Prospective Assessment of Accuracy of Endoanal MR Imaging and Endosonography in Patients with Fecal Incontinence

Endoanal MR imaging was prospectively compared with anal endosonography to determine any superiority in the characterization of sphincter morphology in fecal incontinence. Fifty-two consecutive patients with fecal incontinence were examined with anal endosonography and endoanal MR imaging after a de...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of roentgenology (1976) 2000-09, Vol.175 (3), p.741-745
Hauptverfasser: Malouf, Andrew J, Williams, Andrew B, Halligan, Steve, Bartram, Clive I, Dhillon, Sukvinder, Kamm, Michael A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 745
container_issue 3
container_start_page 741
container_title American journal of roentgenology (1976)
container_volume 175
creator Malouf, Andrew J
Williams, Andrew B
Halligan, Steve
Bartram, Clive I
Dhillon, Sukvinder
Kamm, Michael A
description Endoanal MR imaging was prospectively compared with anal endosonography to determine any superiority in the characterization of sphincter morphology in fecal incontinence. Fifty-two consecutive patients with fecal incontinence were examined with anal endosonography and endoanal MR imaging after a detailed bowel history, clinical examination, and complete anorectal physiologic testing. External and internal anal sphincter integrity was noted on both endosonograms and MR images by two radiologists in consensus, who read individual scans in a random order to avoid recall bias. Imaging findings were subsequently compared, and arbitration of any disagreement between endosonography and MR imaging was made in consensus by a surgeon and a gastroenterologist who also had access to the patient's history, clinical examination, and anorectal physiologic testing results. Complete agreement was found between anal endosonographic and MR imaging interpretations in 32 patients (62%): 10 with combined external and internal sphincter injuries, two with isolated internal sphincter injury, and 20 with intact sphincters. Of 20 patients in whom results of the scans were disparate, incorrect interpretation was found on endosonography in six patients, on MR imaging in 15. Overall, one error relating to the internal sphincter was made on endosonography versus 12 on MR imaging (p = 0.002), and five errors relating to the external sphincter were made on endosonography versus six on MR imaging (p = 1.0). This study suggests that endoanal sonography and endoanal MR imaging are equivalent in diagnosing external anal sphincter injury, but MR imaging is inferior in diagnosing internal anal sphincter injury.
doi_str_mv 10.2214/ajr.175.3.1750741
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72204706</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72204706</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-b1d1152d58cbc76f3b055b464d9023cb8d8ec48e6052abdc99779cf5d27cffa43</originalsourceid><addsrcrecordid>eNpNkEFP2zAYhq2JaXSMH8AF-YC4pbNjO06OFQJWiWkIMYmb5Xx2WqPECXZK1H8_l0YaF9uy3vf5Pj0IXVCyzHPKf-rXsKRSLNnhJJLTL2hBBS8yRjk9QQvCCpqVhL2cou8xvhJCZFnJb-iUkkpwXpAFGh5DHwcLo3u3eBWjjbGzfsR9g1cAu6Bhf3jfetNrr1v8-wmvO71xfoO1Nx__sff9Juhhu8fO40c9ugSIeHLjFt9ZSKW1h96PzlsP9gf62ug22vP5PkN_726fb35lD3_u1zerhwyYkGNWU0OpyI0ooQZZNKwmQtS84KYiOYO6NKUFXtqCiFzXBqpKygoaYXIJTaM5O0PXR-4Q-redjaPqXATbttrbfheVzHPCJSlSkB6DkEzEYBs1BNfpsFeUqINmlTSrJFgxNWtOncsZvqs7az41jl5T4GoO6JgMNEF7cPF_jktefXDmJbdus51csCp2um0Tlappmo5DDwP_AZNYlIU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72204706</pqid></control><display><type>article</type><title>Prospective Assessment of Accuracy of Endoanal MR Imaging and Endosonography in Patients with Fecal Incontinence</title><source>American Roentgen Ray Society</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Malouf, Andrew J ; Williams, Andrew B ; Halligan, Steve ; Bartram, Clive I ; Dhillon, Sukvinder ; Kamm, Michael A</creator><creatorcontrib>Malouf, Andrew J ; Williams, Andrew B ; Halligan, Steve ; Bartram, Clive I ; Dhillon, Sukvinder ; Kamm, Michael A</creatorcontrib><description>Endoanal MR imaging was prospectively compared with anal endosonography to determine any superiority in the characterization of sphincter morphology in fecal incontinence. Fifty-two consecutive patients with fecal incontinence were examined with anal endosonography and endoanal MR imaging after a detailed bowel history, clinical examination, and complete anorectal physiologic testing. External and internal anal sphincter integrity was noted on both endosonograms and MR images by two radiologists in consensus, who read individual scans in a random order to avoid recall bias. Imaging findings were subsequently compared, and arbitration of any disagreement between endosonography and MR imaging was made in consensus by a surgeon and a gastroenterologist who also had access to the patient's history, clinical examination, and anorectal physiologic testing results. Complete agreement was found between anal endosonographic and MR imaging interpretations in 32 patients (62%): 10 with combined external and internal sphincter injuries, two with isolated internal sphincter injury, and 20 with intact sphincters. Of 20 patients in whom results of the scans were disparate, incorrect interpretation was found on endosonography in six patients, on MR imaging in 15. Overall, one error relating to the internal sphincter was made on endosonography versus 12 on MR imaging (p = 0.002), and five errors relating to the external sphincter were made on endosonography versus six on MR imaging (p = 1.0). This study suggests that endoanal sonography and endoanal MR imaging are equivalent in diagnosing external anal sphincter injury, but MR imaging is inferior in diagnosing internal anal sphincter injury.</description><identifier>ISSN: 0361-803X</identifier><identifier>EISSN: 1546-3141</identifier><identifier>DOI: 10.2214/ajr.175.3.1750741</identifier><identifier>PMID: 10954460</identifier><identifier>CODEN: AAJRDX</identifier><language>eng</language><publisher>Leesburg, VA: Am Roentgen Ray Soc</publisher><subject>Adolescent ; Adult ; Aged ; Biological and medical sciences ; Digestive system ; Endosonography ; Fecal Incontinence - diagnostic imaging ; Fecal Incontinence - pathology ; Female ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Magnetic Resonance Imaging ; Male ; Medical sciences ; Middle Aged ; Prospective Studies ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Reproducibility of Results</subject><ispartof>American journal of roentgenology (1976), 2000-09, Vol.175 (3), p.741-745</ispartof><rights>2000 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-b1d1152d58cbc76f3b055b464d9023cb8d8ec48e6052abdc99779cf5d27cffa43</citedby><cites>FETCH-LOGICAL-c357t-b1d1152d58cbc76f3b055b464d9023cb8d8ec48e6052abdc99779cf5d27cffa43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4120,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1474941$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/10954460$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Malouf, Andrew J</creatorcontrib><creatorcontrib>Williams, Andrew B</creatorcontrib><creatorcontrib>Halligan, Steve</creatorcontrib><creatorcontrib>Bartram, Clive I</creatorcontrib><creatorcontrib>Dhillon, Sukvinder</creatorcontrib><creatorcontrib>Kamm, Michael A</creatorcontrib><title>Prospective Assessment of Accuracy of Endoanal MR Imaging and Endosonography in Patients with Fecal Incontinence</title><title>American journal of roentgenology (1976)</title><addtitle>AJR Am J Roentgenol</addtitle><description>Endoanal MR imaging was prospectively compared with anal endosonography to determine any superiority in the characterization of sphincter morphology in fecal incontinence. Fifty-two consecutive patients with fecal incontinence were examined with anal endosonography and endoanal MR imaging after a detailed bowel history, clinical examination, and complete anorectal physiologic testing. External and internal anal sphincter integrity was noted on both endosonograms and