The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging

Background: Variable-stiffness colonoscopes combine the flexibility of pediatric instruments for negotiation of the sigmoid colon with the ability to stiffen the insertion tube to prevent or control looping after straightening. Previous studies have found wide variation in the efficacy of the stiffe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 2002-08, Vol.56 (2), p.195-201
Hauptverfasser: Shah, Syed G., Brooker, Jim C., Williams, Christopher B., Thapar, Catherine, Suzuki, Noriko, Saunders, Brian P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 201
container_issue 2
container_start_page 195
container_title Gastrointestinal endoscopy
container_volume 56
creator Shah, Syed G.
Brooker, Jim C.
Williams, Christopher B.
Thapar, Catherine
Suzuki, Noriko
Saunders, Brian P.
description Background: Variable-stiffness colonoscopes combine the flexibility of pediatric instruments for negotiation of the sigmoid colon with the ability to stiffen the insertion tube to prevent or control looping after straightening. Previous studies have found wide variation in the efficacy of the stiffening mechanism. Thus, two studies were conducted to assess the potential benefit of the stiffening device and its optimal use. Methods: In study 1, the effect of routinely stiffening the straightened variable-stiffness colonoscopes in the mid-descending colon was determined in 82 patients. Two insertions were performed (mid-descending colon to cecum) in each patient with and without application of the stiffening device (randomized). The time to negotiate the proximal colon (mid-descending to cecum), time to pass the variable-stiffness colonoscopes across the splenic flexure into the transverse colon, time to pass the right colon, and ancillary maneuvers used were recorded for each insertion. In study 2, consecutive patients, excluding any with previous colonic resection, were examined by using standard adult variable-stiffness colonoscopes. Real-time views of the procedure with magnetic endoscope imaging were recorded for all examinations, but procedures were randomized to be done either with (n = 88), or without (n = 87) the endoscopist viewing the magnetic endoscope imaging display. Whenever stiffening was applied, the anatomic location of the colonoscope tip and stiffness efficacy were recorded. Results: In study 1, time taken to negotiate the proximal colon ( p = 0.0041) and time to negotiate the splenic flexure ( p = 0.006) were significantly shorter and ancillary maneuvers performed were fewer ( p = 0.0014) with the stiffening device activated. In study 2, stiffening was used with similar frequency in patients examined with and without the magnetic endoscope imaging view, most commonly for passing the splenic flexure (71%), but also in the transverse colon (12%), right colon (9%), and sigmoid/descending colon (8%). Stiffening was significantly more effective when used in combination with magnetic endoscope imaging (69% with imager vs. 45% without imager; p = 0.0102). Conclusions: Overall, the variable-stiffness device used was effective in controlling looping 57% of the time. Activating maximum stiffness appears to be effective once the sigmoid colon has been negotiated and the colonoscope straightened with the tip in the proximal colon, reducing the numbe
doi_str_mv 10.1016/S0016-5107(02)70177-6
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71948037</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0016510702701776</els_id><sourcerecordid>71948037</sourcerecordid><originalsourceid>FETCH-LOGICAL-c306t-96e5f8732e91e914bd4bc2bd93221c2e8a9a9e80e1d4d735f38964ae37df33213</originalsourceid><addsrcrecordid>eNqFkF1LHDEUhkNpqavtT7DkpqIXY_MxM5n0poioLQhe1ELvQiY50chssubMCvvvje5SLwshCYfnnPPyEHLI2SlnvP_2m9W76ThTx0ycKMaVavp3ZMGZrh-l9Huy-IfskX3EB8bYICT_SPa44G3X6X5B_t7eA32yJdpxAopzDCEBInV5yimjyyv4Ts8Qa20JaaY5UAghOus2dNzQpb1LMEdHIfktTWOtxXT3iXwIdkL4vHsPyJ_Li9vzn831zdWv87PrxknWz43uoQuDkgI0r6cdfTs6MXotheBOwGC11TAw4L71SnZBDrpvLUjlg5SCywNytJ27KvlxDTibZUQH02QT5DUaxXU7MKkq2G1BVzJigWBWpWYtG8OZeVFqXpWaF1-GCfOq1PS178tuwXpcgn_r2jmswNcdYNHZKRSbXMQ3Tg6yV1pX7seWg6rjKUIx6CIkBz4WcLPxOf4nyjMGFJNJ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71948037</pqid></control><display><type>article</type><title>The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Shah, Syed G. ; Brooker, Jim C. ; Williams, Christopher B. ; Thapar, Catherine ; Suzuki, Noriko ; Saunders, Brian P.</creator><creatorcontrib>Shah, Syed G. ; Brooker, Jim C. ; Williams, Christopher B. ; Thapar, Catherine ; Suzuki, Noriko ; Saunders, Brian P.