Specific determination of bromate in bread by ion chromatography with ICP-MS
A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to...
Gespeichert in:
Veröffentlicht in: | Shokuhin eiseigaku zasshi 2002-12, Vol.43 (6), p.348-351 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 351 |
---|---|
container_issue | 6 |
container_start_page | 348 |
container_title | Shokuhin eiseigaku zasshi |
container_volume | 43 |
creator | Akiyama, T. (National Inst. of Hygienic Sciences, Tokyo (Japan)) Yamanaka, M Date, Y Kubota, H Hamano Nagaoka, M Kawasaki, Y Yamazaki, T Yomota, C Maitani, T |
description | A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 microL sample solution was applied to IC/ICP-MS. The detection limit and the quantitation limit of bromate in the solution were 0.3 ng/mL and 1.0 ng/mL, expressed as HBrO3, respectively, which corresponded to 2 ng/g and 5 ng/g, respectively, in bread. Recovery of bromate was about 90%, and the CV was about 2%. Based on the detection limit in solution and recovery from bread, the detection limit of bromate in bread was estimated to be 2 ng/g. |
doi_str_mv | 10.3358/shokueishi.43.348 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72861598</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72861598</sourcerecordid><originalsourceid>FETCH-LOGICAL-c386t-e8ca805cb02fd0eccf8d036b67435f04a3f5ae115d8479b462b4f713ca9ee383</originalsourceid><addsrcrecordid>eNpFkE1PAjEQhhujEUR_gAfNnrwttjvdUo6G-IHBSAL3ptudslWWYrsbw793ERJOM5n3eefwEHLL6BAgl4-x8t8tuli5IYchcHlG-kzKLGWUinPSp5TlqeCZ6JGrGL-6IwUqL0mPZQJyANEns8UWjbPOJCU2GGq30Y3zm8TbpAi-1g0mbtOtqMuk2CX7yFT_gV8Fva12ya9rqmQ6macfi2tyYfU64s1xDsjy5Xk5eUtnn6_TydMsNSBFk6I0WtLcFDSzJUVjrCwpiEKMOOSWcg0218hYXko-GhdcZAW3IwZGjxFBwoA8HN5ug_9pMTaqdtHgeq036NuoRpkULB_vQXYATfAxBrRqG1ytw04xqvYG1cmg4qA6g13n_vi8LWosT42jsg64OwBWe6VXwUX1Ps9oZ5ZyygX8AXsjeD8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72861598</pqid></control><display><type>article</type><title>Specific determination of bromate in bread by ion chromatography with ICP-MS</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Akiyama, T. (National Inst. of Hygienic Sciences, Tokyo (Japan)) ; Yamanaka, M ; Date, Y ; Kubota, H ; Hamano Nagaoka, M ; Kawasaki, Y ; Yamazaki, T ; Yomota, C ; Maitani, T</creator><creatorcontrib>Akiyama, T. (National Inst. of Hygienic Sciences, Tokyo (Japan)) ; Yamanaka, M ; Date, Y ; Kubota, H ; Hamano Nagaoka, M ; Kawasaki, Y ; Yamazaki, T ; Yomota, C ; Maitani, T</creatorcontrib><description>A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 microL sample solution was applied to IC/ICP-MS. The detection limit and the quantitation limit of bromate in the solution were 0.3 ng/mL and 1.0 ng/mL, expressed as HBrO3, respectively, which corresponded to 2 ng/g and 5 ng/g, respectively, in bread. Recovery of bromate was about 90%, and the CV was about 2%. Based on the detection limit in solution and recovery from bread, the detection limit of bromate in bread was estimated to be 2 ng/g.