Titanium hip implants for improved magnetic resonance and computed tomography examinations
The value of magnetic resonance imaging (MRI) for assessment of the hip has been demonstrated, particularly in cases of avascular necrosis. Magnetic resonance imaging can be used to provide anatomic evaluation of the femoral head, acetabulum, hip joint, joint fluid, and the surrounding structures. M...
Gespeichert in:
Veröffentlicht in: | Clinical orthopaedics and related research 1992-02, Vol.275 (275), p.194-198 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 198 |
---|---|
container_issue | 275 |
container_start_page | 194 |
container_title | Clinical orthopaedics and related research |
container_volume | 275 |
creator | EBRAHEIM, N. A SAVOLAINE, E. R ZEISS, J THOMAS JACKSON, W |
description | The value of magnetic resonance imaging (MRI) for assessment of the hip has been demonstrated, particularly in cases of avascular necrosis. Magnetic resonance imaging can be used to provide anatomic evaluation of the femoral head, acetabulum, hip joint, joint fluid, and the surrounding structures. MR examinations of two patients with hip fractures fixed with stainless steel hip implants were compared with nine patients with hip fractures fixed with titanium hip implants, one of which showed avascular necrosis of the femoral head. The titanium implants resulted in less MRI artifacts, allowing for improved depiction of the femoral head and surrounding soft tissue. For this reason titanium fixation devices are recommended as a substitute for stainless steel in the hip joint region in a patient who may need future MR examination. |
doi_str_mv | 10.1097/00003086-199202000-00028 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72791186</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72791186</sourcerecordid><originalsourceid>FETCH-LOGICAL-c436t-9139550998f270774261d9865f45c1c98fcce78d241a2e8108d6cfc184b80c173</originalsourceid><addsrcrecordid>eNqFkEtLAzEUhYMotVZ_gpCFuBvNvfNKllJ8geCmgrgZ0kymjTSTMZkR--9Nba1LAyHce85Jcj9CKLArYKK8ZnGljBcJCIEMY5XEjfyAjCFHngCkeEjGsScSgfB6TE5CeN-EshxHZARlmiOkY_I2M71szWDp0nTU2G4l2z7QxvlN4d2nrqmVi1b3RlGvg2tlqzSVbU2Vs93QR7131i287JZrqr-kNa3sjWvDKTlq5Cros905IS93t7PpQ_L0fP84vXlKVJYWfSIgFXnOhOANlqwsMyygFrzImyxXoGJbKV3yGjOQqDkwXheqUcCzOWcqDjIhl9t743c_Bh36ypqg9CpOot0QqhJLAcCLf41QoIheFo18a1TeheB1U3XeWOnXFbBqw7_65V_t-Vc__GP0fPfGMLe6_gtugUf9YqfLoOSq8RGnCXtbjogiS9Nv12-NOw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>16292790</pqid></control><display><type>article</type><title>Titanium hip implants for improved magnetic resonance and computed tomography examinations</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>EBRAHEIM, N. A ; SAVOLAINE, E. R ; ZEISS, J ; THOMAS JACKSON, W</creator><creatorcontrib>EBRAHEIM, N. A ; SAVOLAINE, E. R ; ZEISS, J ; THOMAS JACKSON, W</creatorcontrib><description>The value of magnetic resonance imaging (MRI) for assessment of the hip has been demonstrated, particularly in cases of avascular necrosis. Magnetic resonance imaging can be used to provide anatomic evaluation of the femoral head, acetabulum, hip joint, joint fluid, and the surrounding structures. MR examinations of two patients with hip fractures fixed with stainless steel hip implants were compared with nine patients with hip fractures fixed with titanium hip implants, one of which showed avascular necrosis of the femoral head. The titanium implants resulted in less MRI artifacts, allowing for improved depiction of the femoral head and surrounding soft tissue. For this reason titanium fixation devices are recommended as a substitute for stainless steel in the hip joint region in a patient who may need future MR examination.