Computerised method for acquisition and display of gastrointestinal motility data
A computerised system is developed for the acquisition and display of gastrointestinal motility data which utilises a purpose developed software program called 'PC-motil', running on an IBM compatible microcomputer. 'PC-motil' displays data during collection, writes data to disk...
Gespeichert in:
Veröffentlicht in: | Medical & biological engineering & computing 1991-05, Vol.29 (3), p.304-308 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 308 |
---|---|
container_issue | 3 |
container_start_page | 304 |
container_title | Medical & biological engineering & computing |
container_volume | 29 |
creator | WALDRON, B STOREY, B. E SMITH, D CULLEN, P. T CAMPBELL, F. C |
description | A computerised system is developed for the acquisition and display of gastrointestinal motility data which utilises a purpose developed software program called 'PC-motil', running on an IBM compatible microcomputer. 'PC-motil' displays data during collection, writes data to disk file and compresses all data at the end of a study on to a single monitor screen for convenient overview. Any area of interest, in single or multiple channels, may be selected and expanded for detailed examination. This system is tested by the recording of gastric and jejunal motility patterns of 11 healthy volunteers in fasting and fed states. All antral and jejunal migrating motor complexes (MMCs) in fasting studies, as well as all fed motility patterns were recognisable in both 'compressed' and 'expanded' form. The reproduction of motility patterns by the computer based system was indistinguishable from that of a conventional analogue chart recorder. This computerised system provides a convenient and cost-effective means of acquisition, storage and display of motility data in digital form. |
doi_str_mv | 10.1007/BF02446713 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72459161</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72459161</sourcerecordid><originalsourceid>FETCH-LOGICAL-c362t-44cbcb2efdc01a4523f36b00705af873f154f4e332c92ffd9e9c0d606eebd1253</originalsourceid><addsrcrecordid>eNpFkM9LwzAYhoMoc04v3oUcxINQzZd8bdejDqfCQAQ9lzQ_NNI2W5Ie9t9b2XCn7_A-vLzfQ8glsDtgrLx_XDKOWJQgjsgUSoSMIeIxmTJAljGA-Sk5i_GHMQ45xwmZQIWCF2JK3he-Ww_JBBeNpp1J315T6wOVajO46JLzPZW9ptrFdSu31Fv6JWMK3vXJxOR62dLOJ9e6tKVaJnlOTqxso7nY3xn5XD59LF6y1dvz6-JhlSlR8JQhqkY13FitGEjMubCiaMZvWC7tvBQWcrRohOCq4tbqylSK6YIVxjQaeC5m5GbXuw5-M4xT6s5FZdpW9sYPsS455hUUMIK3O1AFH2Mwtl4H18mwrYHVf_7qg78Rvtq3Dk1n9AHdCRvz630uo5KtDbJXLv5jOQIIPhe_kTh4GQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72459161</pqid></control><display><type>article</type><title>Computerised method for acquisition and display of gastrointestinal motility data</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>WALDRON, B ; STOREY, B. E ; SMITH, D ; CULLEN, P. T ; CAMPBELL, F. C</creator><creatorcontrib>WALDRON, B ; STOREY, B. E ; SMITH, D ; CULLEN, P. T ; CAMPBELL, F. C</creatorcontrib><description>A computerised system is developed for the acquisition and display of gastrointestinal motility data which utilises a purpose developed software program called 'PC-motil', running on an IBM compatible microcomputer. 'PC-motil' displays data during collection, writes data to disk file and compresses all data at the end of a study on to a single monitor screen for convenient overview. Any area of interest, in single or multiple channels, may be selected and expanded for detailed examination. This system is tested by the recording of gastric and jejunal motility patterns of 11 healthy volunteers in fasting and fed states. All antral and jejunal migrating motor complexes (MMCs) in fasting studies, as well as all fed motility patterns were recognisable in both 'compressed' and 'expanded' form. The reproduction of motility patterns by the computer based system was indistinguishable from that of a conventional analogue chart recorder. This computerised system provides a convenient and cost-effective means of acquisition, storage and display of motility data in digital form.