblvpD4mukQswVgcLmMoQHIQA-a0Qh5juKPZwUcYoSQhZkdtGChYdBRLy-EVOfd2Qnd90h15e7h_PTxVx5fH58P-WC01l7kCXnvFjNGC6d5bI4Zegm5lA6AkU63UveoHY6xvOAwevOXSN71T3urWDELsyO3f3SXFr9Vh7uYRwU3lOxdX7DRvuWFSFfDmBK797IZuSeNs00_3v4n4BUPpXrU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72928046</pqid></control><display><type>article</type><title>Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Fiore, Amory J ; Haid, Regis W ; Rodts, Gerald E ; Subach, Brian R ; Mummaneni, Praveen V ; Riedel, Charles J ; Birch, Barry D</creator><creatorcontrib>Fiore, Amory J ; Haid, Regis W ; Rodts, Gerald E ; Subach, Brian R ; Mummaneni, Praveen V ; Riedel, Charles J ; Birch, Barry D</creatorcontrib><description>A variety of techniques may be used to achieve fixation of the upper cervical spine. Transarticular atlantoaxial screws, posterior interspinous cable and graft constructs, and interlaminar clamps have been used effectively to achieve atlantoaxial fixation. Various anatomical factors, however, may preclude the successful application of these techniques. These factors include aberrant vertebral artery anatomy, irreducible atlantoaxial subluxation, exaggerated cervicothoracic kyphosis, and the absence of the osseous substrate for fixation. In these cases, an alternative method of fixation must be performed. The authors present an alternative method to achieve fixation of the atlas in which lateral mass screws can be applied to atlantoaxial and occipitocervical fixation. Between February 1998 and November 2001, eight patients who ranged in age from 16 to 74 years underwent posterior fixation for upper cervical instability. Diagnoses included C-2 metastastic disease in two patients, irreducible odontoid fractures in two patients, atlantoaxial subluxation in two patients, and transverse ligament synovial cyst in two patients. Various anatomical factors precluded transarticular atlantoaxial screw fixation in seven patients. One patient with a highly unstable spine due to a C-2 metastasis and pathological fracture underwent occipitocervical fusion. Atlantocervical fixation was achieved in seven patients by using varying constructs incorporating C-1 lateral mass screws. Occipitocervical fixation was achieved in one patient by incorporating C-1 lateral mass screws as an additional fixation point. A total of 14 C-1 lateral mass screws were placed in eight patients. There were no intraoperative complications. In all patients rigid fixation was achieved as demonstrated on postoperative radiographs. One patient died on postoperative Day 9 of aspiration pneumonia. At a mean follow-up time of 7.4 months, rigid fixation was maintained in all patients. Atlantal lateral mass screws can be used to provide a safe and efficacious means of achieving atlantoaxial fixation when anatomical constraints preclude the use of a more traditional procedure. Atlantal lateral mass screws may also be incorporated in occipitocervical constructs to provide additional fixation points which may prevent construct failure.</description><identifier>EISSN: 1092-0684</identifier><identifier>PMID: 16212332</identifier><language>eng</language><publisher>United States</publisher><subject>Adolescent ; Adult ; Aged ; Atlanto-Axial Joint - diagnostic imaging ; Atlanto-Axial Joint - surgery ; Bone Screws ; Cervical Vertebrae - diagnostic imaging ; Cervical Vertebrae - surgery ; Cervicoplasty - instrumentation ; Cervicoplasty - methods ; Female ; Humans ; Male ; Middle Aged ; Radiography</subject><ispartof>Neurosurgical focus, 2002-01, Vol.12 (1), p.E5-E5</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16212332$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fiore, Amory J</creatorcontrib><creatorcontrib>Haid, Regis W</creatorcontrib><creatorcontrib>Rodts, Gerald E</creatorcontrib><creatorcontrib>Subach, Brian R</creatorcontrib><creatorcontrib>Mummaneni, Praveen V</creatorcontrib><creatorcontrib>Riedel, Charles J</creatorcontrib><creatorcontrib>Birch, Barry D</creatorcontrib><title>Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series</title><title>Neurosurgical focus</title><addtitle>Neurosurg Focus</addtitle><description>A variety of techniques may be used to achieve fixation of the upper cervical spine. Transarticular atlantoaxial screws, posterior interspinous cable