Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study
Aim The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system Methodology Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived fr...
Gespeichert in:
Veröffentlicht in: | International endodontic journal 2000-05, Vol.33 (3), p.272-278 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 278 |
---|---|
container_issue | 3 |
container_start_page | 272 |
container_title | International endodontic journal |
container_volume | 33 |
creator | Saunders, M. B. Gulabivala, K. Holt, R. Kahan, R. S. |
description | Aim The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system
Methodology Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8–9 roots on periapical radiographs of single‐ and multirooted teeth, with and without previous root canal therapy and 3–4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra‐observer agreement was tested by asking the students to re‐examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter‐observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8–9 different roots from the pool of radiographs. A further assessment of inter‐observer variation was made by comparing these observations with the Gold Standard.
Results Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra‐ and inter‐observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra‐observer recordings showed ‘good’ or ‘very good’ Kappa agreement, but only three out of 25 inter‐observer observations achieved ‘good’ or ‘very good’ values. Inter‐observer variation was improved following the revision session with 16 out of 25 observations achieving ‘good’ or ‘very good’ Kappa agreement.
Conclusions Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to improve the accuracy and reproducibility of the observations entered. |
doi_str_mv | 10.1046/j.1365-2591.1999.00304.x |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72598859</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72598859</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3174-2060ba0a611f8da7a8cab5a2252ef31b16f19ceafcc3784297729e78c5b5e4e43</originalsourceid><addsrcrecordid>eNqNkc9u1DAQxi0EokvhFZBP3BLs2IkTxAWVdlsof4RAHK2JMyleknixk3b3CfraOJtVuXLyyP5-34y_IYRylnImi9eblIsiT7K84imvqiplTDCZ7h6R1cPDY7JiXIokK8v8hDwLYcMYy5ngT8kJ54IpKdWK3H_DzkJtOzvuqWuph8a6Gw_bX9ZQVwf0tzBaNwTq0TjfYEPdQIFuvWud74H2CGHy8XoKdrihdhjRJxSGZi49JIsHenoL3h6s3hzw2La3A_g9DePU7J-TJy10AV8cz1Py4-L8-9llcv1lfXX27joxgiuZZKxgNTAoOG_LBhSUBuocsizPsBW85kXLK4PQGiNUKbNKqaxCVZq8zlGiFKfk1eIbP_BnwjDq3gaDXQcDuiloFaOLgVVRWC5C410IHlu99baP82rO9LwEvdFz1nrOWs9L0Icl6F1EXx57THWPzT_wmHoUvF0Ed7bD_X8b66vzD7GIeLLgNoy4e8DB_9aFEirXPz-v9cXX9x_X6tOlXou_6tOoHA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72598859</pqid></control><display><type>article</type><title>Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study</title><source>MEDLINE</source><source>Wiley Online Library All Journals</source><creator>Saunders, M. B. ; Gulabivala, K. ; Holt, R. ; Kahan, R. S.</creator><creatorcontrib>Saunders, M. B. ; Gulabivala, K. ; Holt, R. ; Kahan, R. S.</creatorcontrib><description>Aim The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system
Methodology Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8–9 roots on periapical radiographs of single‐ and multirooted teeth, with and without previous root canal therapy and 3–4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra‐observer agreement was tested by asking the students to re‐examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter‐observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8–9 different roots from the pool of radiographs. A further assessment of inter‐observer variation was made by comparing these observations with the Gold Standard.
Results Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra‐ and inter‐observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra‐observer recordings showed ‘good’ or ‘very good’ Kappa agreement, but only three out of 25 inter‐observer observations achieved ‘good’ or ‘very good’ values. Inter‐observer variation was improved following the revision session with 16 out of 25 observations achieving ‘good’ or ‘very good’ Kappa agreement.
