Early ECG abnormalities associated with transcatheter closure of atrial septal defects using the Amplatzer® septal occluder
Conduction abnormalities and arrhythmias may occur in patients following secundum atrial septal defect (ASD) closure using the Amplatzer septal occluder (ASO). Therefore, the aim of this study was to prospectively perform ambulatory ECG monitoring to assess the electrocardiographic effects of transc...
Gespeichert in:
Veröffentlicht in: | Journal of interventional cardiac electrophysiology 2000-10, Vol.4 (3), p.469-474 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 474 |
---|---|
container_issue | 3 |
container_start_page | 469 |
container_title | Journal of interventional cardiac electrophysiology |
container_volume | 4 |
creator | HILL, Sharon L BERUL, Charles I PATEL, Hitendra T RHODES, Jonathan SUPRAN, Stacey E CAO, Qi-Ling HIJAZI, Ziyad M |
description | Conduction abnormalities and arrhythmias may occur in patients following secundum atrial septal defect (ASD) closure using the Amplatzer septal occluder (ASO). Therefore, the aim of this study was to prospectively perform ambulatory ECG monitoring to assess the electrocardiographic effects of transcatheter closure (TCC) of ASD using the ASO device. From 5/97 to 3/99, 41 patients with secundum ASD, underwent TCC using the ASO device at a median age of 9.2[emsp4 ]y. (0.5-87[emsp4 ]y.) and median weight of 34[emsp4 ]kg (5. 6-88[emsp4 ]kg.). Ambulatory Holter monitoring was performed pre- and immediately post TCC. Holter analysis included heart rate (HR), ECG intervals, supraventricular ectopy (SVE), ventricular ectopy (VE), and AV block. No change in baseline rhythm was noted in 37 patients (90%). Changes in AV conduction occurred in 3 patients (7%), including intermittent second degree AV block type II, and complete AV dissociation post closure. SVE was noted in 26 patients (63%) post closure, ranging from 5-2207 supraventricular premature beats (SVPB), including 9 patients (23%) with non-sustained supraventricular tachycardia (SVT), 3 of whom had short runs of SVT prior to closure. A significant increase in post-closure number of SVPB per hour (p=0.047) was noted. No significant difference was noted in PR interval, ventricular premature beats per hour, or QRS duration.
Based on ambulatory ECG analysis, TCC of ASD with the ASO device is associated with an acute increase in SVE and a small risk of AV conduction abnormalities, including complete heart block. Long term follow-up studies will be necessary to determine late arrhythmia prevalence and relative frequency compared with standard surgical ASD repair. |
doi_str_mv | 10.1023/A:1009852312907 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_72358402</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72358402</sourcerecordid><originalsourceid>FETCH-LOGICAL-c355t-958f3981f50d6f4fcf48ce9075aa9bf0ce98fa58f95cd00c834351535bfb27b63</originalsourceid><addsrcrecordid>eNpd0EFLwzAUB_AgitPp2ZsEEW_VpGna1NsYcwoDLwreymuauIy0nUmKTPxMfgg_mQE3BE_vHX78ee-P0Bkl15Sk7GZySwkpBU8ZTUtS7KEjyos0Ebzk-3FngiWi4C8jdOz9ikRK0vwQjSglWU5FdoQ-Z-DsBs-mcwx117sWrAlGeQze99JAUA1-N2GJg4POSwhLFZTD0vZ-cAr3GkNwBiz2ah3iaJRWMng8eNO94qjxpF1bCB_KfX_tUC-lHRrlTtCBBuvV6XaO0fPd7Gl6nywe5w_TySKRjPOQlFxoVgqqOWlynWmpMyFVfJcDlLUmcRcaIiq5bAiRgmWMU854reu0qHM2Rle_uWvXvw3Kh6o1XiproVP94KsiZVxksc8xuvgHV_3gunhblVJRxtQ8i-h8i4a6VU21dqYFt6l2pUZwuQUQG7M6NieN_3OE0pwQ9gOJP4gV</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>218935164</pqid></control><display><type>article</type><title>Early ECG abnormalities associated with transcatheter closure of atrial septal defects using the Amplatzer® septal occluder</title><source>MEDLINE</source><source>Springer Nature - Complete Springer