Reproducibility of twitch and sniff transdiaphragmatic pressures

Twitch transdiaphragmatic pressure (Tw Pdi) measured with magnetic stimulation of the phrenic nerve is used to follow up patients and to assess the effect of clinical treatments on diaphragm function. However the reproducibility of Tw Pdi on different occasions has been little studied. We investigat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Respiratory physiology & neurobiology 2002-09, Vol.132 (3), p.301-306
Hauptverfasser: Luo, Y.M, Hart, N, Mustfa, N, Man, W.D.C, Rafferty, G.F, Polkey, M.I, Moxham, J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 306
container_issue 3
container_start_page 301
container_title Respiratory physiology & neurobiology
container_volume 132
creator Luo, Y.M
Hart, N
Mustfa, N
Man, W.D.C
Rafferty, G.F
Polkey, M.I
Moxham, J
description Twitch transdiaphragmatic pressure (Tw Pdi) measured with magnetic stimulation of the phrenic nerve is used to follow up patients and to assess the effect of clinical treatments on diaphragm function. However the reproducibility of Tw Pdi on different occasions has been little studied. We investigated 32 normal subjects, measuring Tw Pdi elicited by bilateral magnetic stimulation of the phrenic nerves on two to 14 occasions. Sniff transdiaphragmatic pressure (sniff Pdi) was also measured. The mean value of Tw Pdi and sniff Pdi were 28±5 and 134±24 cm H 2O, respectively. The within subjects coefficient of variation was 11% for both Tw Pdi and sniff Pdi. We conclude that there is a variability of Tw Pdi and the variability of Tw Pdi is the same as that of sniff Pdi.
doi_str_mv 10.1016/S1569-9048(02)00115-5
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72057795</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1569904802001155</els_id><sourcerecordid>72057795</sourcerecordid><originalsourceid>FETCH-LOGICAL-c391t-8f5431a1e4d24ba974a6e42caa626dc1581ea19df4795bf37472a15e12a223e73</originalsourceid><addsrcrecordid>eNqFkE1P3DAQhi1UxFf7E0C5tGoPoR47juMTVCsKSEhItD1bs_YEjLLJYicg_n29H4gjl_HIel771cPYMfBT4FD__AOqNqXhVfOdix-cA6hS7bADaHRTggLzKe9vyD47TOkxQxq03GP7IARveNMcsPM7WsbBTy7MQxfG12Joi_EljO6hwN4XqQ9tvojYJx9w-RDxfoFjcMUyUkpTHp_Zbotdoi_b84j9-33xd3ZV3txeXs9-3ZROGhjLplWVBASqvKjmaHSFNVXCIdai9g5UA4RgfFtpo-at1JUWCIpAoBCStDxi3zbv5rpPE6XRLkJy1HXY0zAlqwVXOmczqDagi0NKkVq7jGGB8dUCtyt1dq3OrrxYLuxanV3lTrYfTPMF-ffU1lUGvm4BTA67NktxIb1z0nAjZZ25sw1HWcdzoGiTC9Q78iGSG60fwgdV_gP_L4rp</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72057795</pqid></control><display><type>article</type><title>Reproducibility of twitch and sniff transdiaphragmatic pressures</title><source>Elsevier ScienceDirect Journals Complete - AutoHoldings</source><source>MEDLINE</source><creator>Luo, Y.M ; Hart, N ; Mustfa, N ; Man, W.D.C ; Rafferty, G.F ; Polkey, M.I ; Moxham, J</creator><creatorcontrib>Luo, Y.M ; Hart, N ; Mustfa, N ; Man, W.D.C ; Rafferty, G.F ; Polkey, M.I ; Moxham, J</creatorcontrib><description>Twitch transdiaphragmatic pressure (Tw Pdi) measured with magnetic stimulation of the phrenic nerve is used to follow up patients and to assess the effect of clinical treatments on diaphragm function. However the reproducibility of Tw Pdi on different occasions has been little studied. We investigated 32 normal subjects, measuring Tw Pdi elicited by bilateral magnetic stimulation of the phrenic nerves on two to 14 occasions. Sniff transdiaphragmatic pressure (sniff Pdi) was also measured. The mean value of Tw Pdi and sniff Pdi were 28±5 and 134±24 cm H 2O, respectively. The within subjects coefficient of variation was 11% for both Tw Pdi and sniff Pdi. We conclude that there is a variability of Tw Pdi and the variability of Tw Pdi is the same as that of sniff Pdi.</description><identifier>ISSN: 1569-9048</identifier><identifier>EISSN: 1878-1519</identifier><identifier>DOI: 10.1016/S1569-9048(02)00115-5</identifier><identifier>PMID: 12208088</identifier><language>eng</language><publisher>Amsterdarm: Elsevier B.V</publisher><subject>Biological and medical sciences ; Birth control ; Diaphragm - innervation ; Diaphragm - physiology ; Electric Stimulation - methods ; Electromagnetic Phenomena ; Gynecology. Andrology. Obstetrics ; Humans ; Inspiratory Capacity ; Mammals, Humans ; Medical sciences ; Methods, magnetic stimulation, diaphragm ; Muscle Contraction - physiology ; Muscle, diaphragm, magnetic stimulation ; Nerve, phrenic ; Other methods of contraception. Sterilization ; Phrenic Nerve - physiology ; Pressure ; Pressure, twitch, transdiaphragmatic ; Reproducibility of Results ; Respiration ; Sensitivity and Specificity</subject><ispartof>Respiratory physiology &amp; neurobiology, 2002-09, Vol.132 (3), p.301-306</ispartof><rights>2002 Elsevier Science B.V.