Conclusions Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to improve the accuracy and reproducibility of the observations entered.</description><identifier>ISSN: 0143-2885</identifier><identifier>EISSN: 1365-2591</identifier><identifier>DOI: 10.1046/j.1365-2591.1999.00304.x</identifier><identifier>PMID: 11307447</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Science Ltd</publisher><subject>Data Collection - methods ; Dental Pulp Cavity - diagnostic imaging ; Dentistry ; Endodontics - education ; Humans ; Observer Variation ; Periapical Diseases - diagnostic imaging ; Pilot Projects ; proforma ; radiographic evaluation ; Radiography, Dental - standards ; Radiology - education ; Reference Standards ; Reproducibility of Results ; Root Canal Therapy - standards</subject><ispartof>International endodontic journal, 2000-05, Vol.33 (3), p.272-278</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3174-2060ba0a611f8da7a8cab5a2252ef31b16f19ceafcc3784297729e78c5b5e4e43</citedby><cites>FETCH-LOGICAL-c3174-2060ba0a611f8da7a8cab5a2252ef31b16f19ceafcc3784297729e78c5b5e4e43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1046%2Fj.1365-2591.1999.00304.x$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1046%2Fj.1365-2591.1999.00304.x$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,777,781,1412,27905,27906,45555,45556</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11307447$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Saunders, M. B.</creatorcontrib><creatorcontrib>Gulabivala, K.</creatorcontrib><creatorcontrib>Holt, R.</creatorcontrib><creatorcontrib>Kahan, R. S.</creatorcontrib><title>Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study</title><title>International endodontic journal</title><addtitle>Int Endod J</addtitle><description>Aim The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system
Methodology Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8–9 roots on periapical radiographs of single‐ and multirooted teeth, with and without previous root canal therapy and 3–4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra‐observer agreement was tested by asking the students to re‐examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter‐observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8–9 different roots from the pool of radiographs. A further assessment of inter‐observer variation was made by comparing these observations with the Gold Standard.
Results Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra‐ and inter‐observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra‐observer recordings showed ‘good’ or ‘very good’ Kappa agreement, but only three out of 25 inter‐observer observations achieved ‘good’ or ‘very good’ values. Inter‐observer variation was improved following the revision session with 16 out of 25 observations achieving ‘good’ or ‘very good’ Kappa agreement.
Conclusions Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to improve the accuracy and reproducibility of the observations entered.</description><subject>Data Collection - methods</subject><subject>Dental Pulp Cavity - diagnostic imaging</subject><subject>Dentistry</subject><subject>Endodontics - education</subject><subject>Humans</subject><subject>Observer Variation</subject><subject>Periapical Diseases - diagnostic imaging</subject><subject>Pilot Projects</subject><subject>proforma</subject><subject>radiographic evaluation</subject><subject>Radiography, Dental - standards</subject><subject>Radiology - education</subject><subject>Reference Standards</subject><subject>Reproducibility of Results</subject><subject>Root Canal Therapy - standards</subject><issn>0143-2885</issn><issn>1365-2591</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNkc9u1DAQxi0EokvhFZBP3BLs2IkTxAWVdlsof4RAHK2JMyleknixk3b3CfraOJtVuXLyyP5-34y_IYRylnImi9eblIsiT7K84imvqiplTDCZ7h6R1cPDY7JiXIokK8v8hDwLYcMYy5ngT8kJ54IpKdWK3H_DzkJtOzvuqWuph8a6Gw_bX9ZQVwf0tzBaNwTq0TjfYEPdQIFuvWud74H2CGHy8XoKdrihdhjRJxSGZi49JIsHenoL3h6s3hzw2La3A_g9DePU7J-TJy10AV8cz1Py4-L8-9llcv1lfXX27joxgiuZZKxgNTAoOG_LBhSUBuocsizPsBW85kXLK4PQGiNUKbNKqaxCVZq8zlGiFKfk1eIbP_BnwjDq3gaDXQcDuiloFaOLgVVRWC5C410IHlu99baP82rO9LwEvdFz1nrOWs9L0Icl6F1EXx57THWPzT_wmHoUvF0Ed7bD_X8b66vzD7GIeLLgNoy4e8DB_9aFEirXPz-v9cXX9x_X6tOlXou_6tOoHA</recordid><startdate>200005</startdate><enddate>200005</enddate><creator>Saunders, M. B.</creator><creator>Gulabivala, K.</creator><creator>Holt, R.