The use of beam's eye view volumetrics in the selection of non-coplanar radiation portals
In 3-dimensional treatment planning, beam's eye view (BEV) is used as an interactive tool to define portal entry angles that exclude critical structures while fully encompassing the target volume. With beam's eye view volumetrics (BEV volumetrics), the volume of intersected normal tissues...
Gespeichert in:
Veröffentlicht in: | International journal of radiation oncology, biology, physics biology, physics, 1992, Vol.23 (1), p.153-163 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 163 |
---|---|
container_issue | 1 |
container_start_page | 153 |
container_title | International journal of radiation oncology, biology, physics |
container_volume | 23 |
creator | Chen, George T.Y. Spelbring, Danny R. Pelizzari, Charles A. Balter, James M. Myrianthopoulos, Leon C. Vijayakumar, S. Halpern, Howard |
description | In 3-dimensional treatment planning, beam's eye view (BEV) is used as an interactive tool to define portal entry angles that exclude critical structures while fully encompassing the target volume. With beam's eye view volumetrics (BEV volumetrics), the volume of intersected normal tissues is also calculated and is used as a quantitative tool to choose portal orientations that minimize normal tissue volumes irradiated. The axial beam entry angle and a polar angle (relative to the patient longitudinal axis) are specified to define the central axis orientation. Using BEV volumetrics, we have studied the quantities of normal tissues irradiated when treating tumors in the abdomen, thorax, and pelvis. The reduction of normal tissue irradiated is a strong function of site and patient-specific tumor size and location. Volumetrics combined with BEV is found to be useful in treatment planning because it (a) provides quantitative information needed in rationally choosing portal entry angles, (b) provides a near interactive speed approach to understanding the relative merits of different multiple field plans, and (c) compliments the information provided by the more time-consuming generation of dose volume histograms. |
doi_str_mv | 10.1016/0360-3016(92)90555-V |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72911647</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>036030169290555V</els_id><sourcerecordid>72911647</sourcerecordid><originalsourceid>FETCH-LOGICAL-c347v-1b14a2f9b103c19d1d5519d97f33f9e0f8aa4be9712e9ec3f3d5e5f40ddbdf33</originalsourceid><addsrcrecordid>eNp9kF1LHDEUhoO06PrxDyzkoqi9GM2ZJDubG0FE24LQm0X0KmSSExqZmWyTmS3-e7PuYu969Qbe5xxOHkJOgV0Cg_kV43NW8fK6UPU3xaSU1eMemcGiURWX8ukTmX0gB-Qw5xfGGEAj9sk-yKZeQD0jz8vfSKeMNHraounPM8VXpOuAf-k6dlOPYwo20zDQsZAZO7RjiMOGH-JQ2bjqzGASTcYF896sYhpNl4_JZ18CT3Z5RJb3d8vbH9XDr-8_b28eKstFs66gBWFqr1pg3IJy4KQsoRrPuVfI_MIY0aJqoEaFlnvuJEovmHOtK8wROduuXaX4Z8I86j5ki125CuOUdVMrgLloCii2oE0x54Rer1LoTXrVwPRGqN7Y0htbWtX6Xah-LGNfdvuntkf3b2hrsPRfd73J1nQ-mcGG_IGJ8klZi4JdbzEsKordpLMNOFh0IRWj2sXw_zveADtfkqA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72911647</pqid></control><display><type>article</type><title>The use of beam's eye view volumetrics in the selection of non-coplanar radiation portals</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Chen, George T.Y. ; Spelbring, Danny R. ; Pelizzari, Charles A. ; Balter, James M. ; Myrianthopoulos, Leon C. ; Vijayakumar, S. ; Halpern, Howard</creator><creatorcontrib>Chen, George T.Y. ; Spelbring, Danny R. ; Pelizzari, Charles A. ; Balter, James M. ; Myrianthopoulos, Leon C. ; Vijayakumar, S. ; Halpern, Howard</creatorcontrib><description>In 3-dimensional treatment planning, beam's eye view (BEV) is used as an interactive tool to define portal entry angles that exclude critical structures while fully encompassing the target volume. With beam's eye view volumetrics (BEV volumetrics), the volume of intersected normal tissues is also calculated and is used as a quantitative tool to choose portal orientations that minimize normal tissue volumes irradiated. The axial beam entry angle and a polar angle (relative to the patient longitudinal axis) are specified to define the central axis orientation. Using BEV volumetrics, we have studied the quantities of normal tissues irradiated when treating tumors in the abdomen, thorax, and pelvis. The reduction of normal tissue irradiated is a strong function of site and patient-specific tumor size and location. Volumetrics combined with BEV is found to be useful in treatment planning because it (a) provides quantitative information needed in rationally choosing portal entry angles, (b) provides a near interactive speed approach to understanding the relative merits of different multiple field plans, and (c) compliments the information provided by the more time-consuming generation of dose volume histograms.