</description><identifier>ISSN: 0009-921X</identifier><identifier>EISSN: 1528-1132</identifier><identifier>DOI: 10.1097/00003086-199202000-00028</identifier><identifier>PMID: 1735213</identifier><identifier>CODEN: CORTBR</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Biological and medical sciences ; Bone Nails ; Bone Plates ; Bone Screws ; Femur Head Necrosis - diagnosis ; Femur Head Necrosis - surgery ; Hip Fractures - surgery ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Magnetic Resonance Imaging ; Materials Testing ; Medical sciences ; Osteoarticular system. Muscles ; Prostheses and Implants ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Stainless Steel ; Titanium ; Tomography, X-Ray Computed</subject><ispartof>Clinical orthopaedics and related research, 1992-02, Vol.275 (275), p.194-198</ispartof><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c436t-9139550998f270774261d9865f45c1c98fcce78d241a2e8108d6cfc184b80c173</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=5222943$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1735213$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>EBRAHEIM, N. A</creatorcontrib><creatorcontrib>SAVOLAINE, E. R</creatorcontrib><creatorcontrib>ZEISS, J</creatorcontrib><creatorcontrib>THOMAS JACKSON, W</creatorcontrib><title>Titanium hip implants for improved magnetic resonance and computed tomography examinations</title><title>Clinical orthopaedics and related research</title><addtitle>Clin Orthop Relat Res</addtitle><description>The value of magnetic resonance imaging (MRI) for assessment of the hip has been demonstrated, particularly in cases of avascular necrosis. Magnetic resonance imaging can be used to provide anatomic evaluation of the femoral head, acetabulum, hip joint, joint fluid, and the surrounding structures. MR examinations of two patients with hip fractures fixed with stainless steel hip implants were compared with nine patients with hip fractures fixed with titanium hip implants, one of which showed avascular necrosis of the femoral head. The titanium implants resulted in less MRI artifacts, allowing for improved depiction of the femoral head and surrounding soft tissue. For this reason titanium fixation devices are recommended as a substitute for stainless steel in the hip joint region in a patient who may need future MR examination.</description><subject>Biological and medical sciences</subject><subject>Bone Nails</subject><subject>Bone Plates</subject><subject>Bone Screws</subject><subject>Femur Head Necrosis - diagnosis</subject><subject>Femur Head Necrosis - surgery</subject><subject>Hip Fractures - surgery</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Magnetic Resonance Imaging</subject><subject>Materials Testing</subject><subject>Medical sciences</subject><subject>Osteoarticular system. Muscles</subject><subject>Prostheses and Implants</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Stainless Steel</subject><subject>Titanium</subject><subject>Tomography, X-Ray Computed</subject><issn>0009-921X</issn><issn>1528-1132</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkEtLAzEUhYMotVZ_gpCFuBvNvfNKllJ8geCmgrgZ0kymjTSTMZkR--9Nba1LAyHce85Jcj9CKLArYKK8ZnGljBcJCIEMY5XEjfyAjCFHngCkeEjGsScSgfB6TE5CeN-EshxHZARlmiOkY_I2M71szWDp0nTU2G4l2z7QxvlN4d2nrqmVi1b3RlGvg2tlqzSVbU2Vs93QR7131i287JZrqr-kNa3sjWvDKTlq5Cros905IS93t7PpQ_L0fP84vXlKVJYWfSIgFXnOhOANlqwsMyygFrzImyxXoGJbKV3yGjOQqDkwXheqUcCzOWcqDjIhl9t743c_Bh36ypqg9CpOot0QqhJLAcCLf41QoIheFo18a1TeheB1U3XeWOnXFbBqw7_65V_t-Vc__GP0fPfGMLe6_gtugUf9YqfLoOSq8RGnCXtbjogiS9Nv12-NOw</recordid><startdate>19920201</startdate><enddate>19920201</enddate><creator>EBRAHEIM, N. A</creator><creator>SAVOLAINE, E. R</creator><creator>ZEISS, J</creator><creator>THOMAS JACKSON, W</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QP</scope><scope>7X8</scope></search><sort><creationdate>19920201</creationdate><title>Titanium hip implants for improved magnetic resonance and computed tomography examinations</title><author>EBRAHEIM, N. A ; SAVOLAINE, E. R ; ZEISS, J ; THOMAS JACKSON, W</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c436t-9139550998f270774261d9865f45c1c98fcce78d241a2e8108d6cfc184b80c173</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Biological