Ruptured Tibio-fibular Syndesmosis: Comparison Study of Metallic to Bioabsorbable Fixation

The patients of this study come from a series of 43 consecutive ankle fracture patients with syndesmotic rupture operated on at our department. Of these patients, 18 were treated with bioabsorbable self-reinforced poly-L-lactide screw and 12 treated with metallic screw. All agreed to participate in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Foot & ankle international 2002-08, Vol.23 (8), p.744-748
Hauptverfasser: Sinisaari, Ilkka P., Lüthje, Peter M.J., Mikkonen, Raija H.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 748
container_issue 8
container_start_page 744
container_title Foot & ankle international
container_volume 23
creator Sinisaari, Ilkka P.
Lüthje, Peter M.J.
Mikkonen, Raija H.M.
description The patients of this study come from a series of 43 consecutive ankle fracture patients with syndesmotic rupture operated on at our department. Of these patients, 18 were treated with bioabsorbable self-reinforced poly-L-lactide screw and 12 treated with metallic screw. All agreed to participate in this study. They were examined after a minimum follow-up period of 12 months. The patients were examined for measurements from ankle radiographic and computed tomography films, loaded dorsal range of movement of the ankle, and duration of sick leave. Subjective results were obtained by a constructed questionnaire. There were no significant differences between the patient groups in any of the parameters measured. We conclude that the fixation of a syndesmotic rupture can be done with a bioabsorbable self-reinforced poly-L-lactide screw.
doi_str_mv 10.1177/107110070202300811
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_72036217</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_107110070202300811</sage_id><sourcerecordid>72036217</sourcerecordid><originalsourceid>FETCH-LOGICAL-c339t-699337ac57ddaad69d2da891d3c45a482aafac7e50583a2904b9c16d934d33713</originalsourceid><addsrcrecordid>eNp9kDFPwzAUhC0EoqXwBxiQJ7ZQPzuJYzaoKCAVIdGysEQvsYNcJXGxE4n-e1K1EgMS07vhu9O7I-QS2A2AlFNgEoAxyTjjgrEM4IiMQcVxJDOZHg96AKIdMSJnIawZAylAnZIRcFBKZGpMPt76Tdd7o-nKFtZFlS36Gj1dblttQuOCDbd05poNehtcS5ddr7fUVfTFdFjXtqSdo_fWYRGcL7CoDZ3bb-ysa8_JSYV1MBeHOyHv84fV7ClavD4-z-4WUSmE6qJ0-ERILBOpNaJOleYaMwValHGCccYRKyylSViSCeSKxYUqIdVKxHowgpiQ633uxruv3oQub2woTV1ja1wfcsmZSPlQfUL4Hiy9C8GbKt9426Df5sDy3aL530UH09UhvS8ao38thwkHYLoHAn6afO163w5t_4v8Aad8fl8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>72036217</pqid></control><display><type>article</type><title>Ruptured Tibio-fibular Syndesmosis: Comparison Study of Metallic to Bioabsorbable Fixation</title><source>Access via SAGE</source><source>MEDLINE</source><creator>Sinisaari, Ilkka P. ; Lüthje, Peter M.J. ; Mikkonen, Raija H.M.</creator><creatorcontrib>Sinisaari, Ilkka P. ; Lüthje, Peter M.J. ; Mikkonen, Raija H.M.</creatorcontrib><description>The patients of this study come from a series of 43 consecutive ankle fracture patients with syndesmotic rupture operated on at our department. Of these patients, 18 were treated with bioabsorbable self-reinforced poly-L-lactide screw and 12 treated with metallic screw. All agreed to participate in this study. They were examined after a minimum follow-up period of 12 months. The patients were examined for measurements from ankle radiographic and computed tomography films, loaded dorsal range of movement of the ankle, and duration of sick leave. Subjective results were obtained by a constructed questionnaire. There were no significant differences between the patient groups in any of the parameters measured. We conclude that the fixation of a syndesmotic rupture can be done with a bioabsorbable self-reinforced poly-L-lactide screw.