A simple, isocratic high-performance liquid chromatography assay for linezolid in human serum

A rapid high-performance liquid chromatography (HPLC) assay for the detection of linezolid in human serum was developed. The method used a Hypersil 5ODS stationary phase. The mobile phase was 1% ortho-phosphoric acid, 30% methanol, 2 g/L heptane sulphonic acid, pH 5. UV absorbance detection was used...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of antimicrobial chemotherapy 2001-11, Vol.48 (5), p.605-608
Hauptverfasser: Tobin, C. M., Sunderland, J., White, L. O., MacGowan, A. P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 608
container_issue 5
container_start_page 605
container_title Journal of antimicrobial chemotherapy
container_volume 48
creator Tobin, C. M.
Sunderland, J.
White, L. O.
MacGowan, A. P.
description A rapid high-performance liquid chromatography (HPLC) assay for the detection of linezolid in human serum was developed. The method used a Hypersil 5ODS stationary phase. The mobile phase was 1% ortho-phosphoric acid, 30% methanol, 2 g/L heptane sulphonic acid, pH 5. UV absorbance detection was used (Ïmax 254 nm). Samples were prepared by mixing with acetonitrile and an injection volume of 20 ÌL was used. The inter- and intra-day assay reproducibility were assessed. Assay linearity, specificity and accuracy were investigated. The detection limit and recovery of linezolid from serum were determined. In addition, the stability of linezolid, stored under a variety of conditions, was assessed. The retention time of linezolid was c. 6.5 min. The intra- and inter-day reproducibility was good and the assay was linear across the therapeutic range. Serum recovery was c. 100% at all concentrations tested. The detection limit was 0.1 mg/L and the assay was accurate. The assay was specific as there was no significant interference with the linezolid peak. Linezolid was demonstrated to be stable. This rapid assay is ideal for busy clinical laboratories with basic HPLC equipment.
doi_str_mv 10.1093/jac/48.5.605
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72230639</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>373966391</sourcerecordid><originalsourceid>FETCH-LOGICAL-c486t-6359846fa55f56a2ba8f4b981f84c9abb6bed13471d89aed52b64a25eba176623</originalsourceid><addsrcrecordid>eNpd0E1r3DAQBmBRGppt2lvPRRTSU7yRrA9LxxCaLwK5JBAKRYxlOdbWthzJhm5_fRV2aSCnOcwzL8OL0BdK1pRodroBe8rVWqwlEe_QinJJipJo-h6tCCOiqLhgh-hjShtCiBRSfUCHlMpKC65W6NcZTn6YeneCfQo2wuwt7vxTV0wutiEOMFqHe_-8-AbbLoYB5vAUYeq2GFKCLc4o70f3N_SZ-BF3Sz7CycVl-IQOWuiT-7yfR-jh4sf9-VVxe3d5fX52W1iu5FxIJrTisgUhWiGhrEG1vNaKtopbDXUta9dQxivaKA2uEWUtOZTC1UArKUt2hL7vcqcYnheXZjP4ZF3fw-jCkkxVloxIpjP89gZuwhLH_Jspc1TFS80zOtkhG0NK0bVmin6AuDWUmJfOTe7ccGWEyZ1n_nWfudSDa17xvuQMjvcAkoW-jblTn14dJ4ox-hJU7JxPs_vzfw_xt5EVq4S5evxp5M2lvniUytyzf_hSmVM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217674294</pqid></control><display><type>article</type><title>A simple, isocratic high-performance liquid chromatography assay for linezolid in human serum</title><source>Oxford University Press Journals All Titles (1996-Current)</source><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Free Full-Text Journals in Chemistry</source><creator>Tobin, C. M. ; Sunderland, J. ; White, L. O. ; MacGowan, A. P.</creator><creatorcontrib>Tobin, C. M. ; Sunderland, J. ; White, L. O. ; MacGowan, A. P.</creatorcontrib><description>A rapid high-performance liquid chromatography (HPLC) assay for the detection of linezolid in human serum was developed. The method used a Hypersil 5ODS stationary phase. The mobile phase was 1% ortho-phosphoric acid, 30% methanol, 2 g/L heptane sulphonic acid, pH 5. UV absorbance detection was used (Ïmax 254 nm). Samples were prepared by mixing with acetonitrile and an injection volume of 20 ÌL was used. The inter- and intra-day assay reproducibility were assessed. Assay linearity, specificity and accuracy were investigated. The detection limit and recovery of linezolid from serum were determined. In addition, the stability of linezolid, stored under a variety of conditions, was assessed. The retention time of linezolid was c. 6.5 min. The intra- and inter-day reproducibility was good and the assay was linear across the therapeutic range. Serum recovery was c. 100% at all concentrations tested. The detection limit was 0.1 mg/L and the assay was accurate. The assay was specific as there was no significant interference with the linezolid peak. Linezolid was demonstrated to be stable. This rapid assay is ideal for busy clinical laboratories with basic HPLC equipment.