Gross Variability in the Detection of Prolactin in Sera Containing Big Big Prolactin (Macroprolactin) by Commercial Immunoassays
A high molecular mass form of prolactin (PRL), macroprolactin, accumulates in the sera of some subjects. Although macroprolactin exhibits limited bioactivity in vivo, it retains immunoreactivity. We examined the frequency of macroprolactinemia in clinical practice and the ability of immunoassay syst...
Gespeichert in:
Veröffentlicht in: | The journal of clinical endocrinology and metabolism 2002-12, Vol.87 (12), p.5410-5415 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 5415 |
---|---|
container_issue | 12 |
container_start_page | 5410 |
container_title | The journal of clinical endocrinology and metabolism |
container_volume | 87 |
creator | Smith, Thomas P. Suliman, Abdulwahab M. Fahie-Wilson, Michael N. McKenna, T. Joseph |
description | A high molecular mass form of prolactin (PRL), macroprolactin, accumulates in the sera of some subjects. Although macroprolactin exhibits limited bioactivity in vivo, it retains immunoreactivity. We examined the frequency of macroprolactinemia in clinical practice and the ability of immunoassay systems to distinguish between macroprolactin and monomeric PRL. Of 300 hyperprolactinemic sera identified, 71 normalized following treatment of sera with polyethylene glycol, indicating that 24% of hyperprolactinemia could be accounted for by macroprolactin. Ten of these macroprolactinemic sera were circulated to 18 clinical laboratories. Two sets of PRL measurements of the 10 untreated sera were obtained from each of the nine most commonly used immunoassay systems. Across the nine assay systems, differences in the PRL estimates ranged from 2.3- to 7.8-fold. Elecsys users reported the highest PRL levels. Somewhat lower values were reported for DELFIA systems followed by Immuno-1, AxSYM, and Architect assays. The Immulite 2000 assay generated PRL levels equivalent to approximately 50% of those reported by the high-reading methods. The lowest PRL levels were reported by Access, ACS:180, and Centaur systems. To avoid confusion caused by the frequent presence of macroprolactin accounting for hyperprolactinemia, secondary screening for the presence of macroprolactin is recommended. |
doi_str_mv | 10.1210/jc.2001-011943 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72757759</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72757759</sourcerecordid><originalsourceid>FETCH-LOGICAL-c473t-3e7ede05625d85793219ea70f6242ef6de70d5faba45c09a43608a8bfe0adf883</originalsourceid><addsrcrecordid>eNp1kE1v1DAQhi1ERbctV47IF1A5ZLEdO06OZYG2UhFIfIhbNHHG4FViL3Zy2Ft_Ol5l0Z44jEajeWb06iHkBWdrLjh7uzVrwRgvGOeNLJ-QVW6q0LzRT8mKMcGLRouf5-QipW3mpFTlM3LOhayqUugVebyNISX6A6KDzg1u2lPn6fQb6Xuc0EwueBos_RLDAHnyh-1XjEA3wU_gvPO_6Du31Am6_gQmht2_-Q3t9vlgHDEaBwO9H8fZB0gJ9umKnFkYEj4_9kvy_eOHb5u74uHz7f3m5qEwUpdTUaLGHpmqhOprpZtS8AZBM1sJKdBWPWrWKwsdSGVYA7KsWA11Z5FBb-u6vCSvl7851Z8Z09SOLhkcBvAY5tRqoZXWqsngegHNwUxE2-6iGyHuW87ag_N2a9qD83Zxng9eHj_P3Yj9CT9KzsCrIwDJwGAjeOPSiZNScKVU5tTCoe-Dic7jLmJK7TbM0Wc3_wvwF89TnIc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72757759</pqid></control><display><type>article</type><title>Gross Variability in the Detection of Prolactin in Sera Containing Big Big Prolactin (Macroprolactin) by Commercial Immunoassays</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Oxford University Press Journals All Titles (1996-Current)</source><creator>Smith, Thomas P. ; Suliman, Abdulwahab M. ; Fahie-Wilson, Michael N. ; McKenna, T. Joseph</creator><creatorcontrib>Smith, Thomas P. ; Suliman, Abdulwahab M. ; Fahie-Wilson, Michael N. ; McKenna, T. Joseph</creatorcontrib><description>A high molecular mass form of prolactin (PRL), macroprolactin, accumulates in the sera of some subjects. Although macroprolactin exhibits limited bioactivity in