MR images by two radiologists in consensus, who read individual scans in a random order to avoid recall bias. Imaging findings were subsequently compared, and arbitration of any disagreement between endosonography and MR imaging was made in consensus by a surgeon and a gastroenterologist who also had access to the patient's history, clinical examination, and anorectal physiologic testing results. Complete agreement was found between anal endosonographic and MR imaging interpretations in 32 patients (62%): 10 with combined external and internal sphincter injuries, two with isolated internal sphincter injury, and 20 with intact sphincters. Of 20 patients in whom results of the scans were disparate, incorrect interpretation was found on endosonography in six patients, on MR imaging in 15. Overall, one error relating to the internal sphincter was made on endosonography versus 12 on MR imaging (p = 0.002), and five errors relating to the external sphincter were made on endosonography versus six on MR imaging (p = 1.0). This study suggests that endoanal sonography and endoanal MR imaging are equivalent in diagnosing external anal sphincter injury, but MR imaging is inferior in diagnosing internal anal sphincter injury.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Digestive system</subject><subject>Endosonography</subject><subject>Fecal Incontinence - diagnostic imaging</subject><subject>Fecal Incontinence - pathology</subject><subject>Female</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Magnetic Resonance Imaging</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Prospective Studies</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Reproducibility of Results</subject><issn>0361-803X</issn><issn>1546-3141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2000</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkEFP2zAYhq2JaXSMH8AF-YC4pbNjO06OFQJWiWkIMYmb5Xx2WqPECXZK1H8_l0YaF9uy3vf5Pj0IXVCyzHPKf-rXsKRSLNnhJJLTL2hBBS8yRjk9QQvCCpqVhL2cou8xvhJCZFnJb-iUkkpwXpAFGh5DHwcLo3u3eBWjjbGzfsR9g1cAu6Bhf3jfetNrr1v8-wmvO71xfoO1Nx__sff9Juhhu8fO40c9ugSIeHLjFt9ZSKW1h96PzlsP9gf62ug22vP5PkN_726fb35lD3_u1zerhwyYkGNWU0OpyI0ooQZZNKwmQtS84KYiOYO6NKUFXtqCiFzXBqpKygoaYXIJTaM5O0PXR-4Q-redjaPqXATbttrbfheVzHPCJSlSkB6DkEzEYBs1BNfpsFeUqINmlTSrJFgxNWtOncsZvqs7az41jl5T4GoO6JgMNEF7cPF_jktefXDmJbdus51csCp2um0Tlappmo5DDwP_AZNYlIU</recordid><startdate>20000901</startdate><enddate>20000901</enddate><creator>Malouf, Andrew J</creator><creator>Williams, Andrew B</creator><creator>Halligan, Steve</creator><creator>Bartram, Clive I</creator><creator>Dhillon, Sukvinder</creator><creator>Kamm, Michael A</creator><general>Am Roentgen Ray Soc</general><general>American Roentgen Ray Society</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20000901</creationdate><title>Prospective Assessment of Accuracy of Endoanal MR Imaging and Endosonography in Patients with Fecal Incontinence</title><author>Malouf, Andrew J ; Williams, Andrew B ; Halligan, Steve ; Bartram, Clive I ; Dhillon, Sukvinder ; Kamm, Michael A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-b1d1152d58cbc76f3b055b464d9023cb8d8ec48e6052abdc99779cf5d27cffa43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2000</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Digestive system</topic><topic>Endosonography</topic><topic>Fecal Incontinence - diagnostic imaging</topic><topic>Fecal Incontinence - pathology</topic><topic>Female</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Magnetic Resonance Imaging</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Prospective Studies</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Reproducibility of Results</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Malouf, Andrew J</creatorcontrib><creatorcontrib>Williams, Andrew B</creatorcontrib><creatorcontrib>Halligan, Steve</creatorcontrib><creatorcontrib>Bartram, Clive I</creatorcontrib><creatorcontrib>Dhillon, Sukvinder</creatorcontrib><creatorcontrib>Kamm, Michael A</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of