</description><identifier>ISSN: 0305-7453</identifier><identifier>ISSN: 1460-2091</identifier><identifier>EISSN: 1460-2091</identifier><identifier>DOI: 10.1093/jac/48.5.605</identifier><identifier>PMID: 11679548</identifier><identifier>CODEN: JACHDX</identifier><language>eng</language><publisher>Oxford: Oxford University Press</publisher><subject>Acetamides - blood ; Analysis ; Anti-Infective Agents - blood ; Biological and medical sciences ; Chromatography, High Pressure Liquid - methods ; Drug Stability ; General pharmacology ; Humans ; Linezolid ; Medical sciences ; Oxazolidinones - blood ; Pharmacology. Drug treatments</subject><ispartof>Journal of antimicrobial chemotherapy, 2001-11, Vol.48 (5), p.605-608</ispartof><rights>2002 INIST-CNRS</rights><rights>Copyright Oxford University Press(England) Nov 2001</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c486t-6359846fa55f56a2ba8f4b981f84c9abb6bed13471d89aed52b64a25eba176623</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=14083315$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/11679548$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tobin, C. M.</creatorcontrib><creatorcontrib>Sunderland, J.</creatorcontrib><creatorcontrib>White, L. O.</creatorcontrib><creatorcontrib>MacGowan, A. P.</creatorcontrib><title>A simple, isocratic high-performance liquid chromatography assay for linezolid in human serum</title><title>Journal of antimicrobial chemotherapy</title><addtitle>J. Antimicrob. Chemother</addtitle><description>A rapid high-performance liquid chromatography (HPLC) assay for the detection of linezolid in human serum was developed. The method used a Hypersil 5ODS stationary phase. The mobile phase was 1% ortho-phosphoric acid, 30% methanol, 2 g/L heptane sulphonic acid, pH 5. UV absorbance detection was used (Ïmax 254 nm). Samples were prepared by mixing with acetonitrile and an injection volume of 20 ÌL was used. The inter- and intra-day assay reproducibility were assessed. Assay linearity, specificity and accuracy were investigated. The detection limit and recovery of linezolid from serum were determined. In addition, the stability of linezolid, stored under a variety of conditions, was assessed. The retention time of linezolid was c. 6.5 min. The intra- and inter-day reproducibility was good and the assay was linear across the therapeutic range. Serum recovery was c. 100% at all concentrations tested. The detection limit was 0.1 mg/L and the assay was accurate. The assay was specific as there was no significant interference with the linezolid peak. Linezolid was demonstrated to be stable. This rapid assay is ideal for busy clinical laboratories with basic HPLC equipment.</description><subject>Acetamides - blood</subject><subject>Analysis</subject><subject>Anti-Infective Agents - blood</subject><subject>Biological and medical sciences</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Drug Stability</subject><subject>General pharmacology</subject><subject>Humans</subject><subject>Linezolid</subject><subject>Medical sciences</subject><subject>Oxazolidinones - blood</subject><subject>Pharmacology. Drug treatments</subject><issn>0305-7453</issn><issn>1460-2091</issn><issn>1460-2091</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2001</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpd0E1r3DAQBmBRGppt2lvPRRTSU7yRrA9LxxCaLwK5JBAKRYxlOdbWthzJhm5_fRV2aSCnOcwzL8OL0BdK1pRodroBe8rVWqwlEe_QinJJipJo-h6tCCOiqLhgh-hjShtCiBRSfUCHlMpKC65W6NcZTn6YeneCfQo2wuwt7vxTV0wutiEOMFqHe_-8-AbbLoYB5vAUYeq2GFKCLc4o70f3N_SZ-BF3Sz7CycVl-IQOWuiT-7yfR-jh4sf9-VVxe3d5fX52W1iu5FxIJrTisgUhWiGhrEG1vNaKtopbDXUta9dQxivaKA2uEWUtOZTC1UArKUt2hL7vcqcYnheXZjP4ZF3fw-jCkkxVloxIpjP89gZuwhLH_Jspc1TFS80zOtkhG0NK0bVmin6AuDWUmJfOTe7ccGWEyZ1n_nWfudSDa17xvuQMjvcAkoW-jblTn14dJ4ox-hJU7JxPs_vzfw_xt5EVq4S5evxp5M2lvniUytyzf_hSmVM</recordid><startdate>20011101</startdate><enddate>20011101</enddate><creator>Tobin, C. M.</creator><creator>Sunderland, J.</creator><creator>White, L. O.</creator><creator>MacGowan, A. P.</creator><general>Oxford University Press</general><general>Oxford Publishing Limited (England)</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QL</scope><scope>7QO</scope><scope>7T7</scope><scope>7U7</scope><scope>7U9</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>H94</scope><scope>K9.