</description><identifier>ISSN: 0140-0118</identifier><identifier>EISSN: 1741-0444</identifier><identifier>DOI: 10.1007/BF02446713</identifier><identifier>PMID: 1943263</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Adult ; Biological and medical sciences ; Computerized, statistical medical data processing and models in biomedicine ; Female ; Gastrointestinal Motility - physiology ; Humans ; Male ; Medical sciences ; Microcomputers ; Signal Processing, Computer-Assisted ; Software Design</subject><ispartof>Medical & biological engineering & computing, 1991-05, Vol.29 (3), p.304-308</ispartof><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c362t-44cbcb2efdc01a4523f36b00705af873f154f4e332c92ffd9e9c0d606eebd1253</citedby><cites>FETCH-LOGICAL-c362t-44cbcb2efdc01a4523f36b00705af873f154f4e332c92ffd9e9c0d606eebd1253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=5411328$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1943263$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>WALDRON, B</creatorcontrib><creatorcontrib>STOREY, B. E</creatorcontrib><creatorcontrib>SMITH, D</creatorcontrib><creatorcontrib>CULLEN, P. T</creatorcontrib><creatorcontrib>CAMPBELL, F. C</creatorcontrib><title>Computerised method for acquisition and display of gastrointestinal motility data</title><title>Medical & biological engineering & computing</title><addtitle>Med Biol Eng Comput</addtitle><description>A computerised system is developed for the acquisition and display of gastrointestinal motility data which utilises a purpose developed software program called 'PC-motil', running on an IBM compatible microcomputer. 'PC-motil' displays data during collection, writes data to disk file and compresses all data at the end of a study on to a single monitor screen for convenient overview. Any area of interest, in single or multiple channels, may be selected and expanded for detailed examination. This system is tested by the recording of gastric and jejunal motility patterns of 11 healthy volunteers in fasting and fed states. All antral and jejunal migrating motor complexes (MMCs) in fasting studies, as well as all fed motility patterns were recognisable in both 'compressed' and 'expanded' form. The reproduction of motility patterns by the computer based system was indistinguishable from that of a conventional analogue chart recorder. This computerised system provides a convenient and cost-effective means of acquisition, storage and display of motility data in digital form.</description><subject>Adult</subject><subject>Biological and medical sciences</subject><subject>Computerized, statistical medical data processing and models in biomedicine</subject><subject>Female</subject><subject>Gastrointestinal Motility - physiology</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Microcomputers</subject><subject>Signal Processing, Computer-Assisted</subject><subject>Software Design</subject><issn>0140-0118</issn><issn>1741-0444</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1991</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkM9LwzAYhoMoc04v3oUcxINQzZd8bdejDqfCQAQ9lzQ_NNI2W5Ie9t9b2XCn7_A-vLzfQ8glsDtgrLx_XDKOWJQgjsgUSoSMIeIxmTJAljGA-Sk5i_GHMQ45xwmZQIWCF2JK3he-Ww_JBBeNpp1J315T6wOVajO46JLzPZW9ptrFdSu31Fv6JWMK3vXJxOR62dLOJ9e6tKVaJnlOTqxso7nY3xn5XD59LF6y1dvz6-JhlSlR8JQhqkY13FitGEjMubCiaMZvWC7tvBQWcrRohOCq4tbqylSK6YIVxjQaeC5m5GbXuw5-M4xT6s5FZdpW9sYPsS455hUUMIK3O1AFH2Mwtl4H18mwrYHVf_7qg78Rvtq3Dk1n9AHdCRvz630uo5KtDbJXLv5jOQIIPhe_kTh4GQ</recordid><startdate>19910501</startdate><enddate>19910501</enddate><creator>WALDRON, B</creator><creator>STOREY, B. E</creator><creator>SMITH, D</creator><creator>CULLEN, P. T</creator><creator>CAMPBELL, F. C</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19910501</creationdate><title>Computerised method for acquisition and display of gastrointestinal motility data</title><author>WALDRON, B ; STOREY, B. E ; SMITH, D ; CULLEN, P. T ; CAMPBELL, F. C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c362t-44cbcb2efdc01a4523f36b00705af873f154f4e332c92ffd9e9c0d606eebd1253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1991</creationdate><topic>Adult</topic><topic>Biological and medical sciences</topic><topic>Computerized, statistical medical data processing and models in biomedicine</topic><topic>Female</topic><topic>Gastrointestinal Motility - physiology</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Microcomputers</topic><topic>Signal Processing, Computer-Assisted</topic><topic>Software Design</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>WALDRON, B</creatorcontrib><creatorcontrib>STOREY, B. E</creatorcontrib><creatorcontrib>SMITH, D</creatorcontrib><creatorcontrib>CULLEN, P. T</creatorcontrib><creatorcontrib>CAMPBELL, F. C</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical & biological engineering & computing</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>WALDRON, B</au><au>STOREY, B. E</au><au>SMITH, D</au><au>CULLEN, P. T</au><au>CAMPBELL, F. C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computerised method for acquisition and display of gastrointestinal motility data</atitle><jtitle>Medical & biological engineering & computing</jtitle><addtitle>Med Biol Eng Comput</addtitle><date>1991-05-01</date><risdate>1991</risdate><volume>29</volume><issue>3</issue><spage>304</spage><epage>308</epage><pages>304-308</pages><issn>0140-0118</issn><eissn>1741-0444</eissn><abstract>A computerised system is developed for the acquisition and display of gastrointestinal motility data which utilises a purpose developed software program called 'PC-motil', running on an IBM compatible microcomputer. 'PC-motil' displays data during collection, writes data to disk file and compresses all data at the end of a study on to a single monitor screen for convenient overview. Any area of interest, in single or multiple channels, may be selected and expanded for detailed examination. This system is tested by the recording of gastric and jejunal motility patterns of 11 healthy volunteers in fasting and fed states. All antral and jejunal migrating motor complexes (MMCs) in fasting studies, as well as all fed motility patterns were recognisable in both 'compressed' and 'expanded' form. The reproduction of motility patterns by the computer based system was indistinguishable from that of a conventional analogue chart recorder. This computerised system provides a convenient and cost-effective means of acquisition, storage and display of motility data in digital form.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>1943263</pmid><doi>10.1007/BF02446713</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0140-0118 |
ispartof | Medical & biological engineering & computing, 1991-05, Vol.29 (3), p.304-308 |
issn | 0140-0118 1741-0444 |
language | eng |
recordid | cdi_proquest_miscellaneous_72459161 |
source | MEDLINE; SpringerLink Journals - AutoHoldings |
subjects | Adult Biological and medical sciences Computerized, statistical medical data processing and models in biomedicine Female Gastrointestinal Motility - physiology Humans Male Medical sciences Microcomputers Signal Processing, Computer-Assisted Software Design |
title | Computerised method for acquisition and display of gastrointestinal motility data |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T03%3A09%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computerised%20method%20for%20acquisition%20and%20display%20of%20gastrointestinal%20motility%20data&rft.jtitle=Medical%20&%20biological%20engineering%20&%20computing&rft.au=WALDRON,%20B&rft.date=1991-05-01&rft.volume=29&rft.issue=3&rft.spage=304&rft.epage=308&rft.pages=304-308&rft.issn=0140-0118&rft.eissn=1741-0444&rft_id=info:doi/10.1007/BF02446713&rft_dat=%3Cproquest_cross%3E72459161%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72459161&rft_id=info:pmid/1943263&rfr_iscdi=true |