Low-Conductivity Buffers for High-Sensitivity NMR Measurements
The sensitivity of nuclear magnetic resonance (NMR) probes, especially the recently introduced cryogenic probes, can be substantially reduced by the electrical noise generated by conductive samples. In particular, samples of biological macromolecules, which usually contain salts to keep the pH const...
Gespeichert in:
Veröffentlicht in: | Journal of the American Chemical Society 2002-10, Vol.124 (40), p.12013-12019 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 12019 |
---|---|
container_issue | 40 |
container_start_page | 12013 |
container_title | Journal of the American Chemical Society |
container_volume | 124 |
creator | Kelly, Alexander E Ou, Horng D Withers, Richard Dötsch, Volker |
description | The sensitivity of nuclear magnetic resonance (NMR) probes, especially the recently introduced cryogenic probes, can be substantially reduced by the electrical noise generated by conductive samples. In particular, samples of biological macromolecules, which usually contain salts to keep the pH constant and to prevent aggregation, can experience a significant reduction in sensitivity. So far this dependence has forced researchers to minimize the salt concentrations in their samples. Here we demonstrate that the decisive factor is not the salt concentration itself but the conductivity which is a function of both the concentration and the mobility of the ions in solution. We show that by choosing buffers with low ionic mobility, the sample conductivity can be dramatically reduced and the sensitivity substantially enhanced compared to the same measurement with an equal concentration of a standard NMR buffer such as phosphate. We further show that the highest sensitivity gain of one buffer over another buffer is equal to the square root of the ratio of their ion mobilities and describe a simple method to evaluate the effect of a certain buffer on the sensitivity. |
doi_str_mv | 10.1021/ja026121b |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72143105</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>72143105</sourcerecordid><originalsourceid>FETCH-LOGICAL-a415t-6afa25135916c08db8a94cf99a06fe23a522923da59cc836875e684c6ef4af763</originalsourceid><addsrcrecordid>eNpt0E9LwzAYBvAgipvTg19AelHwEM2fJk0vgivqlE3FTa8hSxPtXNuZtOq-vZWWefH08vL-eF54ADjE6Awjgs8XChGOCZ5vgT5mBEGGCd8GfYQQgZHgtAf2vF80a0gE3gU9TCgTLBR9cDEuv2BSFmmtq-wzq9bBsLbWOB_Y0gWj7PUNTk3hs-54P3kKJkb52pncFJXfBztWLb056OYAPF9fzZIRHD_c3CaXY6hCzCrIlVWEYcpizDUS6VyoONQ2jhXi1hCqGCExoalisdaCchExw0WoubGhshGnA3DS5q5c-VEbX8k889osl6owZe1lRHBIMWINPG2hdqX3zli5clmu3FpiJH_LkpuyGnvUhdbz3KR_smunAbAFma_M9-au3LvkEY2YnD1O5USgO5oMXyRt_HHrlfZyUdauaDr55_EPXc9-Pg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72143105</pqid></control><display><type>article</type><title>Low-Conductivity Buffers for High-Sensitivity NMR Measurements</title><source>MEDLINE</source><source>American Chemical Society Journals</source><creator>Kelly, Alexander E ; Ou, Horng D ; Withers, Richard ; Dötsch, Volker</creator><creatorcontrib>Kelly, Alexander E ; Ou, Horng D ; Withers, Richard ; Dötsch, Volker</creatorcontrib><description>The sensitivity of nuclear magnetic resonance (NMR) probes, especially the recently introduced cryogenic probes, can be substantially reduced by the electrical noise generated by conductive samples. In particular, samples of biological macromolecules, which usually contain salts to keep the pH constant and to prevent aggregation, can experience a significant reduction in sensitivity. So far this dependence has forced researchers to minimize the salt concentrations in their samples. Here we demonstrate that the decisive factor is not the salt concentration itself but the conductivity which is a function of both the concentration and the mobility of the ions in solution. We show that by choosing buffers with low ionic mobility, the sample conductivity can be dramatically reduced and the sensitivity substantially enhanced compared to the same measurement with an equal concentration of a standard NMR buffer such as phosphate. We further show that the highest sensitivity gain of one buffer over another buffer is equal to the square root of the ratio of their ion mobilities and describe a simple method to evaluate the effect of a certain buffer on the sensitivity.</description><identifier>ISSN: 0002-7863</identifier><identifier>EISSN: 1520-5126</identifier><identifier>DOI: 10.1021/ja026121b</identifier><identifier>PMID: 12358548</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Buffers ; Electric Conductivity ; Hydrogen-Ion Concentration ; Magnetic Resonance Spectroscopy - methods ; Sensitivity and Specificity</subject><ispartof>Journal of the American Chemical Society, 2002-10, Vol.124 (40), p.12013-12019</ispartof><rights>Copyright © 2002 American Chemical Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a415t-6afa25135916c08db8a94cf99a06fe23a522923da59cc836875e684c6ef4af763</citedby><cites>FETCH-LOGICAL-a415t-6afa25135916c08db8a94cf99a06fe23a522923da59cc836875e684c6ef4af763</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/ja026121b$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/ja026121b$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2765,27076,27924,27925,56738,56788</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12358548$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kelly, Alexander E</creatorcontrib><creatorcontrib>Ou, Horng D</creatorcontrib><creatorcontrib>Withers, Richard</creatorcontrib><creatorcontrib>Dötsch, Volker</creatorcontrib><title>Low-Conductivity Buffers for High-Sensitivity NMR Measurements</title><title>Journal of the American Chemical Society</title><addtitle>J. Am. Chem. Soc</addtitle><description>The sensitivity of nuclear magnetic resonance (NMR) probes, especially