</description><identifier>ISSN: 0360-3016</identifier><identifier>EISSN: 1879-355X</identifier><identifier>DOI: 10.1016/0360-3016(92)90555-V</identifier><identifier>PMID: 1572812</identifier><identifier>CODEN: IOBPD3</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Beam's eye view ; Biological and medical sciences ; Humans ; Image Processing, Computer-Assisted ; Medical sciences ; Radiotherapy Planning, Computer-Assisted - methods ; Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects) ; Technology, Radiologic ; Technology. Biomaterials. Equipments. Material. Instrumentation ; Three-dimensional computerized treatment planning ; Treatment plan optimization</subject><ispartof>International journal of radiation oncology, biology, physics, 1992, Vol.23 (1), p.153-163</ispartof><rights>1992</rights><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c347v-1b14a2f9b103c19d1d5519d97f33f9e0f8aa4be9712e9ec3f3d5e5f40ddbdf33</citedby><cites>FETCH-LOGICAL-c347v-1b14a2f9b103c19d1d5519d97f33f9e0f8aa4be9712e9ec3f3d5e5f40ddbdf33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/036030169290555V$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,3537,4010,4036,4037,23909,23910,25118,27900,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=4347524$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1572812$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, George T.Y.</creatorcontrib><creatorcontrib>Spelbring, Danny R.</creatorcontrib><creatorcontrib>Pelizzari, Charles A.</creatorcontrib><creatorcontrib>Balter, James M.</creatorcontrib><creatorcontrib>Myrianthopoulos, Leon C.</creatorcontrib><creatorcontrib>Vijayakumar, S.</creatorcontrib><creatorcontrib>Halpern, Howard</creatorcontrib><title>The use of beam's eye view volumetrics in the selection of non-coplanar radiation portals</title><title>International journal of radiation oncology, biology, physics</title><addtitle>Int J Radiat Oncol Biol Phys</addtitle><description>In 3-dimensional treatment planning, beam's eye view (BEV) is used as an interactive tool to define portal entry angles that exclude critical structures while fully encompassing the target volume. With beam's eye view volumetrics (BEV volumetrics), the volume of intersected normal tissues is also calculated and is used as a quantitative tool to choose portal orientations that minimize normal tissue volumes irradiated. The axial beam entry angle and a polar angle (relative to the patient longitudinal axis) are specified to define the central axis orientation. Using BEV volumetrics, we have studied the quantities of normal tissues irradiated when treating tumors in the abdomen, thorax, and pelvis. The reduction of normal tissue irradiated is a strong function of site and patient-specific tumor size and location. Volumetrics combined with BEV is found to be useful in treatment planning because it (a) provides quantitative information needed in rationally choosing portal entry angles, (b) provides a near interactive speed approach to understanding the relative merits of different multiple field plans, and (c) compliments the information provided by the more time-consuming generation of dose volume histograms.</description><subject>Beam's eye view</subject><subject>Biological and medical sciences</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted</subject><subject>Medical sciences</subject><subject>Radiotherapy Planning, Computer-Assisted - methods</subject><subject>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</subject><subject>Technology, Radiologic</subject><subject>Technology. Biomaterials. Equipments. Material. Instrumentation</subject><subject>Three-dimensional computerized treatment planning</subject><subject>Treatment plan optimization</subject><issn>0360-3016</issn><issn>1879-355X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kF1LHDEUhoO06PrxDyzkoqi9GM2ZJDubG0FE24LQm0X0KmSSExqZmWyTmS3-e7PuYu969Qbe5xxOHkJOgV0Cg_kV43NW8fK6UPU3xaSU1eMemcGiURWX8ukTmX0gB-Qw5xfGGEAj9sk-yKZeQD0jz8vfSKeMNHraounPM8VXpOuAf-k6dlOPYwo20zDQsZAZO7RjiMOGH-JQ2bjqzGASTcYF896sYhpNl4_JZ18CT3Z5RJb3d8vbH9XDr-8_b28eKstFs66gBWFqr1pg3IJy4KQsoRrPuVfI_MIY0aJqoEaFlnvuJEovmHOtK8wROduuXaX4Z8I86j5ki125CuOUdVMrgLloCii2oE0x54Rer1LoTXrVwPRGqN7Y0htbWtX6Xah-LGNfdvuntkf3b2hrsPRfd73J1nQ-mcGG_IGJ8klZi4JdbzEsKordpLMNOFh0IRWj2sXw_zveADtfkqA</recordid><startdate>1992</startdate><enddate>1992</enddate><creator>Chen, George T.Y.</creator><creator>Spelbring, Danny R.</creator><creator>Pelizzari, Charles A.</creator><creator>Balter, James M.</creator><creator>Myrianthopoulos, Leon C.</creator><creator>Vijayakumar, S.