Evaluation of a dual hemoglobin A(2)/A(1c) quantitation kit on the bio-rad variant II automated hemoglobin analyzer

Quantitation of hemoglobin (Hb) A(1c) and investigation of hemoglobinopathy on the Bio-Rad Variant analyzers require a switch between 2 separate kits that is time consuming and causes errors. Evaluation of a new Variant II HbA(2)/HbA(1c) Dual kit capable of both Hb A(1c) quantitation and hemoglobino...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of pathology & laboratory medicine (1976) 2002-12, Vol.126 (12), p.1494-1500
Hauptverfasser: Lafferty, John D, McFarlane, Andrew G, K Chui, David H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1500
container_issue 12
container_start_page 1494
container_title Archives of pathology & laboratory medicine (1976)
container_volume 126
creator Lafferty, John D
McFarlane, Andrew G
K Chui, David H
description Quantitation of hemoglobin (Hb) A(1c) and investigation of hemoglobinopathy on the Bio-Rad Variant analyzers require a switch between 2 separate kits that is time consuming and causes errors. Evaluation of a new Variant II HbA(2)/HbA(1c) Dual kit capable of both Hb A(1c) quantitation and hemoglobinopathy investigation on a single kit. We evaluated Hb A(1c), Hb A(2), and Hb F quantitation for precision, linearity, and correlation with current methodology. We also evaluated detection of Hb variants and correlation of Hb Barts quantitation. Hamilton Regional Laboratory Medicine Program, Provincial Hemoglobinopathy Laboratory, St Joseph's Healthcare Site, Hamilton, Ontario. Patient blood samples submitted for Hb A(1c) quantitation or hemoglobinopathy investigation. Precision, linearity, linear regression, and reference interval validation. We provide tables and figures illustrating precision, linearity, linear regression, and quantitation of Hb variants. We validated reference intervals for Hb A(1c), Hb A(2), and Hb F. The dual kit provides precise Hb A(1c), Hb A(2), and Hb F quantitation. The results show good linearity and correlate well with the results of current methods. We detected all clinically important Hb variants and a wide variety of rare variants. The dual kit has several advantages: it eliminates the need for extensive kit switch over; improves utility for newborn screening because of its quantification of Hb Barts; permits quantification of Hb A(1c) using the beta-Thal method; and eliminates the need for separate Hb A(2) reference intervals for patients with Hb S because of its accurate quantitation of Hb A(2) in the presence of Hb S.
format Article
fullrecord <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_72732388</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A557706076</galeid><sourcerecordid>A557706076</sourcerecordid><originalsourceid>FETCH-LOGICAL-g247t-e577f4662d9584af53344afa4fe9d19f3f9b332e2963d4507b8257fe3588c7e43</originalsourceid><addsrcrecordid>eNptkUFLw0AQhXNQbK3-BdlTaQ_RZDebTY6lVC0UvOg5TJLZdnWTbbObQv31rrRChTKHxwzfGx4zV8EwiiIW5nnGB8GttZ--zSmNb4JBTBOe0jgaBnaxB92DU6YlRhIgdQ-abLAxa21K1ZLZhE6fZpO4mpJdD61T7gh_KUe8uA2SUpmwg5rsoVOeIMslgd6ZBhzW56ugBX34xu4uuJagLd6fdBR8PC_e56_h6u1lOZ-twjVNhAuRCyGTNKV1zrMEJGcs8QKJxLyOc8lkXjJGkeYpqxMeiTKjXEhkPMsqgQkbBePj3m1ndj1aVzTKVqg1tGh6WwgqGGVZ5sHwCK5BY6FaaVwH1Rpb7ECbFqXy4xn3eaI0EqnnHy_wvmpsVHXRMD4zbBC021ij-99L2v_gwylyXzZYF9tONdAdir-HsR8-lI5u</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72732388</pqid></control><display><type>article</type><title>Evaluation of a dual hemoglobin A(2)/A(1c) quantitation kit on the bio-rad variant II automated hemoglobin analyzer</title><source>MEDLINE</source><source>Allen Press Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Lafferty, John D ; McFarlane, Andrew G ; K Chui, David H</creator><creatorcontrib>Lafferty, John D ; McFarlane, Andrew G ; K Chui, David H</creatorcontrib><description>Quantitation of hemoglobin (Hb) A(1c) and investigation of hemoglobinopathy on the Bio-Rad Variant analyzers require a switch between 2 separate kits that is time consuming and causes errors. Evaluation of a new Variant II HbA(2)/HbA(1c) Dual kit capable of both Hb A(1c) quantitation and hemoglobinopathy investigation on a single kit. We evaluated Hb A(1c), Hb A(2), and Hb F quantitation for precision, linearity, and correlation with current methodology. We also evaluated detection of Hb variants and correlation of Hb Barts quantitation. Hamilton Regional Laboratory Medicine Program, Provincial Hemoglobinopathy Laboratory, St Joseph's Healthcare Site, Hamilton, Ontario. Patient blood samples submitted for Hb A(1c) quantitation or hemoglobinopathy investigation. Precision, linearity, linear regression, and reference interval validation. We