roentgenology (1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Malouf, Andrew J</au><au>Williams, Andrew B</au><au>Halligan, Steve</au><au>Bartram, Clive I</au><au>Dhillon, Sukvinder</au><au>Kamm, Michael A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Prospective Assessment of Accuracy of Endoanal MR Imaging and Endosonography in Patients with Fecal Incontinence</atitle><jtitle>American journal of roentgenology (1976)</jtitle><addtitle>AJR Am J Roentgenol</addtitle><date>2000-09-01</date><risdate>2000</risdate><volume>175</volume><issue>3</issue><spage>741</spage><epage>745</epage><pages>741-745</pages><issn>0361-803X</issn><eissn>1546-3141</eissn><coden>AAJRDX</coden><abstract>Endoanal MR imaging was prospectively compared with anal endosonography to determine any superiority in the characterization of sphincter morphology in fecal incontinence. Fifty-two consecutive patients with fecal incontinence were examined with anal endosonography and endoanal MR imaging after a detailed bowel history, clinical examination, and complete anorectal physiologic testing. External and internal anal sphincter integrity was noted on both endosonograms and MR images by two radiologists in consensus, who read individual scans in a random order to avoid recall bias. Imaging findings were subsequently compared, and arbitration of any disagreement between endosonography and MR imaging was made in consensus by a surgeon and a gastroenterologist who also had access to the patient's history, clinical examination, and anorectal physiologic testing results. Complete agreement was found between anal endosonographic and MR imaging interpretations in 32 patients (62%): 10 with combined external and internal sphincter injuries, two with isolated internal sphincter injury, and 20 with intact sphincters. Of 20 patients in whom results of the scans were disparate, incorrect interpretation was found on endosonography in six patients, on MR imaging in 15. Overall, one error relating to the internal sphincter was made on endosonography versus 12 on MR imaging (p = 0.002), and five errors relating to the external sphincter were made on endosonography versus six on MR imaging (p = 1.0). This study suggests that endoanal sonography and endoanal MR imaging are equivalent in diagnosing external anal sphincter injury, but MR imaging is inferior in diagnosing internal anal sphincter injury.</abstract><cop>Leesburg, VA</cop><pub>Am Roentgen Ray Soc</pub><pmid>10954460</pmid><doi>10.2214/ajr.175.3.1750741</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0361-803X
ispartof American journal of roentgenology (1976), 2000-09, Vol.175 (3), p.741-745
issn 0361-803X
1546-3141
language eng
recordid cdi_proquest_miscellaneous_72204706
source American Roentgen Ray Society; MEDLINE; Alma/SFX Local Collection
subjects Adolescent
Adult
Aged
Biological and medical sciences
Digestive system
Endosonography
Fecal Incontinence - diagnostic imaging
Fecal Incontinence - pathology
Female
Humans
Investigative techniques, diagnostic techniques (general aspects)
Magnetic Resonance Imaging
Male
Medical sciences
Middle Aged
Prospective Studies
Radiodiagnosis. Nmr imagery. Nmr spectrometry
Reproducibility of Results
title Prospective Assessment of Accuracy of Endoanal MR Imaging and Endosonography in Patients with Fecal Incontinence
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T07%3A55%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Prospective%20Assessment%20of%20Accuracy%20of%20Endoanal%20MR%20Imaging%20and%20Endosonography%20in%20Patients%20with%20Fecal%20Incontinence&rft.jtitle=American%20journal%20of%20roentgenology%20(1976)&rft.au=Malouf,%20Andrew%20J&rft.date=2000-09-01&rft.volume=175&rft.issue=3&rft.spage=741&rft.epage=745&rft.pages=741-745&rft.issn=0361-803X&rft.eissn=1546-3141&rft.coden=AAJRDX&rft_id=info:doi/10.2214/ajr.175.3.1750741&rft_dat=%3Cproquest_cross%3E72204706%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72204706&rft_id=info:pmid/10954460&rfr_iscdi=true