</description><identifier>ISSN: 1071-1007</identifier><identifier>EISSN: 1944-7876</identifier><identifier>DOI: 10.1177/107110070202300811</identifier><identifier>PMID: 12199389</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Absorbable Implants ; Ankle Injuries - complications ; Ankle Injuries - surgery ; Biocompatible Materials ; Bone Screws ; Fracture Fixation, Internal - instrumentation ; Fractures, Bone - complications ; Fractures, Bone - surgery ; Humans ; Metals ; Polyesters ; Rupture</subject><ispartof>Foot &amp; ankle international, 2002-08, Vol.23 (8), p.744-748</ispartof><rights>2002 American Orthopaedic Foot &amp; Ankle Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c339t-699337ac57ddaad69d2da891d3c45a482aafac7e50583a2904b9c16d934d33713</citedby><cites>FETCH-LOGICAL-c339t-699337ac57ddaad69d2da891d3c45a482aafac7e50583a2904b9c16d934d33713</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/107110070202300811$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/107110070202300811$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>314,780,784,21819,27924,27925,43621,43622</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12199389$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sinisaari, Ilkka P.</creatorcontrib><creatorcontrib>Lüthje, Peter M.J.</creatorcontrib><creatorcontrib>Mikkonen, Raija H.M.</creatorcontrib><title>Ruptured Tibio-fibular Syndesmosis: Comparison Study of Metallic to Bioabsorbable Fixation</title><title>Foot &amp; ankle international</title><addtitle>Foot Ankle Int</addtitle><description>The patients of this study come from a series of 43 consecutive ankle fracture patients with syndesmotic rupture operated on at our department. Of these patients, 18 were treated with bioabsorbable self-reinforced poly-L-lactide screw and 12 treated with metallic screw. All agreed to participate in this study. They were examined after a minimum follow-up period of 12 months. The patients were examined for measurements from ankle radiographic and computed tomography films, loaded dorsal range of movement of the ankle, and duration of sick leave. Subjective results were obtained by a constructed questionnaire. There were no significant differences between the patient groups in any of the parameters measured. We conclude that the fixation of a syndesmotic rupture can be done with a bioabsorbable self-reinforced poly-L-lactide screw.</description><subject>Absorbable Implants</subject><subject>Ankle Injuries - complications</subject><subject>Ankle Injuries - surgery</subject><subject>Biocompatible Materials</subject><subject>Bone Screws</subject><subject>Fracture Fixation, Internal - instrumentation</subject><subject>Fractures, Bone - complications</subject><subject>Fractures, Bone - surgery</subject><subject>Humans</subject><subject>Metals</subject><subject>Polyesters</subject><subject>Rupture</subject><issn>1071-1007</issn><issn>1944-7876</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kDFPwzAUhC0EoqXwBxiQJ7ZQPzuJYzaoKCAVIdGysEQvsYNcJXGxE4n-e1K1EgMS07vhu9O7I-QS2A2AlFNgEoAxyTjjgrEM4IiMQcVxJDOZHg96AKIdMSJnIawZAylAnZIRcFBKZGpMPt76Tdd7o-nKFtZFlS36Gj1dblttQuOCDbd05poNehtcS5ddr7fUVfTFdFjXtqSdo_fWYRGcL7CoDZ3bb-ysa8_JSYV1MBeHOyHv84fV7ClavD4-z-4WUSmE6qJ0-ERILBOpNaJOleYaMwValHGCccYRKyylSViSCeSKxYUqIdVKxHowgpiQ633uxruv3oQub2woTV1ja1wfcsmZSPlQfUL4Hiy9C8GbKt9426Df5sDy3aL530UH09UhvS8ao38thwkHYLoHAn6afO163w5t_4v8Aad8fl8</recordid><startdate>20020801</startdate><enddate>20020801</enddate><creator>Sinisaari, Ilkka P.</creator><creator>Lüthje, Peter M.J.</creator><creator>Mikkonen, Raija H.M.