Response time of pulse oximeters assessed using acute decompression

In human volunteers, the response times of 11 pulse oximeters to a 10% step reduction in arterial oxygen saturation were measured using an acute decompression technique. When finger probes were used, nine oximeters had similar response times and two were significantly slower (P less than 0.05). The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anesthesia and analgesia 1992-02, Vol.74 (2), p.189-195
Hauptverfasser: YOUNG, D, JEWKES, C, SPITTAL, M, BLOGG, C, WEISSMAN, J, GRADWELL, D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 195
container_issue 2
container_start_page 189
container_title Anesthesia and analgesia
container_volume 74
creator YOUNG, D
JEWKES, C
SPITTAL, M
BLOGG, C
WEISSMAN, J
GRADWELL, D
description In human volunteers, the response times of 11 pulse oximeters to a 10% step reduction in arterial oxygen saturation were measured using an acute decompression technique. When finger probes were used, nine oximeters had similar response times and two were significantly slower (P less than 0.05). The ear probe response time was similar on six oximeters assessed, and faster than the finger probes. The response times of the oximeters to an acute increase in arterial saturation were tested by suddenly changing the inspired gas from air to 100% oxygen at an ambient pressure of 380 mm Hg. For ear probes, the response times were similar for all oximeters; for finger probes, three fast-responding and three slow-responding oximeters were identified (P less than 0.05). A faster response could be elicited by placing the probes on the thumb (P less than 0.05). We conclude that if a rapid indication of changes in arterial saturation is required, pulse oximeters with ear probes should be used. If finger probes are used, they should be placed on the thumb. The oximeter used will influence the response time if finger probes are used, but it will have little effect if ear probes are used.
doi_str_mv 10.1213/00000539-199202000-00003
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72787738</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72787738</sourcerecordid><originalsourceid>FETCH-LOGICAL-c389t-a71190a6b4a0d3ed047e5b69dd61891ebed6de02450b86e68e06dfa2ab69325f3</originalsourceid><addsrcrecordid>eNpFUNlKxDAUDaKM4-gnCHkQ36JZJtujDG4wIIg-l7S5lUrb1KQF_XtTZ9RL4HK2GzgIYUavGGfims4jhSXMWk55BmRmxAFaMskV0dKaQ7ScKcKttcfoJKX3DBk1aoEWTAsmhVqizTOkIfQJ8Nh0gEONh6nNKHxmOEJM2KUE-Xk8paZ_w66aRsAeqtANMQtN6E_RUe1y6Gy_V-j17vZl80C2T_ePm5stqYSxI3GaMUudKteOegGerjXIUlnvFTOWQQleeaB8LWlpFCgDVPnacZc9gstarNDl7u4Qw8cEaSy6JlXQtq6HMKVCc220FiYbzc5YxZBShLoYYtO5-FUwWsz9Fb_9FX_9_VAiR8_3f0xlB_4_uCss6xd73aXKtXV0fdWkP5tkVFvKxDfuuXgm</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72787738</pqid></control><display><type>article</type><title>Response time of pulse oximeters assessed using acute decompression</title><source>MEDLINE</source><source>Journals@Ovid LWW Legacy Archive</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Journals@Ovid Complete</source><creator>YOUNG, D ; JEWKES, C ; SPITTAL, M ; BLOGG, C ; WEISSMAN, J ; GRADWELL, D</creator><creatorcontrib>YOUNG, D ; JEWKES, C ; SPITTAL, M ; BLOGG, C ; WEISSMAN, J ; GRADWELL, D</creatorcontrib><description>In human volunteers, the response times of 11 pulse oximeters to a 10% step reduction in arterial oxygen saturation were measured using an acute decompression technique. When finger probes were used, nine oximeters had similar response times and two were significantly slower (P less than 0.05). The ear probe response time was similar on six oximeters assessed, and faster than the finger probes. The response times of the oximeters to an acute increase in arterial saturation were tested by suddenly changing the inspired gas from air to 100% oxygen at an ambient pressure of 380 mm Hg. For ear probes, the response times were similar for all oximeters; for finger probes, three fast-responding and three slow-responding oximeters were identified (P less than 0.05). A faster response could be elicited by placing the probes on the thumb (P less than 0.05). We conclude that if a rapid indication of changes in arterial saturation is required, pulse oximeters with ear probes should be used. If finger probes are used, they should be placed on the thumb. The oximeter used will influence the response time if finger probes are used, but it will have little effect if ear probes are used.