Ash Split Cath in geriatric dialyzed patients

Vascular access is the essential step in performing hemodialysis in uremic patients. In the absence of a permanent and utilizable native arterio-venous fistula, the use of a tunnelled catheter makes dialysis therapy possible. The Ash Split Cath, a recently introduced chronic hemodialysis catheter, w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of artificial organs 2001-09, Vol.24 (9), p.663-665
Hauptverfasser: Conz, P A, Catalano, C, Rizzioli, E, Normanno, M, Fabbian, F, Preciso, G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 665
container_issue 9
container_start_page 663
container_title International journal of artificial organs
container_volume 24
creator Conz, P A
Catalano, C
Rizzioli, E
Normanno, M
Fabbian, F
Preciso, G
description Vascular access is the essential step in performing hemodialysis in uremic patients. In the absence of a permanent and utilizable native arterio-venous fistula, the use of a tunnelled catheter makes dialysis therapy possible. The Ash Split Cath, a recently introduced chronic hemodialysis catheter, was inserted in five patients (7.1% of our prevalent dialysis population) because of repeated venous thrombosis in three patients and a poor venous tree in two. The mean age of patients was 78 years +/- 7. The average blood flow rate was 250+/-50 ml/minute and the mean venous pressure 140mm Hg +/- 35. Recirculation determined by low flux technique was less than 2%. KT/V calculated 3 months after the catheter placement was 1.2+/-0.02. During the follow-up we did not document any infection of the exit site or related to the catheter. This device is simple to place, gives adequate dialysis treatment and is useful in geriatric dialyzed patients in whom the arterio-venous fistula can no longer be used.
doi_str_mv 10.1177/039139880102400903
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72245433</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72245433</sourcerecordid><originalsourceid>FETCH-LOGICAL-c299t-5bc6fb70fe5f8e0c01102db87ff8e8afd0d9683a32bf99dc50a2edc97c9231e03</originalsourceid><addsrcrecordid>eNplkEtLAzEUhYMotlb_gAuZlbvRm8dMJstSfEHBhboeMsmNjczLJF3UX--UFly4uhz4zuHyEXJN4Y5SKe-BK8pVVQEFJgAU8BMyp5KJvAQBp2S-B_I9MSMXMX4B0FKI4pzMKC0VF0zMSb6Mm-xtbH3KVjptMt9nnxi8TsGbzHrd7n7QZqNOHvsUL8mZ023Eq-NdkI_Hh_fVc75-fXpZLde5YUqlvGhM6RoJDgtXIRig04e2qaSbYqWdBavKimvOGqeUNQVohtYoaRTjFIEvyO1hdwzD9xZjqjsfDbat7nHYxloyJgrB-QSyA2jCEGNAV4_Bdzrsagr1XlL9X9JUujmub5sO7V_laIX_AiKeYN4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72245433</pqid></control><display><type>article</type><title>Ash Split Cath in geriatric dialyzed patients</title><source>MEDLINE</source><source>SAGE Complete</source><creator>Conz, P A ; Catalano, C ; Rizzioli, E ; Normanno, M ; Fabbian, F ; Preciso, G</creator><creatorcontrib>Conz, P A ; Catalano, C ; Rizzioli, E ; Normanno, M ; Fabbian, F ; Preciso, G</creatorcontrib><description>Vascular access is the essential step in performing hemodialysis in uremic patients. In the absence of a permanent and utilizable native arterio-venous fistula, the use of a tunnelled catheter makes dialysis therapy possible. The Ash Split Cath, a recently introduced chronic hemodialysis catheter, was inserted in five patients (7.1% of our prevalent dialysis population) because of repeated venous thrombosis in three patients and a poor venous tree in two. The mean age of patients was 78 years +/- 7. The average blood flow rate was 250+/-50 ml/minute and the mean venous pressure 140mm Hg +/- 35. Recirculation determined by low flux technique was less than 2%. KT/V calculated 3 months after the catheter placement was 1.2+/-0.02. During the follow-up we did not document any infection of the exit site or related to the catheter. This device is simple to place, gives adequate dialysis treatment and is useful in geriatric dialyzed patients in whom the arterio-venous fistula can no longer be used.</description><identifier>ISSN: 0391-3988</identifier><identifier>EISSN: 1724-6040</identifier><identifier>DOI: 10.1177/039139880102400903</identifier><identifier>PMID: 11693424</identifier><language>eng</language><publisher>United States</publisher><subject>Aged ; Aged, 80 and over ; Catheters, Indwelling ; Equipment Design ; Humans ; Renal Dialysis - instrumentation ; Venous Pressure</subject><ispartof>International journal of artificial organs, 2001-09, Vol.24 (9), p.663-665</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c299t-5bc6fb70fe5f8e0c01102db87ff8e8afd0d9683a32bf99dc50a2edc97c9231e03</citedby><cites>FETCH-LOGICAL-c299t-5bc6fb70fe5f8e0c01102db87ff8e8afd0d9683a32bf99dc50a2edc97c9231e03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11693424$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Conz, P A</creatorcontrib><creatorcontrib>Catalano, C</creatorcontrib><creatorcontrib>Rizzioli, E</creatorcontrib><creatorcontrib>Normanno, M</creatorcontrib><creatorcontrib>Fabbian, F</creatorcontrib><creatorcontrib>Preciso, G</creatorcontrib><title>Ash Split Cath in geriatric dialyzed patients</title><title>International journal of artificial organs</title><addtitle>Int J Artif Organs</addtitle><description>Vascular access is the essential step in performing hemodialysis in uremic patients. In the absence of a permanent and utilizable native arterio-venous fistula, the