</creatorcontrib><description>Background: Variable-stiffness colonoscopes combine the flexibility of pediatric instruments for negotiation of the sigmoid colon with the ability to stiffen the insertion tube to prevent or control looping after straightening. Previous studies have found wide variation in the efficacy of the stiffening mechanism. Thus, two studies were conducted to assess the potential benefit of the stiffening device and its optimal use. Methods: In study 1, the effect of routinely stiffening the straightened variable-stiffness colonoscopes in the mid-descending colon was determined in 82 patients. Two insertions were performed (mid-descending colon to cecum) in each patient with and without application of the stiffening device (randomized). The time to negotiate the proximal colon (mid-descending to cecum), time to pass the variable-stiffness colonoscopes across the splenic flexure into the transverse colon, time to pass the right colon, and ancillary maneuvers used were recorded for each insertion. In study 2, consecutive patients, excluding any with previous colonic resection, were examined by using standard adult variable-stiffness colonoscopes. Real-time views of the procedure with magnetic endoscope imaging were recorded for all examinations, but procedures were randomized to be done either with (n = 88), or without (n = 87) the endoscopist viewing the magnetic endoscope imaging display. Whenever stiffening was applied, the anatomic location of the colonoscope tip and stiffness efficacy were recorded. Results: In study 1, time taken to negotiate the proximal colon ( p = 0.0041) and time to negotiate the splenic flexure ( p = 0.006) were significantly shorter and ancillary maneuvers performed were fewer ( p = 0.0014) with the stiffening device activated. In study 2, stiffening was used with similar frequency in patients examined with and without the magnetic endoscope imaging view, most commonly for passing the splenic flexure (71%), but also in the transverse colon (12%), right colon (9%), and sigmoid/descending colon (8%). Stiffening was significantly more effective when used in combination with magnetic endoscope imaging (69% with imager vs. 45% without imager; p = 0.0102). Conclusions: Overall, the variable-stiffness device used was effective in controlling looping 57% of the time. Activating maximum stiffness appears to be effective once the sigmoid colon has been negotiated and the colonoscope straightened with the tip in the proximal colon, reducing the number of ancillary maneuvers and shortening the insertion time through the proximal colon. Routine magnetic endoscope imaging further enhances the efficacy of the variable-stiffness colonoscopes by helping to identify the optimal time for stiffening. (Gastrointest Endosc 2002;56:195-201.)</description><identifier>ISSN: 0016-5107</identifier><identifier>EISSN: 1097-6779</identifier><identifier>DOI: 10.1016/S0016-5107(02)70177-6</identifier><identifier>PMID: 12145596</identifier><identifier>CODEN: GAENBQ</identifier><language>eng</language><publisher>New York, NY: Mosby, Inc</publisher><subject>Biological and medical sciences ; Colon - pathology ; Colonic Diseases - diagnosis ; Colonoscopes ; Colonoscopy ; Endoscopy ; Equipment Design ; Female ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Magnetic Resonance Imaging ; Male ; Medical sciences ; Middle Aged ; Miscellaneous. Technology</subject><ispartof>Gastrointestinal endoscopy, 2002-08, Vol.56 (2), p.195-201</ispartof><rights>2002 American Society for Gastrointestinal Endoscopy</rights><rights>2002 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c306t-96e5f8732e91e914bd4bc2bd93221c2e8a9a9e80e1d4d735f38964ae37df33213</citedby><cites>FETCH-LOGICAL-c306t-96e5f8732e91e914bd4bc2bd93221c2e8a9a9e80e1d4d735f38964ae37df33213</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0016510702701776$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=13836799$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12145596$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Shah, Syed G.</creatorcontrib><creatorcontrib>Brooker, Jim C.</creatorcontrib><creatorcontrib>Williams, Christopher B.</creatorcontrib><creatorcontrib>Thapar, Catherine</creatorcontrib><creatorcontrib>Suzuki, Noriko</creatorcontrib><creatorcontrib>Saunders, Brian P.