vivo, it retains immunoreactivity. We examined the frequency of macroprolactinemia in clinical practice and the ability of immunoassay systems to distinguish between macroprolactin and monomeric PRL. Of 300 hyperprolactinemic sera identified, 71 normalized following treatment of sera with polyethylene glycol, indicating that 24% of hyperprolactinemia could be accounted for by macroprolactin. Ten of these macroprolactinemic sera were circulated to 18 clinical laboratories. Two sets of PRL measurements of the 10 untreated sera were obtained from each of the nine most commonly used immunoassay systems. Across the nine assay systems, differences in the PRL estimates ranged from 2.3- to 7.8-fold. Elecsys users reported the highest PRL levels. Somewhat lower values were reported for DELFIA systems followed by Immuno-1, AxSYM, and Architect assays. The Immulite 2000 assay generated PRL levels equivalent to approximately 50% of those reported by the high-reading methods. The lowest PRL levels were reported by Access, ACS:180, and Centaur systems. To avoid confusion caused by the frequent presence of macroprolactin accounting for hyperprolactinemia, secondary screening for the presence of macroprolactin is recommended.</description><identifier>ISSN: 0021-972X</identifier><identifier>EISSN: 1945-7197</identifier><identifier>DOI: 10.1210/jc.2001-011943</identifier><identifier>PMID: 12466327</identifier><identifier>CODEN: JCEMAZ</identifier><language>eng</language><publisher>Bethesda, MD: Endocrine Society</publisher><subject>Adult ; Biological and medical sciences ; Chromatography, Gel ; Endocrinology ; Female ; Fundamental and applied biological sciences. Psychology ; Hormones and neuropeptides. Regulation ; Humans ; Hyperprolactinemia - blood ; Hypothalamus. Hypophysis. Epiphysis. Urophysis ; Immunoassay - methods ; Immunoassay - standards ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Medical sciences ; Middle Aged ; Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques ; Polyethylene Glycols - pharmacology ; Prolactin - blood ; Solvents - pharmacology ; Vertebrates: endocrinology</subject><ispartof>The journal of clinical endocrinology and metabolism, 2002-12, Vol.87 (12), p.5410-5415</ispartof><rights>2003 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c473t-3e7ede05625d85793219ea70f6242ef6de70d5faba45c09a43608a8bfe0adf883</citedby><cites>FETCH-LOGICAL-c473t-3e7ede05625d85793219ea70f6242ef6de70d5faba45c09a43608a8bfe0adf883</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=14421555$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12466327$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Smith, Thomas P.</creatorcontrib><creatorcontrib>Suliman, Abdulwahab M.</creatorcontrib><creatorcontrib>Fahie-Wilson, Michael N.</creatorcontrib><creatorcontrib>McKenna, T. Joseph</creatorcontrib><title>Gross Variability in the Detection of Prolactin in Sera Containing Big Big Prolactin (Macroprolactin) by Commercial Immunoassays</title><title>The journal of clinical endocrinology and metabolism</title><addtitle>J Clin Endocrinol Metab</addtitle><description>A high molecular mass form of prolactin (PRL), macroprolactin, accumulates in the sera of some subjects. Although macroprolactin exhibits limited bioactivity in vivo, it retains immunoreactivity. We examined the frequency of macroprolactinemia in clinical practice and the ability of immunoassay systems to distinguish between macroprolactin and monomeric PRL. Of 300 hyperprolactinemic sera identified, 71 normalized following treatment of sera with polyethylene glycol, indicating that 24% of hyperprolactinemia could be accounted for by macroprolactin. Ten of these macroprolactinemic sera were circulated to 18 clinical laboratories. Two sets of PRL measurements of the 10 untreated sera were obtained from each of the nine most commonly