Journals</source><creator>HILL, Sharon L ; BERUL, Charles I ; PATEL, Hitendra T ; RHODES, Jonathan ; SUPRAN, Stacey E ; CAO, Qi-Ling ; HIJAZI, Ziyad M</creator><creatorcontrib>HILL, Sharon L ; BERUL, Charles I ; PATEL, Hitendra T ; RHODES, Jonathan ; SUPRAN, Stacey E ; CAO, Qi-Ling ; HIJAZI, Ziyad M</creatorcontrib><description>Conduction abnormalities and arrhythmias may occur in patients following secundum atrial septal defect (ASD) closure using the Amplatzer septal occluder (ASO). Therefore, the aim of this study was to prospectively perform ambulatory ECG monitoring to assess the electrocardiographic effects of transcatheter closure (TCC) of ASD using the ASO device. From 5/97 to 3/99, 41 patients with secundum ASD, underwent TCC using the ASO device at a median age of 9.2[emsp4 ]y. (0.5-87[emsp4 ]y.) and median weight of 34[emsp4 ]kg (5. 6-88[emsp4 ]kg.). Ambulatory Holter monitoring was performed pre- and immediately post TCC. Holter analysis included heart rate (HR), ECG intervals, supraventricular ectopy (SVE), ventricular ectopy (VE), and AV block. No change in baseline rhythm was noted in 37 patients (90%). Changes in AV conduction occurred in 3 patients (7%), including intermittent second degree AV block type II, and complete AV dissociation post closure. SVE was noted in 26 patients (63%) post closure, ranging from 5-2207 supraventricular premature beats (SVPB), including 9 patients (23%) with non-sustained supraventricular tachycardia (SVT), 3 of whom had short runs of SVT prior to closure. A significant increase in post-closure number of SVPB per hour (p=0.047) was noted. No significant difference was noted in PR interval, ventricular premature beats per hour, or QRS duration.
Based on ambulatory ECG analysis, TCC of ASD with the ASO device is associated with an acute increase in SVE and a small risk of AV conduction abnormalities, including complete heart block. Long term follow-up studies will be necessary to determine late arrhythmia prevalence and relative frequency compared with standard surgical ASD repair.</description><identifier>ISSN: 1383-875X</identifier><identifier>EISSN: 1572-8595</identifier><identifier>DOI: 10.1023/A:1009852312907</identifier><identifier>PMID: 11046184</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Adolescent ; Analysis of Variance ; Arrhythmias, Cardiac - diagnosis ; Arrhythmias, Cardiac - etiology ; Biological and medical sciences ; Cardiac Catheterization - adverse effects ; Cardiac Catheterization - instrumentation ; Cardiac Catheterization - methods ; Chi-Square Distribution ; Child ; Child, Preschool ; Diseases of the cardiovascular system ; Echocardiography, Transesophageal ; Electrocardiography, Ambulatory ; Female ; Heart Septal Defects, Atrial - diagnosis ; Heart Septal Defects, Atrial - therapy ; Humans ; Infant ; Linear Models ; Male ; Medical sciences ; Multivariate Analysis ; Postoperative Complications - diagnosis ; Prospective Studies ; Prosthesis Implantation - adverse effects ; Prosthesis Implantation - methods ; Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects) ; Sensitivity and Specificity</subject><ispartof>Journal of interventional cardiac electrophysiology, 2000-10, Vol.4 (3), p.469-474</ispartof><rights>2001 INIST-CNRS</rights><rights>Copyright Kluwer Academic Publishers Oct 2000</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c355t-958f3981f50d6f4fcf48ce9075aa9bf0ce98fa58f95cd00c834351535bfb27b63</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1011600$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11046184$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>HILL, Sharon L</creatorcontrib><creatorcontrib>BERUL, Charles I</creatorcontrib><creatorcontrib>PATEL, Hitendra