Graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware : Collaborative study
A modification of the official flame atomic absorption spectrometric (FAAS) method for determining lead and cadmium extracted from ceramic foodware was collaboratively studied. In the modified method, graphite furnace atomic absorption spectrometry (GFAAS) is substituted for FAAS. The modified metho...
Gespeichert in:
Veröffentlicht in: | Journal of AOAC International 2000-09, Vol.83 (5), p.1174-1188 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1188 |
---|---|
container_issue | 5 |
container_start_page | 1174 |
container_title | Journal of AOAC International |
container_volume | 83 |
creator | HIGHT, Susan C |
description | A modification of the official flame atomic absorption spectrometric (FAAS) method for determining lead and cadmium extracted from ceramic foodware was collaboratively studied. In the modified method, graphite furnace atomic absorption spectrometry (GFAAS) is substituted for FAAS. The modified method also includes mandatory quality control procedures to improve method performance. The extraction procedure of the official method (leaching with 4% acetic acid for 24 h at room temperature) remains unchanged. Seven laboratories analyzed blind duplicate portions of 3 ceramicware leach solutions containing Pb at concentrations of 0.0196, 0.403, and 3.73 microg/mL and Cd at concentrations of 0.00236, 0.0456, and 0.544 microg/mL. Performance of the modified method compared well with that of the official method. The repeatability relative standard deviation (RSDr) ranged from 0.87 to 6.7% for Pb and from 3.7 to 11% for Cd. The reproducibility relative standard deviation (RSDR) ranged from 4.5 to 12% for Pb and from 7.0 to 11% for Cd. Accuracy of collaborator results was 97-98% for Pb and 93-101% for Cd. Quality control results and quantitation limits were excellent. Method quantitation limits varied among laboratories from 0.005 to 0.019 microg/mL for Pb and from 0.0004 to 0.0019 microg/mL for Cd. The modified method was adopted First Action by AOAC INTERNATIONAL. |
doi_str_mv | 10.1093/jaoac/83.5.1174 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72357908</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72357908</sourcerecordid><originalsourceid>FETCH-LOGICAL-c428t-a35297c703b67f63be5c84670d53c0a88966c7bed47f5c353b53ba8a4a9da6cf3</originalsourceid><addsrcrecordid>eNpFkF9rFTEQxYMotlaffZOA0Le9N9ls_qxvcqlVKPhin8NsMsEtu5s1yWr7DfqxzW0vCgMzcH7nMBxC3nO246wX-zuI4PZG7OSOc929IOe877pG9237st5MsUa0mp-RNznfMdZxxdrX5Ixz1hkj-3PyeJ1g_TkWpGFLCzikUOI8OgpDjmktY1xoXtGVFGcsqQoeC6Z5XOBJi4FOCJ7C4qkDP4_bTPG-JHAFPQ3VRR0mOCaGGP0fSEg_0UOcJhhiqhm_keay-Ye35FWAKeO7074gt1-ufhy-Njffr78dPt80rmtNaUDIttdOMzEoHZQYUDrTKc28FI6BMb1STg_oOx2kE1IMdcBAB70H5YK4IJfPuWuKvzbMxc5jdlj_WTBu2epWSN0zU8H9M-hSzDlhsGsaZ0gPljN7LN8-lW-NsNIey6-OD6fobZjR_-dPbVfg4wmA7GAKCRY35n-cYa3qlfgLwQWRBA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72357908</pqid></control><display><type>article</type><title>Graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware : Collaborative study</title><source>MEDLINE</source><source>Oxford University Press Journals All Titles (1996-Current)</source><creator>HIGHT, Susan C</creator><creatorcontrib>HIGHT, Susan C ; Collaborators</creatorcontrib><description>A modification of the official flame atomic absorption spectrometric (FAAS) method for determining lead and cadmium extracted from ceramic foodware was collaboratively studied. In the modified method, graphite furnace atomic absorption spectrometry (GFAAS) is substituted for FAAS. The modified method also includes mandatory quality control procedures to improve method performance. The extraction procedure of the official method (leaching with 4% acetic acid for 24 h at room temperature) remains unchanged. Seven laboratories analyzed blind duplicate portions of 3 ceramicware leach solutions containing Pb at concentrations of 0.0196, 0.403, and 3.73 microg/mL and Cd at concentrations of 0.00236, 0.0456, and 0.544 microg/mL. Performance of the modified method compared well with that of the official method. The repeatability relative standard deviation (RSDr) ranged from 0.87 to 6.7% for Pb and from 3.7 to 11% for Cd. The reproducibility relative standard deviation (RSDR) ranged from 4.5 to 12% for Pb and from 7.0 to 11% for Cd. Accuracy of collaborator results was 97-98% for Pb and 93-101% for Cd. Quality control results and quantitation limits were excellent. Method quantitation limits varied among laboratories from 0.005 to 0.019 microg/mL for Pb and from 0.0004 to 0.0019 microg/mL for Cd. The modified method was adopted First Action by AOAC INTERNATIONAL.