Computed Tomography in the Evaluation of the Portal Venous System

Computed tomography has widespread clinical application in the evaluation of the portal venous system, even though quantitative methods are impractical due to the inability to measure portal flow discrete from hepatic arterial flow, morbidity associated with the use of large volumes of iodinated con...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical gastroenterology 1992-03, Vol.14 (2), p.167-172
1. Verfasser: Taylor, Caroline R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 172
container_issue 2
container_start_page 167
container_title Journal of clinical gastroenterology
container_volume 14
creator Taylor, Caroline R
description Computed tomography has widespread clinical application in the evaluation of the portal venous system, even though quantitative methods are impractical due to the inability to measure portal flow discrete from hepatic arterial flow, morbidity associated with the use of large volumes of iodinated contrast, and technical limitations. This represents a major disadvantage compared to Doppler ultrasound and magnetic resonance angiography. Qualitative applications include evaluation of portal vein patency, diagnosis of portal vein thrombosis, underlying inflammatory or neoplastic conditions, and evaluation of surgically created portosystemic shunts and collateral flow. Diagnostic criteria for portal venous thrombosis include nonopacification of the central portion of the portal vein, peripheral enhancement of the vein, and irregular periportal hepatic parenchymal enhancement. However, misdiagnosis is common, occurring in 16% of cases analyzed in one limited series, and periportal vein enhancement is now recognized as a nonspecific finding associated with underlying endothelial injury. Cavernous transformation of the portal vein and neoplastic invasion of the portal system are more reliably recognized. Computed tomography arterial portography demonstrates collateral pathways and arteriovenous shunts. Computed tomography has a sensitivity of 85% in detection of esophageal varices compared to endoscopy, but has the advantage of demonstrating splenorenal, gastrorenal, peripancreatic, pericholecystic, retroperitoneal and omental collateral vessels, and spontaneous large portosystemic shunts, with greater sensitivity than angiography. Computed tomography combined with Doppler ultrasound angiography remains popular, despite a lack of large-scale prospective efficacy studies demonstrating diagnostic superiority over other imaging techniques, largely because of its accessibility, and its detailed axial anatomic images providing an overview of multiple organ systems, and patency of major vessels.
doi_str_mv 10.1097/00004836-199203000-00021
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72865689</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72865689</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3841-3bfe54358bc402e1e3d6274e7d6e644c08a20c29c8f92d79a71b431d634412233</originalsourceid><addsrcrecordid>eNp1kUtLAzEQgIMoWqs_QdiDeFvNa7PJsRRfUFDwcQ1pdtauZjc12bX03xtt1ZOBEDLzTWb4glBG8DnBqrzAaXHJRE6UopilW542JTtoRAqm8hQju2iEiaI5LhU-QIcxvmJMSsbIPtonRSE44yM0mfp2OfRQZY--9S_BLBfrrOmyfgHZ5Ydxg-kb32W-_o7c-9Ablz1D54eYPaxjD-0R2quNi3C8Pcfo6erycXqTz-6ub6eTWW6Z5CRn8xoKzgo5txxTIMAqQUsOZSVAcG6xNBRbqqysFa1KZUoy54xUgnFOKGVsjM427y6Dfx8g9rptogXnTAdpGl1SKQohVQLlBrTBxxig1svQtCasNcH6y57-sad_7elve6n0ZNtjmLdQ_RVudKX86TZvojWuDqazTfzFCkqxkEXC-AZbeddDiG9uWEHQCzCuX-j__o59AsGHhLw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72865689</pqid></control><display><type>article</type><title>Computed Tomography in the Evaluation of the Portal Venous System</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Taylor, Caroline R</creator><creatorcontrib>Taylor, Caroline R</creatorcontrib><description>Computed tomography has widespread clinical application in the evaluation of the portal venous system, even though quantitative methods are impractical due to the inability to measure portal flow discrete from hepatic arterial flow, morbidity associated with the use of large volumes of iodinated contrast, and technical limitations. This represents a major disadvantage compared to Doppler ultrasound and magnetic resonance angiography. Qualitative applications include evaluation of portal vein patency, diagnosis of portal vein thrombosis, underlying inflammatory or neoplastic conditions, and evaluation of surgically created portosystemic shunts and collateral flow. Diagnostic criteria for portal venous thrombosis include nonopacification of the central portion of the portal vein, peripheral enhancement of the vein, and irregular periportal hepatic parenchymal enhancement. However, misdiagnosis is common, occurring in 16% of cases analyzed in one limited series, and periportal vein enhancement is now recognized as a nonspecific finding associated with underlying endothelial injury. Cavernous transformation of the portal vein and neoplastic invasion of the portal system are more reliably recognized. Computed tomography arterial portography demonstrates collateral pathways and arteriovenous shunts. Computed tomography has a sensitivity of 85% in detection of esophageal varices compared to endoscopy, but has the advantage of demonstrating splenorenal, gastrorenal, peripancreatic, pericholecystic, retroperitoneal and omental collateral vessels, and spontaneous large portosystemic shunts, with greater sensitivity than angiography. Computed tomography combined with Doppler ultrasound angiography remains popular, despite a lack of large-scale prospective efficacy studies demonstrating diagnostic superiority over other imaging techniques, largely because of its accessibility, and its detailed axial anatomic images providing an overview of multiple organ systems, and patency of major vessels.