New method to assess the registration of CT-MR images of the head

Due to their complementary information content, both x-ray computed tomography (CT) and magnetic resonance (MR) imaging are employed in certain clinical cases to improve the understanding of pathology involved. o spatially relate the two datasets, image registration and image fusion are employed. Ho...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Injury 2004-06, Vol.35, p.S-A105
Hauptverfasser: PAPPAS, Ion P, PUJA, Malik, STYNER, Martin, JUBEI LIU, CAVERSACCIO, Marco
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page A105
container_issue
container_start_page S
container_title Injury
container_volume 35
creator PAPPAS, Ion P
PUJA, Malik
STYNER, Martin
JUBEI LIU
CAVERSACCIO, Marco
description Due to their complementary information content, both x-ray computed tomography (CT) and magnetic resonance (MR) imaging are employed in certain clinical cases to improve the understanding of pathology involved. o spatially relate the two datasets, image registration and image fusion are employed. However, registration errors, either global or local, are common and are nonuniform within the image volume. In this paper, we propose a new algorithm that assesses the quality of the registration locally within the CT-MR volume and provides visual, color-coded feedback to the user about the location and extent of good and bad correspondence between the two images. The proposed registration assessment algorithm is based on a correspondence analysis of bone structures in the CT and MR images. For that purpose, a custom segmentation algorithm for bone in MR images has been developed that is based on a stochastic threshold computation method. This segmentation method for MR images and the CT-MR registration assessment algorithm were validated on simulated MR datasets and real CT-MR image pairs of the head. Some partial-volume effects occur at the borders of the bone structures and at the bone interfaces with air, which cannot be separated from bone in the MR image. The presented assessment method of CT-MR image registration offers the user a new tool to evaluate the overall and local quality of the registration. With this information, the user does not have to blindly trust the fused CT-MR datasets but can easily identify areas of inaccurate correspondence. The application of the algorithm is so far limited to T1-weighted MR and CT images of the head area.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_71996622</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>71996622</sourcerecordid><originalsourceid>FETCH-LOGICAL-p841-a7609bd4a028bfea0e06e584896806e16123708754c05eaa4672303e262e17d53</originalsourceid><addsrcrecordid>eNpNz8FKw0AQBuBFFFurryB70VtgdjfZnRxLUStUBek9TJNJG0mamkkQ394UK3ia-eFj-OdMTQ2GNALrw7maAliIjEM3UVciHwAmgHOXamISgy4YM1XzV_7SDfe7ttB9q0mERXS_Y93xtpK-o75q97ot9WIdvbzrqqEtyzEfzY6puFYXJdXCN6c5U-vHh_ViGa3enp4X81V0wNhEFDykmyImsLgpmYDBc4Ixph7HzXhjXQAMSZxDwkSxD9aBY-stm1Akbqbuf88euvZzYOmzppKc65r23A6SBZOm3ls7wtsTHDYNF9mhGzt339nfzyO4OwGSnOqyo31eyT-HPiCi-wHQjF2k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71996622</pqid></control><display><type>article</type><title>New method to assess the registration of CT-MR images of the head</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>PAPPAS, Ion P ; PUJA, Malik ; STYNER, Martin ; JUBEI LIU ; CAVERSACCIO, Marco</creator><creatorcontrib>PAPPAS, Ion P ; PUJA, Malik ; STYNER, Martin ; JUBEI LIU ; CAVERSACCIO, Marco</creatorcontrib><description>Due to their complementary information content, both x-ray computed tomography (CT) and magnetic resonance (MR) imaging are employed in certain clinical cases to improve the understanding of pathology involved. o spatially relate the two datasets, image registration and image fusion are employed. However, registration errors, either global or local, are common and are nonuniform within the image volume. In this paper, we propose a new algorithm that assesses the quality of the registration locally within the CT-MR volume and provides visual, color-coded feedback to the user about the location and extent of good and bad correspondence between the two images. The proposed registration assessment algorithm is based on a correspondence analysis of bone structures in the CT and MR images. For that purpose, a custom segmentation algorithm for bone in MR images has been developed that is based on a stochastic threshold computation method. This segmentation method for MR images and the CT-MR registration assessment algorithm were validated on simulated MR datasets and real CT-MR image pairs of the head. Some partial-volume effects occur at the borders of the bone structures and at the bone interfaces with air, which cannot be separated from bone in the MR image. The presented assessment method of CT-MR image registration offers the user a new tool to evaluate the overall and local quality of the registration. With this information, the user does not have to blindly trust the fused CT-MR datasets but can easily identify areas of inaccurate correspondence. The application of the algorithm is so far limited to T1-weighted MR and CT images of the head area.