Direct-injection high performance liquid chromatography ion trap mass spectrometry for the quantitative determination of olanzapine, clozapine and N-desmethylclozapine in human plasma

A specific and sensitive direct‐injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N‐desmethylclozapine in human plasma....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Rapid communications in mass spectrometry 2002-01, Vol.16 (13), p.1266-1272
Hauptverfasser: Kollroser, Manfred, Schober, Caroline
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1272
container_issue 13
container_start_page 1266
container_title Rapid communications in mass spectrometry
container_volume 16
creator Kollroser, Manfred
Schober, Caroline
description A specific and sensitive direct‐injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N‐desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 × 50 mm i.d., 30 µm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 µm Symmetry C18 (Waters) analytical column (3.0 × 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter‐ and intra‐assay coefficients of variation for all compounds were
doi_str_mv 10.1002/rcm.718
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_71890459</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>71890459</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4178-2de2e624e47404719e6789289fbd32c3fb5b53187b7e11c7217a71f79ede2353</originalsourceid><addsrcrecordid>eNp1kUFv1DAQhS0EoktB_APkExwgxeMk6-SIdqEgyiJVKzhajjNpXJI4aztA-GP8PbxkRU-cZqT53vOTHyFPgV0AY_y10_2FgOIeWQErRcJ4CvfJipU5JBmUxRl55P0tYwA5Zw_JGXAAzvN0RX5vjUMdEjPcxmHsQFtz09IRXWNdrwaNtDOHydRUt872Ktgbp8Z2pkc0xJX2ynvqx6iOdwxuplFJQ4v0MKkhmKCC-Y60xoCuN4P6-4htqO3U8EuNZsBXVHd2WakaarpLavTRqp27u4OJyaYYiI6d8r16TB40qvP45DTPyf7d2_3mfXL1-fLD5s1VojMQRcJr5LjmGWYiY5mAEteiKHlRNlWdcp02VV7lKRSiEgigBQehBDSixChM8_ScPF9sR2cPE_oge-M1djE72snL-Ocly_Iygi8WUDvrvcNGjs70ys0SmDxWJGNFRzySz06WU9VjfcedOonAywX4YTqc_-cjrzefFrtkoY0P-PMfrdw3uRapyOXX3aX88nGXs-vtXm7TP-8Frok</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>71890459</pqid></control><display><type>article</type><title>Direct-injection high performance liquid chromatography ion trap mass spectrometry for the quantitative determination of olanzapine, clozapine and N-desmethylclozapine in human plasma</title><source>MEDLINE</source><source>Access via Wiley Online Library</source><creator>Kollroser, Manfred ; Schober, Caroline</creator><creatorcontrib>Kollroser, Manfred ; Schober, Caroline</creatorcontrib><description>A specific and sensitive direct‐injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N‐desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 × 50 mm i.d., 30 µm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 µm Symmetry C18 (Waters) analytical column (3.0 × 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter‐ and intra‐assay coefficients of variation for all compounds were &lt;11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time. Copyright © 2002 John Wiley &amp; Sons, Ltd.</description><identifier>ISSN: 0951-4198</identifier><identifier>EISSN: 1097-0231</identifier><identifier>DOI: 10.1002/rcm.718</identifier><identifier>PMID: 12112253</identifier><language>eng</language><publisher>Chichester, UK: John Wiley &amp; Sons, Ltd</publisher><subject>Antipsychotic Agents - blood ; Benzodiazepines ; Chromatography, High Pressure Liquid - methods ; Clozapine - analogs &amp; derivatives ; Clozapine - blood ; Humans ; Pirenzepine - analogs &amp; derivatives ; Pirenzepine - blood ; Reproducibility of Results ; Sensitivity and Specificity ; Spectrometry, Mass, Electrospray Ionization - methods</subject><ispartof>Rapid communications in mass spectrometry, 2002-01, Vol.16 (13), p.1266-1272</ispartof><rights>Copyright © 2002 John Wiley &amp; Sons, Ltd.</rights><rights>Copyright 2002 John Wiley &amp; Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4178-2de2e624e47404719e6789289fbd32c3fb5b53187b7e11c7217a71f79ede2353</citedby><cites>FETCH-LOGICAL-c4178-2de2e624e47404719e6789289fbd32c3fb5b53187b7e11c7217a71f79ede2353</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Frcm.718$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Frcm.718$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>315,781,785,1418,27926,27927,45576,45577</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12112253$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kollroser, Manfred</creatorcontrib><creatorcontrib>Schober, Caroline</creatorcontrib><title>Direct-injection high performance liquid chromatography ion trap mass spectrometry for the quantitative determination of olanzapine, clozapine and N-desmethylclozapine in human plasma</title><title>Rapid communications in mass spectrometry</title><addtitle>Rapid Commun. Mass Spectrom</addtitle><description>A specific and sensitive direct‐injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N‐desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 × 50 mm i.d., 30 µm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 µm Symmetry C18 (Waters) analytical column (3.0 × 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter‐ and intra‐assay coefficients of variation for all compounds were &lt;11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time. Copyright © 2002 John Wiley &amp; Sons, Ltd.