</description><identifier>ISSN: 0192-0790</identifier><identifier>EISSN: 1539-2031</identifier><identifier>DOI: 10.1097/00004836-199203000-00021</identifier><identifier>PMID: 1556434</identifier><identifier>CODEN: JCGADC</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott-Raven Publishers</publisher><subject>Biological and medical sciences ; Collateral Circulation - physiology ; Digestive system ; Humans ; Hypertension, Portal - diagnostic imaging ; Investigative techniques, diagnostic techniques (general aspects) ; Medical sciences ; Portal System - diagnostic imaging ; Portal System - physiology ; Portal Vein - diagnostic imaging ; Portasystemic Shunt, Surgical ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Sensitivity and Specificity ; Thrombosis - diagnostic imaging ; Tomography, X-Ray Computed</subject><ispartof>Journal of clinical gastroenterology, 1992-03, Vol.14 (2), p.167-172</ispartof><rights>Lippincott-Raven Publishers.</rights><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3841-3bfe54358bc402e1e3d6274e7d6e644c08a20c29c8f92d79a71b431d634412233</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=5220685$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1556434$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Taylor, Caroline R</creatorcontrib><title>Computed Tomography in the Evaluation of the Portal Venous System</title><title>Journal of clinical gastroenterology</title><addtitle>J Clin Gastroenterol</addtitle><description>Computed tomography has widespread clinical application in the evaluation of the portal venous system, even though quantitative methods are impractical due to the inability to measure portal flow discrete from hepatic arterial flow, morbidity associated with the use of large volumes of iodinated contrast, and technical limitations. This represents a major disadvantage compared to Doppler ultrasound and magnetic resonance angiography. Qualitative applications include evaluation of portal vein patency, diagnosis of portal vein thrombosis, underlying inflammatory or neoplastic conditions, and evaluation of surgically created portosystemic shunts and collateral flow. Diagnostic criteria for portal venous thrombosis include nonopacification of the central portion of the portal vein, peripheral enhancement of the vein, and irregular periportal hepatic parenchymal enhancement. However, misdiagnosis is common, occurring in 16% of cases analyzed in one limited series, and periportal vein enhancement is now recognized as a nonspecific finding associated with underlying endothelial injury. Cavernous transformation of the portal vein and neoplastic invasion of the portal system are more reliably recognized. Computed tomography arterial portography demonstrates collateral pathways and arteriovenous shunts. Computed tomography has a sensitivity of 85% in detection of esophageal varices compared to endoscopy, but has the advantage of demonstrating splenorenal, gastrorenal, peripancreatic, pericholecystic, retroperitoneal and omental collateral vessels, and spontaneous large portosystemic shunts, with greater sensitivity than angiography. Computed tomography combined with Doppler ultrasound angiography remains popular, despite a lack of large-scale prospective efficacy studies demonstrating diagnostic superiority over other imaging techniques, largely because of its accessibility, and its detailed axial anatomic images providing an overview of multiple organ systems, and patency of major vessels.</description><subject>Biological and medical sciences</subject><subject>Collateral Circulation - physiology</subject><subject>Digestive system</subject><subject>Humans</subject><subject>Hypertension, Portal - diagnostic imaging</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Medical sciences</subject><subject>Portal System - diagnostic imaging</subject><subject>Portal System - physiology</subject><subject>Portal Vein - diagnostic imaging</subject><subject>Portasystemic Shunt, Surgical</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Sensitivity and Specificity</subject><subject>Thrombosis - diagnostic imaging</subject><subject>Tomography, X-Ray Computed</subject><issn>0192-0790</issn><issn>1539-2031</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kUtLAzEQgIMoWqs_QdiDeFvNa7PJsRRfUFDwcQ1pdtauZjc12bX03xtt1ZOBEDLzTWb4glBG8DnBqrzAaXHJRE6UopilW542JTtoRAqm8hQju2iEiaI5LhU-QIcxvmJMSsbIPtonRSE44yM0mfp2OfRQZY--9S_BLBfrrOmyfgHZ5Ydxg-kb32W-_o7c-9Ablz1D54eYPaxjD-0R2quNi3C8Pcfo6erycXqTz-6ub6eTWW6Z5CRn8xoKzgo5txxTIMAqQUsOZSVAcG6xNBRbqqysFa1KZUoy54xUgnFOKGVsjM427y6Dfx8g9rptogXnTAdpGl1SKQohVQLlBrTBxxig1svQtCasNcH6y57-sad_7elve6n0ZNtjmLdQ_RVudKX86TZvojWuDqazTfzFCkqxkEXC-AZbeddDiG9uWEHQCzCuX-j__o59AsGHhLw</recordid><startdate>199203</startdate><enddate>199203</enddate><creator>Taylor, Caroline