provide tables and figures illustrating precision, linearity, linear regression, and quantitation of Hb variants. We validated reference intervals for Hb A(1c), Hb A(2), and Hb F. The dual kit provides precise Hb A(1c), Hb A(2), and Hb F quantitation. The results show good linearity and correlate well with the results of current methods. We detected all clinically important Hb variants and a wide variety of rare variants. The dual kit has several advantages: it eliminates the need for extensive kit switch over; improves utility for newborn screening because of its quantification of Hb Barts; permits quantification of Hb A(1c) using the beta-Thal method; and eliminates the need for separate Hb A(2) reference intervals for patients with Hb S because of its accurate quantitation of Hb A(2) in the presence of Hb S.</description><identifier>ISSN: 0003-9985</identifier><identifier>ISSN: 1543-2165</identifier><identifier>PMID: 12456210</identifier><language>eng</language><publisher>United States: College of American Pathologists</publisher><subject>Diagnosis ; Fetal Hemoglobin - analysis ; Glycated Hemoglobin A - analysis ; Hemoglobin A2 - analysis ; Hemoglobinopathies ; Hemoglobins ; Humans ; Reagent Kits, Diagnostic ; Variation (Biology)</subject><ispartof>Archives of pathology &amp; laboratory medicine (1976), 2002-12, Vol.126 (12), p.1494-1500</ispartof><rights>COPYRIGHT 2002 College of American Pathologists</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12456210$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lafferty, John D</creatorcontrib><creatorcontrib>McFarlane, Andrew G</creatorcontrib><creatorcontrib>K Chui, David H</creatorcontrib><title>Evaluation of a dual hemoglobin A(2)/A(1c) quantitation kit on the bio-rad variant II automated hemoglobin analyzer</title><title>Archives of pathology &amp; laboratory medicine (1976)</title><addtitle>Arch Pathol Lab Med</addtitle><description>Quantitation of hemoglobin (Hb) A(1c) and investigation of hemoglobinopathy on the Bio-Rad Variant analyzers require a switch between 2 separate kits that is time consuming and causes errors. Evaluation of a new Variant II HbA(2)/HbA(1c) Dual kit capable of both Hb A(1c) quantitation and hemoglobinopathy investigation on a single kit. We evaluated Hb A(1c), Hb A(2), and Hb F quantitation for precision, linearity, and correlation with current methodology. We also evaluated detection of Hb variants and correlation of Hb Barts quantitation. Hamilton Regional Laboratory Medicine Program, Provincial Hemoglobinopathy Laboratory, St Joseph's Healthcare Site, Hamilton, Ontario. Patient blood samples submitted for Hb A(1c) quantitation or hemoglobinopathy investigation. Precision, linearity, linear regression, and reference interval validation. We provide tables and figures illustrating precision, linearity, linear regression, and quantitation of Hb variants. We validated reference intervals for Hb A(1c), Hb A(2), and Hb F. The dual kit provides precise Hb A(1c), Hb A(2), and Hb F quantitation. The results show good linearity and correlate well with the results of current methods. We detected all clinically important Hb variants and a wide variety of rare variants. The dual kit has several advantages: it eliminates the need for extensive kit switch over; improves utility for newborn screening because of its quantification of Hb Barts; permits quantification of Hb A(1c) using the beta-Thal method; and eliminates the need for separate Hb A(2) reference intervals for patients with Hb S because of its accurate quantitation of Hb A(2) in the presence of Hb S.</description><subject>Diagnosis</subject><subject>Fetal Hemoglobin - analysis</subject><subject>Glycated Hemoglobin A - analysis</subject><subject>Hemoglobin A2 - analysis</subject><subject>Hemoglobinopathies</subject><subject>Hemoglobins</subject><subject>Humans</subject><subject>Reagent Kits, Diagnostic</subject><subject>Variation (Biology)</subject><issn>0003-9985</issn><issn>1543-2165</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNptkUFLw0AQhXNQbK3-BdlTaQ_RZDebTY6lVC0UvOg5TJLZdnWTbbObQv31rrRChTKHxwzfGx4zV8EwiiIW5nnGB8GttZ--zSmNb4JBTBOe0jgaBnaxB92DU6YlRhIgdQ-abLAxa21K1ZLZhE6fZpO4mpJdD61T7gh_KUe8uA2SUpmwg5rsoVOeIMslgd6ZBhzW56ugBX34xu4uuJagLd6fdBR8PC_e56_h6u1lOZ-twjVNhAuRCyGTNKV1zrMEJGcs8QKJxLyOc8lkXjJGkeYpqxMeiTKjXEhkPMsqgQkbBePj3m1ndj1aVzTKVqg1tGh6WwgqGGVZ5sHwCK5BY6FaaVwH1Rpb7ECbFqXy4xn3eaI0EqnnHy_wvmpsVHXRMD4zbBC021ij-99L2v_gwylyXzZYF9tONdAdir-HsR8-lI5u</recordid><startdate>200212</startdate><enddate>200212</enddate><creator>Lafferty, John D</creator><creator>McFarlane, Andrew G</creator><creator>K Chui, David H</creator><general>College of