and medical sciences</topic><topic>Bone Nails</topic><topic>Bone Plates</topic><topic>Bone Screws</topic><topic>Femur Head Necrosis - diagnosis</topic><topic>Femur Head Necrosis - surgery</topic><topic>Hip Fractures - surgery</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Magnetic Resonance Imaging</topic><topic>Materials Testing</topic><topic>Medical sciences</topic><topic>Osteoarticular system. Muscles</topic><topic>Prostheses and Implants</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Stainless Steel</topic><topic>Titanium</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>EBRAHEIM, N. A</creatorcontrib><creatorcontrib>SAVOLAINE, E. R</creatorcontrib><creatorcontrib>ZEISS, J</creatorcontrib><creatorcontrib>THOMAS JACKSON, W</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Calcium & Calcified Tissue Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Clinical orthopaedics and related research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>EBRAHEIM, N. A</au><au>SAVOLAINE, E. R</au><au>ZEISS, J</au><au>THOMAS JACKSON, W</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Titanium hip implants for improved magnetic resonance and computed tomography examinations</atitle><jtitle>Clinical orthopaedics and related research</jtitle><addtitle>Clin Orthop Relat Res</addtitle><date>1992-02-01</date><risdate>1992</risdate><volume>275</volume><issue>275</issue><spage>194</spage><epage>198</epage><pages>194-198</pages><issn>0009-921X</issn><eissn>1528-1132</eissn><coden>CORTBR</coden><abstract>The value of magnetic resonance imaging (MRI) for assessment of the hip has been demonstrated, particularly in cases of avascular necrosis. Magnetic resonance imaging can be used to provide anatomic evaluation of the femoral head, acetabulum, hip joint, joint fluid, and the surrounding structures. MR examinations of two patients with hip fractures fixed with stainless steel hip implants were compared with nine patients with hip fractures fixed with titanium hip implants, one of which showed avascular necrosis of the femoral head. The titanium implants resulted in less MRI artifacts, allowing for improved depiction of the femoral head and surrounding soft tissue. For this reason titanium fixation devices are recommended as a substitute for stainless steel in the hip joint region in a patient who may need future MR examination.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>1735213</pmid><doi>10.1097/00003086-199202000-00028</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-921X |
ispartof | Clinical orthopaedics and related research, 1992-02, Vol.275 (275), p.194-198 |
issn | 0009-921X 1528-1132 |
language | eng |
recordid | cdi_proquest_miscellaneous_72791186 |
source | MEDLINE; Journals@Ovid Complete |
subjects | Biological and medical sciences Bone Nails Bone Plates Bone Screws Femur Head Necrosis - diagnosis Femur Head Necrosis - surgery Hip Fractures - surgery Humans Investigative techniques, diagnostic techniques (general aspects) Magnetic Resonance Imaging Materials Testing Medical sciences Osteoarticular system. Muscles Prostheses and Implants Radiodiagnosis. Nmr imagery. Nmr spectrometry Stainless Steel Titanium Tomography, X-Ray Computed |
title | Titanium hip implants for improved magnetic resonance and computed tomography examinations |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T03%3A21%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Titanium%20hip%20implants%20for%20improved%20magnetic%20resonance%20and%20computed%20tomography%20examinations&rft.jtitle=Clinical%20orthopaedics%20and%20related%20research&rft.au=EBRAHEIM,%20N.%20A&rft.date=1992-02-01&rft.volume=275&rft.issue=275&rft.spage=194&rft.epage=198&rft.pages=194-198&rft.issn=0009-921X&rft.eissn=1528-1132&rft.coden=CORTBR&rft_id=info:doi/10.1097/00003086-199202000-00028&rft_dat=%3Cproquest_cross%3E72791186%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=16292790&rft_id=info:pmid/1735213&rfr_iscdi=true |