</description><identifier>ISSN: 0015-6426</identifier><identifier>EISSN: 1882-1006</identifier><identifier>DOI: 10.3358/shokueishi.43.348</identifier><identifier>PMID: 12635336</identifier><language>eng</language><publisher>Japan</publisher><subject>ANALYTICAL METHODS ; BREAD ; Bread - analysis ; BROMATES ; Bromates - analysis ; Chromatography, Ion Exchange - methods ; ION EXCHANGE CHROMATOGRAPHY ; Mass Spectrometry - methods ; Sensitivity and Specificity</subject><ispartof>Shokuhin eiseigaku zasshi, 2002-12, Vol.43 (6), p.348-351</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c386t-e8ca805cb02fd0eccf8d036b67435f04a3f5ae115d8479b462b4f713ca9ee383</citedby><cites>FETCH-LOGICAL-c386t-e8ca805cb02fd0eccf8d036b67435f04a3f5ae115d8479b462b4f713ca9ee383</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12635336$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Akiyama, T. (National Inst. of Hygienic Sciences, Tokyo (Japan))</creatorcontrib><creatorcontrib>Yamanaka, M</creatorcontrib><creatorcontrib>Date, Y</creatorcontrib><creatorcontrib>Kubota, H</creatorcontrib><creatorcontrib>Hamano Nagaoka, M</creatorcontrib><creatorcontrib>Kawasaki, Y</creatorcontrib><creatorcontrib>Yamazaki, T</creatorcontrib><creatorcontrib>Yomota, C</creatorcontrib><creatorcontrib>Maitani, T</creatorcontrib><title>Specific determination of bromate in bread by ion chromatography with ICP-MS</title><title>Shokuhin eiseigaku zasshi</title><addtitle>Shokuhin Eiseigaku Zasshi</addtitle><description>A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 microL sample solution was applied to IC/ICP-MS. The detection limit and the quantitation limit of bromate in the solution were 0.3 ng/mL and 1.0 ng/mL, expressed as HBrO3, respectively, which corresponded to 2 ng/g and 5 ng/g, respectively, in bread. Recovery of bromate was about 90%, and the CV was about 2%. Based on the detection limit in solution and recovery from bread, the detection limit of bromate in bread was estimated to be 2 ng/g.</description><subject>ANALYTICAL METHODS</subject><subject>BREAD</subject><subject>Bread - analysis</subject><subject>BROMATES</subject><subject>Bromates - analysis</subject><subject>Chromatography, Ion Exchange - methods</subject><subject>ION EXCHANGE CHROMATOGRAPHY</subject><subject>Mass Spectrometry - methods</subject><subject>Sensitivity and Specificity</subject><issn>0015-6426</issn><issn>1882-1006</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkE1PAjEQhhujEUR_gAfNnrwttjvdUo6G-IHBSAL3ptudslWWYrsbw793ERJOM5n3eefwEHLL6BAgl4-x8t8tuli5IYchcHlG-kzKLGWUinPSp5TlqeCZ6JGrGL-6IwUqL0mPZQJyANEns8UWjbPOJCU2GGq30Y3zm8TbpAi-1g0mbtOtqMuk2CX7yFT_gV8Fva12ya9rqmQ6macfi2tyYfU64s1xDsjy5Xk5eUtnn6_TydMsNSBFk6I0WtLcFDSzJUVjrCwpiEKMOOSWcg0218hYXko-GhdcZAW3IwZGjxFBwoA8HN5ug_9pMTaqdtHgeq036NuoRpkULB_vQXYATfAxBrRqG1ytw04xqvYG1cmg4qA6g13n_vi8LWosT42jsg64OwBWe6VXwUX1Ps9oZ5ZyygX8AXsjeD8</recordid><startdate>20021201</startdate><enddate>20021201</enddate><creator>Akiyama, T. (National Inst. of Hygienic Sciences, Tokyo (Japan))</creator><creator>Yamanaka, M</creator><creator>Date, Y</creator><creator>Kubota, H</creator><creator>Hamano Nagaoka, M</creator><creator>Kawasaki, Y</creator><creator>Yamazaki, T</creator><creator>Yomota, C</creator><creator>Maitani, T</creator><scope>FBQ</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20021201</creationdate><title>Specific determination of bromate in bread by ion chromatography with ICP-MS</title><author>Akiyama, T. (National Inst. of Hygienic Sciences, Tokyo (Japan)) ; Yamanaka, M ; Date, Y ; Kubota, H ; Hamano Nagaoka, M ; Kawasaki, Y ; Yamazaki, T ; Yomota, C ; Maitani, T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c386t-e8ca805cb02fd0eccf8d036b67435f04a3f5ae115d8479b462b4f713ca9ee383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>ANALYTICAL METHODS</topic><topic>BREAD</topic><topic>Bread - analysis</topic><topic>BROMATES</topic><topic>Bromates - analysis</topic><topic>Chromatography, Ion Exchange - methods</topic><topic>ION EXCHANGE CHROMATOGRAPHY</topic><topic>Mass