</creatorcontrib><title>The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging</title><title>Gastrointestinal endoscopy</title><addtitle>Gastrointest Endosc</addtitle><description>Background: Variable-stiffness colonoscopes combine the flexibility of pediatric instruments for negotiation of the sigmoid colon with the ability to stiffen the insertion tube to prevent or control looping after straightening. Previous studies have found wide variation in the efficacy of the stiffening mechanism. Thus, two studies were conducted to assess the potential benefit of the stiffening device and its optimal use. Methods: In study 1, the effect of routinely stiffening the straightened variable-stiffness colonoscopes in the mid-descending colon was determined in 82 patients. Two insertions were performed (mid-descending colon to cecum) in each patient with and without application of the stiffening device (randomized). The time to negotiate the proximal colon (mid-descending to cecum), time to pass the variable-stiffness colonoscopes across the splenic flexure into the transverse colon, time to pass the right colon, and ancillary maneuvers used were recorded for each insertion. In study 2, consecutive patients, excluding any with previous colonic resection, were examined by using standard adult variable-stiffness colonoscopes. Real-time views of the procedure with magnetic endoscope imaging were recorded for all examinations, but procedures were randomized to be done either with (n = 88), or without (n = 87) the endoscopist viewing the magnetic endoscope imaging display. Whenever stiffening was applied, the anatomic location of the colonoscope tip and stiffness efficacy were recorded. Results: In study 1, time taken to negotiate the proximal colon ( p = 0.0041) and time to negotiate the splenic flexure ( p = 0.006) were significantly shorter and ancillary maneuvers performed were fewer ( p = 0.0014) with the stiffening device activated. In study 2, stiffening was used with similar frequency in patients examined with and without the magnetic endoscope imaging view, most commonly for passing the splenic flexure (71%), but also in the transverse colon (12%), right colon (9%), and sigmoid/descending colon (8%). Stiffening was significantly more effective when used in combination with magnetic endoscope imaging (69% with imager vs. 45% without imager; p = 0.0102). Conclusions: Overall, the variable-stiffness device used was effective in controlling looping 57% of the time. Activating maximum stiffness appears to be effective once the sigmoid colon has been negotiated and the colonoscope straightened with the tip in the proximal colon, reducing the number of ancillary maneuvers and shortening the insertion time through the proximal colon. Routine magnetic endoscope imaging further enhances the efficacy of the variable-stiffness colonoscopes by helping to identify the optimal time for stiffening. (Gastrointest Endosc 2002;56:195-201.)</description><subject>Biological and medical sciences</subject><subject>Colon - pathology</subject><subject>Colonic Diseases - diagnosis</subject><subject>Colonoscopes</subject><subject>Colonoscopy</subject><subject>Endoscopy</subject><subject>Equipment Design</subject><subject>Female</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Magnetic Resonance Imaging</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Miscellaneous. Technology</subject><issn>0016-5107</issn><issn>1097-6779</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkF1LHDEUhkNpqavtT7DkpqIXY_MxM5n0poioLQhe1ELvQiY50chssubMCvvvje5SLwshCYfnnPPyEHLI2SlnvP_2m9W76ThTx0ycKMaVavp3ZMGZrh-l9Huy-IfskX3EB8bYICT_SPa44G3X6X5B_t7eA32yJdpxAopzDCEBInV5yimjyyv4Ts8Qa20JaaY5UAghOus2dNzQpb1LMEdHIfktTWOtxXT3iXwIdkL4vHsPyJ_Li9vzn831zdWv87PrxknWz43uoQuDkgI0r6cdfTs6MXotheBOwGC11TAw4L71SnZBDrpvLUjlg5SCywNytJ27KvlxDTibZUQH02QT5DUaxXU7MKkq2G1BVzJigWBWpWYtG8OZeVFqXpWaF1-GCfOq1PS178tuwXpcgn_r2jmswNcdYNHZKRSbXMQ3Tg6yV1pX7seWg6rjKUIx6CIkBz4WcLPxOf4nyjMGFJNJ</recordid><startdate>200208</startdate><enddate>200208</enddate><creator>Shah, Syed G.</creator><creator>Brooker, Jim C.</creator><creator>Williams, Christopher B.</creator><creator>Thapar, Catherine</creator><creator>Suzuki, Noriko</creator><creator>Saunders, Brian P.</creator><general>Mosby, Inc</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>200208</creationdate><title>The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging</title><author>Shah, Syed G. ; Brooker, Jim C. ; Williams, Christopher B. ; Thapar, Catherine ; Suzuki, Noriko ; Saunders, Brian P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c306t-96e5f8732e91e914bd4bc2bd93221c2e8a9a9e80e1d4d735f38964ae37df33213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Biological and medical sciences</topic><topic>Colon - pathology</topic><topic>Colonic Diseases - diagnosis</topic><topic>Colonoscopes</topic><topic>Colonoscopy</topic><topic>Endoscopy</topic><topic>Equipment Design</topic><topic>Female</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Magnetic Resonance Imaging</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Miscellaneous. Technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Shah, Syed G.</creatorcontrib><creatorcontrib>Brooker, Jim C.</creatorcontrib><creatorcontrib>Williams, Christopher B.</creatorcontrib><creatorcontrib>Thapar, Catherine</creatorcontrib><creatorcontrib>Suzuki, Noriko</creatorcontrib><creatorcontrib>Saunders, Brian P.