</description><identifier>ISSN: 0020-1383</identifier><identifier>EISSN: 1879-0267</identifier><identifier>PMID: 15183711</identifier><identifier>CODEN: INJUBF</identifier><language>eng</language><publisher>Oxford: Elsevier</publisher><subject>Algorithms ; Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Biological and medical sciences ; Brain Diseases - diagnosis ; Brain Diseases - diagnostic imaging ; Diseases of the osteoarticular system ; Humans ; Image Processing, Computer-Assisted - methods ; Magnetic Resonance Imaging - methods ; Medical sciences ; Skull - diagnostic imaging ; Skull - pathology ; Tomography, X-Ray Computed - methods ; Traumas. Diseases due to physical agents</subject><ispartof>Injury, 2004-06, Vol.35, p.S-A105</ispartof><rights>2004 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=15867888$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15183711$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>PAPPAS, Ion P</creatorcontrib><creatorcontrib>PUJA, Malik</creatorcontrib><creatorcontrib>STYNER, Martin</creatorcontrib><creatorcontrib>JUBEI LIU</creatorcontrib><creatorcontrib>CAVERSACCIO, Marco</creatorcontrib><title>New method to assess the registration of CT-MR images of the head</title><title>Injury</title><addtitle>Injury</addtitle><description>Due to their complementary information content, both x-ray computed tomography (CT) and magnetic resonance (MR) imaging are employed in certain clinical cases to improve the understanding of pathology involved. o spatially relate the two datasets, image registration and image fusion are employed. However, registration errors, either global or local, are common and are nonuniform within the image volume. In this paper, we propose a new algorithm that assesses the quality of the registration locally within the CT-MR volume and provides visual, color-coded feedback to the user about the location and extent of good and bad correspondence between the two images. The proposed registration assessment algorithm is based on a correspondence analysis of bone structures in the CT and MR images. For that purpose, a custom segmentation algorithm for bone in MR images has been developed that is based on a stochastic threshold computation method. This segmentation method for MR images and the CT-MR registration assessment algorithm were validated on simulated MR datasets and real CT-MR image pairs of the head. Some partial-volume effects occur at the borders of the bone structures and at the bone interfaces with air, which cannot be separated from bone in the MR image. The presented assessment method of CT-MR image registration offers the user a new tool to evaluate the overall and local quality of the registration. With this information, the user does not have to blindly trust the fused CT-MR datasets but can easily identify areas of inaccurate correspondence. The application of the algorithm is so far limited to T1-weighted MR and CT images of the head area.</description><subject>Algorithms</subject><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Biological and medical sciences</subject><subject>Brain Diseases - diagnosis</subject><subject>Brain Diseases - diagnostic imaging</subject><subject>Diseases of the osteoarticular system</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted - methods</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Medical sciences</subject><subject>Skull - diagnostic imaging</subject><subject>Skull - pathology</subject><subject>Tomography, X-Ray Computed - methods</subject><subject>Traumas. Diseases due to physical agents</subject><issn>0020-1383</issn><issn>1879-0267</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNz8FKw0AQBuBFFFurryB70VtgdjfZnRxLUStUBek9TJNJG0mamkkQ394UK3ia-eFj-OdMTQ2GNALrw7maAliIjEM3UVciHwAmgHOXamISgy4YM1XzV_7SDfe7ttB9q0mERXS_Y93xtpK-o75q97ot9WIdvbzrqqEtyzEfzY6puFYXJdXCN6c5U-vHh_ViGa3enp4X81V0wNhEFDykmyImsLgpmYDBc4Ixph7HzXhjXQAMSZxDwkSxD9aBY-stm1Akbqbuf88euvZzYOmzppKc65r23A6SBZOm3ls7wtsTHDYNF9mhGzt339nfzyO4OwGSnOqyo31eyT-HPiCi-wHQjF2k</recordid><startdate>200406</startdate><enddate>200406</enddate><creator>PAPPAS, Ion P</creator><creator>PUJA, Malik</creator><creator>STYNER, Martin</creator><creator>JUBEI LIU</creator><creator>CAVERSACCIO, Marco</creator><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>200406</creationdate><title>New