Spectrometry - methods</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Akiyama, T. (National Inst. of Hygienic Sciences, Tokyo (Japan))</creatorcontrib><creatorcontrib>Yamanaka, M</creatorcontrib><creatorcontrib>Date, Y</creatorcontrib><creatorcontrib>Kubota, H</creatorcontrib><creatorcontrib>Hamano Nagaoka, M</creatorcontrib><creatorcontrib>Kawasaki, Y</creatorcontrib><creatorcontrib>Yamazaki, T</creatorcontrib><creatorcontrib>Yomota, C</creatorcontrib><creatorcontrib>Maitani, T</creatorcontrib><collection>AGRIS</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Shokuhin eiseigaku zasshi</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Akiyama, T. (National Inst. of Hygienic Sciences, Tokyo (Japan))</au><au>Yamanaka, M</au><au>Date, Y</au><au>Kubota, H</au><au>Hamano Nagaoka, M</au><au>Kawasaki, Y</au><au>Yamazaki, T</au><au>Yomota, C</au><au>Maitani, T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Specific determination of bromate in bread by ion chromatography with ICP-MS</atitle><jtitle>Shokuhin eiseigaku zasshi</jtitle><addtitle>Shokuhin Eiseigaku Zasshi</addtitle><date>2002-12-01</date><risdate>2002</risdate><volume>43</volume><issue>6</issue><spage>348</spage><epage>351</epage><pages>348-351</pages><issn>0015-6426</issn><eissn>1882-1006</eissn><abstract>A sensitive method for detecting bromate in bread by ion chromatography with inductively-coupled plasma mass spectrometry (IC/ICP-MS) was developed. Bromate was extracted from bread with water. The clean-up procedure included a 0.2 micron filter, a C18 cartridge for defatting, a silver cartridge to remove halogen anions, a centrifugal ultrafiltration unit to remove proteins, and a cation-exchange cartridge to remove silver ions. A 500 microL sample solution was applied to IC/ICP-MS. The detection limit and the quantitation limit of bromate in the solution were 0.3 ng/mL and 1.0 ng/mL, expressed as HBrO3, respectively, which corresponded to 2 ng/g and 5 ng/g, respectively, in bread. Recovery of bromate was about 90%, and the CV was about 2%. Based on the detection limit in solution and recovery from bread, the detection limit of bromate in bread was estimated to be 2 ng/g.</abstract><cop>Japan</cop><pmid>12635336</pmid><doi>10.3358/shokueishi.43.348</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0015-6426 |
ispartof | Shokuhin eiseigaku zasshi, 2002-12, Vol.43 (6), p.348-351 |
issn | 0015-6426 1882-1006 |
language | eng |
recordid | cdi_proquest_miscellaneous_72861598 |
source | MEDLINE; EZB-FREE-00999 freely available EZB journals |
subjects | ANALYTICAL METHODS BREAD Bread - analysis BROMATES Bromates - analysis Chromatography, Ion Exchange - methods ION EXCHANGE CHROMATOGRAPHY Mass Spectrometry - methods Sensitivity and Specificity |
title | Specific determination of bromate in bread by ion chromatography with ICP-MS |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T18%3A42%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Specific%20determination%20of%20bromate%20in%20bread%20by%20ion%20chromatography%20with%20ICP-MS&rft.jtitle=Shokuhin%20eiseigaku%20zasshi&rft.au=Akiyama,%20T.%20(National%20Inst.%20of%20Hygienic%20Sciences,%20Tokyo%20(Japan))&rft.date=2002-12-01&rft.volume=43&rft.issue=6&rft.spage=348&rft.epage=351&rft.pages=348-351&rft.issn=0015-6426&rft.eissn=1882-1006&rft_id=info:doi/10.3358/shokueishi.43.348&rft_dat=%3Cproquest_cross%3E72861598%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72861598&rft_id=info:pmid/12635336&rfr_iscdi=true |