and graft constructs, and interlaminar clamps have been used effectively to achieve atlantoaxial fixation. Various anatomical factors, however, may preclude the successful application of these techniques. These factors include aberrant vertebral artery anatomy, irreducible atlantoaxial subluxation, exaggerated cervicothoracic kyphosis, and the absence of the osseous substrate for fixation. In these cases, an alternative method of fixation must be performed. The authors present an alternative method to achieve fixation of the atlas in which lateral mass screws can be applied to atlantoaxial and occipitocervical fixation. Between February 1998 and November 2001, eight patients who ranged in age from 16 to 74 years underwent posterior fixation for upper cervical instability. Diagnoses included C-2 metastastic disease in two patients, irreducible odontoid fractures in two patients, atlantoaxial subluxation in two patients, and transverse ligament synovial cyst in two patients. Various anatomical factors precluded transarticular atlantoaxial screw fixation in seven patients. One patient with a highly unstable spine due to a C-2 metastasis and pathological fracture underwent occipitocervical fusion. Atlantocervical fixation was achieved in seven patients by using varying constructs incorporating C-1 lateral mass screws. Occipitocervical fixation was achieved in one patient by incorporating C-1 lateral mass screws as an additional fixation point. A total of 14 C-1 lateral mass screws were placed in eight patients. There were no intraoperative complications. In all patients rigid fixation was achieved as demonstrated on postoperative radiographs. One patient died on postoperative Day 9 of aspiration pneumonia. At a mean follow-up time of 7.4 months, rigid fixation was maintained in all patients. Atlantal lateral mass screws can be used to provide a safe and efficacious means of achieving atlantoaxial fixation when anatomical constraints preclude the use of a more traditional procedure. Atlantal lateral mass screws may also be incorporated in occipitocervical constructs to provide additional fixation points which may prevent construct failure.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Atlanto-Axial Joint - diagnostic imaging</subject><subject>Atlanto-Axial Joint - surgery</subject><subject>Bone Screws</subject><subject>Cervical Vertebrae - diagnostic imaging</subject><subject>Cervical Vertebrae - surgery</subject><subject>Cervicoplasty - instrumentation</subject><subject>Cervicoplasty - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Radiography</subject><issn>1092-0684</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1kE9LxDAUxIMg7rr6FSQnb4U0SZPU27L4Dxa86LmmrwlW2qTmpYjf3oDraQbmNw_enJFtzVpeMWXkhlwifjImeKObC7KpFa-5EHxL3vd5siHbiU42u1R0togUIblvpD4mukQswVgcLmMoQHIQA-a0Qh5juKPZwUcYoSQhZkdtGChYdBRLy-EVOfd2Qnd90h15e7h_PTxVx5fH58P-WC01l7kCXnvFjNGC6d5bI4Zegm5lA6AkU63UveoHY6xvOAwevOXSN71T3urWDELsyO3f3SXFr9Vh7uYRwU3lOxdX7DRvuWFSFfDmBK797IZuSeNs00_3v4n4BUPpXrU</recordid><startdate>20020115</startdate><enddate>20020115</enddate><creator>Fiore, Amory J</creator><creator>Haid, Regis W</creator><creator>Rodts, Gerald E</creator><creator>Subach, Brian R</creator><creator>Mummaneni, Praveen V</creator><creator>Riedel, Charles J</creator><creator>Birch, Barry D</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20020115</creationdate><title>Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series</title><author>Fiore, Amory J ; Haid, Regis W ; Rodts, Gerald E ; Subach, Brian R ; Mummaneni, Praveen V ; Riedel, Charles J ; Birch, Barry D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p124t-c21f60887307bfa83db4c7945cc6406947b6bd88af52cdfcfa24f5be6fa798d33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Atlanto-Axial Joint - diagnostic imaging</topic><topic>Atlanto-Axial Joint - surgery</topic><topic>Bone Screws</topic><topic>Cervical Vertebrae - diagnostic imaging</topic><topic>Cervical Vertebrae - surgery</topic><topic>Cervicoplasty - instrumentation</topic><topic>Cervicoplasty - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Radiography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fiore, Amory J</creatorcontrib><creatorcontrib>Haid, Regis W</creatorcontrib><creatorcontrib>Rodts, Gerald