T</creatorcontrib><creatorcontrib>RHODES, Jonathan</creatorcontrib><creatorcontrib>SUPRAN, Stacey E</creatorcontrib><creatorcontrib>CAO, Qi-Ling</creatorcontrib><creatorcontrib>HIJAZI, Ziyad M</creatorcontrib><title>Early ECG abnormalities associated with transcatheter closure of atrial septal defects using the Amplatzer® septal occluder</title><title>Journal of interventional cardiac electrophysiology</title><addtitle>J Interv Card Electrophysiol</addtitle><description>Conduction abnormalities and arrhythmias may occur in patients following secundum atrial septal defect (ASD) closure using the Amplatzer septal occluder (ASO). Therefore, the aim of this study was to prospectively perform ambulatory ECG monitoring to assess the electrocardiographic effects of transcatheter closure (TCC) of ASD using the ASO device. From 5/97 to 3/99, 41 patients with secundum ASD, underwent TCC using the ASO device at a median age of 9.2[emsp4 ]y. (0.5-87[emsp4 ]y.) and median weight of 34[emsp4 ]kg (5. 6-88[emsp4 ]kg.). Ambulatory Holter monitoring was performed pre- and immediately post TCC. Holter analysis included heart rate (HR), ECG intervals, supraventricular ectopy (SVE), ventricular ectopy (VE), and AV block. No change in baseline rhythm was noted in 37 patients (90%). Changes in AV conduction occurred in 3 patients (7%), including intermittent second degree AV block type II, and complete AV dissociation post closure. SVE was noted in 26 patients (63%) post closure, ranging from 5-2207 supraventricular premature beats (SVPB), including 9 patients (23%) with non-sustained supraventricular tachycardia (SVT), 3 of whom had short runs of SVT prior to closure. A significant increase in post-closure number of SVPB per hour (p=0.047) was noted. No significant difference was noted in PR interval, ventricular premature beats per hour, or QRS duration.
Based on ambulatory ECG analysis, TCC of ASD with the ASO device is associated with an acute increase in SVE and a small risk of AV conduction abnormalities, including complete heart block. Long term follow-up studies will be necessary to determine late arrhythmia prevalence and relative frequency compared with standard surgical ASD repair.</description><subject>Adolescent</subject><subject>Analysis of Variance</subject><subject>Arrhythmias, Cardiac - diagnosis</subject><subject>Arrhythmias, Cardiac - etiology</subject><subject>Biological and medical sciences</subject><subject>Cardiac Catheterization - adverse effects</subject><subject>Cardiac Catheterization - instrumentation</subject><subject>Cardiac Catheterization - methods</subject><subject>Chi-Square Distribution</subject><subject>Child</subject><subject>Child, Preschool</subject><subject>Diseases of the cardiovascular system</subject><subject>Echocardiography, Transesophageal</subject><subject>Electrocardiography, Ambulatory</subject><subject>Female</subject><subject>Heart Septal Defects, Atrial - diagnosis</subject><subject>Heart Septal Defects, Atrial - therapy</subject><subject>Humans</subject><subject>Infant</subject><subject>Linear Models</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Multivariate Analysis</subject><subject>Postoperative Complications - diagnosis</subject><subject>Prospective Studies</subject><subject>Prosthesis Implantation - adverse effects</subject><subject>Prosthesis Implantation - methods</subject><subject>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</subject><subject>Sensitivity and