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Gastrointestinal endoscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Shah, Syed G.</au><au>Brooker, Jim C.</au><au>Williams, Christopher B.</au><au>Thapar, Catherine</au><au>Suzuki, Noriko</au><au>Saunders, Brian P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging</atitle><jtitle>Gastrointestinal endoscopy</jtitle><addtitle>Gastrointest Endosc</addtitle><date>2002-08</date><risdate>2002</risdate><volume>56</volume><issue>2</issue><spage>195</spage><epage>201</epage><pages>195-201</pages><issn>0016-5107</issn><eissn>1097-6779</eissn><coden>GAENBQ</coden><abstract>Background: Variable-stiffness colonoscopes combine the flexibility of pediatric instruments for negotiation of the sigmoid colon with the ability to stiffen the insertion tube to prevent or control looping after straightening. Previous studies have found wide variation in the efficacy of the stiffening mechanism. Thus, two studies were conducted to assess the potential benefit of the stiffening device and its optimal use. Methods: In study 1, the effect of routinely stiffening the straightened variable-stiffness colonoscopes in the mid-descending colon was determined in 82 patients. Two insertions were performed (mid-descending colon to cecum) in each patient with and without application of the stiffening device (randomized). The time to negotiate the proximal colon (mid-descending to cecum), time to pass the variable-stiffness colonoscopes across the splenic flexure into the transverse colon, time to pass the right colon, and ancillary maneuvers used were recorded for each insertion. In study 2, consecutive patients, excluding any with previous colonic resection, were examined by using standard adult variable-stiffness colonoscopes. Real-time views of the procedure with magnetic endoscope imaging were recorded for all examinations, but procedures were randomized to be done either with (n = 88), or without (n = 87) the endoscopist viewing the magnetic endoscope imaging display. Whenever stiffening was applied, the anatomic location of the colonoscope tip and stiffness efficacy were recorded. Results: In study 1, time taken to negotiate the proximal colon ( p = 0.0041) and time to negotiate the splenic flexure ( p = 0.006) were significantly shorter and ancillary maneuvers performed were fewer ( p = 0.0014) with the stiffening device activated. In study 2, stiffening was used with similar frequency in patients examined with and without the magnetic endoscope imaging view, most commonly for passing the splenic flexure (71%), but also in the transverse colon (12%), right colon (9%), and sigmoid/descending colon (8%). Stiffening was significantly more effective when used in combination with magnetic endoscope imaging (69% with imager vs. 45% without imager; p = 0.0102). Conclusions: Overall, the variable-stiffness device used was effective in controlling looping 57% of the time. Activating maximum stiffness appears to be effective once the sigmoid colon has been negotiated and the colonoscope straightened with the tip in the proximal colon, reducing the number of ancillary maneuvers and shortening the insertion time through the proximal colon. Routine magnetic endoscope imaging further enhances the efficacy of the variable-stiffness colonoscopes by helping to identify the optimal time for stiffening. (Gastrointest Endosc 2002;56:195-201.)</abstract><cop>New York, NY</cop><pub>Mosby, Inc</pub><pmid>12145596</pmid><doi>10.1016/S0016-5107(02)70177-6</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0016-5107
ispartof Gastrointestinal endoscopy, 2002-08, Vol.56 (2), p.195-201
issn 0016-5107
1097-6779
language eng
recordid cdi_proquest_miscellaneous_71948037
source MEDLINE; Elsevier ScienceDirect Journals
subjects Biological and medical sciences
Colon - pathology
Colonic Diseases - diagnosis
Colonoscopes
Colonoscopy
Endoscopy
Equipment Design
Female
Humans
Investigative techniques, diagnostic techniques (general aspects)
Magnetic Resonance Imaging
Male
Medical sciences
Middle Aged
Miscellaneous. Technology
title The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T18%3A53%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20variable%20stiffness%20colonoscope:%20Assessment%20of%20efficacy%20by%20magnetic%20endoscope%20imaging&rft.jtitle=Gastrointestinal%20endoscopy&rft.au=Shah,%20Syed%20G.&rft.date=2002-08&rft.volume=56&rft.issue=2&rft.spage=195&rft.epage=201&rft.pages=195-201&rft.issn=0016-5107&rft.eissn=1097-6779&rft.coden=GAENBQ&rft_id=info:doi/10.1016/S0016-5107(02)70177-6&rft_dat=%3Cproquest_cross%3E71948037%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71948037&rft_id=info:pmid/12145596&rft_els_id=S0016510702701776&rfr_iscdi=true