E</creatorcontrib><creatorcontrib>Subach, Brian R</creatorcontrib><creatorcontrib>Mummaneni, Praveen V</creatorcontrib><creatorcontrib>Riedel, Charles J</creatorcontrib><creatorcontrib>Birch, Barry D</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Neurosurgical focus</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fiore, Amory J</au><au>Haid, Regis W</au><au>Rodts, Gerald E</au><au>Subach, Brian R</au><au>Mummaneni, Praveen V</au><au>Riedel, Charles J</au><au>Birch, Barry D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series</atitle><jtitle>Neurosurgical focus</jtitle><addtitle>Neurosurg Focus</addtitle><date>2002-01-15</date><risdate>2002</risdate><volume>12</volume><issue>1</issue><spage>E5</spage><epage>E5</epage><pages>E5-E5</pages><eissn>1092-0684</eissn><abstract>A variety of techniques may be used to achieve fixation of the upper cervical spine. Transarticular atlantoaxial screws, posterior interspinous cable and graft constructs, and interlaminar clamps have been used effectively to achieve atlantoaxial fixation. Various anatomical factors, however, may preclude the successful application of these techniques. These factors include aberrant vertebral artery anatomy, irreducible atlantoaxial subluxation, exaggerated cervicothoracic kyphosis, and the absence of the osseous substrate for fixation. In these cases, an alternative method of fixation must be performed. The authors present an alternative method to achieve fixation of the atlas in which lateral mass screws can be applied to atlantoaxial and occipitocervical fixation. Between February 1998 and November 2001, eight patients who ranged in age from 16 to 74 years underwent posterior fixation for upper cervical instability. Diagnoses included C-2 metastastic disease in two patients, irreducible odontoid fractures in two patients, atlantoaxial subluxation in two patients, and transverse ligament synovial cyst in two patients. Various anatomical factors precluded transarticular atlantoaxial screw fixation in seven patients. One patient with a highly unstable spine due to a C-2 metastasis and pathological fracture underwent occipitocervical fusion. Atlantocervical fixation was achieved in seven patients by using varying constructs incorporating C-1 lateral mass screws. Occipitocervical fixation was achieved in one patient by incorporating C-1 lateral mass screws as an additional fixation point. A total of 14 C-1 lateral mass screws were placed in eight patients. There were no intraoperative complications. In all patients rigid fixation was achieved as demonstrated on postoperative radiographs. One patient died on postoperative Day 9 of aspiration pneumonia. At a mean follow-up time of 7.4 months, rigid fixation was maintained in all patients. Atlantal lateral mass screws can be used to provide a safe and efficacious means of achieving atlantoaxial fixation when anatomical constraints preclude the use of a more traditional procedure. Atlantal lateral mass screws may also be incorporated in occipitocervical constructs to provide additional fixation points which may prevent construct failure.</abstract><cop>United States</cop><pmid>16212332</pmid></addata></record>
fulltext fulltext
identifier EISSN: 1092-0684
ispartof Neurosurgical focus, 2002-01, Vol.12 (1), p.E5-E5
issn 1092-0684
language eng
recordid cdi_proquest_miscellaneous_72928046
source MEDLINE; EZB-FREE-00999 freely available EZB journals
subjects Adolescent
Adult
Aged
Atlanto-Axial Joint - diagnostic imaging
Atlanto-Axial Joint - surgery
Bone Screws
Cervical Vertebrae - diagnostic imaging
Cervical Vertebrae - surgery
Cervicoplasty - instrumentation
Cervicoplasty - methods
Female
Humans
Male
Middle Aged
Radiography
title Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T05%3A28%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Atlantal%20lateral%20mass%20screws%20for%20posterior%20spinal%20reconstruction:%20technical%20note%20and%20case%20series&rft.jtitle=Neurosurgical%20focus&rft.au=Fiore,%20Amory%20J&rft.date=2002-01-15&rft.volume=12&rft.issue=1&rft.spage=E5&rft.epage=E5&rft.pages=E5-E5&rft.eissn=1092-0684&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E72928046%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72928046&rft_id=info:pmid/16212332&rfr_iscdi=true