</description><subject>Antipsychotic Agents - blood</subject><subject>Benzodiazepines</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Clozapine - analogs &amp; derivatives</subject><subject>Clozapine - blood</subject><subject>Humans</subject><subject>Pirenzepine - analogs &amp; derivatives</subject><subject>Pirenzepine - blood</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Spectrometry, Mass, Electrospray Ionization - methods</subject><issn>0951-4198</issn><issn>1097-0231</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kUFv1DAQhS0EoktB_APkExwgxeMk6-SIdqEgyiJVKzhajjNpXJI4aztA-GP8PbxkRU-cZqT53vOTHyFPgV0AY_y10_2FgOIeWQErRcJ4CvfJipU5JBmUxRl55P0tYwA5Zw_JGXAAzvN0RX5vjUMdEjPcxmHsQFtz09IRXWNdrwaNtDOHydRUt872Ktgbp8Z2pkc0xJX2ynvqx6iOdwxuplFJQ4v0MKkhmKCC-Y60xoCuN4P6-4htqO3U8EuNZsBXVHd2WakaarpLavTRqp27u4OJyaYYiI6d8r16TB40qvP45DTPyf7d2_3mfXL1-fLD5s1VojMQRcJr5LjmGWYiY5mAEteiKHlRNlWdcp02VV7lKRSiEgigBQehBDSixChM8_ScPF9sR2cPE_oge-M1djE72snL-Ocly_Iygi8WUDvrvcNGjs70ys0SmDxWJGNFRzySz06WU9VjfcedOonAywX4YTqc_-cjrzefFrtkoY0P-PMfrdw3uRapyOXX3aX88nGXs-vtXm7TP-8Frok</recordid><startdate>20020101</startdate><enddate>20020101</enddate><creator>Kollroser, Manfred</creator><creator>Schober, Caroline</creator><general>John Wiley &amp; Sons, Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20020101</creationdate><title>Direct-injection high performance liquid chromatography ion trap mass spectrometry for the quantitative determination of olanzapine, clozapine and N-desmethylclozapine in human plasma</title><author>Kollroser, Manfred ; Schober, Caroline</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4178-2de2e624e47404719e6789289fbd32c3fb5b53187b7e11c7217a71f79ede2353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Antipsychotic Agents - blood</topic><topic>Benzodiazepines</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Clozapine - analogs &amp; derivatives</topic><topic>Clozapine - blood</topic><topic>Humans</topic><topic>Pirenzepine - analogs &amp; derivatives</topic><topic>Pirenzepine - blood</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Spectrometry, Mass, Electrospray Ionization - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kollroser, Manfred</creatorcontrib><creatorcontrib>Schober, Caroline</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Rapid communications in mass spectrometry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kollroser, Manfred</au><au>Schober, Caroline</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Direct-injection high performance liquid chromatography ion trap mass spectrometry for the quantitative determination of olanzapine, clozapine and N-desmethylclozapine in human plasma</atitle><jtitle>Rapid communications in mass spectrometry</jtitle><addtitle>Rapid Commun. Mass Spectrom</addtitle><date>2002-01-01</date><risdate>2002</risdate><volume>16</volume><issue>13</issue><spage>1266</spage><epage>1272</epage><pages>1266-1272</pages><issn>0951-4198</issn><eissn>1097-0231</eissn><abstract>A specific and sensitive direct‐injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N‐desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 × 50 mm i.d., 30 µm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 µm Symmetry C18 (Waters) analytical column (3.0 × 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter‐ and intra‐assay coefficients of variation for all compounds were &lt;11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time. Copyright © 2002 John Wiley &amp; Sons, Ltd.</abstract><cop>Chichester, UK</cop><pub>John Wiley &amp; Sons, Ltd</pub><pmid>12112253</pmid><doi>10.1002/rcm.718</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0951-4198
ispartof Rapid communications in mass spectrometry, 2002-01, Vol.16 (13), p.1266-1272
issn 0951-4198
1097-0231
language eng
recordid cdi_proquest_miscellaneous_71890459
source MEDLINE; Access via Wiley Online Library
subjects Antipsychotic Agents - blood
Benzodiazepines
Chromatography, High Pressure Liquid - methods
Clozapine - analogs & derivatives
Clozapine - blood
Humans
Pirenzepine - analogs & derivatives
Pirenzepine - blood
Reproducibility of Results
Sensitivity and Specificity
Spectrometry, Mass, Electrospray Ionization - methods
title Direct-injection high performance liquid chromatography ion trap mass spectrometry for the quantitative determination of olanzapine, clozapine and N-desmethylclozapine in human plasma
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T01%3A48%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Direct-injection%20high%20performance%20liquid%20chromatography%20ion%20trap%20mass%20spectrometry%20for%20the%20quantitative%20determination%20of%20olanzapine,%20clozapine%20and%20N-desmethylclozapine%20in%20human%20plasma&rft.jtitle=Rapid%20communications%20in%20mass%20spectrometry&rft.au=Kollroser,%20Manfred&rft.date=2002-01-01&rft.volume=16&rft.issue=13&rft.spage=1266&rft.epage=1272&rft.pages=1266-1272&rft.issn=0951-4198&rft.eissn=1097-0231&rft_id=info:doi/10.1002/rcm.718&rft_dat=%3Cproquest_cross%3E71890459%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=71890459&rft_id=info:pmid/12112253&rfr_iscdi=true