An evaluation of point-of-care instrument for monitoring anticoagulation level in adult cardiac patients

Rapid point-of-care measurement of anticoagulation has become feasible with the advent of new portable devices and offers the potential for home monitoring. This study evaluates the accuracy and feasibility of such a point-of-care device, the ProTime analyser as compared with standard laboratory met...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Singapore medical journal 2002-11, Vol.43 (11), p.557-562
Hauptverfasser: TAY, M. H, TIEN, S. L, CHUA, T. S. J, SIM, L. L, KOH, T. H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 562
container_issue 11
container_start_page 557
container_title Singapore medical journal
container_volume 43
creator TAY, M. H
TIEN, S. L
CHUA, T. S. J
SIM, L. L
KOH, T. H
description Rapid point-of-care measurement of anticoagulation has become feasible with the advent of new portable devices and offers the potential for home monitoring. This study evaluates the accuracy and feasibility of such a point-of-care device, the ProTime analyser as compared with standard laboratory method (IL MCL2) for monitoring the International Normalised Ratio (INR) level in cardiac patients on oral anticoagulation therapy. Fifty patients were studied. The majority were male (86% versus 14%). Chinese accounted for 37(74%) whereas Malay and Indian, constituted 9(18%) and 4(8%) respectively. The mean age was 55 +/- 12 years. Prosthetic heart valve replacement (46%) and atrial fibrillation (38%) were among the main indications for anticoagulation. The mean dosage of warfarin was 3.0 +/- 1.5 mg (range 1.0 to 6.5 mg) and the INR results ranged from 0.83 to 4.69 (based on the hospital laboratory method). Fingerstick and venous blood samples were collected from every patient and subjected to analysis by ProTime and IL MCL2 analysers. There was a good correlation of INRs between ProTime venous and IL MCL2 venous, ProTime fingerstick and IL MCL2 venous and ProTime venous and ProTime fingerstick samplings, with correlation coefficients (r) of 0.9248, 0.9403 and 0.9557, respectively. The Bland-Altman plot also showed a good correlation between the methods used without any systematic bias (limits of agreement ranged from -0.422 to +0.606 INR units on average). This rapid point-of-care device appears to have an acceptable level of accuracy for measuring INR values in the recommended target ranges in adult cardiac patients on oral anticoagulation therapy.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_72873927</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72873927</sourcerecordid><originalsourceid>FETCH-LOGICAL-p154t-e1db24d78618670e19f35f3c31e65ffc755334fa21f658316f197da2edd1bc8b3</originalsourceid><addsrcrecordid>eNpF0DtPwzAQwPEMIFoKXwF5gS1SbMexM1YVL6kSC8zRxY9i5NjBj0p8eyK1iOmG-_1vuItq3TSU16zjbFVdp_TVNIQ3QlxVK0w60TBC19Xn1iN9BFcg2-BRMGgO1uc6mFpC1Mj6lGOZtM_IhIim4G0O0foDAp-tDHAo7pQ6fdRu8QhUcRkttbIg0bxslzrdVJcGXNK357mpPp4e33cv9f7t-XW33dczZm2uNVYjaRUXHRYdbzTuDWWGSop1x4yRnDFKWwMEm44JijuDe66AaKXwKMVIN9XD6e4cw3fRKQ-TTVI7B16HkgZOBKc94Qu8O8MyTloNc7QTxJ_h7zcLuD8DSBKcieClTf-ubSmjPae_wVlt_A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72873927</pqid></control><display><type>article</type><title>An evaluation of point-of-care instrument for monitoring anticoagulation level in adult cardiac patients</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>TAY, M. H ; TIEN, S. L ; CHUA, T. S. J ; SIM, L. L ; KOH, T. H</creator><creatorcontrib>TAY, M. H ; TIEN, S. L ; CHUA, T. S. J ; SIM, L. L ; KOH, T. H</creatorcontrib><description>Rapid point-of-care measurement of anticoagulation has become feasible with the advent of new portable devices and offers the potential for home monitoring. This study evaluates the accuracy and feasibility of such a point-of-care device, the ProTime analyser as compared with standard laboratory method (IL MCL2) for monitoring the International Normalised Ratio (INR) level in cardiac patients on oral anticoagulation therapy. Fifty patients were studied. The majority were male (86% versus 14%). Chinese accounted for 37(74%) whereas Malay and Indian, constituted 9(18%) and 4(8%) respectively. The mean age was 55 +/- 12 years. Prosthetic heart valve replacement (46%) and atrial fibrillation (38%) were among the main indications for anticoagulation. The mean dosage of warfarin was 3.0 +/- 1.5 mg (range 1.0 to 6.5 mg) and the INR results ranged from 0.83 to 4.69 (based on the hospital laboratory method). Fingerstick and venous blood samples were collected from every patient and subjected to analysis by ProTime and IL MCL2 analysers. There was a good correlation of INRs between ProTime venous and IL MCL2 venous, ProTime fingerstick and IL MCL2 venous and ProTime venous and ProTime fingerstick samplings, with correlation coefficients (r) of 0.9248, 0.9403 and 0.9557, respectively. The Bland-Altman plot also showed a good correlation between the methods used without any systematic bias (limits of agreement ranged from -0.422 to +0.606 INR units on average). This rapid point-of-care device appears to have an acceptable level of accuracy for measuring INR values in the recommended target ranges in adult cardiac patients on oral anticoagulation therapy.