</creator><creator>Halpern, Howard</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1992</creationdate><title>The use of beam's eye view volumetrics in the selection of non-coplanar radiation portals</title><author>Chen, George T.Y. ; Spelbring, Danny R. ; Pelizzari, Charles A. ; Balter, James M. ; Myrianthopoulos, Leon C. ; Vijayakumar, S. ; Halpern, Howard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c347v-1b14a2f9b103c19d1d5519d97f33f9e0f8aa4be9712e9ec3f3d5e5f40ddbdf33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Beam's eye view</topic><topic>Biological and medical sciences</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted</topic><topic>Medical sciences</topic><topic>Radiotherapy Planning, Computer-Assisted - methods</topic><topic>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</topic><topic>Technology, Radiologic</topic><topic>Technology. Biomaterials. Equipments. Material. Instrumentation</topic><topic>Three-dimensional computerized treatment planning</topic><topic>Treatment plan optimization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, George T.Y.</creatorcontrib><creatorcontrib>Spelbring, Danny R.</creatorcontrib><creatorcontrib>Pelizzari, Charles A.</creatorcontrib><creatorcontrib>Balter, James M.</creatorcontrib><creatorcontrib>Myrianthopoulos, Leon C.</creatorcontrib><creatorcontrib>Vijayakumar, S.</creatorcontrib><creatorcontrib>Halpern, Howard</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of radiation oncology, biology, physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, George T.Y.</au><au>Spelbring, Danny R.</au><au>Pelizzari, Charles A.</au><au>Balter, James M.</au><au>Myrianthopoulos, Leon C.</au><au>Vijayakumar, S.</au><au>Halpern, Howard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The use of beam's eye view volumetrics in the selection of non-coplanar radiation portals</atitle><jtitle>International journal of radiation oncology, biology, physics</jtitle><addtitle>Int J Radiat Oncol Biol Phys</addtitle><date>1992</date><risdate>1992</risdate><volume>23</volume><issue>1</issue><spage>153</spage><epage>163</epage><pages>153-163</pages><issn>0360-3016</issn><eissn>1879-355X</eissn><coden>IOBPD3</coden><abstract>In 3-dimensional treatment planning, beam's eye view (BEV) is used as an interactive tool to define portal entry angles that exclude critical structures while fully encompassing the target volume. With beam's eye view volumetrics (BEV volumetrics), the volume of intersected normal tissues is also calculated and is used as a quantitative tool to choose portal orientations that minimize normal tissue volumes irradiated. The axial beam entry angle and a polar angle (relative to the patient longitudinal axis) are specified to define the central axis orientation. Using BEV volumetrics, we have studied the quantities of normal tissues irradiated when treating tumors in the abdomen, thorax, and pelvis. The reduction of normal tissue irradiated is a strong function of site and patient-specific tumor size and location. Volumetrics combined with BEV is found to be useful in treatment planning because it (a) provides quantitative information needed in rationally choosing portal entry angles, (b) provides a near interactive speed approach to understanding the relative merits of different multiple field plans, and (c) compliments the information provided by the more time-consuming generation of dose volume histograms.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>1572812</pmid><doi>10.1016/0360-3016(92)90555-V</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0360-3016 |
ispartof | International journal of radiation oncology, biology, physics, 1992, Vol.23 (1), p.153-163 |
issn | 0360-3016 1879-355X |
language | eng |
recordid | cdi_proquest_miscellaneous_72911647 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Beam's eye view Biological and medical sciences Humans Image Processing, Computer-Assisted Medical sciences Radiotherapy Planning, Computer-Assisted - methods Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects) Technology, Radiologic Technology. Biomaterials. Equipments. Material. Instrumentation Three-dimensional computerized treatment planning Treatment plan optimization |
title | The use of beam's eye view volumetrics in the selection of non-coplanar radiation portals |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-30T14%3A11%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20use%20of%20beam's%20eye%20view%20volumetrics%20in%20the%20selection%20of%20non-coplanar%20radiation%20portals&rft.jtitle=International%20journal%20of%20radiation%20oncology,%20biology,%20physics&rft.au=Chen,%20George%20T.Y.&rft.date=1992&rft.volume=23&rft.issue=1&rft.spage=153&rft.epage=163&rft.pages=153-163&rft.issn=0360-3016&rft.eissn=1879-355X&rft.coden=IOBPD3&rft_id=info:doi/10.1016/0360-3016(92)90555-V&rft_dat=%3Cproquest_cross%3E72911647%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72911647&rft_id=info:pmid/1572812&rft_els_id=036030169290555V&rfr_iscdi=true |