used immunoassay systems. Across the nine assay systems, differences in the PRL estimates ranged from 2.3- to 7.8-fold. Elecsys users reported the highest PRL levels. Somewhat lower values were reported for DELFIA systems followed by Immuno-1, AxSYM, and Architect assays. The Immulite 2000 assay generated PRL levels equivalent to approximately 50% of those reported by the high-reading methods. The lowest PRL levels were reported by Access, ACS:180, and Centaur systems. To avoid confusion caused by the frequent presence of macroprolactin accounting for hyperprolactinemia, secondary screening for the presence of macroprolactin is recommended.</description><subject>Adult</subject><subject>Biological and medical sciences</subject><subject>Chromatography, Gel</subject><subject>Endocrinology</subject><subject>Female</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Hormones and neuropeptides. Regulation</subject><subject>Humans</subject><subject>Hyperprolactinemia - blood</subject><subject>Hypothalamus. Hypophysis. Epiphysis. Urophysis</subject><subject>Immunoassay - methods</subject><subject>Immunoassay - standards</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques</subject><subject>Polyethylene Glycols - pharmacology</subject><subject>Prolactin - blood</subject><subject>Solvents - pharmacology</subject><subject>Vertebrates: endocrinology</subject><issn>0021-972X</issn><issn>1945-7197</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kE1v1DAQhi1ERbctV47IF1A5ZLEdO06OZYG2UhFIfIhbNHHG4FViL3Zy2Ft_Ol5l0Z44jEajeWb06iHkBWdrLjh7uzVrwRgvGOeNLJ-QVW6q0LzRT8mKMcGLRouf5-QipW3mpFTlM3LOhayqUugVebyNISX6A6KDzg1u2lPn6fQb6Xuc0EwueBos_RLDAHnyh-1XjEA3wU_gvPO_6Du31Am6_gQmht2_-Q3t9vlgHDEaBwO9H8fZB0gJ9umKnFkYEj4_9kvy_eOHb5u74uHz7f3m5qEwUpdTUaLGHpmqhOprpZtS8AZBM1sJKdBWPWrWKwsdSGVYA7KsWA11Z5FBb-u6vCSvl7851Z8Z09SOLhkcBvAY5tRqoZXWqsngegHNwUxE2-6iGyHuW87ag_N2a9qD83Zxng9eHj_P3Yj9CT9KzsCrIwDJwGAjeOPSiZNScKVU5tTCoe-Dic7jLmJK7TbM0Wc3_wvwF89TnIc</recordid><startdate>20021201</startdate><enddate>20021201</enddate><creator>Smith, Thomas P.</creator><creator>Suliman, Abdulwahab M.</creator><creator>Fahie-Wilson, Michael N.</creator><creator>McKenna, T. Joseph</creator><general>Endocrine Society</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20021201</creationdate><title>Gross Variability in the Detection of Prolactin in Sera Containing Big Big Prolactin (Macroprolactin) by Commercial Immunoassays</title><author>Smith, Thomas P. ; Suliman, Abdulwahab M. ; Fahie-Wilson, Michael N. ; McKenna, T. Joseph</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c473t-3e7ede05625d85793219ea70f6242ef6de70d5faba45c09a43608a8bfe0adf883</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Adult</topic><topic>Biological and medical sciences</topic><topic>Chromatography, Gel</topic><topic>Endocrinology</topic><topic>Female</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Hormones and neuropeptides. Regulation</topic><topic>Humans</topic><topic>Hyperprolactinemia - blood</topic><topic>Hypothalamus. Hypophysis. Epiphysis. Urophysis</topic><topic>Immunoassay - methods</topic><topic>Immunoassay - standards</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques</topic><topic>Polyethylene Glycols - pharmacology</topic><topic>Prolactin - blood</topic><topic>Solvents - pharmacology</topic><topic>Vertebrates: endocrinology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Smith, Thomas P.</creatorcontrib><creatorcontrib>Suliman, Abdulwahab M.</creatorcontrib><creatorcontrib>Fahie-Wilson, Michael N.</creatorcontrib><creatorcontrib>McKenna, T. Joseph</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The journal of clinical endocrinology and metabolism</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Smith, Thomas P.</au><au>Suliman, Abdulwahab M.</au><au>Fahie-Wilson, Michael N.