the recently introduced cryogenic probes, can be substantially reduced by the electrical noise generated by conductive samples. In particular, samples of biological macromolecules, which usually contain salts to keep the pH constant and to prevent aggregation, can experience a significant reduction in sensitivity. So far this dependence has forced researchers to minimize the salt concentrations in their samples. Here we demonstrate that the decisive factor is not the salt concentration itself but the conductivity which is a function of both the concentration and the mobility of the ions in solution. We show that by choosing buffers with low ionic mobility, the sample conductivity can be dramatically reduced and the sensitivity substantially enhanced compared to the same measurement with an equal concentration of a standard NMR buffer such as phosphate. We further show that the highest sensitivity gain of one buffer over another buffer is equal to the square root of the ratio of their ion mobilities and describe a simple method to evaluate the effect of a certain buffer on the sensitivity.</description><subject>Buffers</subject><subject>Electric Conductivity</subject><subject>Hydrogen-Ion Concentration</subject><subject>Magnetic Resonance Spectroscopy - methods</subject><subject>Sensitivity and Specificity</subject><issn>0002-7863</issn><issn>1520-5126</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpt0E9LwzAYBvAgipvTg19AelHwEM2fJk0vgivqlE3FTa8hSxPtXNuZtOq-vZWWefH08vL-eF54ADjE6Awjgs8XChGOCZ5vgT5mBEGGCd8GfYQQgZHgtAf2vF80a0gE3gU9TCgTLBR9cDEuv2BSFmmtq-wzq9bBsLbWOB_Y0gWj7PUNTk3hs-54P3kKJkb52pncFJXfBztWLb056OYAPF9fzZIRHD_c3CaXY6hCzCrIlVWEYcpizDUS6VyoONQ2jhXi1hCqGCExoalisdaCchExw0WoubGhshGnA3DS5q5c-VEbX8k889osl6owZe1lRHBIMWINPG2hdqX3zli5clmu3FpiJH_LkpuyGnvUhdbz3KR_smunAbAFma_M9-au3LvkEY2YnD1O5USgO5oMXyRt_HHrlfZyUdauaDr55_EPXc9-Pg</recordid><startdate>20021009</startdate><enddate>20021009</enddate><creator>Kelly, Alexander E</creator><creator>Ou, Horng D</creator><creator>Withers, Richard</creator><creator>Dötsch, Volker</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20021009</creationdate><title>Low-Conductivity Buffers for High-Sensitivity NMR Measurements</title><author>Kelly, Alexander E ; Ou, Horng D ; Withers, Richard ; Dötsch, Volker</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a415t-6afa25135916c08db8a94cf99a06fe23a522923da59cc836875e684c6ef4af763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Buffers</topic><topic>Electric Conductivity</topic><topic>Hydrogen-Ion Concentration</topic><topic>Magnetic Resonance Spectroscopy - methods</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kelly, Alexander E</creatorcontrib><creatorcontrib>Ou, Horng D</creatorcontrib><creatorcontrib>Withers, Richard</creatorcontrib><creatorcontrib>Dötsch, Volker</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American Chemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kelly, Alexander E</au><au>Ou, Horng D</au><au>Withers, Richard</au><au>Dötsch, Volker</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Low-Conductivity Buffers for High-Sensitivity NMR Measurements</atitle><jtitle>Journal of the American Chemical Society</jtitle><addtitle>J. Am. Chem. Soc</addtitle><date>2002-10-09</date><risdate>2002</risdate><volume>124</volume><issue>40</issue><spage>12013</spage><epage>12019</epage><pages>12013-12019</pages><issn>0002-7863</issn><eissn>1520-5126</eissn><abstract>The sensitivity of nuclear magnetic resonance (NMR) probes, especially the recently introduced cryogenic probes, can be substantially reduced by the electrical noise generated by conductive samples. In particular, samples of biological macromolecules, which usually contain salts to keep the pH constant and to prevent aggregation, can experience a significant reduction in sensitivity. So far this dependence has forced researchers to minimize the salt concentrations in their samples. Here we demonstrate that the decisive factor is not the salt concentration itself but the conductivity which is a function of both the concentration and the mobility of the ions in solution. We show that by choosing buffers with low ionic mobility, the sample conductivity can be dramatically reduced and the sensitivity substantially enhanced compared to the same measurement with an equal concentration of a standard NMR buffer such as phosphate. We further show that the highest sensitivity gain of one buffer over another buffer is equal to the square root of the ratio of their ion mobilities and describe a simple method to evaluate the effect of a certain buffer on the sensitivity.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>12358548</pmid><doi>10.1021/ja026121b</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0002-7863 |
ispartof | Journal of the American Chemical Society, 2002-10, Vol.124 (40), p.12013-12019 |
issn | 0002-7863 1520-5126 |
language | eng |
recordid | cdi_proquest_miscellaneous_72143105 |
source | MEDLINE; American Chemical Society Journals |
subjects | Buffers Electric Conductivity Hydrogen-Ion Concentration Magnetic Resonance Spectroscopy - methods Sensitivity and Specificity |
title | Low-Conductivity Buffers for High-Sensitivity NMR Measurements |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T23%3A45%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Low-Conductivity%20Buffers%20for%20High-Sensitivity%20NMR%20Measurements&rft.jtitle=Journal%20of%20the%20American%20Chemical%20Society&rft.au=Kelly,%20Alexander%20E&rft.date=2002-10-09&rft.volume=124&rft.issue=40&rft.spage=12013&rft.epage=12019&rft.pages=12013-12019&rft.issn=0002-7863&rft.eissn=1520-5126&rft_id=info:doi/10.1021/ja026121b&rft_dat=%3Cproquest_cross%3E72143105%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72143105&rft_id=info:pmid/12358548&rfr_iscdi=true |