</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20020801</creationdate><title>Ruptured Tibio-fibular Syndesmosis: Comparison Study of Metallic to Bioabsorbable Fixation</title><author>Sinisaari, Ilkka P. ; Lüthje, Peter M.J. ; Mikkonen, Raija H.M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c339t-699337ac57ddaad69d2da891d3c45a482aafac7e50583a2904b9c16d934d33713</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Absorbable Implants</topic><topic>Ankle Injuries - complications</topic><topic>Ankle Injuries - surgery</topic><topic>Biocompatible Materials</topic><topic>Bone Screws</topic><topic>Fracture Fixation, Internal - instrumentation</topic><topic>Fractures, Bone - complications</topic><topic>Fractures, Bone - surgery</topic><topic>Humans</topic><topic>Metals</topic><topic>Polyesters</topic><topic>Rupture</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sinisaari, Ilkka P.</creatorcontrib><creatorcontrib>Lüthje, Peter M.J.</creatorcontrib><creatorcontrib>Mikkonen, Raija H.M.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Foot &amp; ankle international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sinisaari, Ilkka P.</au><au>Lüthje, Peter M.J.</au><au>Mikkonen, Raija H.M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ruptured Tibio-fibular Syndesmosis: Comparison Study of Metallic to Bioabsorbable Fixation</atitle><jtitle>Foot &amp; ankle international</jtitle><addtitle>Foot Ankle Int</addtitle><date>2002-08-01</date><risdate>2002</risdate><volume>23</volume><issue>8</issue><spage>744</spage><epage>748</epage><pages>744-748</pages><issn>1071-1007</issn><eissn>1944-7876</eissn><abstract>The patients of this study come from a series of 43 consecutive ankle fracture patients with syndesmotic rupture operated on at our department. Of these patients, 18 were treated with bioabsorbable self-reinforced poly-L-lactide screw and 12 treated with metallic screw. All agreed to participate in this study. They were examined after a minimum follow-up period of 12 months. The patients were examined for measurements from ankle radiographic and computed tomography films, loaded dorsal range of movement of the ankle, and duration of sick leave. Subjective results were obtained by a constructed questionnaire. There were no significant differences between the patient groups in any of the parameters measured. We conclude that the fixation of a syndesmotic rupture can be done with a bioabsorbable self-reinforced poly-L-lactide screw.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>12199389</pmid><doi>10.1177/107110070202300811</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1071-1007
ispartof Foot & ankle international, 2002-08, Vol.23 (8), p.744-748
issn 1071-1007
1944-7876
language eng
recordid cdi_proquest_miscellaneous_72036217
source Access via SAGE; MEDLINE
subjects Absorbable Implants
Ankle Injuries - complications
Ankle Injuries - surgery
Biocompatible Materials
Bone Screws
Fracture Fixation, Internal - instrumentation
Fractures, Bone - complications
Fractures, Bone - surgery
Humans
Metals
Polyesters
Rupture
title Ruptured Tibio-fibular Syndesmosis: Comparison Study of Metallic to Bioabsorbable Fixation
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T20%3A21%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ruptured%20Tibio-fibular%20Syndesmosis:%20Comparison%20Study%20of%20Metallic%20to%20Bioabsorbable%20Fixation&rft.jtitle=Foot%20&%20ankle%20international&rft.au=Sinisaari,%20Ilkka%20P.&rft.date=2002-08-01&rft.volume=23&rft.issue=8&rft.spage=744&rft.epage=748&rft.pages=744-748&rft.issn=1071-1007&rft.eissn=1944-7876&rft_id=info:doi/10.1177/107110070202300811&rft_dat=%3Cproquest_cross%3E72036217%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=72036217&rft_id=info:pmid/12199389&rft_sage_id=10.1177_107110070202300811&rfr_iscdi=true