</description><identifier>ISSN: 0003-2999</identifier><identifier>EISSN: 1526-7598</identifier><identifier>DOI: 10.1213/00000539-199202000-00003</identifier><identifier>PMID: 1731536</identifier><identifier>CODEN: AACRAT</identifier><language>eng</language><publisher>Hagerstown, MD: Lippincott</publisher><subject>Adult ; Anesthesia ; Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Biological and medical sciences ; Decompression ; Ear ; Evaluation Studies as Topic ; Fingers ; General anesthesia. Technics. Complications. Neuromuscular blocking. Premedication. Surgical preparation. Sedation ; Humans ; Male ; Medical sciences ; Oximetry - instrumentation ; Space life sciences ; Time Factors</subject><ispartof>Anesthesia and analgesia, 1992-02, Vol.74 (2), p.189-195</ispartof><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c389t-a71190a6b4a0d3ed047e5b69dd61891ebed6de02450b86e68e06dfa2ab69325f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=5107901$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1731536$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>YOUNG, D</creatorcontrib><creatorcontrib>JEWKES, C</creatorcontrib><creatorcontrib>SPITTAL, M</creatorcontrib><creatorcontrib>BLOGG, C</creatorcontrib><creatorcontrib>WEISSMAN, J</creatorcontrib><creatorcontrib>GRADWELL, D</creatorcontrib><title>Response time of pulse oximeters assessed using acute decompression</title><title>Anesthesia and analgesia</title><addtitle>Anesth Analg</addtitle><description>In human volunteers, the response times of 11 pulse oximeters to a 10% step reduction in arterial oxygen saturation were measured using an acute decompression technique. When finger probes were used, nine oximeters had similar response times and two were significantly slower (P less than 0.05). The ear probe response time was similar on six oximeters assessed, and faster than the finger probes. The response times of the oximeters to an acute increase in arterial saturation were tested by suddenly changing the inspired gas from air to 100% oxygen at an ambient pressure of 380 mm Hg. For ear probes, the response times were similar for all oximeters; for finger probes, three fast-responding and three slow-responding oximeters were identified (P less than 0.05). A faster response could be elicited by placing the probes on the thumb (P less than 0.05). We conclude that if a rapid indication of changes in arterial saturation is required, pulse oximeters with ear probes should be used. If finger probes are used, they should be placed on the thumb. The oximeter used will influence the response time if finger probes are used, but it will have little effect if ear probes are used.</description><subject>Adult</subject><subject>Anesthesia</subject><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Biological and medical sciences</subject><subject>Decompression</subject><subject>Ear</subject><subject>Evaluation Studies as Topic</subject><subject>Fingers</subject><subject>General anesthesia. Technics. Complications. Neuromuscular blocking. Premedication. Surgical preparation. Sedation</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Oximetry - instrumentation</subject><subject>Space life sciences</subject><subject>Time Factors</subject><issn>0003-2999</issn><issn>1526-7598</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFUNlKxDAUDaKM4-gnCHkQ36JZJtujDG4wIIg-l7S5lUrb1KQF_XtTZ9RL4HK2GzgIYUavGGfims4jhSXMWk55BmRmxAFaMskV0dKaQ7ScKcKttcfoJKX3DBk1aoEWTAsmhVqizTOkIfQJ8Nh0gEONh6nNKHxmOEJM2KUE-Xk8paZ_w66aRsAeqtANMQtN6E_RUe1y6Gy_V-j17vZl80C2T_ePm5stqYSxI3GaMUudKteOegGerjXIUlnvFTOWQQleeaB8LWlpFCgDVPnacZc9gstarNDl7u4Qw8cEaSy6JlXQtq6HMKVCc220FiYbzc5YxZBShLoYYtO5-FUwWsz9Fb_9FX_9_VAiR8_3f0xlB_4_uCss6xd73aXKtXV0fdWkP5tkVFvKxDfuuXgm</recordid><startdate>19920201</startdate><enddate>19920201</enddate><creator>YOUNG, D</creator><creator>JEWKES, C</creator><creator>SPITTAL, M</creator><creator>BLOGG, C</creator><creator>WEISSMAN, J</creator><creator>GRADWELL, D</creator><general>Lippincott</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19920201</creationdate><title>Response time of pulse oximeters assessed using acute decompression</title><author>YOUNG, D ; JEWKES, C ; SPITTAL, M ; BLOGG, C ; WEISSMAN, J ; GRADWELL, D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c389t-a71190a6b4a0d3ed047e5b69dd61891ebed6de02450b86e68e06dfa2ab69325f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Adult</topic><topic>Anesthesia</topic><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Biological and medical sciences</topic><topic>Decompression</topic><topic>Ear</topic><topic>Evaluation Studies as Topic</topic><topic>Fingers</topic><topic>General anesthesia. Technics. Complications. Neuromuscular blocking. Premedication. Surgical preparation. Sedation</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Oximetry - instrumentation</topic><topic>Space life sciences</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>YOUNG, D</creatorcontrib><creatorcontrib>JEWKES, C</creatorcontrib><creatorcontrib>SPITTAL, M</creatorcontrib><creatorcontrib>BLOGG, C</creatorcontrib><creatorcontrib>WEISSMAN, J</creatorcontrib><creatorcontrib>GRADWELL, D</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Anesthesia and analgesia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>YOUNG, D</au><au>JEWKES, C</au><au>SPITTAL, M</au><au>BLOGG, C</au><au>WEISSMAN, J</au><au>GRADWELL, D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Response time of pulse oximeters assessed using acute decompression</atitle><jtitle>Anesthesia and analgesia</jtitle><addtitle>Anesth Analg</addtitle><date>1992-02-01</date><risdate>1992</risdate><volume>74</volume><issue>2</issue><spage>189</spage><epage>195</epage><pages>189-195</pages><issn>0003-2999</issn><eissn>1526-7598</eissn><coden>AACRAT</coden><abstract>In human volunteers, the response times of 11 pulse oximeters to a 10% step reduction in arterial oxygen saturation were measured using an acute decompression technique. When finger probes were used, nine oximeters had similar response times and two were significantly slower (P less than 0.05). The ear probe response time was similar on six oximeters assessed, and faster than the finger probes. The response times of the oximeters to an acute increase in arterial saturation were tested by suddenly changing the inspired gas from air to 100% oxygen at an ambient pressure of 380 mm Hg. For ear probes, the response times were similar for all oximeters; for finger probes, three fast-responding and three slow-responding oximeters were identified (P less than 0.05). A faster response could be elicited by placing the probes on the thumb (P less than 0.05). We conclude that if a rapid indication of changes in arterial saturation is required, pulse oximeters with ear probes should be used. If finger probes are used, they should be placed on the thumb. The oximeter used will influence the response time if finger probes are used, but it will have little effect if ear probes are used.</abstract><cop>Hagerstown, MD</cop><pub>Lippincott</pub><pmid>1731536</pmid><doi>10.1213/00000539-199202000-00003</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0003-2999
ispartof Anesthesia and analgesia, 1992-02, Vol.74 (2), p.189-195
issn 0003-2999
1526-7598
language eng
recordid cdi_proquest_miscellaneous_72787738
source MEDLINE; Journals@Ovid LWW Legacy Archive; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Journals@Ovid Complete
subjects Adult
Anesthesia
Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
Biological and medical sciences
Decompression
Ear
Evaluation Studies as Topic
Fingers
General anesthesia. Technics. Complications. Neuromuscular blocking. Premedication. Surgical preparation. Sedation
Humans
Male
Medical sciences
Oximetry - instrumentation
Space life sciences
Time Factors
title Response time of pulse oximeters assessed using acute decompression
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T01%3A59%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Response%20time%20of%20pulse%20oximeters%20assessed%20using%20acute%20decompression&rft.jtitle=Anesthesia%20and%20analgesia&rft.au=YOUNG,%20D&rft.date=1992-02-01&rft.volume=74&rft.issue=2&rft.spage=189&rft.epage=195&rft.pages=189-195&rft.issn=0003-2999&rft.eissn=1526-7598&rft.coden=AACRAT&rft_id=info:doi/10.1213/00000539-199202000-00003&rft_dat=%3Cproquest_cross%3E72787738%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72787738&rft_id=info:pmid/1731536&rfr_iscdi=true