</description><identifier>ISSN: 1060-3271</identifier><identifier>EISSN: 1944-7922</identifier><identifier>DOI: 10.1093/jaoac/83.5.1174</identifier><identifier>PMID: 11048859</identifier><language>eng</language><publisher>Gaithersburg, MD: AOAC International</publisher><subject>Biological and medical sciences ; Cadmium - analysis ; Calibration ; Ceramics - analysis ; Filtration ; Food industries ; Food toxicology ; Fundamental and applied biological sciences. Psychology ; General aspects ; Indicators and Reagents ; Lead - analysis ; Methods of analysis, processing and quality control, regulation, standards ; Solutions ; Spectrophotometry, Atomic</subject><ispartof>Journal of AOAC International, 2000-09, Vol.83 (5), p.1174-1188</ispartof><rights>2001 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c428t-a35297c703b67f63be5c84670d53c0a88966c7bed47f5c353b53ba8a4a9da6cf3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=802696$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11048859$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>HIGHT, Susan C</creatorcontrib><creatorcontrib>Collaborators</creatorcontrib><title>Graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware : Collaborative study</title><title>Journal of AOAC International</title><addtitle>J AOAC Int</addtitle><description>A modification of the official flame atomic absorption spectrometric (FAAS) method for determining lead and cadmium extracted from ceramic foodware was collaboratively studied. In the modified method, graphite furnace atomic absorption spectrometry (GFAAS) is substituted for FAAS. The modified method also includes mandatory quality control procedures to improve method performance. The extraction procedure of the official method (leaching with 4% acetic acid for 24 h at room temperature) remains unchanged. Seven laboratories analyzed blind duplicate portions of 3 ceramicware leach solutions containing Pb at concentrations of 0.0196, 0.403, and 3.73 microg/mL and Cd at concentrations of 0.00236, 0.0456, and 0.544 microg/mL. Performance of the modified method compared well with that of the official method. The repeatability relative standard deviation (RSDr) ranged from 0.87 to 6.7% for Pb and from 3.7 to 11% for Cd. The reproducibility relative standard deviation (RSDR) ranged from 4.5 to 12% for Pb and from 7.0 to 11% for Cd. Accuracy of collaborator results was 97-98% for Pb and 93-101% for Cd. Quality control results and quantitation limits were excellent. Method quantitation limits varied among laboratories from 0.005 to 0.019 microg/mL for Pb and from 0.0004 to 0.0019 microg/mL for Cd. The modified method was adopted First Action by AOAC INTERNATIONAL.</description><subject>Biological and medical sciences</subject><subject>Cadmium - analysis</subject><subject>Calibration</subject><subject>Ceramics - analysis</subject><subject>Filtration</subject><subject>Food industries</subject><subject>Food toxicology</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General aspects</subject><subject>Indicators and Reagents</subject><subject>Lead - analysis</subject><subject>Methods of analysis, processing and quality control, regulation, standards</subject><subject>Solutions</subject><subject>Spectrophotometry, Atomic</subject><issn>1060-3271</issn><issn>1944-7922</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkF9rFTEQxYMotlaffZOA0Le9N9ls_qxvcqlVKPhin8NsMsEtu5s1yWr7DfqxzW0vCgMzcH7nMBxC3nO246wX-zuI4PZG7OSOc929IOe877pG9237st5MsUa0mp-RNznfMdZxxdrX5Ixz1hkj-3PyeJ1g_TkWpGFLCzikUOI8OgpDjmktY1xoXtGVFGcsqQoeC6Z5XOBJi4FOCJ7C4qkDP4_bTPG-JHAFPQ3VRR0mOCaGGP0fSEg_0UOcJhhiqhm_keay-Ye35FWAKeO7074gt1-ufhy-Njffr78dPt80rmtNaUDIttdOMzEoHZQYUDrTKc28FI6BMb1STg_oOx2kE1IMdcBAB70H5YK4IJfPuWuKvzbMxc5jdlj_WTBu2epWSN0zU8H9M-hSzDlhsGsaZ0gPljN7LN8-lW-NsNIey6-OD6fobZjR_-dPbVfg4wmA7GAKCRY35n-cYa3qlfgLwQWRBA</recordid><startdate>20000901</startdate><enddate>20000901</enddate><creator>HIGHT, Susan C</creator><general>AOAC International</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20000901</creationdate><title>Graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware : Collaborative study</title><author>HIGHT, Susan C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c428t-a35297c703b67f63be5c84670d53c0a88966c7bed47f5c353b53ba8a4a9da6cf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Biological and medical sciences</topic><topic>Cadmium - analysis</topic><topic>Calibration</topic><topic>Ceramics - analysis</topic><topic>Filtration</topic><topic>Food industries</topic><topic>Food toxicology</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General aspects</topic><topic>Indicators and Reagents</topic><topic>Lead - analysis</topic><topic>Methods of analysis, processing and quality control, regulation, standards</topic><topic>Solutions</topic><topic>Spectrophotometry, Atomic</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>HIGHT, Susan C</creatorcontrib><creatorcontrib>Collaborators</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of AOAC International</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>HIGHT, Susan C</au><aucorp>Collaborators</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware : Collaborative study</atitle><jtitle>Journal of AOAC International</jtitle><addtitle>J AOAC Int</addtitle><date>2000-09-01</date><risdate>2000</risdate><volume>83</volume><issue>5</issue><spage>1174</spage><epage>1188</epage><pages>1174-1188</pages><issn>1060-3271</issn><eissn>1944-7922</eissn><abstract>A modification of the official flame atomic absorption spectrometric (FAAS) method for determining lead and cadmium extracted from ceramic foodware was collaboratively studied. In the modified method, graphite furnace atomic absorption spectrometry (GFAAS) is substituted for FAAS. The modified method also includes mandatory quality control procedures to improve method performance. The extraction procedure of the official method (leaching with 4% acetic acid for 24 h at room temperature) remains unchanged. Seven laboratories analyzed blind duplicate portions of 3 ceramicware leach solutions containing Pb at concentrations of 0.0196, 0.403, and 3.73 microg/mL and Cd at concentrations of 0.00236, 0.0456, and 0.544 microg/mL. Performance of the modified method compared well with that of the official method. The repeatability relative standard deviation (RSDr) ranged from 0.87 to 6.7% for Pb and from 3.7 to 11% for Cd. The reproducibility relative standard deviation (RSDR) ranged from 4.5 to 12% for Pb and from 7.0 to 11% for Cd. Accuracy of collaborator results was 97-98% for Pb and 93-101% for Cd. Quality control results and quantitation limits were excellent. Method quantitation limits varied among laboratories from 0.005 to 0.019 microg/mL for Pb and from 0.0004 to 0.0019 microg/mL for Cd. The modified method was adopted First Action by AOAC INTERNATIONAL.</abstract><cop>Gaithersburg, MD</cop><pub>AOAC International</pub><pmid>11048859</pmid><doi>10.1093/jaoac/83.5.1174</doi><tpages>15</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1060-3271 |
ispartof | Journal of AOAC International, 2000-09, Vol.83 (5), p.1174-1188 |
issn | 1060-3271 1944-7922 |
language | eng |
recordid | cdi_proquest_miscellaneous_72357908 |
source | MEDLINE; Oxford University Press Journals All Titles (1996-Current) |
subjects | Biological and medical sciences Cadmium - analysis Calibration Ceramics - analysis Filtration Food industries Food toxicology Fundamental and applied biological sciences. Psychology General aspects Indicators and Reagents Lead - analysis Methods of analysis, processing and quality control, regulation, standards Solutions Spectrophotometry, Atomic |
title | Graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware : Collaborative study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T00%3A47%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Graphite%20furnace%20atomic%20absorption%20spectrometric%20determination%20of%20lead%20and%20cadmium%20extracted%20from%20ceramic%20foodware%20:%20Collaborative%20study&rft.jtitle=Journal%20of%20AOAC%20International&rft.au=HIGHT,%20Susan%20C&rft.aucorp=Collaborators&rft.date=2000-09-01&rft.volume=83&rft.issue=5&rft.spage=1174&rft.epage=1188&rft.pages=1174-1188&rft.issn=1060-3271&rft.eissn=1944-7922&rft_id=info:doi/10.1093/jaoac/83.5.1174&rft_dat=%3Cproquest_cross%3E72357908%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72357908&rft_id=info:pmid/11048859&rfr_iscdi=true |