</au><au>McKenna, T. Joseph</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Gross Variability in the Detection of Prolactin in Sera Containing Big Big Prolactin (Macroprolactin) by Commercial Immunoassays</atitle><jtitle>The journal of clinical endocrinology and metabolism</jtitle><addtitle>J Clin Endocrinol Metab</addtitle><date>2002-12-01</date><risdate>2002</risdate><volume>87</volume><issue>12</issue><spage>5410</spage><epage>5415</epage><pages>5410-5415</pages><issn>0021-972X</issn><eissn>1945-7197</eissn><coden>JCEMAZ</coden><abstract>A high molecular mass form of prolactin (PRL), macroprolactin, accumulates in the sera of some subjects. Although macroprolactin exhibits limited bioactivity in vivo, it retains immunoreactivity. We examined the frequency of macroprolactinemia in clinical practice and the ability of immunoassay systems to distinguish between macroprolactin and monomeric PRL. Of 300 hyperprolactinemic sera identified, 71 normalized following treatment of sera with polyethylene glycol, indicating that 24% of hyperprolactinemia could be accounted for by macroprolactin. Ten of these macroprolactinemic sera were circulated to 18 clinical laboratories. Two sets of PRL measurements of the 10 untreated sera were obtained from each of the nine most commonly used immunoassay systems. Across the nine assay systems, differences in the PRL estimates ranged from 2.3- to 7.8-fold. Elecsys users reported the highest PRL levels. Somewhat lower values were reported for DELFIA systems followed by Immuno-1, AxSYM, and Architect assays. The Immulite 2000 assay generated PRL levels equivalent to approximately 50% of those reported by the high-reading methods. The lowest PRL levels were reported by Access, ACS:180, and Centaur systems. To avoid confusion caused by the frequent presence of macroprolactin accounting for hyperprolactinemia, secondary screening for the presence of macroprolactin is recommended.</abstract><cop>Bethesda, MD</cop><pub>Endocrine Society</pub><pmid>12466327</pmid><doi>10.1210/jc.2001-011943</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-972X |
ispartof | The journal of clinical endocrinology and metabolism, 2002-12, Vol.87 (12), p.5410-5415 |
issn | 0021-972X 1945-7197 |
language | eng |
recordid | cdi_proquest_miscellaneous_72757759 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Oxford University Press Journals All Titles (1996-Current) |
subjects | Adult Biological and medical sciences Chromatography, Gel Endocrinology Female Fundamental and applied biological sciences. Psychology Hormones and neuropeptides. Regulation Humans Hyperprolactinemia - blood Hypothalamus. Hypophysis. Epiphysis. Urophysis Immunoassay - methods Immunoassay - standards Investigative techniques, diagnostic techniques (general aspects) Male Medical sciences Middle Aged Pathology. Cytology. Biochemistry. Spectrometry. Miscellaneous investigative techniques Polyethylene Glycols - pharmacology Prolactin - blood Solvents - pharmacology Vertebrates: endocrinology |
title | Gross Variability in the Detection of Prolactin in Sera Containing Big Big Prolactin (Macroprolactin) by Commercial Immunoassays |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T19%3A07%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Gross%20Variability%20in%20the%20Detection%20of%20Prolactin%20in%20Sera%20Containing%20Big%20Big%20Prolactin%20(Macroprolactin)%20by%20Commercial%20Immunoassays&rft.jtitle=The%20journal%20of%20clinical%20endocrinology%20and%20metabolism&rft.au=Smith,%20Thomas%20P.&rft.date=2002-12-01&rft.volume=87&rft.issue=12&rft.spage=5410&rft.epage=5415&rft.pages=5410-5415&rft.issn=0021-972X&rft.eissn=1945-7197&rft.coden=JCEMAZ&rft_id=info:doi/10.1210/jc.2001-011943&rft_dat=%3Cproquest_cross%3E72757759%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72757759&rft_id=info:pmid/12466327&rfr_iscdi=true |