</description><identifier>ISSN: 0037-5675</identifier><identifier>PMID: 12680523</identifier><identifier>CODEN: SIMJA3</identifier><language>eng</language><publisher>Singapore: Singapore Medical Association</publisher><subject>Adult ; Aged ; Aged, 80 and over ; Anticoagulants - administration &amp; dosage ; Biological and medical sciences ; Blood. Blood coagulation. Reticuloendothelial system ; Cardiovascular Diseases ; Drug Monitoring - instrumentation ; Drug Monitoring - methods ; Equipment Design ; Feasibility Studies ; Female ; Humans ; International Normalized Ratio ; Male ; Medical sciences ; Middle Aged ; Pharmacology. Drug treatments ; Point-of-Care Systems ; Singapore</subject><ispartof>Singapore medical journal, 2002-11, Vol.43 (11), p.557-562</ispartof><rights>2003 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=14435397$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12680523$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>TAY, M. H</creatorcontrib><creatorcontrib>TIEN, S. L</creatorcontrib><creatorcontrib>CHUA, T. S. J</creatorcontrib><creatorcontrib>SIM, L. L</creatorcontrib><creatorcontrib>KOH, T. H</creatorcontrib><title>An evaluation of point-of-care instrument for monitoring anticoagulation level in adult cardiac patients</title><title>Singapore medical journal</title><addtitle>Singapore Med J</addtitle><description>Rapid point-of-care measurement of anticoagulation has become feasible with the advent of new portable devices and offers the potential for home monitoring. This study evaluates the accuracy and feasibility of such a point-of-care device, the ProTime analyser as compared with standard laboratory method (IL MCL2) for monitoring the International Normalised Ratio (INR) level in cardiac patients on oral anticoagulation therapy. Fifty patients were studied. The majority were male (86% versus 14%). Chinese accounted for 37(74%) whereas Malay and Indian, constituted 9(18%) and 4(8%) respectively. The mean age was 55 +/- 12 years. Prosthetic heart valve replacement (46%) and atrial fibrillation (38%) were among the main indications for anticoagulation. The mean dosage of warfarin was 3.0 +/- 1.5 mg (range 1.0 to 6.5 mg) and the INR results ranged from 0.83 to 4.69 (based on the hospital laboratory method). Fingerstick and venous blood samples were collected from every patient and subjected to analysis by ProTime and IL MCL2 analysers. There was a good correlation of INRs between ProTime venous and IL MCL2 venous, ProTime fingerstick and IL MCL2 venous and ProTime venous and ProTime fingerstick samplings, with correlation coefficients (r) of 0.9248, 0.9403 and 0.9557, respectively. The Bland-Altman plot also showed a good correlation between the methods used without any systematic bias (limits of agreement ranged from -0.422 to +0.606 INR units on average). This rapid point-of-care device appears to have an acceptable level of accuracy for measuring INR values in the recommended target ranges in adult cardiac patients on oral anticoagulation therapy.</description><subject>Adult</subject><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Anticoagulants - administration &amp; dosage</subject><subject>Biological and medical sciences</subject><subject>Blood. Blood coagulation. Reticuloendothelial system</subject><subject>Cardiovascular Diseases</subject><subject>Drug Monitoring - instrumentation</subject><subject>Drug Monitoring - methods</subject><subject>Equipment Design</subject><subject>Feasibility Studies</subject><subject>Female</subject><subject>Humans</subject><subject>International Normalized Ratio</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Pharmacology. Drug treatments</subject><subject>Point-of-Care Systems</subject><subject>Singapore</subject><issn>0037-5675</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpF0DtPwzAQwPEMIFoKXwF5gS1SbMexM1YVL6kSC8zRxY9i5NjBj0p8eyK1iOmG-_1vuItq3TSU16zjbFVdp_TVNIQ3QlxVK0w60TBC19Xn1iN9BFcg2-BRMGgO1uc6mFpC1Mj6lGOZtM_IhIim4G0O0foDAp-tDHAo7pQ6fdRu8QhUcRkttbIg0bxslzrdVJcGXNK357mpPp4e33cv9f7t-XW33dczZm2uNVYjaRUXHRYdbzTuDWWGSop1x4yRnDFKWwMEm44JijuDe66AaKXwKMVIN9XD6e4cw3fRKQ-TTVI7B16HkgZOBKc94Qu8O8MyTloNc7QTxJ_h7zcLuD8DSBKcieClTf-ubSmjPae_wVlt_A</recordid><startdate>20021101</startdate><enddate>20021101</enddate><creator>TAY, M. H</creator><creator>TIEN, S. L</creator><creator>CHUA, T. S. J</creator><creator>SIM, L. L</creator><creator>KOH, T. H</creator><general>Singapore Medical Association</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20021101</creationdate><title>An evaluation of point-of-care instrument for monitoring