</rights><rights>2002 INIST-CNRS</rights><rights>Copyright 2002 Elsevier Science B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c391t-8f5431a1e4d24ba974a6e42caa626dc1581ea19df4795bf37472a15e12a223e73</citedby><cites>FETCH-LOGICAL-c391t-8f5431a1e4d24ba974a6e42caa626dc1581ea19df4795bf37472a15e12a223e73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/S1569-9048(02)00115-5$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,778,782,3539,27913,27914,45984</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13909336$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12208088$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Luo, Y.M</creatorcontrib><creatorcontrib>Hart, N</creatorcontrib><creatorcontrib>Mustfa, N</creatorcontrib><creatorcontrib>Man, W.D.C</creatorcontrib><creatorcontrib>Rafferty, G.F</creatorcontrib><creatorcontrib>Polkey, M.I</creatorcontrib><creatorcontrib>Moxham, J</creatorcontrib><title>Reproducibility of twitch and sniff transdiaphragmatic pressures</title><title>Respiratory physiology &amp; neurobiology</title><addtitle>Respir Physiol Neurobiol</addtitle><description>Twitch transdiaphragmatic pressure (Tw Pdi) measured with magnetic stimulation of the phrenic nerve is used to follow up patients and to assess the effect of clinical treatments on diaphragm function. However the reproducibility of Tw Pdi on different occasions has been little studied. We investigated 32 normal subjects, measuring Tw Pdi elicited by bilateral magnetic stimulation of the phrenic nerves on two to 14 occasions. Sniff transdiaphragmatic pressure (sniff Pdi) was also measured. The mean value of Tw Pdi and sniff Pdi were 28±5 and 134±24 cm H 2O, respectively. The within subjects coefficient of variation was 11% for both Tw Pdi and sniff Pdi. We conclude that there is a variability of Tw Pdi and the variability of Tw Pdi is the same as that of sniff Pdi.</description><subject>Biological and medical sciences</subject><subject>Birth control</subject><subject>Diaphragm - innervation</subject><subject>Diaphragm - physiology</subject><subject>Electric Stimulation - methods</subject><subject>Electromagnetic Phenomena</subject><subject>Gynecology. Andrology. Obstetrics</subject><subject>Humans</subject><subject>Inspiratory Capacity</subject><subject>Mammals, Humans</subject><subject>Medical sciences</subject><subject>Methods, magnetic stimulation, diaphragm</subject><subject>Muscle Contraction - physiology</subject><subject>Muscle, diaphragm, magnetic stimulation</subject><subject>Nerve, phrenic</subject><subject>Other methods of contraception. Sterilization</subject><subject>Phrenic Nerve - physiology</subject><subject>Pressure</subject><subject>Pressure, twitch, transdiaphragmatic</subject><subject>Reproducibility of Results</subject><subject>Respiration</subject><subject>Sensitivity and Specificity</subject><issn>1569-9048</issn><issn>1878-1519</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1P3DAQhi1UxFf7E0C5tGoPoR47juMTVCsKSEhItD1bs_YEjLLJYicg_n29H4gjl_HIel771cPYMfBT4FD__AOqNqXhVfOdix-cA6hS7bADaHRTggLzKe9vyD47TOkxQxq03GP7IARveNMcsPM7WsbBTy7MQxfG12Joi_EljO6hwN4XqQ9tvojYJx9w-RDxfoFjcMUyUkpTHp_Zbotdoi_b84j9-33xd3ZV3txeXs9-3ZROGhjLplWVBASqvKjmaHSFNVXCIdai9g5UA4RgfFtpo-at1JUWCIpAoBCStDxi3zbv5rpPE6XRLkJy1HXY0zAlqwVXOmczqDagi0NKkVq7jGGB8dUCtyt1dq3OrrxYLuxanV3lTrYfTPMF-ffU1lUGvm4BTA67NktxIb1z0nAjZZ25sw1HWcdzoGiTC9Q78iGSG60fwgdV_gP_L4rp</recordid><startdate>20020904</startdate><enddate>20020904</enddate><creator>Luo, Y.M</creator><creator>Hart, N</creator><creator>Mustfa, N</creator><creator>Man, W.D.C</creator><creator>Rafferty, G.F</creator><creator>Polkey, M.I</creator><creator>Moxham, J</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20020904</creationdate><title>Reproducibility of twitch and sniff transdiaphragmatic pressures</title><author>Luo, Y.M ; Hart, N ; Mustfa, N ; Man, W.D.C ; Rafferty, G.F ; Polkey, M.I ; Moxham, J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c391t-8f5431a1e4d24ba974a6e42caa626dc1581ea19df4795bf37472a15e12a223e73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Biological and medical sciences</topic><topic>Birth control</topic><topic>Diaphragm - innervation</topic><topic>Diaphragm - physiology</topic><topic>Electric Stimulation - methods</topic><topic>Electromagnetic Phenomena</topic><topic>Gynecology. Andrology. Obstetrics</topic><topic>Humans</topic><topic>Inspiratory Capacity</topic><topic>Mammals, Humans</topic><topic>Medical sciences</topic><topic>Methods, magnetic stimulation, diaphragm</topic><topic>Muscle Contraction - physiology</topic><topic>Muscle, diaphragm, magnetic stimulation</topic><topic>Nerve, phrenic</topic><topic>Other methods of contraception. Sterilization</topic><topic>Phrenic Nerve - physiology</topic><topic>Pressure</topic><topic>Pressure, twitch, transdiaphragmatic</topic><topic>Reproducibility of Results</topic><topic>Respiration</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Luo, Y.M</creatorcontrib><creatorcontrib>Hart, N</creatorcontrib><creatorcontrib>Mustfa, N</creatorcontrib><creatorcontrib>Man, W.D.C</creatorcontrib><creatorcontrib>Rafferty, G.F</creatorcontrib><creatorcontrib>Polkey, M.I</creatorcontrib><creatorcontrib>Moxham, J</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Respiratory physiology &amp; neurobiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Luo, Y.M</au><au>Hart, N</au><au>Mustfa, N</au><au>Man, W.D.C</au><au>Rafferty, G.F</au><au>Polkey, M.I</au><au>Moxham, J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reproducibility of twitch and sniff transdiaphragmatic pressures</atitle><jtitle>Respiratory physiology &amp; neurobiology</jtitle><addtitle>Respir Physiol Neurobiol</addtitle><date>2002-09-04</date><risdate>2002</risdate><volume>132</volume><issue>3</issue><spage>301</spage><epage>306</epage><pages>301-306</pages><issn>1569-9048</issn><eissn>1878-1519</eissn><abstract>Twitch transdiaphragmatic pressure (Tw Pdi) measured with magnetic stimulation of the phrenic nerve is used to follow up patients and to assess the effect of clinical treatments on diaphragm function. However the reproducibility of Tw Pdi on different occasions has been little studied. We investigated 32 normal subjects, measuring Tw Pdi elicited by bilateral magnetic stimulation of the phrenic nerves on two to 14 occasions. Sniff transdiaphragmatic pressure (sniff Pdi) was also measured. The mean value of Tw Pdi and sniff Pdi were 28±5 and 134±24 cm H 2O, respectively. The within subjects coefficient of variation was 11% for both Tw Pdi and sniff Pdi. We conclude that there is a variability of Tw Pdi and the variability of Tw Pdi is the same as that of sniff Pdi.</abstract><cop>Amsterdarm</cop><pub>Elsevier B.V</pub><pmid>12208088</pmid><doi>10.1016/S1569-9048(02)00115-5</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1569-9048
ispartof Respiratory physiology & neurobiology, 2002-09, Vol.132 (3), p.301-306
issn 1569-9048
1878-1519
language eng
recordid cdi_proquest_miscellaneous_72057795
source Elsevier ScienceDirect Journals Complete - AutoHoldings; MEDLINE
subjects Biological and medical sciences
Birth control
Diaphragm - innervation
Diaphragm - physiology
Electric Stimulation - methods
Electromagnetic Phenomena
Gynecology. Andrology. Obstetrics
Humans
Inspiratory Capacity
Mammals, Humans
Medical sciences
Methods, magnetic stimulation, diaphragm
Muscle Contraction - physiology
Muscle, diaphragm, magnetic stimulation
Nerve, phrenic
Other methods of contraception. Sterilization
Phrenic Nerve - physiology
Pressure
Pressure, twitch, transdiaphragmatic
Reproducibility of Results
Respiration
Sensitivity and Specificity
title Reproducibility of twitch and sniff transdiaphragmatic pressures
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T07%3A55%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reproducibility%20of%20twitch%20and%20sniff%20transdiaphragmatic%20pressures&rft.jtitle=Respiratory%20physiology%20&%20neurobiology&rft.au=Luo,%20Y.M&rft.date=2002-09-04&rft.volume=132&rft.issue=3&rft.spage=301&rft.epage=306&rft.pages=301-306&rft.issn=1569-9048&rft.eissn=1878-1519&rft_id=info:doi/10.1016/S1569-9048(02)00115-5&rft_dat=%3Cproquest_cross%3E72057795%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72057795&rft_id=info:pmid/12208088&rft_els_id=S1569904802001155&rfr_iscdi=true