Specificity</subject><issn>1383-875X</issn><issn>1572-8595</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>BENPR</sourceid><recordid>eNpd0EFLwzAUB_AgitPp2ZsEEW_VpGna1NsYcwoDLwreymuauIy0nUmKTPxMfgg_mQE3BE_vHX78ee-P0Bkl15Sk7GZySwkpBU8ZTUtS7KEjyos0Ebzk-3FngiWi4C8jdOz9ikRK0vwQjSglWU5FdoQ-Z-DsBs-mcwx117sWrAlGeQze99JAUA1-N2GJg4POSwhLFZTD0vZ-cAr3GkNwBiz2ah3iaJRWMng8eNO94qjxpF1bCB_KfX_tUC-lHRrlTtCBBuvV6XaO0fPd7Gl6nywe5w_TySKRjPOQlFxoVgqqOWlynWmpMyFVfJcDlLUmcRcaIiq5bAiRgmWMU854reu0qHM2Rle_uWvXvw3Kh6o1XiproVP94KsiZVxksc8xuvgHV_3gunhblVJRxtQ8i-h8i4a6VU21dqYFt6l2pUZwuQUQG7M6NieN_3OE0pwQ9gOJP4gV</recordid><startdate>20001001</startdate><enddate>20001001</enddate><creator>HILL, Sharon L</creator><creator>BERUL, Charles I</creator><creator>PATEL, Hitendra T</creator><creator>RHODES, Jonathan</creator><creator>SUPRAN, Stacey E</creator><creator>CAO, Qi-Ling</creator><creator>HIJAZI, Ziyad M</creator><general>Springer</general><general>Springer Nature B.V</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>3V.</scope><scope>7QO</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FD</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20001001</creationdate><title>Early ECG abnormalities associated with transcatheter closure of atrial septal defects using the Amplatzer® septal occluder</title><author>HILL, Sharon L ; BERUL, Charles I ; PATEL, Hitendra T ; RHODES, Jonathan ; SUPRAN, Stacey E ; CAO, Qi-Ling ; HIJAZI, Ziyad M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c355t-958f3981f50d6f4fcf48ce9075aa9bf0ce98fa58f95cd00c834351535bfb27b63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Adolescent</topic><topic>Analysis of Variance</topic><topic>Arrhythmias, Cardiac - diagnosis</topic><topic>Arrhythmias, Cardiac - etiology</topic><topic>Biological and medical sciences</topic><topic>Cardiac Catheterization - adverse effects</topic><topic>Cardiac Catheterization - instrumentation</topic><topic>Cardiac Catheterization - methods</topic><topic>Chi-Square Distribution</topic><topic>Child</topic><topic>Child, Preschool</topic><topic>Diseases of the cardiovascular system</topic><topic>Echocardiography, Transesophageal</topic><topic>Electrocardiography, Ambulatory</topic><topic>Female</topic><topic>Heart Septal Defects, Atrial - diagnosis</topic><topic>Heart Septal Defects, Atrial - therapy</topic><topic>Humans</topic><topic>Infant</topic><topic>Linear Models</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Multivariate Analysis</topic><topic>Postoperative Complications - diagnosis</topic><topic>Prospective Studies</topic><topic>Prosthesis Implantation - adverse effects</topic><topic>Prosthesis Implantation - methods</topic><topic>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>HILL, Sharon L</creatorcontrib><creatorcontrib>BERUL, Charles I</creatorcontrib><creatorcontrib>PATEL, Hitendra T</creatorcontrib><creatorcontrib>RHODES, Jonathan</creatorcontrib><creatorcontrib>SUPRAN, Stacey E</creatorcontrib><creatorcontrib>CAO, Qi-Ling</creatorcontrib><creatorcontrib>HIJAZI, Ziyad M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>ProQuest Central (Corporate)</collection><collection>Biotechnology Research Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of interventional cardiac electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>HILL, Sharon L</au><au>BERUL, Charles I</au><au>PATEL, Hitendra T</au><au>RHODES, Jonathan</au><au>SUPRAN, Stacey E</au><au>CAO, Qi-Ling</au><au>HIJAZI, Ziyad M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Early ECG abnormalities associated with transcatheter closure of atrial septal defects using the Amplatzer® septal occluder</atitle><jtitle>Journal of interventional cardiac electrophysiology</jtitle><addtitle>J Interv Card Electrophysiol</addtitle><date>2000-10-01</date><risdate>2000</risdate><volume>4</volume><issue>3</issue><spage>469</spage><epage>474</epage><pages>469-474</pages><issn>1383-875X</issn><eissn>1572-8595</eissn><abstract>Conduction abnormalities and arrhythmias may occur in patients following secundum atrial septal defect (ASD) closure using the Amplatzer septal occluder (ASO). Therefore, the aim of this study was to prospectively perform ambulatory ECG monitoring to assess the electrocardiographic effects of transcatheter closure (TCC) of ASD using the ASO device. From 5/97 to 3/99, 41 patients with secundum ASD, underwent TCC using the ASO device at a median age of 9.2[emsp4 ]y. (0.5-87[emsp4 ]y.) and median weight of 34[emsp4 ]kg (5. 