</scope><scope>M7N</scope><scope>NAPCQ</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20011101</creationdate><title>A simple, isocratic high-performance liquid chromatography assay for linezolid in human serum</title><author>Tobin, C. M. ; Sunderland, J. ; White, L. O. ; MacGowan, A. P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c486t-6359846fa55f56a2ba8f4b981f84c9abb6bed13471d89aed52b64a25eba176623</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2001</creationdate><topic>Acetamides - blood</topic><topic>Analysis</topic><topic>Anti-Infective Agents - blood</topic><topic>Biological and medical sciences</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Drug Stability</topic><topic>General pharmacology</topic><topic>Humans</topic><topic>Linezolid</topic><topic>Medical sciences</topic><topic>Oxazolidinones - blood</topic><topic>Pharmacology. Drug treatments</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tobin, C. M.</creatorcontrib><creatorcontrib>Sunderland, J.</creatorcontrib><creatorcontrib>White, L. O.</creatorcontrib><creatorcontrib>MacGowan, A. P.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Biotechnology Research Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of antimicrobial chemotherapy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tobin, C. M.</au><au>Sunderland, J.</au><au>White, L. O.</au><au>MacGowan, A. P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A simple, isocratic high-performance liquid chromatography assay for linezolid in human serum</atitle><jtitle>Journal of antimicrobial chemotherapy</jtitle><addtitle>J. Antimicrob. Chemother</addtitle><date>2001-11-01</date><risdate>2001</risdate><volume>48</volume><issue>5</issue><spage>605</spage><epage>608</epage><pages>605-608</pages><issn>0305-7453</issn><issn>1460-2091</issn><eissn>1460-2091</eissn><coden>JACHDX</coden><abstract>A rapid high-performance liquid chromatography (HPLC) assay for the detection of linezolid in human serum was developed. The method used a Hypersil 5ODS stationary phase. The mobile phase was 1% ortho-phosphoric acid, 30% methanol, 2 g/L heptane sulphonic acid, pH 5. UV absorbance detection was used (Ïmax 254 nm). Samples were prepared by mixing with acetonitrile and an injection volume of 20 ÌL was used. The inter- and intra-day assay reproducibility were assessed. Assay linearity, specificity and accuracy were investigated. The detection limit and recovery of linezolid from serum were determined. In addition, the stability of linezolid, stored under a variety of conditions, was assessed. The retention time of linezolid was c. 6.5 min. The intra- and inter-day reproducibility was good and the assay was linear across the therapeutic range. Serum recovery was c. 100% at all concentrations tested. The detection limit was 0.1 mg/L and the assay was accurate. The assay was specific as there was no significant interference with the linezolid peak. Linezolid was demonstrated to be stable. This rapid assay is ideal for busy clinical laboratories with basic HPLC equipment.</abstract><cop>Oxford</cop><pub>Oxford University Press</pub><pmid>11679548</pmid><doi>10.1093/jac/48.5.605</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0305-7453
ispartof Journal of antimicrobial chemotherapy, 2001-11, Vol.48 (5), p.605-608
issn 0305-7453
1460-2091
1460-2091
language eng
recordid cdi_proquest_miscellaneous_72230639
source Oxford University Press Journals All Titles (1996-Current); MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Free Full-Text Journals in Chemistry
subjects Acetamides - blood
Analysis
Anti-Infective Agents - blood
Biological and medical sciences
Chromatography, High Pressure Liquid - methods
Drug Stability
General pharmacology
Humans
Linezolid
Medical sciences
Oxazolidinones - blood
Pharmacology. Drug treatments
title A simple, isocratic high-performance liquid chromatography assay for linezolid in human serum
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T13%3A51%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20simple,%20isocratic%20high-performance%20liquid%20chromatography%20assay%20for%20linezolid%20in%20human%20serum&rft.jtitle=Journal%20of%20antimicrobial%20chemotherapy&rft.au=Tobin,%20C.%20M.&rft.date=2001-11-01&rft.volume=48&rft.issue=5&rft.spage=605&rft.epage=608&rft.pages=605-608&rft.issn=0305-7453&rft.eissn=1460-2091&rft.coden=JACHDX&rft_id=info:doi/10.1093/jac/48.5.605&rft_dat=%3Cproquest_cross%3E373966391%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=217674294&rft_id=info:pmid/11679548&rfr_iscdi=true