anticoagulation level in adult cardiac patients</title><author>TAY, M. H ; TIEN, S. L ; CHUA, T. S. J ; SIM, L. L ; KOH, T. H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p154t-e1db24d78618670e19f35f3c31e65ffc755334fa21f658316f197da2edd1bc8b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Anticoagulants - administration &amp; dosage</topic><topic>Biological and medical sciences</topic><topic>Blood. Blood coagulation. Reticuloendothelial system</topic><topic>Cardiovascular Diseases</topic><topic>Drug Monitoring - instrumentation</topic><topic>Drug Monitoring - methods</topic><topic>Equipment Design</topic><topic>Feasibility Studies</topic><topic>Female</topic><topic>Humans</topic><topic>International Normalized Ratio</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Pharmacology. Drug treatments</topic><topic>Point-of-Care Systems</topic><topic>Singapore</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>TAY, M. H</creatorcontrib><creatorcontrib>TIEN, S. L</creatorcontrib><creatorcontrib>CHUA, T. S. J</creatorcontrib><creatorcontrib>SIM, L. L</creatorcontrib><creatorcontrib>KOH, T. H</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Singapore medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>TAY, M. H</au><au>TIEN, S. L</au><au>CHUA, T. S. J</au><au>SIM, L. L</au><au>KOH, T. H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An evaluation of point-of-care instrument for monitoring anticoagulation level in adult cardiac patients</atitle><jtitle>Singapore medical journal</jtitle><addtitle>Singapore Med J</addtitle><date>2002-11-01</date><risdate>2002</risdate><volume>43</volume><issue>11</issue><spage>557</spage><epage>562</epage><pages>557-562</pages><issn>0037-5675</issn><coden>SIMJA3</coden><abstract>Rapid point-of-care measurement of anticoagulation has become feasible with the advent of new portable devices and offers the potential for home monitoring. This study evaluates the accuracy and feasibility of such a point-of-care device, the ProTime analyser as compared with standard laboratory method (IL MCL2) for monitoring the International Normalised Ratio (INR) level in cardiac patients on oral anticoagulation therapy. Fifty patients were studied. The majority were male (86% versus 14%). Chinese accounted for 37(74%) whereas Malay and Indian, constituted 9(18%) and 4(8%) respectively. The mean age was 55 +/- 12 years. Prosthetic heart valve replacement (46%) and atrial fibrillation (38%) were among the main indications for anticoagulation. The mean dosage of warfarin was 3.0 +/- 1.5 mg (range 1.0 to 6.5 mg) and the INR results ranged from 0.83 to 4.69 (based on the hospital laboratory method). Fingerstick and venous blood samples were collected from every patient and subjected to analysis by ProTime and IL MCL2 analysers. There was a good correlation of INRs between ProTime venous and IL MCL2 venous, ProTime fingerstick and IL MCL2 venous and ProTime venous and ProTime fingerstick samplings, with correlation coefficients (r) of 0.9248, 0.9403 and 0.9557, respectively. The Bland-Altman plot also showed a good correlation between the methods used without any systematic bias (limits of agreement ranged from -0.422 to +0.606 INR units on average). This rapid point-of-care device appears to have an acceptable level of accuracy for measuring INR values in the recommended target ranges in adult cardiac patients on oral anticoagulation therapy.</abstract><cop>Singapore</cop><pub>Singapore Medical Association</pub><pmid>12680523</pmid><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0037-5675
ispartof Singapore medical journal, 2002-11, Vol.43 (11), p.557-562
issn 0037-5675
language eng
recordid cdi_proquest_miscellaneous_72873927
source MEDLINE; EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
subjects Adult
Aged
Aged, 80 and over
Anticoagulants - administration & dosage
Biological and medical sciences
Blood. Blood coagulation. Reticuloendothelial system
Cardiovascular Diseases
Drug Monitoring - instrumentation
Drug Monitoring - methods
Equipment Design
Feasibility Studies
Female
Humans
International Normalized Ratio
Male
Medical sciences
Middle Aged
Pharmacology. Drug treatments
Point-of-Care Systems
Singapore
title An evaluation of point-of-care instrument for monitoring anticoagulation level in adult cardiac patients
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T09%3A00%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20evaluation%20of%20point-of-care%20instrument%20for%20monitoring%20anticoagulation%20level%20in%20adult%20cardiac%20patients&rft.jtitle=Singapore%20medical%20journal&rft.au=TAY,%20M.%20H&rft.date=2002-11-01&rft.volume=43&rft.issue=11&rft.spage=557&rft.epage=562&rft.pages=557-562&rft.issn=0037-5675&rft.coden=SIMJA3&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E72873927%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72873927&rft_id=info:pmid/12680523&rfr_iscdi=true