American Pathologists</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>200212</creationdate><title>Evaluation of a dual hemoglobin A(2)/A(1c) quantitation kit on the bio-rad variant II automated hemoglobin analyzer</title><author>Lafferty, John D ; McFarlane, Andrew G ; K Chui, David H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-g247t-e577f4662d9584af53344afa4fe9d19f3f9b332e2963d4507b8257fe3588c7e43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Diagnosis</topic><topic>Fetal Hemoglobin - analysis</topic><topic>Glycated Hemoglobin A - analysis</topic><topic>Hemoglobin A2 - analysis</topic><topic>Hemoglobinopathies</topic><topic>Hemoglobins</topic><topic>Humans</topic><topic>Reagent Kits, Diagnostic</topic><topic>Variation (Biology)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lafferty, John D</creatorcontrib><creatorcontrib>McFarlane, Andrew G</creatorcontrib><creatorcontrib>K Chui, David H</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Archives of pathology &amp; laboratory medicine (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lafferty, John D</au><au>McFarlane, Andrew G</au><au>K Chui, David H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of a dual hemoglobin A(2)/A(1c) quantitation kit on the bio-rad variant II automated hemoglobin analyzer</atitle><jtitle>Archives of pathology &amp; laboratory medicine (1976)</jtitle><addtitle>Arch Pathol Lab Med</addtitle><date>2002-12</date><risdate>2002</risdate><volume>126</volume><issue>12</issue><spage>1494</spage><epage>1500</epage><pages>1494-1500</pages><issn>0003-9985</issn><issn>1543-2165</issn><abstract>Quantitation of hemoglobin (Hb) A(1c) and investigation of hemoglobinopathy on the Bio-Rad Variant analyzers require a switch between 2 separate kits that is time consuming and causes errors. Evaluation of a new Variant II HbA(2)/HbA(1c) Dual kit capable of both Hb A(1c) quantitation and hemoglobinopathy investigation on a single kit. We evaluated Hb A(1c), Hb A(2), and Hb F quantitation for precision, linearity, and correlation with current methodology. We also evaluated detection of Hb variants and correlation of Hb Barts quantitation. Hamilton Regional Laboratory Medicine Program, Provincial Hemoglobinopathy Laboratory, St Joseph's Healthcare Site, Hamilton, Ontario. Patient blood samples submitted for Hb A(1c) quantitation or hemoglobinopathy investigation. Precision, linearity, linear regression, and reference interval validation. We provide tables and figures illustrating precision, linearity, linear regression, and quantitation of Hb variants. We validated reference intervals for Hb A(1c), Hb A(2), and Hb F. The dual kit provides precise Hb A(1c), Hb A(2), and Hb F quantitation. The results show good linearity and correlate well with the results of current methods. We detected all clinically important Hb variants and a wide variety of rare variants. The dual kit has several advantages: it eliminates the need for extensive kit switch over; improves utility for newborn screening because of its quantification of Hb Barts; permits quantification of Hb A(1c) using the beta-Thal method; and eliminates the need for separate Hb A(2) reference intervals for patients with Hb S because of its accurate quantitation of Hb A(2) in the presence of Hb S.</abstract><cop>United States</cop><pub>College of American Pathologists</pub><pmid>12456210</pmid><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-9985
ispartof Archives of pathology & laboratory medicine (1976), 2002-12, Vol.126 (12), p.1494-1500
issn 0003-9985
1543-2165
language eng
recordid cdi_proquest_miscellaneous_72732388
source MEDLINE; Allen Press Journals; EZB-FREE-00999 freely available EZB journals
subjects Diagnosis
Fetal Hemoglobin - analysis
Glycated Hemoglobin A - analysis
Hemoglobin A2 - analysis
Hemoglobinopathies
Hemoglobins
Humans
Reagent Kits, Diagnostic
Variation (Biology)
title Evaluation of a dual hemoglobin A(2)/A(1c) quantitation kit on the bio-rad variant II automated hemoglobin analyzer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T00%3A33%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20a%20dual%20hemoglobin%20A(2)/A(1c)%20quantitation%20kit%20on%20the%20bio-rad%20variant%20II%20automated%20hemoglobin%20analyzer&rft.jtitle=Archives%20of%20pathology%20&%20laboratory%20medicine%20(1976)&rft.au=Lafferty,%20John%20D&rft.date=2002-12&rft.volume=126&rft.issue=12&rft.spage=1494&rft.epage=1500&rft.pages=1494-1500&rft.issn=0003-9985&rft_id=info:doi/&rft_dat=%3Cgale_proqu%3EA557706076%3C/gale_proqu%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72732388&rft_id=info:pmid/12456210&rft_galeid=A557706076&rfr_iscdi=true