method to assess the registration of CT-MR images of the head</title><author>PAPPAS, Ion P ; PUJA, Malik ; STYNER, Martin ; JUBEI LIU ; CAVERSACCIO, Marco</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p841-a7609bd4a028bfea0e06e584896806e16123708754c05eaa4672303e262e17d53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Algorithms</topic><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Biological and medical sciences</topic><topic>Brain Diseases - diagnosis</topic><topic>Brain Diseases - diagnostic imaging</topic><topic>Diseases of the osteoarticular system</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted - methods</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Medical sciences</topic><topic>Skull - diagnostic imaging</topic><topic>Skull - pathology</topic><topic>Tomography, X-Ray Computed - methods</topic><topic>Traumas. Diseases due to physical agents</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>PAPPAS, Ion P</creatorcontrib><creatorcontrib>PUJA, Malik</creatorcontrib><creatorcontrib>STYNER, Martin</creatorcontrib><creatorcontrib>JUBEI LIU</creatorcontrib><creatorcontrib>CAVERSACCIO, Marco</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Injury</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>PAPPAS, Ion P</au><au>PUJA, Malik</au><au>STYNER, Martin</au><au>JUBEI LIU</au><au>CAVERSACCIO, Marco</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>New method to assess the registration of CT-MR images of the head</atitle><jtitle>Injury</jtitle><addtitle>Injury</addtitle><date>2004-06</date><risdate>2004</risdate><volume>35</volume><spage>S</spage><epage>A105</epage><pages>S-A105</pages><issn>0020-1383</issn><eissn>1879-0267</eissn><coden>INJUBF</coden><abstract>Due to their complementary information content, both x-ray computed tomography (CT) and magnetic resonance (MR) imaging are employed in certain clinical cases to improve the understanding of pathology involved. o spatially relate the two datasets, image registration and image fusion are employed. However, registration errors, either global or local, are common and are nonuniform within the image volume. In this paper, we propose a new algorithm that assesses the quality of the registration locally within the CT-MR volume and provides visual, color-coded feedback to the user about the location and extent of good and bad correspondence between the two images. The proposed registration assessment algorithm is based on a correspondence analysis of bone structures in the CT and MR images. For that purpose, a custom segmentation algorithm for bone in MR images has been developed that is based on a stochastic threshold computation method. This segmentation method for MR images and the CT-MR registration assessment algorithm were validated on simulated MR datasets and real CT-MR image pairs of the head. Some partial-volume effects occur at the borders of the bone structures and at the bone interfaces with air, which cannot be separated from bone in the MR image. The presented assessment method of CT-MR image registration offers the user a new tool to evaluate the overall and local quality of the registration. With this information, the user does not have to blindly trust the fused CT-MR datasets but can easily identify areas of inaccurate correspondence. The application of the algorithm is so far limited to T1-weighted MR and CT images of the head area.</abstract><cop>Oxford</cop><pub>Elsevier</pub><pmid>15183711</pmid></addata></record>
fulltext fulltext
identifier ISSN: 0020-1383
ispartof Injury, 2004-06, Vol.35, p.S-A105
issn 0020-1383
1879-0267
language eng
recordid cdi_proquest_miscellaneous_71996622
source MEDLINE; Elsevier ScienceDirect Journals
subjects Algorithms
Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy
Biological and medical sciences
Brain Diseases - diagnosis
Brain Diseases - diagnostic imaging
Diseases of the osteoarticular system
Humans
Image Processing, Computer-Assisted - methods
Magnetic Resonance Imaging - methods
Medical sciences
Skull - diagnostic imaging
Skull - pathology
Tomography, X-Ray Computed - methods
Traumas. Diseases due to physical agents
title New method to assess the registration of CT-MR images of the head
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T06%3A49%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=New%20method%20to%20assess%20the%20registration%20of%20CT-MR%20images%20of%20the%20head&rft.jtitle=Injury&rft.au=PAPPAS,%20Ion%20P&rft.date=2004-06&rft.volume=35&rft.spage=S&rft.epage=A105&rft.pages=S-A105&rft.issn=0020-1383&rft.eissn=1879-0267&rft.coden=INJUBF&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E71996622%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71996622&rft_id=info:pmid/15183711&rfr_iscdi=true