R</creator><general>Lippincott-Raven Publishers</general><general>Lippincott Williams &amp; Wilkins</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>8BM</scope></search><sort><creationdate>199203</creationdate><title>Computed Tomography in the Evaluation of the Portal Venous System</title><author>Taylor, Caroline R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3841-3bfe54358bc402e1e3d6274e7d6e644c08a20c29c8f92d79a71b431d634412233</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Biological and medical sciences</topic><topic>Collateral Circulation - physiology</topic><topic>Digestive system</topic><topic>Humans</topic><topic>Hypertension, Portal - diagnostic imaging</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Medical sciences</topic><topic>Portal System - diagnostic imaging</topic><topic>Portal System - physiology</topic><topic>Portal Vein - diagnostic imaging</topic><topic>Portasystemic Shunt, Surgical</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Sensitivity and Specificity</topic><topic>Thrombosis - diagnostic imaging</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Taylor, Caroline R</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>ComDisDome</collection><jtitle>Journal of clinical gastroenterology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Taylor, Caroline R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computed Tomography in the Evaluation of the Portal Venous System</atitle><jtitle>Journal of clinical gastroenterology</jtitle><addtitle>J Clin Gastroenterol</addtitle><date>1992-03</date><risdate>1992</risdate><volume>14</volume><issue>2</issue><spage>167</spage><epage>172</epage><pages>167-172</pages><issn>0192-0790</issn><eissn>1539-2031</eissn><coden>JCGADC</coden><abstract>Computed tomography has widespread clinical application in the evaluation of the portal venous system, even though quantitative methods are impractical due to the inability to measure portal flow discrete from hepatic arterial flow, morbidity associated with the use of large volumes of iodinated contrast, and technical limitations. This represents a major disadvantage compared to Doppler ultrasound and magnetic resonance angiography. Qualitative applications include evaluation of portal vein patency, diagnosis of portal vein thrombosis, underlying inflammatory or neoplastic conditions, and evaluation of surgically created portosystemic shunts and collateral flow. Diagnostic criteria for portal venous thrombosis include nonopacification of the central portion of the portal vein, peripheral enhancement of the vein, and irregular periportal hepatic parenchymal enhancement. However, misdiagnosis is common, occurring in 16% of cases analyzed in one limited series, and periportal vein enhancement is now recognized as a nonspecific finding associated with underlying endothelial injury. Cavernous transformation of the portal vein and neoplastic invasion of the portal system are more reliably recognized. Computed tomography arterial portography demonstrates collateral pathways and arteriovenous shunts. Computed tomography has a sensitivity of 85% in detection of esophageal varices compared to endoscopy, but has the advantage of demonstrating splenorenal, gastrorenal, peripancreatic, pericholecystic, retroperitoneal and omental collateral vessels, and spontaneous large portosystemic shunts, with greater sensitivity than angiography. Computed tomography combined with Doppler ultrasound angiography remains popular, despite a lack of large-scale prospective efficacy studies demonstrating diagnostic superiority over other imaging techniques, largely because of its accessibility, and its detailed axial anatomic images providing an overview of multiple organ systems, and patency of major vessels.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott-Raven Publishers</pub><pmid>1556434</pmid><doi>10.1097/00004836-199203000-00021</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0192-0790
ispartof Journal of clinical gastroenterology, 1992-03, Vol.14 (2), p.167-172
issn 0192-0790
1539-2031
language eng
recordid cdi_proquest_miscellaneous_72865689
source MEDLINE; Journals@Ovid Complete
subjects Biological and medical sciences
Collateral Circulation - physiology
Digestive system
Humans
Hypertension, Portal - diagnostic imaging
Investigative techniques, diagnostic techniques (general aspects)
Medical sciences
Portal System - diagnostic imaging
Portal System - physiology
Portal Vein - diagnostic imaging
Portasystemic Shunt, Surgical
Radiodiagnosis. Nmr imagery. Nmr spectrometry
Sensitivity and Specificity
Thrombosis - diagnostic imaging
Tomography, X-Ray Computed
title Computed Tomography in the Evaluation of the Portal Venous System
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T00%3A49%3A39IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computed%20Tomography%20in%20the%20Evaluation%20of%20the%20Portal%20Venous%20System&rft.jtitle=Journal%20of%20clinical%20gastroenterology&rft.au=Taylor,%20Caroline%20R&rft.date=1992-03&rft.volume=14&rft.issue=2&rft.spage=167&rft.epage=172&rft.pages=167-172&rft.issn=0192-0790&rft.eissn=1539-2031&rft.coden=JCGADC&rft_id=info:doi/10.1097/00004836-199203000-00021&rft_dat=%3Cproquest_cross%3E72865689%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72865689&rft_id=info:pmid/1556434&rfr_iscdi=true