6-88[emsp4 ]kg.). Ambulatory Holter monitoring was performed pre- and immediately post TCC. Holter analysis included heart rate (HR), ECG intervals, supraventricular ectopy (SVE), ventricular ectopy (VE), and AV block. No change in baseline rhythm was noted in 37 patients (90%). Changes in AV conduction occurred in 3 patients (7%), including intermittent second degree AV block type II, and complete AV dissociation post closure. SVE was noted in 26 patients (63%) post closure, ranging from 5-2207 supraventricular premature beats (SVPB), including 9 patients (23%) with non-sustained supraventricular tachycardia (SVT), 3 of whom had short runs of SVT prior to closure. A significant increase in post-closure number of SVPB per hour (p=0.047) was noted. No significant difference was noted in PR interval, ventricular premature beats per hour, or QRS duration.
Based on ambulatory ECG analysis, TCC of ASD with the ASO device is associated with an acute increase in SVE and a small risk of AV conduction abnormalities, including complete heart block. Long term follow-up studies will be necessary to determine late arrhythmia prevalence and relative frequency compared with standard surgical ASD repair.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>11046184</pmid><doi>10.1023/A:1009852312907</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1383-875X |
ispartof | Journal of interventional cardiac electrophysiology, 2000-10, Vol.4 (3), p.469-474 |
issn | 1383-875X 1572-8595 |
language | eng |
recordid | cdi_proquest_miscellaneous_72358402 |
source | MEDLINE; Springer Nature - Complete Springer Journals |
subjects | Adolescent Analysis of Variance Arrhythmias, Cardiac - diagnosis Arrhythmias, Cardiac - etiology Biological and medical sciences Cardiac Catheterization - adverse effects Cardiac Catheterization - instrumentation Cardiac Catheterization - methods Chi-Square Distribution Child Child, Preschool Diseases of the cardiovascular system Echocardiography, Transesophageal Electrocardiography, Ambulatory Female Heart Septal Defects, Atrial - diagnosis Heart Septal Defects, Atrial - therapy Humans Infant Linear Models Male Medical sciences Multivariate Analysis Postoperative Complications - diagnosis Prospective Studies Prosthesis Implantation - adverse effects Prosthesis Implantation - methods Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects) Sensitivity and Specificity |
title | Early ECG abnormalities associated with transcatheter closure of atrial septal defects using the Amplatzer® septal occluder |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-18T13%3A57%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Early%20ECG%20abnormalities%20associated%20with%20transcatheter%20closure%20of%20atrial%20septal%20defects%20using%20the%20Amplatzer%C2%AE%20septal%20occluder&rft.jtitle=Journal%20of%20interventional%20cardiac%20electrophysiology&rft.au=HILL,%20Sharon%20L&rft.date=2000-10-01&rft.volume=4&rft.issue=3&rft.spage=469&rft.epage=474&rft.pages=469-474&rft.issn=1383-875X&rft.eissn=1572-8595&rft_id=info:doi/10.1023/A:1009852312907&rft_dat=%3Cproquest_pubme%3E72358402%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=218935164&rft_id=info:pmid/11046184&rfr_iscdi=true |