</creator><creator>Kahan, R. S.</creator><general>Blackwell Science Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200005</creationdate><title>Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study</title><author>Saunders, M. B. ; Gulabivala, K. ; Holt, R. ; Kahan, R. S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3174-2060ba0a611f8da7a8cab5a2252ef31b16f19ceafcc3784297729e78c5b5e4e43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Data Collection - methods</topic><topic>Dental Pulp Cavity - diagnostic imaging</topic><topic>Dentistry</topic><topic>Endodontics - education</topic><topic>Humans</topic><topic>Observer Variation</topic><topic>Periapical Diseases - diagnostic imaging</topic><topic>Pilot Projects</topic><topic>proforma</topic><topic>radiographic evaluation</topic><topic>Radiography, Dental - standards</topic><topic>Radiology - education</topic><topic>Reference Standards</topic><topic>Reproducibility of Results</topic><topic>Root Canal Therapy - standards</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Saunders, M. B.</creatorcontrib><creatorcontrib>Gulabivala, K.</creatorcontrib><creatorcontrib>Holt, R.</creatorcontrib><creatorcontrib>Kahan, R. S.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International endodontic journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saunders, M. B.</au><au>Gulabivala, K.</au><au>Holt, R.</au><au>Kahan, R. S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study</atitle><jtitle>International endodontic journal</jtitle><addtitle>Int Endod J</addtitle><date>2000-05</date><risdate>2000</risdate><volume>33</volume><issue>3</issue><spage>272</spage><epage>278</epage><pages>272-278</pages><issn>0143-2885</issn><eissn>1365-2591</eissn><abstract>Aim The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system
Methodology Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8–9 roots on periapical radiographs of single‐ and multirooted teeth, with and without previous root canal therapy and 3–4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra‐observer agreement was tested by asking the students to re‐examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter‐observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8–9 different roots from the pool of radiographs. A further assessment of inter‐observer variation was made by comparing these observations with the Gold Standard.
Results Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra‐ and inter‐observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra‐observer recordings showed ‘good’ or ‘very good’ Kappa agreement, but only three out of 25 inter‐observer observations achieved ‘good’ or ‘very good’ values. Inter‐observer variation was improved following the revision session with 16 out of 25 observations achieving ‘good’ or ‘very good’ Kappa agreement.
Conclusions Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to improve the accuracy and reproducibility of the observations entered.</abstract><cop>Oxford, UK</cop><pub>Blackwell Science Ltd</pub><pmid>11307447</pmid><doi>10.1046/j.1365-2591.1999.00304.x</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0143-2885 |
ispartof | International endodontic journal, 2000-05, Vol.33 (3), p.272-278 |
issn | 0143-2885 1365-2591 |
language | eng |
recordid | cdi_proquest_miscellaneous_72598859 |
source | MEDLINE; Wiley Online Library All Journals |
subjects | Data Collection - methods Dental Pulp Cavity - diagnostic imaging Dentistry Endodontics - education Humans Observer Variation Periapical Diseases - diagnostic imaging Pilot Projects proforma radiographic evaluation Radiography, Dental - standards Radiology - education Reference Standards Reproducibility of Results Root Canal Therapy - standards |
title | Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T15%3A52%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliability%20of%20radiographic%20observations%20recorded%20on%20a%20proforma%20measured%20using%20inter-%20and%20intra-observer%20variation:%20a%20preliminary%20study&rft.jtitle=International%20endodontic%20journal&rft.au=Saunders,%20M.%20B.&rft.date=2000-05&rft.volume=33&rft.issue=3&rft.spage=272&rft.epage=278&rft.pages=272-278&rft.issn=0143-2885&rft.eissn=1365-2591&rft_id=info:doi/10.1046/j.1365-2591.1999.00304.x&rft_dat=%3Cproquest_cross%3E72598859%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72598859&rft_id=info:pmid/11307447&rfr_iscdi=true |