use of a tunnelled catheter makes dialysis therapy possible. The Ash Split Cath, a recently introduced chronic hemodialysis catheter, was inserted in five patients (7.1% of our prevalent dialysis population) because of repeated venous thrombosis in three patients and a poor venous tree in two. The mean age of patients was 78 years +/- 7. The average blood flow rate was 250+/-50 ml/minute and the mean venous pressure 140mm Hg +/- 35. Recirculation determined by low flux technique was less than 2%. KT/V calculated 3 months after the catheter placement was 1.2+/-0.02. During the follow-up we did not document any infection of the exit site or related to the catheter. This device is simple to place, gives adequate dialysis treatment and is useful in geriatric dialyzed patients in whom the arterio-venous fistula can no longer be used.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>Catheters, Indwelling</subject><subject>Equipment Design</subject><subject>Humans</subject><subject>Renal Dialysis - instrumentation</subject><subject>Venous Pressure</subject><issn>0391-3988</issn><issn>1724-6040</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNplkEtLAzEUhYMotlb_gAuZlbvRm8dMJstSfEHBhboeMsmNjczLJF3UX--UFly4uhz4zuHyEXJN4Y5SKe-BK8pVVQEFJgAU8BMyp5KJvAQBp2S-B_I9MSMXMX4B0FKI4pzMKC0VF0zMSb6Mm-xtbH3KVjptMt9nnxi8TsGbzHrd7n7QZqNOHvsUL8mZ023Eq-NdkI_Hh_fVc75-fXpZLde5YUqlvGhM6RoJDgtXIRig04e2qaSbYqWdBavKimvOGqeUNQVohtYoaRTjFIEvyO1hdwzD9xZjqjsfDbat7nHYxloyJgrB-QSyA2jCEGNAV4_Bdzrsagr1XlL9X9JUujmub5sO7V_laIX_AiKeYN4</recordid><startdate>20010901</startdate><enddate>20010901</enddate><creator>Conz, P A</creator><creator>Catalano, C</creator><creator>Rizzioli, E</creator><creator>Normanno, M</creator><creator>Fabbian, F</creator><creator>Preciso, G</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20010901</creationdate><title>Ash Split Cath in geriatric dialyzed patients</title><author>Conz, P A ; Catalano, C ; Rizzioli, E ; Normanno, M ; Fabbian, F ; Preciso, G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c299t-5bc6fb70fe5f8e0c01102db87ff8e8afd0d9683a32bf99dc50a2edc97c9231e03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>Catheters, Indwelling</topic><topic>Equipment Design</topic><topic>Humans</topic><topic>Renal Dialysis - instrumentation</topic><topic>Venous Pressure</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Conz, P A</creatorcontrib><creatorcontrib>Catalano, C</creatorcontrib><creatorcontrib>Rizzioli, E</creatorcontrib><creatorcontrib>Normanno, M</creatorcontrib><creatorcontrib>Fabbian, F</creatorcontrib><creatorcontrib>Preciso, G</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of artificial organs</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Conz, P A</au><au>Catalano, C</au><au>Rizzioli, E</au><au>Normanno, M</au><au>Fabbian, F</au><au>Preciso, G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ash Split Cath in geriatric dialyzed patients</atitle><jtitle>International journal of artificial organs</jtitle><addtitle>Int J Artif Organs</addtitle><date>2001-09-01</date><risdate>2001</risdate><volume>24</volume><issue>9</issue><spage>663</spage><epage>665</epage><pages>663-665</pages><issn>0391-3988</issn><eissn>1724-6040</eissn><abstract>Vascular access is the essential step in performing hemodialysis in uremic patients. In the absence of a permanent and utilizable native arterio-venous fistula, the use of a tunnelled catheter makes dialysis therapy possible. The Ash Split Cath, a recently introduced chronic hemodialysis catheter, was inserted in five patients (7.1% of our prevalent dialysis population) because of repeated venous thrombosis in three patients and a poor venous tree in two. The mean age of patients was 78 years +/- 7. The average blood flow rate was 250+/-50 ml/minute and the mean venous pressure 140mm Hg +/- 35. Recirculation determined by low flux technique was less than 2%. KT/V calculated 3 months after the catheter placement was 1.2+/-0.02. During the follow-up we did not document any infection of the exit site or related to the catheter. This device is simple to place, gives adequate dialysis treatment and is useful in geriatric dialyzed patients in whom the arterio-venous fistula can no longer be used.</abstract><cop>United States</cop><pmid>11693424</pmid><doi>10.1177/039139880102400903</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0391-3988
ispartof International journal of artificial organs, 2001-09, Vol.24 (9), p.663-665
issn 0391-3988
1724-6040
language eng
recordid cdi_proquest_miscellaneous_72245433
source MEDLINE; SAGE Complete
subjects Aged
Aged, 80 and over
Catheters, Indwelling
Equipment Design
Humans
Renal Dialysis - instrumentation
Venous Pressure
title Ash Split Cath in geriatric dialyzed patients
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T11%3A09%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ash%20Split%20Cath%20in%20geriatric%20dialyzed%20patients&rft.jtitle=International%20journal%20of%20artificial%20organs&rft.au=Conz,%20P%20A&rft.date=2001-09-01&rft.volume=24&rft.issue=9&rft.spage=663&rft.epage=665&rft.pages=663-665&rft.issn=0391-3988&rft.eissn=1724-6040&rft_id=info:doi/10.1177/039139880102400903&rft_dat=%3Cproquest_cross%3E72245433%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72245433&rft_id=info:pmid/11693424&rfr_iscdi=true